19-103928 - an Building - Multi Family City of Federal way Permit #:19-103928-00-MF Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: PAVILION APARTMENTS,BLDG 17 Project Address: 1900 SW CAMPUS DR Parcel Number: 132103 9103 Project Description: REP-Repair rotted portions of deck and replace posts for Units 17-201, 17-202, 17-203, 17- 204, 17-303 & 17-304. Owner Applicant Contractor Lender PRIME CATALINA CAMPUS TINA TSAIDOLAN COMPANY DOLAN COMPANY INC OWNER IS LENDER DRIVE I LLC INC 220 S BRANDON ST 50 CALIFORNIA ST#2525 220 S BRANDON ST SEATTLE WA 98108 SAN FRANCISCO CA 94111 SEATTLE WA 98108 � J Census Category: 434-Residential alt/add-no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area(sq.ft.) Additional Permit Information Mechanical to be Included? No Number of Stories 2 Is this an Online or O.T.C.applications Yes Permit for Building Shell Only? No Plumbing to be Included? No Total Valuation:8,000.00 IREI � . _ .. . „�R ' / " g" 1 t s 5 ,.x »„ s 3Y0,re�3�, � „�e '.. PERMIT EXPIRES Wednesday, 12 February,2020 Permit Issued on Friday,August 16,2019 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Q Owner or agent: 12 \ ►C,.? Tom,1�'� Date: 2-19 1 9 t1 THIS CARD IS TO REMAIN ON-SITE -%.-,H4lk CITY of Federal Way Construction Inspection Record y INSPECTION REQUESTS: (253)835-3050 PERMIT#: 19 103928 00 Address: 1900 SW CAMPUS DR Bldg 17 Project: PRIME CATALINA CAMPUS DRIVI FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. , ® Initial Erosion Control(4365) ® Footings/Setback(4110) ® Foundation Wall(4115) To be done PRIOR to breaking ground Approved to place concrete Approved to place concrete By Date By Date •By Date • ® Drainage/Downspout(4040) ® Re-steel(4215) , ® Slab/Concrete Floor(4255) Approved to backfill Approved to place concrete or grout Approved to place concrete By Dateo.By Date By Date • • , ® Underfloor Framing(4285) ® Floor Sheathing(4105) � ® Shear Walls(4245) Approved to sheath floor Approved to install flooring Approved to install siding •By Date .,By Date 1•By Date Roof Sheathing(4220) ® Fire/Draft Stops(4095) .4,--, 1111 Interim Erosion Control(4370) Approved to install roofing Approved Approved By Date By Date d•By Date Prior to scheduling a Framing inspection; 13 Framing(4120) i4 Insulation(4150) Electrical,Plumbing&Mechanical Rough-in Approved to insulate Approved to install wallboard and Fire/Draft Stop inspections must be signed- off and approved. IBC 109.3.4 By L Date i By Date 1:1 Gypsum Wallboard Nailing(4130) ! ® Suspended Ceiling Grid(4265) 9 Final-SKF&R(4060) Approved to install mud&tape Approved to drop tile Approved By Date By Date By Date 1:1 Final Erosion Control(4375) El Final-Building(4050) Approved Approved By Date By CWS Date It/ ���' El Rough Electrical 0 Final ElectricalElRight of Way Approved Approved Approved By Date By Date By Date ,...4.„ RECEIVED PERMIT APPLICATION CITY OF AUG3 201% ERMIT CENTER+33325 8th Avenue South + Federal Way,WA 98003-6325 Federal Way 253-835-2607 + FAX 253-835-2609 +permitcenter@cityoffederalway.com CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT}} PERMIT NUMBER 1 -. ( 0 5 L S. - �� ri N' A___ TARGET DATE SITE ADDRESS SUIT / NIT# -7,,C-L ( Cl 00 5/A) Cam.71 ,vfir. 'S,0 Gc ( - •- okil� v,3 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ IN00 2 1 0 ' - 1 0 3 * TYPE OF PERMIT X BUILDING ❑ PLUMBING 0 MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVEN 0te' NAME OF PROJECT � ////���� - 44 T av- 1�0� `R [-Vet 3 , ,,Ppa- 0c,,k o - PROJECT DESCRIPTION ?o� Yt)-t�P ?