Loading...
18-101936 ' r , . • Electrical „otyDeve Permit #:18-101936-00-EL 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax.(253)835-2609 Project Name: L L MANAGEMENT LLC Project Address: 3098 S 337TH ST Parcel Number:442060 0035 Project Description: ADDING 400 AMP SERVICE TO GARAGE Owner Applicant Contractor LL MANAGEMENT LLC LL MANAGEMENT LLC OWNER IS CONTRACTOR 24913 104TH AVE SE 24913 104TH AVE SE KENT WA 98030 KENT WA 98030 5 , Additional Permit Information Is this an Online or O.T.C.application Yes wl Alt.Serv./Feeder:201 to 600 a 1 / gliCO PERMIT EXPIRE Saturday, ay,20 Permit Iss • • i Fri i . 4 01 • I hereby certify that the above info r- o ' co , 4 =t the con ion on the above described property and the occupancy and the u wi •_ ' -- • an •th the la les and regulations of the State of ashi - • t• City of Federa ay. Owner or agent: �/ • • Date: S 'h ..'o �111ill, 0 ,,i.g. a ,r, <(.00,-., k•Ni' (V . 3 018 S, 337lb SI, ao - y3a - Christina Dunlap FILE Aios. From: Law Office <lawofficenow@gmail.com> Sent: Tuesday, May 01, 2018 11:55 AM To: Permit Center Subject: Fwd:Construction Details for 3098 S 337TH ST, FEDERAL WAY,WA 98001 Begin forwarded message: From: "Russu,Sergey"<Sergey.Russu@pse.com> Date:April 26, 2018 at 10:45:33 AM PDT To:"lawofficenow@gmail.com"<lawofficenow@gmail.com> Cc:"Russu,Sergey"<Sergey.Russu@pse.com> Subject:Construction Details for 3098 S 337TH ST, FEDERAL WAY,WA 98001 Hi Irinaa, In the previous email,I gave you your new construction date, May 8,2018.All work must be 100%complete by May, 1th,as I will be out on site to inspect and make sure that the site is ready for our crew to go out and do the appropriate work. With that in mind,I outlined the very things that I will be inspecting.Please be sure to complete it prior to me coming out and inspecting. • At the Pole—P01: o Make sure to have a 4'x 4'work pit at the pole o Make sure to have 1 yard of 5/8"crushed rock at the pole • Primary Conduit: [P01—V01] o Install 2"—Schedule 40 Conduit&minimum 36"bend radius o Trench deep enough to have minimum 36"of cover from the top of the conduit to the final grade (suggested to trench at least 42"). o Make sure to have 1ft of separation between all utilities. o Have the conduits be discontinuous by stopping two feet short of the pole and the vault. o Make sure to have pull rope from P01 to V01. o Cap the ends to not allow rocks and soil to enter the conduit. • Transformer—V01: o Make sure to have a 7'x 7'work pit o Make sure to have 6"of crushed rock at base of the work pit(36"vault up&6"of crushed rock). • Secondary Conduit:[V01—MO1&M021 o Trench deep enough to have minimum 24"of cover from the top of the conduit to the final grade. o Install 3"—Schedule 40 Conduit&minimum 24"bend radius o Make sure to have 1ft of separation between all utilities. o Have the conduits be discontinuous by stopping two feet from the vault and the meter-base. o Make sure to have pull rope from V01 to MO1&V01 to M02. o Cap the ends to not allow rocks and soil to enter the conduit. • Meter-Base: o Make sure the meter is in the front thirds of the house(relative to the driveway). o Make sure the meter is set at 5ft in height. o Build the Meter-base and have it L&I inspected. 