Loading...
05-100398 E I 411 S ty DFederal Way Electrical Permit #: 05 - 100398 - 00 - EL Community Development Services P.O.Box 9718 Federal Way,WA 98063-9718 Ph:(253)835-7000 Fax (253)835-2609 Inspection request line: (253) 835-305U Project Name: ORCHID LANE LOT 9 Project Address: 34217 13TH 5W IPI SW Parcel Number: 640370 0090 Project Description: Install 200-amp service and wiring for new single family residence. Owner Applicant Contractor HARBOUR HOMES,INC. PROVIDENT ELECTRIC,INC. PROVIDENT ELECTRIC,INC. 1300 DEXTER AVE N PO BOX 59284 PO BOX 59284 SEATTLE WA RENTON WA 98058 RENTON WA 98058 (425)271-4648 Electrical Fixtures Description Quantity Description !Quantity Description --Quantity1 Service: -Residential 3239 PERMIT EXPIRES July 30,2005. Permit issued on January 31,2005 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use be in accordance with the laws,rules and regulations of the State of Washington and the City of Federal Way. , N Owner or agent: , !' ,illf_I'L`, Date: 0\ \ 5 \2)05 THIS CARD IS TO REMAIN ON-SITE * .f b. CITY OF Community Development Inspection Recoici Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT#: 05-100398-00-EL Owner: HARBOUR HOMES, INC. Address: 34217 13TH PL SW FEDERAL WAY, WA 98023 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Slab/Concrete Floor(4255) 0 Ditch cover(4030) 0 Pool Bonding(4195) Approved to place concrete Approved Approved By Date By Date By Date ❑ Temporary Power(4275) .P Service(4235) ❑ Feeders/Sub-panels(4045) Approved Approved Approved By Date By Nies, Date By Date KA Rough Electrical (4225) , .❑ Ceiling Cover(4020) 1.11 Final-Electrical(4055) Approved Approved Approved By4t) Date .Under-slab groundwork(4295) Approved By Date I RECEIVED 12. ' / o 3. .2 ; ' "eratWay PERMIT catturper oristormors& sss JAN 3 1 2005 SF MF Co ME 110-L DE EN FP :',S'PEOLV WAY=TN9•80 -9718sax 7I8 F LI C AT I a N / / F3DG4•L�:!WA 9d06JA7'!d 211-6BL-111P•TAx2•53 1-+12gCITY OF FEDE A A `ww.eationicd °"'°"" BUILDING DEPT. The o•• • • is • -- in orination-an incomplete application win not be accepted. Please print . ,. . fin inkl or _J.. PRitrr rc><Y DIFORWA ION SITE ADDRESS "34a•1 .7 13 ' PL 5 vi SvrrE/UPiIT • ASSESSOR'S TAX/PARCEL * __@10 _3_ 2_ 0 - 00 _2_ ___O LOT SI=(sl) LEGAL DESCRIPTION (e.g.Acme Estes, Lot 1) Dy .C14 I 1)Y LftAJ E1 LDY c PROJECT IIYFORM.TION - TYPE OF PERMIT C BUILDING C PLUMBING a MECHANICAL C DEMOLITION XELECTR1CAL a ENGfl EERING a FIRE PREVENTION SYSTEM PROJECT DESCRIPTION(Provide detailed description of work included on.this oermit only) ,WO MMP SER.Urc.E wtleI n1Cs' PROJECT NAME(Name of Business or Ower Last Name) PP-0y i DENT ELeL I P.+ ( L • / Af C, . PEOPLE INFORMATION PROPERTY NAME PRIMARY PHONE OWNER f f'4g B0 LA,12, 11OM.ES I 61-. 3) ,240( - .6 3 MAILING ADDRESS CrrY.STATE.ZIP 3 3 o 9 Avz 6 1 t-cd era i wry , v 'A q'o0 3 CONTRACTOR COMPANY NAME APPLICANT NAME OFFICE PHONE ?R.ovtt Ni E1.47,iklL 1.6.r (c153) (o-61 - 1150 MAILING ADDRESS TCELL PHONE PC Eox 6x3,24- IcIe.1.7.E.