�Yt- )\/\c 6 -- d�e� oky\s� Yllac-e r•Dc-1, Detailed description of work to ` be included on this permit only E n }� �,q� 'f PRIMARY PHONE kr"PROPERTY OWNER \�t Cr.-l.11 ho, C ` u/� r tvv i MAILING l 0,.V VV1 7 j^ (/5 > E-MAIL CITY STATE ZIP Saw C ��� cNAMo cJ cpyy,pavqIV L- Pr°A 3?cis7 MAILING ADDRESS E-MAIL /' / CONTRACTOR '- -2X' S /CAN\A°V 7(�“- ' 'Vil\li�v�,�",9'Qn CAiy044' Ca STAT$, ZI�epi D FAX - WA STATE CONTRACTOR' LI�F�ISE# �V,`-t, ' EXPIRATION DATE'� FEDERAL WAY BUSINESS LICENSE# NAME (A )26(v\-I ^ Y` l/ PItI Y PH / 4/Jo APPLICANT- MAILING ADDS "'��VVV��, E-,,,, .II. CI7 _ ji( S7). ZIP ^ O Q/ FAX - NE HO PROJECT CONTACT e' T 0 P �p !> �� (The individual to receive and MAILING ADDRESS p E- L �j // respond to all correspondence 2 C �YCONCL ''t ^ ONA(1/ Weiv,I Dmpay,,if) concerning this application) CITY \::,/,....\ STATE ZIP FAX 1 cectcdtL PROJECT FINANCING NAME 0 OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses, and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. /- PRINT SIGNATURE: DATE NAME: /MA r4 ft/l Bulletin#100-January 29,2016 Page 1 of 2 k:\Handouts\Permit Application GENERAL STRUCTURAL NOTES BUILDING CODE 2015 INTERNATIONAL BUILDING CODE DESIGN METHOD ALLOWABLE STRESS DESIGN (ASD) FLOOR LOADS DEAD LOAD: 15 psf LIVE LOAD: 60 psf (DECKS) ROOFLOADS DEAD LOAD: 17 psf LIVE LOAD (SNOW): 25 psf WIND DESIGN DATA 1. BASIC WIND SPEED (ULTIMATE): 110 MPH 2. BASIC WIND SPEED (NOMINAL): 85 MPH 3. WIND EXPOSURE: C 4. Kzt = 1.0 5. ANALYSIS PROCEDURE: ENVELOPE SIMPLIFIED SESIMIC DESIGN DATA 1. SEISMIC IMPORTANCE FACTOR: 1.0 2. RISK CATEGORY: II 3. SPECTRAL RESPONSE ACCEL (Si 1.296 4. SITE CLASS: D (ASSUMED) 5. SPECTRAL RESPONSE COEFF (Sps): 0.864 6. SEISMIC DESIGN CATEGORY: D 7. LFRS: WOOD SHEATHED SHEARWALLS 8. RESPONSE MODIFICATION FACTOR (R): 6.5 9. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE GENERAL 1. ANY DISCREPANCY FOUND AMONG THE DRAWINGS, THESE NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO THE DESIGNER, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTORS RISK. 2. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT DRAWINGS. 3. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ERECTION BRACING, FORMWORK, AND TEMPORARY CONSTRUCTION SHORING IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES. ANY DEVIATION MUST BE APPROVED IN WRITING PRIOR TO ERECTION. 4. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY DEVIATION MUST BE APPROVED BY OSHA PRIOR TO ERECTION. 5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION PROCEDURES. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND BE RESOLVED PRIOR TO PROCEEDING WITH THE WORK. 7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ENGINEER. 8. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED OUT 9. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE ENGINEER SO THE PROPER REVISIONS MAY BE MADE. MODIFICATIONS TO CONSTRUCTION DETAILS SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL BY THE ENGINEER. FOUNDATIONS 1. THE FOUNDATION DESIGN IS BASED ON THE RECOMMENDATION IN THE INTERNATIONAL BUILDING CODE. FOUNDATION WORK SHALL BE PERFORMED IN ACCORDANCE WITH CHAPTER 18 OF THIS CODE. 2. THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES: ALLOW. SOIL BEARING 1500 PSF SOIL FRICTION .35 EQUIV. FLUID PRESSURES ACTIVE PRESSURE* 35 PCF PASSIVE PRESSURE 250 PCF 3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 12" BELOW THE UNDISTURBED GROUND SURFACE OR TO FROST DEPTH. ALL FOOTINGS SHALL BE FOUNDED ON COMPACTED FILL OR UNDISTURBED NATURAL GRADE UNLESS OTHERWISE NOTED. 