Loading...
19-100807 r -Sign City of Federal Way Permit #:19-100807-00—SG Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: TARGET AT THE COMMONS Project Address: 2201 S COMMONS Parcel Number:762240 0019 Project Description: Installation of(4)internally illuminated wall signs. Includes electrical connection to existing J- Boxes. Owner Applicant Contractor TARGET HEATH NORTHWEST INC(ELECTRICAL HEATH NORTHWEST INC(ELECTRICAL 2201 S COMMONS 04) 04) FEDERAL WAY WA 98023 727 S 96TH ST HEATHNI981JZ(4/9/20) SEATTLE WA 98108 727 S 96TH ST SEATTLE WA 98108 Wall Sign Information Reg.# Sign Type Illuminated #Sign Sign Face Sign Face Building Faces Width(Ft.) Height(Ft.) Elevation Sign A N/A Channel Letters Yes 1 14.00 15.00 North Sign B North Channel Letters Yes 1 14.00 15.00 East Sign C N/A Channel Letters Yes 1 14.00 15.00 South Sign D N/A Channel Letters Yes 1 7.00 2.00 North Additional Permit Information Comprehensive Plan Designation City Center Core Zoning Designation CC-C PERMIT EXPIRES Wednesday, 11 December,2019 Permit Issued on Friday,June 14,2019 I hereby certify that the'above information is correct and that the construction on the above described property and the occupancy and - s- , Il be in accordance with the laws, rules and regulations of the State of 'ton a • the Ci• - -deral Way. r Owner or agent: Date: l Nil — r- 1 levok-) ' A' „ . THIS CARD IS TO REMAIN ON-SITE CITY OF Construction Inspection Record Federal Way INSPECTION REQUESTS:(253)835-3050 PERMIT#: 19 100807 00 Address: 2201 S COMMONS Project: TARGET FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible _ (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Footings/Setback(4110) 0 Final-Electrical(4055) ' 1=1 Final-Sign(4085) Approved to place concrete Approved I Approved '� 1/e // '/, 13 ,By Date .'.By /� Date/A,—�3 / �;By Date //1.7 Attachment(4010) By � Approved � Date e /l I/,, Rough Electrical 0 Final ElectricalEl Right of Way Approved Approved Approved By Date By Date By Date RECEIVED e , % 44k,..., cal( OF ' FEB 2 0 2019 Federal SIGN PERMIT Eivr '1 ede al WaJ M�N1T1'DEVELpptijY APPLICATION PERMIT NUMBER ` / - / 0 0 ? O 2 - 5(�7 TARGET DATE 3e0 0// SITE ADDRESS V 1 SQ c601011-3 k,f o t /O,i I, P^_ Qs-x-0 BUSINESS NAME ON SIGN `1;421-761r. ASSESSOR'S TAX PARCEL# 1 (I9 -4/ 0 - 0 6 / 9 ZONING DESIGNATION C C - ELECTRICAL INCLUDED(Attaching to existing J-box) Yes No PROJECT VALUE $ IO 4030 DETAILED PROJECT DESCRIPTION 'ns.1-tu tnapt d!::. •174,0,,T i"JCLL �- t yic SIGN OWNER: NAME PRIMARY PHONE 7741% 1— (02515) -i -75;20 MAILING ADDRESS FAX NUMBER 23ct 3.Co nA/ .s ( ) - CITY ����� �� STATE ZIP CODE E-MAIL ADDRESS tv4— 96c-W5 CONTRACTOR: NAMES n( aj► N Or��I/ VS S�-- OFFICE PHONE E (Vito) f - /026' MAILING ADD ESSS q r CELL PHONE -12-� ( ) R - CI�'Y n` ST ^` ZIP�pDE� I E-MAIL J7vul(eiN,4 „r ICrYr,lI.I.0, WA TATE CONTRACTOR'S LICENSE: P/! EXPIPI3RAAATTTIIONQpATE: FFDJRAL WAY BUSINESS LICENSE: L 0i4 Rel J-1'\J.Lct1 1 zo -o4-i-/a75 cocky- 34_ APPLICANT NAME1 PRIMARY PHONE CiZ-gc i74'(.., CAN t ' (20(p) €B - 3/do MAILIN ADDRESS FAX NUMBER �' fi �►el+ ( ) _ it, -eittIi it1A)14— ay STATE ZIP CO4W E4litDe.Sci oakwes[ 010 PROJECT NAME, ( PRIMARY PHONE E-MAIL ADDRESS: CONTACT C {` C02 ( omo()Le25 -J`Ct 6 1-02lc d-A N m7ut Lc6p� �"1 I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of t, ••ove prem' : taper • .. he work for which the permit application is made. SIGNATURE - DATE: t/26///91 ..f 2L\/// C/ 7-7 PRINT NAME CR-\1p-I PERMIT CENTER+33325 8r, AVENUE SOUTH+FEDERAL WAY,WA 98003-6325+253-835-2607+FAX:253-835-2609 +permitcenten :citvoffederalway.com ►� Ak,. PROVIDE THE FOLLOWING INFORMATION FOR EACH PROPOSED SIGN: FREE STANDING SIGNS SIGN TYPE SIGN AREA ILLUMINATED? LANDSCAPING TOTAL BASE (Monument,Pedestal,Pole) (#of faces x 2) (square feet) HEIGHT HEIGHT A B C SUBJECT PROPERTY'S FRONTAGE ON PUBLIC RIGHT OF WAY(LINEAR FEET): BUILDING MOUNTED SIGNS SIGN TYPE SIGN AREA ILLUMINATED? BUILDING ELEVATION EXPOSED (Cabinet,Channel Letter,Awning,etc.) (N,S,E,W) BUILDING FACE A a06,ofk.10 ISS i l� u —� i '7 - B C h_ct.v\v, ( 53.1 D --- J p c,ho l 1 2\di1 LE,'- IBJ /// ' To2 LARGEST EXPOSED BUILDING FACE(SQUARE FEET): /1/ g v Pi EXEMPT SIGNS SIGN TYPE SIGN AREA SIGN HEIGHTNUMBER OF (Directional,Instructional,tenant panel,etc.) SIGNS E-1 E-2 E-3 E-4 E-5 Bulletin#102-May 3,2016 Page 2 of 3 k:/Handouts/Sign Permit Application RESUBMITTED DEPARTMENTOP Co1xiuNrry DEVELOPMENT 33325 8'h Avenue South CITY OF APR 15 2019 Federal Way,WA 98003-6325 