1 I . 4 4-04 THIS CARD IS TO REMAIN ON-SITE FecJeral Way Construction Inspection Record INSPECTION REQUESTS:(253)835-3050 PERMIT#: 18 101936 00 Address: 3098 S 337TH ST' Project: LL MANAGEMENT LLC FEDERAL WAY WA 98001 Scheduled inspections may be failed if this cant is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 UFER Ground(4295) 0 Ditch cover(4030) 0 Slab/Concrete Floor(4255) Approved Approved Approved to place concrete By Date By Date By Date El Pool Bonding(4195) 0 Temporary Power(4275) © Service(4235) Approved Approved Approved 'By Date By Date Date _;1 p— 0 Feeders/Sub-panels(4045) ® Rough Electrical(4225) 0 Ceiling Cover(4020) Approved Approved Approved By Date By Date By Date El Final-Electrical(4055) Approved By Date • 0 Rough Electrical 0 Final Electrical 0 _ Right of Way Approved Approved Approved By Date By Date . By - . • Date CITYOFA RECEIVED ELECTRICAL Federal Way MAY o 2018 PERMIT APPLICATION CITY OF FEDERAL WAY PERMITNUMBER 18r 1 0 ( 9 3, 00 COMMUNITY DEVELOPMENT - - SUITE/UNIT/SPACE# SITE ADDRESS: 30 9� S 33 -41`� S PROJECT VALUATION f/-(1r ON ASSESS TAR/PARC.# � � - 'Q O �� PROJECT NAME CURRENT/PROPOSED USE 2 O (Tenant or Homeowner Last Name) IL_ N"tiiNA C fplAe " (-A L, PROJECT DESCRIPTION 6/00a""P 'fes,i'^oz, Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER LL (I'latel c`4".eAr..--e-r-v\---- (ZC) ,) ?a - 5151 MAILING ADDRESS E-MAIL Z4° (a- ¶ c CITY STATE ZIP FAX ke..e.,./.Nr vv.) - f9,90-3 ( ) - NAME PRIMARY PHONE MAILING ADDRESS E-MAIL ELECTRICAL CONTRACTOR CITY STATE ZIP FAX ( ) WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# / / NAME PRIMARY PHONE APPLICANT oww� ( ) MAILING ADDRESS E-MAIL CITY STATE ZIP FAX ( ) NAME PRIMARY PHONE PROJECT CONTACT 0L,kAry 6.7 ( ) - I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to arty claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of ch claim), which may be made by any person,including the undersigned, and filed against the city, but only where such claim • les out of the reliance of the city, including its officers and employees, upon the accuracy of the information suppliedto the as a part of this application. it / SIGNATURE: / i. DATE 1 PRINT NAME: 14---''0% Bulletin#160—April 14,2016 Page 1 of 1 k:\I-Iandouts\Electrical Permit Application ) , , 41/46, CITY OF Building Division ' 33325 Eighth Avenue South ,,, ,,,, Fed a ra I l! 1ay Phone 253 835-2607 Fax 253-835-6325 CORRECTION NOTICE ADDRESS: 0g S - •'•--/ S-.(-- PERMIT#: n - ton G, -,(::0 - EL V)C t--0,Ar_lA. \A r .e-9 v ,\- CD 1.2 ch-- I c�J a ,.-c_ o I - v-L-- c� w1 �wcvV� S • 1 Z . ) t —L \ \O . V2. 