4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING SHALL CONSIST OF THE EXCAVATED MATERIAL AND/OR IMPORTED BORROW AND SHALL BE FREE OF ORGANIC MATTER, TRASH, LUMBER, OR OTHER DEBRIS. ALL WALLS SHALL BE ADEQUATELY BRACED PRIOR TO BACKFILLING. FILL AND BACKFILL SHALL BE DEPOSITED IN LAYERS NOT TO EXCEED 8 INCHES THICK, PROPERLY MOISTENED TO APPROXIMATE OPTIMUM REQUIREMENTS AND THOROUGHLY ROLLED OR COMPACTED WITH APPROVED EQUIPMENT IN SUCH A MANNER AND EXTENT AS TO PRODUCE A RELATIVE COMPACTION OF 90% OF MAXIMUM POSSIBLE DENSITY AS DETERMINED BY ASTM D1557. HAND TAMPERS SHALL WEIGH AT LEAST 50 POUNDS EACH AND SHALL HAVE A FACE AREA NOT IN EXCESS OF 64 SQUARE INCHES. HAND TAMPERS MAY BE OPERATED EITHER MANUALLY OR MECHANICALLY AND SHALL BE USED WHERE LARGER POWER DRIVEN COMPACTION EQUIPMENT CANNOT BE USED. STRUCTURAL FILL OVER 12" DEEP SHALL COMPLY WITH A GEOTECHNICAL REPORT. CONCRETE 1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD ROCK TYPE (150 PCF) AGGREGATES SHALL CONFORM TO ASTM C33 WITH PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN 0.05%. 2. ALL CONCRETE DESIGN IS BASED ON A 28 DAY COMPRESSIVE STRENGTH (fc) OF 2500 PSI. WHERE 3000 PSI CONCRETE IS REQUIRED BY THE BUILDING DEPARTMENT FOR WEATHERING PURPOSES ONLY, NO SPECIAL INSPECTION IS REQUIRED. 3. CEMENT SHALL CONFORM TO ASTM C150, TYPE I, CSA NORMAL 4. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. 5. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI 301. 6. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF FIVE (5) DAYS AFTER PLACEMENT. ALTERNATE METHODS WILL BE APPROVED IF SATISFACTORY PERFORMANCE CAN BE ASSURED. 7. CONCRETE CAST AGAINST GROUND SHALL HAVE 3" MIN. COVERAGE OF REINFORCING STEEL. 8. PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED. 9. CONCRETE MIXES SHALL BE PROVIDED IN ACCORDANCE WITH ACI 318 (WHEN STRENGTH DATA FROM TRIAL BATCHES OR FIELD EXPERIENCE ARE NOT AVAILABLE). CEMENT CONTENT SACKS PER LBS/CUBIC YARD CUBIC YARD F'c (PSI) (MINIMUM) (MINIMUM) 2500 (no special inspection, 470 5 see note A) 3000 517 5'/2 MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. NO MORE THAN A 1" PLUS TOLERANCE SHALL BE ALLOWED. A) WHERE SPECIAL INSPECTION IS NOT REQUIRED UNDER CHAPTER 17 OF THE I.B.C., CONCRETE SHALL HAVE A MINIMUM CEMENT CONTENT OF 5 SACKS PER CUBIC YARD OF CONCRETE. B) DESIGN MIX (OTHER THAN AS SPECIFIED IN THIS TABLE) SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TWO WEEKS PRIOR TO FIRST USE. REINFORCING STEEL 1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 (fy = 60 KSI) FOR BAR SIZES NO. 5 & LARGER, GRADE 40 (fy = 40 KSI) FOR NO. 3 AND NO. 4 BARS. 2. ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON THE PLANS. WHERE LAP OR SPLICE LOCATIONS ARE NOT SPECIFICALLY INDICATED ON THE CONSTRUCTION DOCUMENTS, LAPS AND/OR SPLICES SHALL BE 42 BAR DIA AND BE WELL STAGGERED. FRAMING LUMBER 1. FRAMING LUMBER SHALL BE HEM FIR NO. 2 FOR STUDS AND JOISTS, DOUG-FIR NO. 1. FOR BEAMS AND POSTS. GRADES ARE TYPICAL UNLESS OTHERWISE NOTED ON PLANS. LUMBER TO BE GRADE MARKED PER WCLIB SPECIFICATIONS. 2. ALL LUMBER EXPOSED TO WEATHER SHALL BE PRESSURE TREATED, CONFORM TO THE AWPA, AND BEAR THE QUALITY MARK OF AN ACCREDITED ALSC INSPECTION AGENCY. 