253-835-2607;Fax 253-835-2609 Federal Way CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT www.cityoffeder3lwaycorn RESUBMITTAL INFORMATION This completed form MUST accompany all resubmittals. Additional or revised plans or documents for an active project will not be accepted unless accompanied by this completed form. Changes to drawings must be clouded.Applicants will be required to affix the city's date stamp on each page of resubmitted plans and to collate loose plans into existing plan sets. You are encouraged to contact the Permit Center prior to submitting if you are not sure about the number of copies required. Project Number: 19 - t o 000 -1 _ Project Name: yr Project Address: Wr) l� 9 Ci �)��1 � recefit• Ativr qe)v" Zra Project Contact: l� 3� Can CR,' Phone: .261(1_ . - l' () Email C ,'S Ce aJ l�'1��lh � it RESUBMITTED ITEMS: #of Copies I DETAILED Description of Item t octd 'avz l`.'' O'tt5 c to .. C .L - S (J c,5 20 - Cs.17— 7 t(56 Resubmittal Requested by: r Letter (St- ember) OFF/CE USE ONLY C RESUB#. , Distribution Date: �-7� /9 By: , 41. Dept/Div Name # Descri tion x/Building0,441(3._ Planning PW Fire Other Bulletin#129—September 24,2018 Page 1 of 1 k:\Handouts\Resubmittal Information PERMIT#: 19-100807-00-SG ADDRESS: 2201 S Commons PROJECT: Wall Signage TARGET RESUB: 4/15/19 CV w � ` ` d1 ! ` ' t!..2 � It>J - 5 ,_ o a 2 2 .O F H i--;'. N r Z Z Z H H H W o Q1 LL u LL ,� 000 u- co ,_lo � c u"� = Cf C d Q O'Q Q 6 C Q C7 Q W• C ' Q !� w0 O •rGJ O Q. G a O �' co to v, CO vnI>>> va ' N O > w ■.■ 1L` O _. •,, - ryV N L N Cn W W W � J N dra J Q1 D E 76 � D L ,� ad - ti oi t0 N N C^J W W W W CD W W C•7 ,, .° O _ .+ h 2 11'7 I (D 2 Q1 LL'Y !— F— eal 1— •.— M /A Oi 4•. O .r _ �,;J M O r N r W N {.7 07 SQ pi wCC dWp C7 wN a N h N rc Iy 0 C Lj C7 O cz W p W O c CO ce W O°b Z N J W J C C co za- N CV.0 0m x m CO NO > 2 hJ J J 0, CN C W O C ari 0 _cc ila O1 CC cc G H 03 LI a) OW W ` . In cc O C+) CD WX20 O ao O —�CLI W O ? F tq F Wf'=' - I- N Z W O Q cc Q M Q E J OC C i c. W F of W Li" "' pp -UJ LU—1 W O p >, 7 Z - -. OWQ Y F W F 7' J Q �'.. L7 O Z o w `w a W -5 GI QE LU in V C7 F-H F- Q LL -' W d LU G7 O Q W Iiii W Jo CC a'r- m = a = of p bC a' CO eeeel W 2 W N e0 G N O W Q 1 N J O > it \ >. O CI hZ 2 2 Z Q n cc 000 U12 .0 2 Z CO W W V aO 0 0 0 \a CO CO = J v ol0 :,3. Cs CO :I E-0- O CG c o °WC _._' tt � Q Q O� 'Ed i t r•' .-+ y co O W O r- N v W vCC Q , G = N 2 12 3 W CC z T EG N Z ~ I� \ 0 � Q 2 r oo = o W ='; W O O p S O r FC .,2 LLJ fl4c WI III i>c Z y a Km x = GO 3', ¢ 3cu ¢ El w a v W 0 W O C7 W� Z W Q -Q r LI— W p M. Z O \, S co, p m I:3 8 W —y o C 'Vo +u- C _ •OF Clio C No ] r.� K'.. t*, gwx dL1 ! T,` = 2 N SCS 2r Air ; 7 Z z i i i 'IA "O •O QQ iii It1011004441, Y !!:� .. ...:- 1 : r-**.'1 r- 44.N ggts, t 1 %.. tir:11 ' ...v. ' i.4 ; 1 i I;1 1 y,'*:, 4 411* I* t*: ,ig iik t olo . � ... es ti .... t 3 2 . % AI "11 ,,,, • virti: It al 2 ' a •N '4141 It I. , 401;,4 '..z.:: . .. < < .. 1 i - <,.. <, 1 ,.....<3,4 ! .'.; !, la 41 warn "� ,, , 0 { i �> , — .X 2 pmfiii rryx Mll11 N. M t �, i , tj Asap f . . ,; 4f IP _ „ .„ 4 - e s 1 +1►.ryt I 2�.. Omi r . ;.'rte* -, f, 3 1 17 2O s , .rrj '",', ...,,, ,:1. , 4 4 Ir 10.., 1,„, klit ` T " C Z -j c bi° �rw.,. 1 - rN :.'4 43 O i* . I:WA:* t--r-- l'''.. . t ' *j4.6 ,,,* ' '- 4 ' * i.1 ,. i -_, ‘7‘ • tk 4 _ ••*,,,,I ii.il• . 16": —‘A""(11 C— - - ''t i °6 e 8§i 1 = ;041 a 11: - > top. or " : . a f Ili _r � 4 4:„.111171:: '' Ell11111b_ J ON P.. N_ ::II: �� U as III .460/0 *r ,, ; t 14; ,. . .4. . 1„4 r i+ , 1:1 4 , =,,, . x.. ,t .v , , IIILlII l3pl: gU1 3 . . 4 /.## f* „ie ._ ,e, \ t , F— ,. z Z ill NM 5 a 394'-8" Al — _�,r� .� .� rcvsehrmxy —TAR ET — , 'J `1 i>• I�(/!�1 v e i Mil m Ile EXISTING FRONT ELEVATION Scale: 1/3211=1'-0" 4 Al . — :....:4, 4. „ ,... ... ...... „ , . ..... .....Y _........ .,. r_____. „. , . ..t. .., „., ..... _ . , . .... .. _ _ ..... r , EXISTING CONDITION OF FRONT ELEVATION NTS A2 ®TARGET ..t.... METAL FINS_ _ - - IIII ... .inittele" M ARE 4ir bad` - ..- \i ♦: s —. ' ,„„ . ra,, , poilm.... AIMPIFfn-ED -.._ APR 15 2019 EXISTING CONDITION LEFT ELEVATION EXISTING CONDITION REAR ELEVATION EXISTING CONDITION INTERIOR CNTS NTS NTS Mu°mY FEDERAL n” saa1010.1111WWW, ....NWS r FEDERAL Miff; 95017779Y0.1ll Atmore afa 1111-07-IR JA Upd.i ekMon addd.i:ni G 9 9 �' Pru ecT/lpcaaon lois original praV,nn Man,raaonnq PaNnrts4r, - --- Account Rep. Boyd Hippenstiel is provided as par; of a ri OceansiAe G-Euless TX ladaonvilk.T% RS 01.79.