110. -3 (ham) C _ \- i's--e J -. \00O 1 \s-,(--- 1 i S L t'Nt Y'-e 9 v,)-LlnA 4_,✓14 • • K 1- C _ 300 • S am ) A wav-i..‘\n 1(---i ,b... -,c/✓\ S\c...\ \ . - \ VI S L.,.\ \-f? GOJU 1/--C -S-P V-L/ e_ 1,, (.,c_ei , S 1\--\ ±v--e,fri C.,(/‘ py- ,(11,---- "kte--, et c---V -ci \\. - A-) E S-0 •q 44kTIAATheS----.214-1 Vic),\--JO-e.►�4,.�,i IA e c.11_ ,,,,/(,-(-- -51,,,, (1 b-.e r0/ 5.) 1 L 7.s-lo •ci 7,, .�8s�P`0\ siD, , -t,:r `t ,,... - v,,,Th,\,:c ______ J U 1,-,(�( s--,,_ A.,-) 6,11v� C�'. /J�'Le lr" so c_12.0 4 �i✓i c.l c.0 t"r-e 43.-- G.T '�I�R T. rf)i tir 1J )c-ewtrD v C 4-v-- A----P v-- .. vl h .4----,..e.$--- kA.), i\^ .ii..--c+maS-P r tv,'<J2 -� c'.(ci S ci v--C_ - 1 cl ,� es— 7._, D • 7 ` ti,i(--(_c)I'S Gu 1�t�nPC I.,c� b �✓c�C�7) t & \ vj , \.02)) (.cn,�e5I�\V 1^ v,(_ (Serve"�.-e IF YOU HAVE QUESTIONS CALL __._ D S—Q 1 < Z,z_V----- (253) 835— Co2 fi WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE-INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. S l'- tom DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of 3nze41 SITE SPECIFIC NOTES POWER GENERAL NOTES RESIDENTIAL PROJECT / MINA 1• 0 CIRCUIT FEET ADDED'320' REV1S10N 1: 1. All materials to be installed in accordance with Puget Sound Energy's(PSE)standards.Any deviation From this work sketch -NOTE:NEW POLE HAS ALREADY BEEN INSTALLED. must be AUTHORIZED by PSE's Project Manager and NOTED on the Foramens'Copy. (HOUSE) (GARAGE) .GSR SO.FOOTAGE:1,800 SO FT SO.FOOTAGE.900 SO FT s 2. All switching arangements and/or outage arrangements are to be made with the Project Manager at least three(3)working PANEL SIZE'320A PANEL SIZE:400A 0 911270.163837 POI:311254163821 (3-10) HEAT TYPE, ELECTRIC HEAT TYPE: ELECTRIC days in advance. EST.DEMAND EST.L SIZED: 'f'f -REPLACE L7C75TlNG BIO POLE W/50'CL-1 POLE(P0501)W/GROUNDS PER STD 6010.1000 (2-729-3 I LRC:85A LRC:805 UNK �"• ae -NOTE:INSTALL POLE NORTHEAST OF THE EXISTING JPOLE WITHOUT CHANGING THE 3. Contact the Utilities Underground Location Center(1-600-4245555)at least 48 hours prior to commencing work to gat the X V.DROP:2.0% x V.DROP:4.3% TRAJECTORY OF THE EXISTING OH TREE WIRE underground facilities located. / %FLICKER 0.9% %FLICKER:1.1% „ -INSTALL(2)9'13P DOUBLE STD ARM 0 I' 2• " -INSTALL 12kV 30 DEADEND(DE3310)PER STD 6033.1042 4. STAKING:The customer will provide all staking(transformer,handhole.trench,grade,lot,pole,sidewalk,etc.).See sketch / n -ITRANSFERNSTALLPRI 336.4 TREE WIRE(NE) and details for locations.Equipment locations must be approved by the Project Manager. ''" 1 50' I00' - -15ltV CS PIN 0/H TO UAS 10 TERM(TSU7C7)PER STD 6043.1000 / 5. SITE PREPARATION:The work area will be at or near finished grade,clear of trench spoils or construction materials which -INSTALL 1-LIB G13 ON NEW FG ARM,FUSED 407(3412400),TAP'B'PHASE would restrict construction and/or equipment access,before work can begin. 