Loading...
05-100929 City of Federal Way Electrical Permit #: 05 - 100929 - 00 - EL Community Development Services P.O.Box 9718 Federal Way,WA 98063-9718 Ph:(253)835-7000 Fax (253)835-2609 Inspection request line: (253) 835-305C Project Name: DANVILLE STATION 2/4 Project Address: 1909 SW 346TH P 1 Parcel Number: 189546 0040 Project Description: Installing a new 200 amp service and associated wiring. Owner Applicant Contractor SCHNEIDER HOMES,INC. BYERLY ELECTRIC INC BYERLY ELECTRIC INC 6510 SOUTHCENTER BLVD 28001 173RD PL SE 28001 173RD PL SE TUKWILA WA 98188 KENT WA 98042 KENT WA 98042 (253)639-8773 Electrical Fixtures Description Quantity Description Quantity Description Quantity Service: -Residential 2912 PERMIT EXPIRES August 27,2005. Permit issued on February 28,2005 I hereby certify that the above information is correct and that the construction on the above described propertypand the occupancy and the use will be in accordance with the laws,rules and regulations of the State of W4 skington and the City of Federal Way. Owner or agent: A Date: , I os ,_A THIS CARD IS TO REMAIN ON-SITE - A. CITY OF Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT #: 05-100929-00-EL Owner: SCHNEIDER HOMES, INC. Address: 1909 SW 346TH PL FEDERAL WAY, WA This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. O Slab/Concrete Floor(4255) 0 Ditch cover(4030) 0 Pool Bonding(4195) Approved to place concrete Approved Approved By Date By Date By Date ❑ Temporary Power(4275) Service(4235) 0 Feeders/Sub-panels(4045) Approved Approved Approved By Date Bye__v ,J Date 03-tc-05 By Date al Rough Electrical(4225) ❑ Ceiling Cover(4020) )2 Final-Electrical(4055) Approved Approved Approved B ,J Dated 9-1,t2,,--Q1— By DateBye, kw Date(9 . lift ❑ Under-slab groundwork(4295) Approved By Date RECEIVED • FEB 2 8 2005 ""'°`��� ITY OF FEDERAL D6 _ 1 0oaizq Federal Way PE RM I`I� Y OF FEDING DEPT. AF MF COM CIOPL DE EN FP OMMUNI Y DEVELOPMENT SERVICES I • 530FIRSTWAY SOUTH•PDB19718 FEDERAL.WAY,WA 9806)97718 APPLICATION D / / 153661411.5•FAX 253.661.4129 gity lygfLi L+1SIriaeMm The ollowi ' is •wired i conflation-an inco •lete a°°lication will not be ac •ted. Please • nt le•ibl n in or . PROPERTY INFORMATION SITE ADDRESS 1909 S.W. 346th PI. , Federal Way, WA SUITE/UNIT 1 ASSESSOR'S TAX/PARCEL I — LOT SIZE(sn Station Lot 04 (A""` ,EGAL DESCRIPTION(e.g.Acme Estates,Lot IJ Danville .p I r m.,*knew&d .Tho.) PROJECT INFORMATION TYPE OF PERMIT 0 BUILDING ❑PLUMBING 0 MECHANICAL O DEMOLITION O ELECTRICAL O ENGINEERING❑ FIRE PREVENTION SYSTEM ., PROJECT DESCRIPTION(Provide detailed description of work included on this permit onlu) 200 Amp new construction PROJECT NAME(Name of Business or Owner Last Name) Danville Station Lot 04 PEOPLE INFORMATION , NAME PRIMARY PHONE PROPERTY OWNER Schneider Homes, Inc. ( 206) 24S 2471 MAILING ADDRESS ICITY,STATE,ZIP 6510 Southcenter Blvd.