�91G Upde,e p”saner aiv oewwa,._ Locations w V11.Ir.IRNuotuµm...,.: : Job Number'. 23-50182-10 HEATH Alaina Luciano0 planned project Office LH,Racine t317J6.1/YLI700.Update Ekmfa d IkdSpnN landRn Sipl. QU1t.%i6R.M 1 pfOJPCt�rlarkigef'. October 9 201 B and is not to he rociu ed, Oceanside,CA Las Vegas NV•Latphbn,AZ 1)ate , copied or reproduce° Idaho Falls.W Euless.TX.larfson"Ne,TX•San Anton.TX 1401;;41111D/JeR Update,Icans/g 9 rel(Sign IMO 1/1734111.19 Y4CKRetina S pa a ln'r Naga oawndy, Jesthan Delcano/JDR VISUAL COMMUNICATIONS HnudonTX enrpisThom TX IntbaropoOTw without me written lauivige ICY Xrasslnlo TN Gralmn 1N Delaware.OH C.,lor.On paten.ir,rI o F, JI,FIG Ma)•NO[Ma[CnACTUJI Finished MATCIla1S Re for To Product Samples For Exnet Color Melrt' C ELECTRICAL TO USE UL rI5TE0 Store: #Tl 947 www.FederalHeath corn WiI,UwOrook,IL Tunaa,MS-AUana.GA U1 Underwriters nec bMPONENRANOSIWLMEET SneelNumber 2 F pe e rn I s s 1 o n o f Tampa.Fr Daytona eexb.rL.OnasJc n Client Approval/Date: Laboratories Inc. r qRt N.R C STANDARDS 2201 SEA TAC MALL BLVD Federal Heath Sign 460Z North Avenue Oceanside,CA 92056 a EI Ac At Tl0Na Aa To WITH u r . A ALL �" OP THE N COMPLY INCLUDING =G,v FEDERAL WAY,WA 98003 Design Number: Company, LLCn or its (760)941-0715 Fax 1760)941-0719 Building Quality Signage Since 1901 LandlordApprovaUDa[e: THE Aa°.dGROUNDINGEAun BONDING a AI. I 923-50162-10-118 aumonzed agent. OFHSC . 6 vINIs ( 6) (1 1 .. c„)(15--V( iA --,b4 Pe ,,,,,i A D B C D E B G H I I J K t A ("V") © ACRYLIC STING FACEDSIGNTO INTERNALLYREMAINASIS ILLUMINATED CHANNEL LETTERS A1) SCOPE OF WORK: E SIGN TYPE A B C I Q E SU.FT. OTY CVS-24-CL 23 3/8" 18'-3 3/4" 2'-5 3/4" 5'-41/4' 9'-91/4" 36.62 1 24'-9 1/4" F - TA R G E T .- 4'-61/2" - 19'-81/4" C CVN_CO CO /V 0 D G Al A2 A3 ACRYLIC FACED INTERNALLY ILLUMINATED "LOGO & LETTER SET" �. el SCOPE OF WORK: --- REMOVE AND DISPOSE ACRYLIC FACED INTERNALLY ILLUMINATED LOGO/CHANNEL LETTERS SIGN TYPE A B C 0 E F G H 1 J j K RETAINER 101E1/letters Drs OTY © SCALE:1/4"=1' 112.5 SOFT. LL144/32S-R 12-0 1/2" 12'-01/2"2'-81/4" 13'-103/8" 15'-91/2" 13" 2'-01/2" 1'-11 1/2"i4'-01/2"1'-111/2" 2-01/2" 1 Y"RET./1"It 113.1/37.0 3 SCOPE OF WORK: �+ EXISTING SIGN TO BE REMOVE AND REPLACE. RESUBMITTED APR 15 2019 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT � Revizlori` AS 0112-19 RAM Remove Sign hom P"rAter MarwtaaumgFad"Ues Rnl.oraalP Upond ekrcmn and added im tint ) C:LCLL:r This original drawrn0 A6ol Account Ret, Boyd Hippenstiel N Oceanside Delaware.-E OH Rain<'sw,•Nk.TX 2A-14)6(Wok PerwMT ni° IS provided a5 part Of d HEATH off Ram,e'WI �1, IA/0.ltl,urb' 0 Job Number 23-50182-10 Office a, q12-06.18 YMCA UPddr FkroAnm RRd oddnd Slln e,lmdlk.SIP l A7p131;1916 Remora nm9 nobs Project Mrtttsitdt" Alaina Luciano planned p r o�e c t tale. , tr t is Vegas.ti �„cr",Ar rr October 9 2018 and is not to he exhibited. Jesthan Delcano/JDR °� bh F tD F Tx-ld di �( SanAry,nH.TX A/e1-16191UIIOR Update,lonm/sirRge rsnAred(Sigh Mil) A)U2-0614 VA(CH[Keeled 5�9nlehjunihed Drawn H. r Copied or reproduced VISUAL COMMUNICATIONS Newton]X pus(Nish,TX•ir,ar pohs.IN without the written Louisville,Kw Kewanee 1N•C R WI-Delaware OH Colors Ocplcred In This RCndCrm9 May Not Match Actual Trashed Marcrmis Refer To Product Samples For Exact Color Match E1.ECTRKAI.TO USE U L USrED Store: #T1947 Underwriters Sneet Number e r m i s s , o n o f www.FederalHeath.com wi" oky-n MS Mama 6. coAwDNTmANDSHAuNEE 3 p Client Approval/Date: LaboratorleAlnc. All N.E C STANDARDS 2201 SEA TAC MALL BLVD Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 All ELecrelco,sreN,ARe TO COMPLY WITH u L. Company, LLC or its (7601 941-0715 Fax(760)941-0719 Building Quality Signage Since 1901 Landlord Approval/Date: THE'PROPSa°�ROUNDIN°`AROSTANDARDS, BCNO N�o.INCLUDING .°S,G'Ns FEDERAL WAY,WA 98003 Design Number: 23-50182-10-R8 p y' authorized agent Q9fHSC 394'-8' (si 14'-0" ENKE 18'-3 3'4 t'-8 112 GS 3,18^ 14'0" • a Milill Ili GIA, ST'G DIMS "C"°° =,,,:„ ...,. ii•is.... ....,it : : : : : i girt 13, �„ ; fl Icy map_I_/i E 1.2.�s I i 1,�� I• in Ig/ 1•p i■ i �1M1f�.• ids 1.�� -T- _11 It UM__ � . Front Elevation scat r ' - Nog,_,--.0, EBF_ 11,34a0 c — 1.W 0 EXTERIOR MATERIAL FINISH KEY: SSP-� 5`f 0 + � —C-1 RED C-45 SW 7033 BRAINSTORM BRONZE C-10 BM 1037 MUSLIN C-23 VALSPAR"BRIGHT SILVER" C-11 BM 1039 STONE HOUSE (E)INTEGRAL BLOCK _____] 355' 2"± EBF, 10 1100 an14'-0„ 5��` )a D0 gin SAP.= ► 5 0 1......m.--- _____ ...NW ____ El 1 r .. ., .. , ,",.., ,, , 14'-0" ..:. 