3118 17 -INSTALL SWITCH#779250 PARCEL# -INSTALL 1•LIB C/O ON WOOD ARM,FUSE 707(34122(X1),TAP E'PHASE(FOR TRANSFORMER) 6. Roads shall be paved or have a compacted,crushed rock base in place. 4420000035 3104 1 ` -TRANSFER EXISTING 25kVA TER (¢ -INSTALL(1)2'PRIMARY RISER ON NEW STANDOFF BRACKETS(RIS2CSS)PER STD 6042.1000 7. CLEARANCES:Transformers require a minimum of 6 feel from Ere fighting equipment,10 feet from combustible walls, -INSTALL(2)3/8 SPAN GUY(GYD30W)PER STD 6013.0170 overhangs,doors,and windows,and minimum of 5 feet from the back of curb(or guard posts will be required per PSE / ", 0) 1. standards).All,conduits and vaults are to be at least 5 feet away from water,storm and sewer lines when paralleling them In „ -INSTALL 4'RfG/0 CLEVIS(INDNRC)!N COMMON PoSITION(t7 the right of way,and at least 1 foot when crossing them. 3 -TRANSFER EXISTING OH SEC WIRES -COMMUNICATION TO TRANSFER 8. All work is to be done in accordance with local municipal and county permit requirements as applicable. 31126.163830 Q}7 -WSTALL GRID 113}1254-163821 4,1kihh...,,, Imo) e O 9� 9. Inclement weather conditions may cause delays in construction times and dates. / dj mel I_I 9108 4' V01:311263-163797 (3-141 10. EXCAVATION:The customer Is to provide all henching,backfill,vault excavations,compaction and restoration per this ® =s- V01 311263 / 11254.183821 e.° -INSTALL 48"X 48'MP NON-UNISTRUT HH 8 GRNDS(MINII5L)PER STD 60451000 sketch and per PSE standards.A minimum protective cover of 36"is required over PSE's primary voltage equipment and 163797 VA 1202410% -M"' -INSTALL 100KVA 10 120240V TRF(MID:6247200) 24"is required of PSE's secondary voltage equipment.The customer will provide any and all shoring or they will side slope 100kVA 120/240v/ e 407 the trench to 1:1. . _ -0__ -INSTALL(1)LIB ELBOW 7 3 PER STD 6041.1000 I -INSTALL(1)DUST CAP(MID:7630600) L -INSTALL(3)8-POS#6-350 KCMIL SECONDARY CONNECTOR BLOCKS(MID:4842102) 5 337TH ST 0i -INSTALL GRID#311263-163797 w .a_ M01:NEW HOUSE METER BASE (3-91 cr - _ -PSE METER DEPARTMENT TO SET CL320 METER • M02:NEW GARAGE METER BASE 13"81 \., ` 311249-163815 -PSE METER DEPARTMENT TO SET CL400 METER 8 APPROPRIATE CIRCUITRY CIRCUIT LOADING TABLE `___,EyERHAEUSER WAYS _ SPAN SPECIFIC NOTES AS OFA 08.RB117 A PHASE 8 PHASE C PHASE `� P01 TO VOL: o ----„„___:� --- ,,, EXIST.PEAK LOAD 351.00 308.00 319.00 \\\ -CUSTOMER TO INSTALL 1-2'SCHED'L 40 DISCONTINUOUS PVC CONDUIT 1320' -� _` ```` -INSTALL 1-RUN 110 UG JKT CABLES 370'(BBEH1597) EST.NEW LOAD 0.00 8 04 0.00 \ ` ( 311241-163831 TOTAL 351.00 308.04 319.00 \�,,. •657 Po1 TO M03: (3J1 c,31 -� I .�X2705 -TRANSFER IXISTING OH SVC,SERVING"3106•TO NEW POLE E II I I W1 TO MO1 8 M02: (3-61 6(3-6f SITE PLAN / I -INSTALL 2-RUN 350 UG TPX 3160' o SCALE:1"=50' / V I F.,2. 