-znPs Ni, wor agoSi ( ) - CTY OF FEDERAL.WAY BUSINESS LICENSE NUMBER EXPIRATION OATS FAX NUMBER _ / / (62-53) (0 3( - 71 94 CONT:.ACi ORS REGISTRATION NUMBER(eery of cast zimp sz.d wash each apptiws ) EENPLR.ATION DATE 24- QILial1. o3cel- a ( a.a- / 01 APPLICANT COMPANY NAME I APPLICANT NAMEOFFICE PHONE - . 1 CEL+. MAILING ADDRESS I C^,Y.STATS.Z".2. 1 ( PHO) - I RELTT.ONSNS?TO PROJECT .'AX:1UMi3ER ?rchitect C Tenant =Agent C Other(Desc-be) ( ) - CONTACT I ,Au RCtrevI aSa' S!0 3( - ' 1Oi E-MAIL ADDRESS LENDER I, Per NCS?Z9t�7.09.s: Lender irfotrrr�iort z YAM. r•agtdred ifprj �alca asaeds Ss;DCO 1 M ai�D O ADDRESS 1 .7.17i.STATE C I I DETAILED IR ILDhI G 1 FORMATION =STING USE PROPOSED DSC L_. EXIST=ASSESSED/RAISED VALUE S VALUE OF PROPOSED WORE $ . SPRLTICLERED BDII.DLNG? C YES = 30 FIRE SUPPRESSION SYSTEM PROPOSED/RLZZD .QD ? _YES C NO WATT=MICE PROVIDER C:LABMHAVEN a HEGERM.. C TACOMA C PRIVATE(WEELL) b w-at SERVICE PROVIDER = LAE=HAVEN = HIGHLLYE a PRIVATE(SEPTIC) PROJECT FLOOR AREAS AREA DESCRIPTION 1 EX/STING SQ.FT. [ PROPOSED SQ. FT. I TOTAL BASEMENT ( 1)I:I'ARThIEN'F OF LABOR ANI) INI)USTRU S FIRST SECOND LICENSED AS PROVIDED BY LAW AS THIRD ELEC CONTR GENERAL FOURTH .LICENSE if EXP. DATE ADDMONAL FLOORS(DESCI ECO1 .` PROVIEI103C2 02/22/2006 EFFECTIVE DATE 02/22/1990 DECK(COVERED?) PROVIDENT ELECTRIC INC GARAGE/CARPORT PO BOX 59284 HOW MANY FLOORS? RENTON WA 98058 r""=WM°"" "PEW HOMES ONLY" NUMBER OF BEDROOMS t ESTIMATED SELLING PRICE $ _ FIXTURE'S Ind ate number of each type of f zture to be installed or relocated as part of this project. Do not include existing fixtures to remain. M CHAere r. Value of Mechanical Work S AIR HANDLING UNITS EVAPORATIVE COOLERS GAS LOGS REFRIG.SYSTEMS BBQS FANS HOODS teommaeias WOODSTOVES BOILERS FIREPLACE INSERTS RANGES MISC(Describe) COMPRESSORS FURNACES GAS WATER HEATERS DUCTS GAS PIPE OUTLETS PLVPLVIIIIMIGMISE(Describe) BATHTUBS(or Tub/sbowerCombo) SHOWERS WATER CLOSETS(Nilo DISHWASHERS SINKS DRINKING FOUNTAINS GAS PIPE OUTLETS SUMPS RAINWATER SYST WASHING MACHINES URINALS HOSE BIBBS LAMS fsohm=sm ® VACUUM BREAKERS ELECTRIC WATER HEATERS DISCLAIMER/SIGNATURE BLOCK I artily wider penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and f gs ther,that I am astberised by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harrn/ar the City of Federal Way as to any claim(Including costs, expenses, and attorneys'fees incurred in the investigation and defense of such eking, which may be made by any person, including the undsrslgnsd,and filed against the City of Federal Way,but only where such claim arises eel of the reliance of the city, including its officers and employees,upon the accuracy of the information supplied to the city as a part of this application. DATE ( cL8fDS NAME/TITLErnde► (s;gazcuc�e) RELA IONSEIP TO