01 71 rIIIMIMIIIIIIIIIIIII illIlli Mill rg-7....11,- i 1 ■ ■ • ■ ■ • ■ . • ■ ilow • 1 t•tiX31 ED81 Yf��fl I ..I m. ■•I I•t... Ig emo. ■•2• ■a. ■.tg me ■IMEO ■a o11111 HMI! Left Elevation SCALE' 1,'32 . ESUBMITTED -E___ teeprsT APR 15 2019 pi FEDERAL I< RS Sign 1 ,' T . T• •I • /'win ManuraclWln Fanx�es eln-07:elrupmMd Dodger and dwd-I,�gRc Boyd Hippenstiel g 9 ----_ _..— Account Fr. oceanside CA-Euless Tx lacksonvale Tx gaolTg roicupa� o r i IS provided as part of a [)eldWWe oH-Racine VA I 15 ll:(lbs.�..E• I<,:..,.1,,�, 0 Inn Number 23-50162-10 planned project HEATHIOIna Luciana _ Project Manager:er. r)hce Locations g71[.OD-Ie vurog GNP gk.auoN and died sign x.l and Novw"slrnl alolal.Ig,c hoot , I 1 and is not to be exhibited, - a"""""CA Las ""' `""y`"""Z tate October 9,2018 copied or reproduced Idaho Falls,to Eales,TY la:laonalle Tx San Antonio IX 140776IS 0/101 Upda"IcnolgnoC red lSIgnl NCI 170-0 S Will(Roos g -1111 1 d Drawn By Jesthan Delcano/JDRwithout the written VISUAL COMMUNICATIONS HOUGOrlTX.cmpusChoSOIX-Indianan.,IN lou.tville,NV Y.now Ile.TN•Grafton wr Delaware oil -,epic e� h 4 �,p r nr:,I r..r March Aclua F n.heo Mar. ol: kerb/TX roducr Se nples I or Fkavt at,„`,1, F ELECiPICK!O USE Ut I/STED Stare: #T1947 www.FederalHeath corn Sheel Number: Willowbrook a Tun.MS-AlkrKa GA Untlerwrft°rs nee COMPONlNiS AND SNNL MSFT p e r m i s s i o n o 4602 North Avenue Oceanside,CA 92056 amuaFLoan.'LrG.mEL-Orlando.FL ,.iientApproval/Date. Laboratories Inc. s Att N.tE STANDARDS 2201 SEA TAC MALL BLVD Federal Heath Sign L ELECTRICAL SIGNS APE TO COMPLY WITH 41 t.Q ANO Company. LLC or its 1760)941-0715 Fax 17601 941-0719 BuildingQualitySI na a Since 1901 •TIC LP EAM a• INS N.a.G atANOAMN,INCLUDING FEDERAL WAY, WA 98003 ''_siyr11v11:1.1;(�� 9 9 Landlord Approval/Date. :..E PMO••*°MOUNDING ANO MON°IN0 01 ALL SIGN: 23-50182-10-R8 autnorzed agent CFHSC c95,-3-I 2r-4" 14r4" - -19 , I� . ::.• ,. ,„ ..:4 - 13'-9" „ i I I I I :�:'� >.1 __ '�__ -'moi . ...... ... ... R•11� ■•� ■u/•r .��0SAMIN 1.1 - ■812 4Ifffft•1 ■��1M.S vs uY,>tar��—r'�I. alb ilawommoc Rear Elevation SCALE. 1/32`=1' 5 .. D (-7 €BF = I 1)250-.0 /5/4/1- a`�D EXTERIOR MATERIAL FINISH KEY: A-f: y _C-1 RED C-45 SW 7033 BRAINSTORM BRONZE `/ C-10 BM 1037 MUSLIN C-23 VALSPAR"BRIGHT SILVER" C-11 BM 1039 STONE HOUSE (E)INTEGRAL BLOCK • EBF-7 • 4'-41 slilt=AJ/'/4 10'-81/28'-91,4' 5 '12 I n*ma i . , ____a_ 1 5.-0..k— Q target19 mi moo •• : MATERIAL FINISH COLORS 4 B ►) 1 JWHITE I I 8 WHAT732UGLASITE ( iyVHITE I iLs who Acrylic Returns Faces Relainer,?rim-Cap Illumination 4- C --ai4- D ►14 E t F --+�.- G -►I 6„ SPACE MAXIMUM 1" SPACE MAXIMUM 1" r— MINIMUM 1/2" i-il MINIMUM 1/° 6"�J WALL /i I • • • A Y J 080 ALUMINUM FILLER • INTERIOR PAINTED WHITE O EXISTING ALUMINUM RETAINER '� ELECTRIcru IT n PANEL • MINIMUM 090 ALUMINUM BACK PIGMENTED ACRYLIC FACES ----.....„‘I 1I LO —. ' SLOAN LED-- ! air r 11110 %'ELECTRICAL BEYOND SIGN!.. '!e A (, LOCK-ABLE DISCONNECT— BY INSTALLER I, ( SWITCH BY OWNER-WIRED ~� Ir-r-'"1I INSTALLER TO PROPERLY SEAL WALL, 1E/_I BY ELECTRICIAN ----..._//a...` '►1. I • SEALER:BASF-MaslerSeal NP 150 p• C••Cr OPER CIRCUIT! �, • • iii I •� �. D. / Q•80X BY INSTALLER i ALL MOUNTING HARDWARE(INCLUDING SPACERS) ITV f-/ TO BE SUPPLIED BY:INSTALLERitr ' f POWER DISTRIBUTION BOARD-- i .....- L. MINIMUM 3/8"STAINLESS STEEL MOUNTING HARDWARE 4 d , �, ! 'T �AI LE BY:FEDERAL HEATH ... Z 1 +d"1•^1 *_ V Q -- = 12 V CLASS TWO POWER .-- � ~ p d .--- . SUPPLY SUPPLIED BY: c; • (2)-WEEP HOLES PER LOW SPOT-- L D FEDERAL HEATH y a - MOUNTED 8Y SUB-CONTRACTOR -. -----_.._ CLASS 2 SECONDARIES TO DISTRIBUTION BOARD _ TO BE RUN THROUGH CONDUIT SUPPLIED BY i(/JaniBu uuu"ttlanntIIIIII HO' all i u Hp"gUtnt tHun6itiit=' INSTALLER AND WIRED BY INSTALLER. DISTRIBUTION BOARD AND POWER SUPPLIES r,I SUPPLED BY FEDERAL HEATH SIGN CO. LOGO//WALL DETAIL NOT TO SCALE END VIEW (Generic) CUSTOMER TO PROVIDE NEW 8 REMODEL CONSTRUCTION p ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE" DEDICATED BRANCH CIRCUITS FOR ADEQUATE BEHIND THE WALL BACKING AND SIGNS ONLY PER NEC CODE 600.5 ACCESS IS REQUIRED FOR THE INSTALLATION ALL BRANCH CIRCUITS SHALL BE DEDICATED TO OF NEW SIGNAGE CUSTOMER TO FORWARD SIGNS(INCLUDING GROUND AND NEUTRAL)AND APPROVED SIGNAGE DRAWINGS TO THE ON ----�-"` — SHALL NOT BE SHARED WITH OTHER LOADS SITE CONTACT TO INSURE THAT THE REQUIRED SCOPE OF WORK: INSTALLATION OF THIS SIGN SHALL CONFORM ELECTRICAL REQUIREMENTS PROPERLY SIZED GROUND