2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD OR OSB, EXPOSURE 1 SHEATHING CONFORMING TO EITHER COMMERCIAL STANDARDS P51-83, APA PRP-108, OR VOLUNTARY PRODUCT STANDARD PSE-92. PROVIDE A MINIMUM OF %" EDGE DISTANCE ON ALL NAILS AND Y" EXPANSION JOINT BETWEEN ALL PANEL EDGES. MINIMUM SHEATHING REQUIREMENTS ARE AS FOLLOWS, UNLESS NOTED OTHERWISE ON THE PLANS: 3. NAILING SHALL CONFORM TO CHAPTER 23 OF THE INTERNATIONAL BUILDING CODE UNLESS NOTED OTHERWISE. USE COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE. 4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. 5. PROVIDE PROPERLY SIZED WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. 6. PROVIDE 3"x3"x0.229" WASHERS AT ALL ANCHOR BOLTS, UNLESS NOTED OTHERWISE. 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS %s' UNLESS NOTED OTHERWISE. LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO 60% OF THE NOMINAL DIAMETER OF THE LAG BOLT UNLESS NOTED OTHERWISE. 8. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH)/2" MINIMUM DIAMETER BOLTS SPACED AT A MAXIMUM OF 48" ON CENTER. BOLTS MUST BE EMBEDDED A MINIMUM OF 6" INTO CONCRETE OR MASONRY. SEE PLANS AND DETAILS FOR SPECIFIC REQUIREMENTS WHERE APPLICABLE. City of Federal Way Building Division APPROVED 7FONSTRUCTION Date: ABBREVIATION LIST A.B. ANCHOR BOLT ACI AMERICAN CONCRETE INSTITUTE AITC AMERICAN INSTITUTE OF TIMBER CONSTRUCTION SIG �31;1 r - - - ANCH ANCHORAGE Q ARCH ARCHITECTURAL EuteMotor titau F ASD ALLOWABLE STRESS DESIGN ASTM AMERICAN SOCIETY FOR _ I TESTING AND MATERIALS BM BEAM BP BASE PLATE BRG BEARING CIP CAST -IN -PLACE J CL CENTER LINE CMU CONCRETE MASONRY UNIT CONC CONCRETE CONT CONTINUOUS DF DOUGLAS FIR DIA DIAMETER DIAG DIAGONAL TENT OF � DL DEAD LOAD SITE S DP DEEP P, I EA EACH �w•• / EF EACH FACE EL ELEVATION / EQ EQUAL EQUIP EQUIPMENT (E) EXISTING = FLR FLOOR FS FAR SIDE { FT FOOT - - - - FTG FOOTING :3'r'i iit i:;' P'-= '=r SW Campus Dt ® SWCtrnf GA GAUGE GALV GALVANIZED GLIB GLU-LAMINTED BEAM GYP GYPSUM HF HEMLOCK FIR HORIZ HORIZONTAL INCL INCLUDE K KILOPOUND L ANGLE 'V L ILL LIVE LOAD LLV LONG LEG VERTICAL ssualztt'sr � Federal Way LSL LAMINATED STRAND -n LUMBER .ri LVL LAMINATED VENEER N s�'sztivr:_Y Sa2C1hSt LUMBER r MAX MAXIMUM MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURER SITE MISC MISCELLANEOUS LOCATION ,.,r'° MIN MINIMUM .�'" swc f NS NEAR SIDE NTS NOT TO SCALE S~ Iz OF OUTSIDE FACE 76 ^ PCF POUNDS PER CUBIC FOOT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH _ stivss6sc PT PRESSURE TREATED QTY QUANTITY '610th"-t REINF REINFORCING Wild Waves Therne - Lakeland RF ROOF &Water Park- South SCHED SCHEDULE s' SF SQUARE FOOT SHTG SHEATHING SIM SIMILAR SLV SHORT LEG VERTICAL SPECS SPECIFICATIONS SS STAINLESS STEEL STD STANDARD STRUCT STRUCTURAL T&B TOP & BOTTOM T&G TONGUE & GROOVE TOB TOP OF BEAM TOF TOP OF FOOTING TOS TOP OF STEEL TYP TYPICAL ULT ULTIMATE U.N.O UNLESS NOTED OTHERWISE VERT VERTICAL W/ WITH WF WIDE FLANGE W/O WITHOUT WT WEIGHT WWF WELDED WIRE FABRIC RECE AUG 13 Pavilion Apartments Deck Replacements 1900 SW Campus Drive Federal Way, WA 98023 Owner: Prime Management Group Architect/Designer: NKH Engineering 914 N 89th St Seattle, WA 98103 p: 206-601-9728 e: nabilkh@gmail.com In Structural Engi NKH Engineering rtr @2018 NKH Engineering These drawings are the property of NKH Engineering and are not to be used or reproduced in any manner without prior written permission. Revisions: Issue Set: Permit Issue Date: 4/26/18 Drawn By: AKR Checked By: NKH Sheet Name: GENERAL STRUCTURAL NOTES Sheet: S1 0 O 0 D M p m o A MMm - �Yro o oo �ANW °0(D N z -a n co U -o ID 3a 3:i� ,., ti 0 c� V