#1 I Tukwila, WA 98188 APPLICANT NAME OFFICE PI IONE CONTRACTOR COMPANY NAME ( 253) 639 - 8773 Byerly Electric, Inc Sheila Burdick CL'25LL 3) MAILING ADDRESS CITY,STATE,ZIP ONE 28001 173rd PI. S.E. Kent, WA 98042 ( ) CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER 12EXPIRATION 31 D TE/ 2005 AX NUMBER - 19 - 99 - 107374 - 00 -B L ( CONTRACTOR'S REGISTRATION NUMBER(copy doled required with each eppleetioe) EXPIRATION DATE BYERLEI000BG 01 / 07 / 2006 APPLICANT COMPANY NAME APPLICANT NAMEOFFICE PHONE . Byerly Electric, Inc. Sheila Burdick ( 253) 639 - 8773 CEI.I.PII(1NE MAILING ADDRESS CITY,STATE,ZIP 28001 173rd PI. S.E. Kent, WA 98042 ( ) - RELATIONSHIP TO PROJECT FAX NUMBER 0 Architect ❑Tenant a Agent ❑Other(Describe) ( ) - NAME PRIMARY PHONE E-MAI),ADDRESS CONTACT Mike Byerly ( 253) 639- 8773 LENDER Per RCW 19.27.095: Lender information is NAME required If project value accords$5,000 MAILING ADDRESS CITY,STATE,ZIP DETAILED BUILDING INFORMATION EXISTING USE PROPOSED USE EXISTING ASSESSED/APPRAISED VALUE $ VALUE OF PROPOSED WORK $ SPRINKLERED BUILDING? 0 YES O NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED? 0 YES 0 NO WATER SERVICE PROVIDER 0 LAKEHAVEN ❑HIGHLINE 0 TACOMA 0 PRIVATE(WELL) SEWER SERVICE PROVIDER 0 LAKEHAVEN 0 HIGHLINE 0 PRIVATE(SEPTIC) ■ pRU.IL(T FLOUR,,,PLA,-, AREA DESCRIPTION EXISTING PROPOSED TOTAL • SQ.FT. SQ.FT. SQ.FT. BASEMENT FIRST SECOND THIRD FOURTH ADDITIONAL FLOORS(DESCRIBE) DECK(COVERED?) GARAGE 0 CARPORT 0 MORNS MORN= TOTAL TOTALeLernlew TOTAL e1eer0STOw TOTAL TO NUMBER OF FLOORS **NEW IIOMI;S ONLY" NUMBER OF BEDROOMS ESTIMATED SELLING PRICE $_ . ._.__ F I\'i i_`121:S Indicate number of each tjie of fixture to be installed or relocated as part of this project Do not include existing fixtures to remain. MECHANICAL Value of Mechanical Work$ __ AIR HANDLING UNITS EVAPORATIVE COOLERS GAS LOGS _ REFRIG.SYSTEMS BBQS FANS HOODS ICO Too W UUIYS I'UV ES BOILERS FIREPLACE INSERTS RANGES _ MISC(Describe) COMPRESSORS FURNACES GAR WATER HEATERS DUCTS GAS PIPE OUTLETS PLUMBING BATHTUBS to.Tob/Sho,00.Combat SHOWERS WATER CLOSETS meet) MISC(Describe) DISHWASHERS SINKS DRINKING FOUNTAINS GAS PIPE OUTLETS SUMPS RAINWATER SYST WASHING MACHINES URINALS HOSE BIBBS LAYS lamb...swim) VACUUM BREAKERS ELECTRIC WATER HEATERS I)1S, LAIAIER.Si(FN.ATT-RF ELOCK I eertUg under penally of perjury that the information furnished by me is true and correct to the best of my knowledge,and farther,that I am authorised bg the owner of the above premiss,to perform the work for which the permit application is mads. I further agree to hold harmless the City of Federal Wag as to any claim(including casts,expense,and attorneys'fees incurred in the investigation and defense of such claim},which may be made by any person,including the undersigned,and flied against the City oFederal Wag,but only where such claim arises oat of the reliance/, the city,including its officers and employees,upon the accuracy of the Im gbration supplied to the city as a part