WIRE THAT CAN BE PROVISIONS ARE MADE DURING CONSTRUCTION MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED TO ARTICLE 600 OF THE NEC,UL 48 AND OR TRACED BACK TO BREAKER PANEL IS REQUIRED PRIOR TO THE SIGN INSTALLATION OTHER APPLICABLE LOCAL CODES,INCLUDING Total: 0.0 Amps INSTALLER REQUIREMENTS INSTALLER REQUIREMENTS FOR EFS WALLS NOTE: ON A PAINTED RED WALL THE PROPER GROUNDING AND BONDING OF THE SIGN. ALL MOUNTING HARDWARE, SECONDARY ITIS THE RESPONSIBILITY OF THE INSTALLATION WIRING AND CONDUITS ARE TO BE PROVIDED CONTRACTOR TO PROVIDE ANY WALL SPACERS THE LOCATION OF THE DISCONNECT SWITCH,AFTER INSTALLATION BY THE INSTALLATION CONTRACTOR REQUIRED TO KEEP TIES WALL MATERIAL FROM SIGN TYPE A B C O E F G RETAINER SOFT OTY SHALL COMPLY WITH ARTICLE 600.6(A)OF THE NEC. (1 ) 120V 20A Circuit Required. All PENETRATIONS IN THE WALL ARE TO BE BEING COMPACTED DURING INSTALLATION OF SEALED WITH SILICONE AND TO BE WATERTIGHT ANY MOUNTING BOLTS REQUIRED FOR SIGNAGE 168 BULLSEYE-W 14'-0" 14'-0" 2'-4° T-4" 4'-8" 2'-4" 2'-4" 1 %i' 153.9 3 ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH ctiiiaAt rTotc GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE •INSTALLER SHALL VERA wail CONDITION IN THE FIELD NOT BE SHARED WITH OTHER LOADS. TO OR IMPROPER OPERATION OF SIGNAGE, -np D D NOTE: ACESSS OK - CEILING CAUSING DELAYS AND ADDITIONAL COSTS. ALL AAT � �p tH :•ISOLATE ALL AI. I trArral TEE APR 152019 riFINEEDAETRAH L 601II19YAUKkemoreSNnJ' poadpe Manuraaurn Facilities A lilt- dl"*aedekraGanododdediarpnG This original drar-vino O Account Rep Boyd Hippenstiel Ottans•de,U•Euless TX Jadrsorn,Ale.ix RAeL2k.19,cnpAnlr pn.an°,iris 23-50162-1 ' "i"'AY k]li.».tem/DRUfila knanrRrlS� Job Number. Ueawae OH LonRacWI Maine Luciano flE .bEeD, Once LoraLrons R31i.M•rBYA1)Dt URYe Nw�NamaAd added*H,led MeaSWI RIM-31-191G kmwa mnsr roam Project Manager and Is nor to be exrerAted. Oceanside,CA-Las Vey.,NV-ra,yr+.,.Az0 Date: October 9 2018 wke•uwsW,. Is; ) Rr030o-Ilvu(n(/levieds,,l,J,k ,LIN Drawn Hy Jesthan Delcano/JDR _ wIcopied or reproduced Who Falls.IU Eukss,TX-Jacksonville 7%-San Mconro,h kd el.lA-I91N1W ,anrdrsd ns X11 VISUAL COMMUNICATIONS Houton Tx-CorpusCEOISI,,IX-Indranap°NS.us without the wr;tten Lows-wile,KY•Kronnae TN Gralron WI Delaware OH .•'r"S Oepsctea rn ants Rendering May Nor Mach AC[-dl I,nlshed Malen,ry Reser To I"0110(1 Samples rOr So.ir' f ULCTRICAt FO USE U t.USSEO Store: #T1941 www.FederalHea[h.cors updereMers 6 p e r m r s s l o n o T Willowbrook.F-I Pa MS Atlanta,GA -Tient Approval/Date: UE nee COMPONINTS AND SHAl1 MEET 2201 SEA TAC MALL BLVD sheet Numbet. _ a e 4602 North Avenue Oceanside,CA 92056 pa Daytona Brach.E(•°`""n°FL laboralorleclnc. f Au N e c srANOAOUo Federal Heath Sign `NS ARE ro COMPLY N"TN°L Company LLC or its (760)941-0715 Fax(760)941-0719 BuildingQuart SI na a Since 1901 ARTI LE 6 AOF'THE N F iANOARD5 INCLUDING FEDERAL WAY WA 98003 Design Number Quality 9 9 andlord Approval/Date: PROPER GROUNDING AND BONDING OF All SIGNS 9 23 50182-10 R8 authorized agent. *FHSC 1f I[, ON—STANDARDJ -STACKED 6'-8 1/2" SPACE MAXIMUM 1" $" SPACE MAXIMUM 1" MINIMUM 1/z" / 5'-5" _ MINIMUM /" 5" WALL , — `. 7 r r a'}} !! 040 ALUMINUM FILLER ' �" �` 1 PRE-FINISHED ALUMINUM O > .; i {/ ��"'� �� o EXISTING i t "i `1 CV r E—� 1"TRIM CAP ELECTRICA' + t f+ I PANEL i t ' I MINIMUM 063 ALUMINUM BACK 8.29 SQ.FT. 1. PIGMENTED ACRYLIC FACES—yam '..}- • SLOAN LED o 0 .•;' Y"ELECTRICAL BEYOND SIGN --- --..,4..I � I WOK-ABLE DISCONNECT T 1 - • BY INSTALLER SWITCH BY OWNER-WIRED ''--� R f INSTALLER TO PROPERLY SEAL WALLBY ELECTRICIAN I �: SEALER:BASF-MasterSeal NP 150 :p, p,p 6,,,,, (1 PER CIRCUIT) 4:V p •p•:41-1 -- J-BOX BY INSTALLER r------ - r /� ALL MOUNTING HARDWARE(INCLUDING SPACERS)\ TO BE SUPPLIED BY:INSTALLER ( -; ,0 I MINIPAUM 3!8"STAINLESS STEEL MOUNTING HARDWARE Q 4 ` POWER DISTRIBUTION BOARD-- 9..__..