PROJECT C Owner C Agent u Contractor C Architect a Other FOOVF'IC E.rm.oRLY -,:' R - I =NEW _ADDITION c ALTERATION =REPAIR =TENANT IMPROVEMENT BUILDING SMELL ONLY? =YES = NO I BASIC PLAN? =YES -NO ZONING DESIGNATION I CEANGE OF USE? =YES =NO NEW ADDRESS REQUIRED? =YES =NO I UP/SEPA/SU? =YES =NO PLATTED LOT? =YES =NO I DEMO PERMIT REQUIRED? =YES =NO i • Bullet#100-March 30,2004 Page 2 of 4 ialandouts-Revised\PtrtTtit Application ELECTRICAL PERMIT INFORMATION RESIDENTIAL COMMERCIAL NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE a� Single Family Square Feet 3 a 3 ` Service or Feeder Each Add'n (First 1300 ft2-$104.50;Each add'n 500 ft2-$33.50) 0 0 to 100 amp $113.50 $69.50 O Detached outbuilding or garage 0 101-200 amp 141.00 89.00 (Inspected with service) $44.00 0 201-400 amp 264.50 104.00 0 Detached outbuilding or garage 0 401-600 amp 308.00 123.50 (Inspected separately) $69.50 0 601-800 amp 398.50 168.50 NEW MULTI-FAMILY(three units or more) CI 801 - 1000 amp 486.50 203.50 Service Feeder 0 Over 1000 amp 530.50 283.00 ❑ Up to 200 amp $113.50 $33.50 ❑ 201 -400 amp 141.00 69.50 0 Over 600 volts surcharge $89.00 ❑ 401•-600 amp 193.00 96.00 • 0 Mast or meter repair $96.00 O 601 -800 amp 247.00 132.00 ALTERED COMMERCIAL/INDUSTRIAL ❑ Over 800 amp 353.50 264.50 Service or Feeders ALTERED SINGLE/MULTI FAMILY 0 0 to 200 amp $113.50 0 201 -600 amp 264.50 Service or Feeder 0 601 - 1000 amp 398.50 O 0 to 200 amp $87.00 0 over 1000 amp 443.50 O 201 -600 amp 141.00 O over 600 amp 212.50 ❑ #of circuits to be added/altered (1-5 circuits-$89.00;Add'n circuits,$7.00/ea) ❑ #of circuits to be added/altered (1-4 circuits$69.50;Add'n circuits$7.Q0/ea) COMMERCIAL/INDUSTRIAL PLAN REVIEW $89.00 plus 35%of Permit Fee O Mast or meter repair $52.00 0 Service- 1,000 amps or greater ❑ Medical/Educational/Institutional Facility SINGLE/MULTI FAMILY PLAN REVIEW O Service Over 400 amps $74.00 plus 35%of Permit Fee MOBILE HOMES O Service or feeder only $69.50 TEMPORARY SERVICE ❑ Service and feeder $113.50 Residentla iMuitt-Famiiy/Commereial//ndustrlal $61.00 MOBILE HOME/RV PARK ❑ #of service or feeders Commercial/Industrial Service or Feeder Ampacity (First service/feeder-$69.50;each add'n-$45.00) 0 0- 100 amps $69.50 ❑ 101-200 amps 89.00 ❑ 201-400 amps ,104.50 ❑ 401-600 amps 141.00 ❑ over 600 amps 152.50 MISCELLANEOUS SERVICE/EQUIPMENT ❑ #of Thermostats 0 #of Signs (First-$52.00;add'n-$16.00/ea) (First sign-552.00;add'n sign 524.50/ea) 0 Low Voltage 0 Swimming pool/hot tub $87.00 Square Feet to be served by system(s) (Includes additional circuit,if required) ❑ Fire Alarm System 0 Yard Pole meter loops S 104.50 ❑ Security Alarm System ❑ Additional Plan Review 5104.50/hour ❑ Voice Cabling (for modified submittals) ❑ Data Cabling (Per System(s) la 2500 ft-S61.00; Each add'n 2500 ft2-16.00) •Per WAC 296-46-9I0(SMb*&ii) Bulletin#100-December 8.2004 Page 3 of 4 k\Haadouts\Permit Application