of this apptleatioa. NAME/TITLE 4 i 1A &LAALCLI fj �J DATE J - —D Signature) (Title) RELATIONSHIP TO PROJECT ❑Owner Li Agent 0 Contractor 0 Architect 0 Other FOR OFFICE USE ONLY a NEW a ADDITION a ALTERATION a REPAIR a TENANT IMPROVEMENT BUILDING SHELL ONLY? a YES a NO BASIC PLAN? a YES a NO ZONING DESIGNATION CHANGE OF USE? o YES a NO NEW ADDRESS REQUIRED? r YES a NO IIP/SEPA/SU? n YES a NO PLATTED LOT? o YES a NO DEMO PERMIT REQUIRED? a YES a NO Bulletin#100–August I9,2004 Page 2 of 4 k\Handouts\Permit Application ELECTRICAL PERMIT INFORMATION RESIDENTIAL COMMERCIAL NEW COMMERCIAL/INDUSTRIAL SERVICE NEW RESIDENTIAL SERVICE -` pl Service or Feeder Each Add'n Single Family Square Feet /4 ❑ 0 to 100 amp $113.50 $69.50 (First 1300 1t2-$104.50;Each add'n 500 ft2-$33.50) ❑ Detached outbuilding or garage ❑ 101-200 amp 141.00 89.00 (Inspected with service) $44.00 ❑ 201-400 amp 264.50 104.00 ❑ Detached outbuilding or garage ❑ 401-600 amp 308.00 123.50 (Inspected separately) $69.50 ❑ 601-800 amp 398.50 168.50 ❑ 801 - 1000 amp 486.50 203.50 NEW MULTI-FAMILY(three units or more) ❑ Over 1000 amp 530.50 283.00 Service Feeder ❑ Over 600 volts surcharge $89.00 LI Up to 200 amp $113.50 $33.50 ❑ Mast or meter repair $96.00 ❑ 201 -400 amp 141.00 69.50 ❑ 401 -600 amp 193.00 96.00 ALTERED COMMERCIAL/INDUSTRIAL ❑ 601 -800 amp 247.00 132.00 ❑ Over 800 amp 353.50 264.50 Service or Feeders ❑ Oto 200 amp $113.50 ALTERED SINGLE/MULTI FAMILY U 201 -600 amp 264.50 ❑ 601 - 1000 amp 398.50 • Service or Feeder ❑ over 1000 amp 443.50 ❑ 0 to 200 amp $87.00 ❑ 201 -600 amp 141.00 ❑ #of circuits to be added/altered U over 600 amp 212.50 (1-5 circuits-$89.00;Add'n circuits,$7.00/ea) COMMERCIAL/INDUSTRIAL PLAN REVIEW ❑ _#of circuits to he adderl/altered $89.00 plus 35%of Permit Fee (]-4 circuits-$69.50;Add'n circuits$7.00Jea) ❑ Service- 1,000 amps or greater ❑ Mast or meter repair $52.00 ❑ Medical/Educational/Institutional Facility MOBILE HOMES U Service or feeder only $69.50 ❑ Service and feeder $113.50 TEMPORARY SERVICE MOBILE HOME/RV PARK Residential/Muiti-Family $61.00 ❑ #of service or feeders roiaT/Industriai Service or Feeder Ampacity (First service/feeder-$69.30;each add'n-$45.00) C©mme ID0-100 amps $69.50 Feeder ❑ 101-200 amps 89.00 ❑ 201-400 amps 104.50 ❑ 401-600 amps 141.00 ❑ over 600 amps 152.50 MISCELLANEOUS SERVICE/EQUIPMENT U #of Thermostats U #of Signs (First-$52.00;add'n-$16.00/ea) (First sign-$52.00;add'n sign$24.50/ea) U Low Voltage U Swimming pool/hot tub $87.00 (Includes additional circuit,if required) Square Feet to be served by system(s) $104.50 ❑ Fire Alarm System U Yard Pole meter loops ❑ Security Alarm System ❑ Additional Plan Review $104.50/hour ❑ Voice Cabling (for modified submittals) ❑ Data Cabling U Automation Fee on all Permits .. $5.00 (❑Per System(s)Pt 2500 ft2-$61.00; Each add'n 2500 ft2-16,00)'Per WAC 296-46-9J0(5)1b)fi&ii) Bulletin#100-January 7,2005 Page 3 of 4 k\Handouts\Permit Application