--1 I� -_---- U ` ' \7 BY:FEDERAL HEATH -_-'� f` 3 4)RC { � �� 12 V CLASS TWO POWER - [ SUPPLY,SUPPLIED BY; r WEEP HOLES PER LOW SPOT �, j FEDERAL HEATH 12.88 SQ.FT. i 1 _ 4 MOUNTED BY:SUB-CONTRACTOR = CLASS 2 SECONDARIES TO DISTRIBUTION BOARD _ __ END VIEW TO BE RUN THROUGH CONDUIT SUPPLIED BY - -----._! yr INSTALLER AND WIRED BY INSTALLER. ►:gpm7Lat't 1" eTdABu7 mo Hu „„„,„,e DISTRIBUTION BOARD AND POWER SUPPLIES ACRYLIC FACED INTERNALLY ILLUMINATED (Remote) CHANNEL LETTERS SUPPLIED BY FEDERAL HEATH SIGN CO. LOGO/LETTER WALL DETAIL NOT TO SCALE (Generic) SCALE:3/4"=1' SCOPE OF WORK: MANUFACTURE AND INSTALL CHANNEL LETTERS AS SHOWN AND NOTED CUSTOMER TO PROVIDE NEW 8 REMODEL CONSTRUCTION DEDICATED BRANCH CIRCUITS FOR ADEQUATE BEHIND THE WALL BACKING AND SIGNS ONLY PER NFC CODE 6003 ACCESS IS REQUIRED FOR THE INSTALLATION MATERIAL FINISH COLORS ALL BRANCH CIRCUITS SHALL BE DEDICATED TO OF NEW SIGNAGE CUSTOMER TO FORWARD I GLOSS F-7 7328 LD WHITE "- WHITE ` ---SNIati White SIGHS(IN(LUUIIIG URBANE AND MACTRAI)AND APPROVED SIGNAGE DRAWINGS TO THE ON WHITE I I(ATUGIOWorHITEuw` ILEA SHALL NOT BE SHARED WITH OTHER LOADS SITE CONTACT TO INSURE THAT THE REQUIRED Acrylic INSTALLATION OF THIS SIGN SHALL CONFORM ELECTRICAL REQUIREMENTS PROPERLY SIZED GROUND WIRE THAT CAN BE PROVISIONS ARE MAIN DURING CONSTRUCTION, Relures Faces Relainer/Trim-Cap IOuminaliuo TO ARTICLE 6011 OF THE NEC,UL 48 AND OR TRACED BACK TO BREAKER PANEL IS REQUIRED PRIOR TO THE SIGN INSTALLATION • OTHER APPLICABLE LOCAL CODES,INCLUDING Total: D.0 Amps INSTALLER REQUIREMENTS INSTALLER REQUIREMENTS FOR FIB WALLS THE PROPER GROUNDING AND BONDING OF THE SIGN. ALL MOUNTING HARDWARE, SECONDARY IT IS THE RESPONSIBILITY OF THE INSTALLATION NOTE: ON A PAINTED RED WALL THE LOCATION OF THE DISCONNECT SWITCH,AFTER INSTALLATION WIRING AND CONDUITS ARE TO BE PROVIDED CONTRACTOR TO PROVIDE ANY WALL SPACERS SHALL COMPLY WITH ARTICLE 600.6(A)OF THE NEC. BY THE INSTALLATION CONTRACTOR REQUIRED TO KEEP DURING AL FROM (1 ) 120V 20A Circuit Required. ALL PENETRATIONS IN THE WALL ARE TO BE BEING COMPACTED DURING INSTALLATION OF - SEALED WITH SILICONE AND TO BE WATERTIGHT ANY MOUNTING BOLTS REQUIRED FOR SIGNAGE ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH GENERAL NOTE NOTE: ACCESS OK — STARBUCKS AREA GROUND AND NEUTRAL)AND SHALL REQUIREMENTS .MAY RESULT IN DAMAGE N 5 yB�,,�p, n GC TO PROVIDE ELECTRICAL NOT BE SHARED WITH OTHER LOADS TO SI IG DELAYS AND OF SIGNAGE, ;ry o Gr DR �G AMI,DED CAUSING DELAYS ADDITIONAL COSTS AL B L o BE IL ED o PNC HED •ISOLATE ALL ALUMINUM FROM SIEfI • 11 FEDERAL Rf�L>yIppnS r APR 15 2019 a JA•Eu 3P_Jfks iiiIr -1A UF61AIAMA°Iani 1,d"Mel Al .An G1002x:9VAilA Re se 9491,7 Boyd yy.''�, Oc A . Euless.TX sATlSonvtlk.IX A601.78.191LU d 1 —...—_ A:io unl Re(, H 1ppenStiel /� f P �1. - 1t.i 11211.19.IAInIlOAU Ir lemni I ' ° " 23-50182-10 GOMV Ay ENT HEATH R lO off•R cnc �° w p Dob Number Alaina Luciano e «,1 LF Martat cr and 1S nGl to b.=exhibrtecl. UK�L ra R3 I2-OdIBVAl10AUpdmeElnaiom°nd°dMSion N,Iend Nev5gR1 A701JII91GRenre wryly noir I 3 October 9 2018 Ocr V CA L Vey.,NJ L' gF l .fz lax "F.AI,10 E TX .1.1.1 -dt TX- Ao nu.TX 5401 i1.:9 DADS UOd fl 9nR9 ed S- NMI y 1 Dramrl Hy: Jesthan DelCano/JDR 0 L"�` T VV Uh 7 or fe written(Sips I p7?70C1 VAi(NC5 S-BI IhLIFI�v.O VISUAL COMMUNICATIONS Ha.a 7X Lows CTI,,, TX !aurfmil 1W vr;tno.JF me tnirl[Terl W rvAr,,,fV F II TN C h U7 0°Aviare(Ni --9 '0,,I7 77-" r,in=.V , r.�;vtay f o[49,[ch ACIU•l�Orn thea h.1it i; Re�r T0?J(lt ' _ ELECTRICAL TO USE UL LISTED Store; #T1947 Underwriters Sheet.Number: (- 111 i 4 S 0 I1 0 I www.EeaeralHea[h.com V!h b ok lbw.,MS Atl GA Laboratorieslnc. COMPONENTS ANOSWLL_MEETramiiA 4602 North Avenue Oceanside,CA 92056 -'r. n.,�„r,n0e.r,r ,,,..,., i elientApproval/Date, A4 M L C ,TAaoAto, 2201 SEA TAC MALL BLVD Federal Fie,,En Sign AIL EC 00At„r;1, ARE., COMPLY R .,INCLUDING, FEDERAL WAY WA 98003 - 9 company. LLn of Its (760)941-0715 Fax(7601 941-0719 Building Quality Signage Since 1901 Landlord Approval/Date: TME'PRO ER GROOUNDINLEA40 lIO IJ NG OFAllSGNSsi n Number 23-50182-10-R8 auCtlOn2eCi agent CT.FHSC 1 gd ° DRAWINGS ARE FOR DESIGN INTENT ONLY... Sign to mount to metal fins. I N()1N—SP1ANI)A111) i Survey/detail needed for MATERIAL FINISH COLORS ENGINEERING REQUIRED TO DETERMINE ACTUAL MFG.REQUIREMENTS �•� _ ..w...�_ Ht"L 7326 White r--- engineering V Sloan While I ATUGLAS While LED Acrylic - Return, Faces Trimcap/Relainer Illumination C I I SPACE MAXIMUM 1" N A D —_ — MINIMUM 1/2" -77 31/2° SPACE MAXIMUM 1" 3 1/2" 1 WALL /, E — E F E — E - MINIMUM 1/2h . . . • — — 080 ALUMINUM FILLER \' :(7. 0 INTERIOR PAINTED:WHITE O • '\ • .ALUMINUM RETAINER EXISTINGl. y ELECTRICAL Is' r TRIM CAP OR RETAINER �.T PANEL a:,.2 '4i�! _ � (See Matrix) A B (Th MINIMUM.090 ALUMINUM BACK ... , ri-d r . 0 PIGMENTED ACRYLIC FACES -� 1 aire \.., SLOAN LEO `u 11.1 — I,"ELECTRICAL BEYOND SIGN LOCK-ABLE DISCONNECTIS '-a• _......._-_.. a.,_.-......,...,.»,.,..............,..__....»_..-.___.--_--._.. .-'-__-__ -. J Al BY INSTALLER SWITCH BY OWNER-WIRED w.._....._'-.. % ^ _J INSTALLER TO PROPERLY SEAL WALL • BY ELECTRICIAN "—� END VIEW SEALER:BASF-MasterSeal NP 150 N • >' LY.\7 (I PER CIRCUIT) D D. -J-BOX BY INSTALLER ---- - ---- - -� ACRYLIC FACED INT. ILLUM. "LOGO & LETTER" SET I LC-3W ALL MOUNTING HARDWARE(INCLUDING SPACERS) - A., i �.7 TO BE SUPPLIED 8Y:INSTALLER MINIMUM 3/5"STAINLESS STEEL MOUNTING HARDWARE 4 V,4 '` POWER DISTRIBUTION BOARD ISA �..1 BY:FEDERAL HEATH SCOPE OF WORK: _L) �� �� � _ ..___ 0 4 WER MANUFACTURE AND INSTALL CHANNEL LOGO & LETTERS 3 #.II 'a 12SUPPLY.SSUPPIV CLASS TWO EDBY; D MOUNTED BY:SUB-CONTRACTORi FEDERAL HEATH I _' I LoaD LETTERS AMPS 4' SIGN TYPE A B C D E SQ.FT. QTY. CLASS 2 SECONDARIES TO DISTRIBUTION BOARD ,RETAINER iii:RET CIRCUITS TO BE RUN THROUGH CONDUIT SUPPLIED BY - - .- --. _ - 6.��4n6u11111111NIN1111111111111111111111V ,III1NIIIIIIIIIIIIIIINN 111 NNIII IHfI. INSTALLER AND WIRED BY INSTALLER LL60/40 LC-3 W 5-0" 3'-4" 18'9-1/4"• 12'11-1/2; 10" 1'-8" 1" 1"T/C 93.9 1 DISTRIBUTION BOARD AND POWER SUPPLIES SUPPLIED BY FEDERAL HEATH SIGN CO. LOGO/LETTER WALL DETAIL NOT TO SCALE 3.5"DEEP CHANNEL I INTERIOR APPLICATION I NO WEEP HOLES (Generic) CUSTOMER TO PROVIDE NEW&REMODEL CONSTRUCTION DEDICATED BRANCH CIRCUITS FOR ADEQUATE BEHIND THE WALL BACKING AND SIGNS ONLY PER NEC CODE 600.5 ACCESS IS REQUIRED FOR THE INSTALLATION ALL BRANCH CIRCUITS SHALL BE DEDICATED TO OF NEW SIGNAGE CUSTOMER TO FORWARD SIGNS(INCLUDING GROUND AND NEUTRAL)AND APPROVED SIGNAGE DRAWINGS TO THE ON SHALL NOT BE SHARED WITH OTHER LOADS SITE CONTACT TD INSURE THAT THE REQUIRED INSTALLATION OF THIS SIGN SHALL CONFORM ELECTRICAL REQUIREMENTS PROPERLY SIZED GROUND WIRE THAT CAN BE PROVISIONS ARE MADE DURING CONSTRUCTION, TO ARTICLE 600 OP THE NEC.UL 48 AND OR TRACED BACK TO BREAKER PANEL IS REQUIRED PRIOR TO THE SIGN INSTALLATION OTHER APPLICABLE LOCAL CODES,INCLUDING Total 0.0 Amps INSTALLER REQUIREMENTS INSTALLER REQUIREMENTS FOR EIFS WALLS THE PROPER GROUNDING AND BONDING OF THE SIGN. ALL MOUNTING HARDWARE, SECONDARY IT IS THE RESPONSIBILITY OF THE INSTALLATION TE: ACCESS OK THE LOCATION OF THE DISCONNECT SWITCH,AFTER INSTALLATION WIRING AND CONDUITS ARE TO BE PROVIDED CONTRACTOR TO PROVIDE ANY WALL SPACERS BY THE INSTALLATION CONTRACTOR REQUIRED TO KEEPEIFS WALL MATERIAL FROM SHALL COMPLY WITH ARTICLE 600.6(A)OF THE NEC. (1 ) 120V 20A Circuit Required. ALL PENETRATIONS IN THE WALL ARE TO BE BEING COMPACTED DURING INSTALLATION OF • ' �_. __-.. _.._..._-_1 SEALED WITH SILICONE AND TO BE WATERTIGHT ANY MOUNTING BOLTS REQUIRED FOR SIGNAGE ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING ANY DEVIATION FROM FEDERAL HEATH {,,.,`�cc��NE�I _ _r� GROUND AND NEUTRAL)AND SHALL REQUIREMENTS MAY RESULT IN DAMAGE iST a1.uW7kltY C MBOOI_DiI�NI V NOT BE SHARED WITH OTHER LOADS. TO OR IMPROPER OPERATION OF SIGNAGE, :ALL BOLTNHOLESA NUMBER OFFASTENERS OR PUNCHED' CAUSING DELAYS AND ADDITIONAL COSTS • it/�y�� UMIN' J u{y� tall S tattl sDtaMf AA RCA77171 RS 01.2219 YANK Renew Sigel Nom peddle - -r �/ V Manufacturing Famines Al llfi-II1P IhdelN elewOan adaYrd lei dloC Boyd Hippenstiel �_it.;rit,ri J� � ��w�m �E DE�� "g AE 0141a91GN den rib Account V.cl. Boyd ..'M :, � Y'T r 4 Dela Eu..,Tx ie sui de 9 eel wire, 23-50182-10 �U17Q1/I Delaware, -Racine WI A7ILI9.IARWIDR Upddetreom Anel Ogle Job Number planned project H EAT H Pr �I � , Alamo Luciano0 - Office Locations 8012.06-IRVA/100.Updh Fkwlwns and added SO n.Io�Ne.5ipn1 A711Jt-19 Nr Beware wnrF DPW x '�• and i<_not to he exhibited, Oceennde,CA :,.Wgrt NV Laughlin AZ Date October 9,2018 copied or reproduced oer,u Fab.ID-Euless Tx•Jacks-o Tse Tx San Antonin DI RE 11-IbI910ISLE Update,Iwen7 R le .00d ISR. IRO Ai 010619 MICHCR d t.R io le1.-Iliad Drawn Ljs.. Jesthan Delco no/JDR _ VISUAL COMMUNICATIONS House ,x corpus Ch.sl.Tx Indianapolis,IN A without the wnuen lou,iville,NV-F le TN Grafton WI•DeYwah OH Cilh)sa Del..�P�Ire Cul,k :-:-�4'0,V tic 1',,,,i r u�=i F n.;hetl M:isentls nC1C TO Product J..in,>!fs ru`ta,fr,Co,,!rV1cT(Ctl 9 ELECfgI[As i0 USE U L IJSTE° Store: #T1947 $ { Underwriters Sheet Number: p e r rn I s s ; n n o www.Federa!Heath.com ® nec coa,roge AA°swLMEe r r;,,rbc tiaho�n..an,MFr"�u�LGrL Client Approval/Date: Lab°r"wrKR Inc. ' „L, N E C STANDARDS 2201 SEA TAC MALL BLVD Federal Heath Sign 4602 North Avenue Oceanside,CA 92056 A....ec ta.C...r.o...NOV,0 Correa r,n.,... 44,4010 Company, LLC or iI s (760)941-0715 Fax(7601 941-0719 Building Quality Signage Since 1901 Landlord Approval/Date: r„,'::IC 600 Or CNC„o'ACuu I AAwu°rrra S. INC,t a`.; FEDERAL WAY,WA 98003 Design Number 23-50182-10-R8 APP authorized agent coFHSC 2'-2" / TYPICAL ELECTRICAL COMPONENTS SHOWN. SUPPLIED BY INSTALLER-TO BE UL LISTED AND APPROVED PER NEC 2005 NEC 600-4,600-3, •O 2'_0" FBS 4505-4& DESIGNED TO U.L.48 PER F-S.553-19. BUSHING PROVIDED BY SIGN INSTALLER. CLASS 2 12VDC 120/240 SECONDARY WIRES • �' I .125 ALUMINUM PAN POWER DISTRIBUTION BOARD Stiell \ ,..4(.7-d.,0,00/.. ---11:1r./.1 (PDB)WITH 3/8" DIA. HOLES FOR MOUNTING t �` • BY FEDERAL HEATH SIGN. •'‘., �\ �� 0 SLOAN POWER SUPPLIES BY FEDERAL HEATH SIGN. \ 1' s%, INSTALLED TO BOARD BY SIGN INSTALLER. '` �, ` 4,e< ELECTRICAL(2'-0" ) WHIP TWHN #12 WITH TYPICAL rr• = ELECTRICAL COMPONENTS SHOWN, SUPPLIED BY ��� I ." �� SII I' IlINSTALLER-TO BE UL LISTED AND APPROVED , �N' 1 I I:.• ) PER NEC 2005 NEC 600-4, 600-3, I=BS 4505-4& ♦ E- N • VI .Q . .i ` • DESIGNED TO U.L. 48 PER F.S. 553-19. \\ % \,\ .% 11111I1I. .II ilI ISL' .. 1=1", gal .. 1 'Ilr ISOMETERIC VIEW (Power Distribution Board)(Generic) _-_.� - . __ NOTE: • / • T , POWER SUPPLY QUANTITY DEPENDENT ON SIGNAGE REQUIRED. A INSTALLATION REQUIREMENT: • • 1 120 V ON/OFF DISCONNECT,CONDUIT power distribution board(pdb)to be mounted no more then 12"above AND PRIMARY TO PDB CONDUIT ceiling to the bottom of the pdb. refer to design drawings for specific PLAN VIEW (Power Distribution Board) (Typical) location of pdb.pdb to be mounted so that it is easily accessible from AND PROVIDED BY G.C. ELECTRICIAN. a step ladder. scale 1 1/2"=1'-0" SCOPE OF WORK: SLOAN POWER SUPPLIES BY FEDERAL HEATH SIGN FEDERAL HEATH SIGN TO MANUFACTURE A"POWER DISTRIBUTION BOARD"-(PDB). INSTALLED TO BOARD BY SIGN INSTALLER TO BE.125 ALUMINUM BREAK FORMED PANEL'h"DEEP PDB TO HAVE 3/8"MOUNTING HOLES PRE-DRILLED. ELECTRICAL WIREWAY .125 ALUMINUM PAN POWER DISTRIBUTION INSTALLER TO MOUNT LETTERS TO EXTERIOR WALL AND RUN SECONDARY LEADS IN CONDUIT THROUGH WALL INTO A HANDI-BOX. BOARD BY FEDERAL HEATH SIGN CONDUIT THROUGH WALL TO BE SEALED FROM WEATHER WITH APPROPRIATE SEALANT SUPPLIED BY INSTALLER. INSTALLER TO WIRE ALL SECONDARY JUMPS TO CORRESPONDING LETTERS INSIDE BUILDING. 1._V__�T ,r I. INSTALLER TO WIRE SECONDARY LEADS TO POWER DISTRIBUTION BOARD THROUGH CONDUIT. v 70150%WP =�` - j INSTALLER TO COORDINATE LOCATION OF POWER DISTRIBUTION BOARD WITH TARGET ON SITE REPRESENTATIVE PER (E-8 SITE ELECTRICAL DRAWINGS). 1/2" SIJ `--- t. INSTALLER TO MOUNT PDB WHERE REQUIRED. PDB MAXIMUM DISTANCE FROM SIGNAGE IN ANY ONE DIRECTION IS 150 FEET. END VIEW PDB TO BE MOUNTED USING ADEQUATE HARDWARE SUPPLIED BY INSTALLER. scale 1 1/2" = 1'-011 ELECTRICIAN IS TO SUPPLY AND RUN PRIMARY CONDUIT AND DISCONNECT SWITCH TO PDB AND MAKE FINAL CONNECTION SHIPPING NOTE: ALL WORK TO BE DONE PER NEC,UL 46 AND LOCAL CODES. PLEASE SHIP ALUMINUM PANELS WIIH POWER SUPPLIES IN THE SAME CONTAINER. RESUBMITTED APR 15 2019 �E DE�� kel•rSlon' 4501-27-197A,1N Realm 50 lltcm cukoAc numaur a r .eoaard.l:. c Pro rt location Boyd Hippenstiel 1�VAY Mn,xRatturing Fa0liUcs �b _ - -.d_.. _.___._- — _.... — ^Ci..... 1e_ / '11 F� Oceanside G Euless Tx facMorrvAk,D: 46012819 iG Updole p.r,umr'r10 23-50182-10 � 10LO ME 1 erna9.lelsoY4upa - Job Number n n e LJ G o J e C[ HEATH DelawareoH-Raoneun ProectMana er Alalna Luciano0 _ orcertGatxK IDtt.•urum4upam9rm.,and dddsoxl.du sy.l R9n1+119,rRLmL.e„ncob J 9' Ilsnottohc xilio,ted, . ocean/de.to taf Vegas NV teugnlin October 9 2018 1aalsn Fags ID E” TX fadorwae Tx sat Antonio TX R401.161910I10R Updole,ion's/Hinge d 5, MI B,, Jesthan Delcano/JDR nate ' Iled °` reproduced 4imge«oW,e Dos ( R1BJL! [9xued$gAYbNMjwh9 Drawn VISUAL COMMUNICATIONS Houston Tx•Comas(Wan IX InOmnapoloIN bout the wntten Lwnsvdle,Nr KrrmAe TN Galren WI Drksa,.OH Co'or,Uepreree Ir Dos RLndcring May Not Mat DI Actual r n Shen Mat.:r r..re,To I'oduct Sarni/PS For Exact COO!Mel,I: 4 EIECTRKu io U5E u, usice Store: #T1947 www.FederalHeath.com ®Undewrites Shoe:Number: 9 e r m s s l o n o r Willowbrook M. Tunica.MS-Amax GA Laberawrters I nC. ofc - �NENiSMID SHNL MEET Tampa rt Daytona Beach.11 00andn n Client Approval/Date: ALL N E SAANDABD. 2201 SEA TAC MALL BLVD -- Federal Hearn, sign 4602 North Avenue Oceanside,CA 92056 CCGNS A.E To CGIYrL.WITH?,',:11',1^''''' FEDERAL WAY,WA 98003 Company. LLC or its (760)941-0715 Fax 17601941-0719 Building Quality Signage Since 1901 Landlord Approval/Date: '''''''T4`` '''''' ''''';'PrGrEo GaGUNG NGEANG tsONeINpG or ,r .GNs ,,sign Number er 23 50182 10 RS authorized agent CIF SC