0 CUSTOMER SUPPLIED FOREMAN(CHECK BOX WHEN COMPLETED) Vicinity Map 8▪ PRIMARY CABLE&CONDUIT TABLE 4'X4'WORK PIT 0 PSE Equipment LOCKED/SECURED a ANN Arm len In CLEAWSAFE Cm6am N/A LOCATION CONDUIT CABLE ASBUILT INFORMATION-FOREMAN COMPLETE ❑Gdd.Cable aria S..numbers INSTALLED&VERIFIED I - ❑FieldChanges RED-LINEDendcII L on • ` D Material VERIFIED aro CHANGES noted m w«F. • I Pece .' .DESIGN BENDS PULL DESIGN PHASE-ID TAG RECORD RECORD PHASE TAPPED&ACTUAL FOOTAGE INSTALLED CUSTOMER SUPPLIED ❑rota P IR MARY Cable^aid on ud41. / ;p. SIZE PULL CABLE ❑Company lois RECORDED in awed I«atNn m Aaavt SiROM TO QTY. LENGTH REV LENGTH - - 2-3'SCHEDY 40 PVC CONDUIT 3 140' " o, (UNI (LBS) SIZE I��. ❑Inde es miaa FUSE 00«,As-boatavEre0 proper PHASE. I n (n) 90• 45' 22' 11' (�5) TT) A B C MANUFACTURER COMPOUND YEAR NOTES CONDUIT CABLE ® T� INST.2-RUNS 350 UG TPXt 760'IED O D.4ri«a rdeemme wrouaw mew mason. I P01 VO1 2 1 320' 1 1 142 208 1/0AL JKT 370' EHI597 ® !'3/4CUSC CYARD SUPPSAND ❑ 55I SI me8n,requirements we PSEs standards am procedures w 2"PVC(FT)8 BENDS= 1 1 0 0 1/0 AL JKT TOTAL(FT)= 370' V01 CUSTOMER SUPPLIED act drat all qua8ly requimmenb xe met � 0 O 4'X4'WORK PIT 11" CO CUSTOMER SUPPLIED Foreman's sgr,aae O3 C90 ----= - INST.�RUNL1 0 UG JKT CABLE t 370'(B0EHI597) P1m Name Date t ( a^ .• O RETIREMENT POLE TABLE O) m SITE POLE DATA POLE TRANSFERS REMARKS 45' PROJECT PHASE NOTIF# ORDERS •"" • # GRID 0 HEIGHT CLASS YEAR XFMR CO.ID# TOPPED RMVD TEL TV FIBER ST.LIGHT (ADDITIONAL INFORMATION) Ty-�/ PWR Superior 504928785 151/05503 1 CUSTOMER SUPPLIED / 101109553 P01 311254-163821 40 UNK 1964Pole Construction ❑ ❑ ❑ ❑ ❑ ❑ T X T WORK PIT CUSTOMER SUPPLIED 108104231 ' 1 CUBIC YARD 518'CRUSHED ROCK OH Conswd on 5 9 3191412 \ N House Penn Svc 504951857 104295943 POLE TABLE (NEW) NEW CABLE&CONDUIT DIAGRAM Garage Perm Svc 505422205 104300230 Ai Site PON Data NOT TO SCALE GAS a grid at height Class Year Remark■ILocation Ref. CUSTOMER&DEVELOPER NOTES N P01 311254-163821 50 1 2018 PSE Equip# THE CUSTOMER IS RESPONSIBLE TO PROVIDE ALL TRENCHING,SELECT BACKFILL,COMPACTION 8 . ) / :C 257\ CABLE T -Owner/Developer Contact Info RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 L-. •- •� PHONE 10 aLL Z" -REQUIRED TO PROVIDE 8 INSTALL 1-2"SCHEDULE 40 PVC CONDUIT FROM P01-V01 t 320' 's J.ioTH�.T N ; •rs ti t7 Protacl Manapar Contact Inlplmetion: 2de13 104111 AVE LLC TRANSFORMER INSTALLATION -REQUIRED TO PROVIDE 6 INSTALL 1-3"SCHEDULE 40 PVC CONDUIT FROM V01-MOI 1140' NORTH s f �a Alm Manager SERGE'RUSSU KENT,WA 98030 F 40T / ATTN.NOS FOX °Noe m -REQUIRED TO PROVIDE 8 INSTALL 1-3"SCHEDULE 40 PVC CONDUIT FROM V01-M02 n 140' LAKE R� IY s"yr` B - • 'i0 Cell PMre: (253)208-9712 « Installed at Site VU I ^y A: -C•9 N, C E-Mad: SERGEV.RUSSU(SPSE.COM -REQUIRED TO PROVIDE 8 INSTALL 3/B"NON-POLY PULL ROPE IN ALL CONDUITS `B 4 3;c, o `:.X10415 Far contacts below dial 1-888-CALL PSE(22SSP3) a Grid Number 311263-163797 -REQUIRED TO PROVIDE 4'X 4'WORK PIT 8 1 CUBIC YARD 5/8"CRUSHED ROCK AT P01 F;- --s 3i•3a 1...\_,A0 F♦ T >, kVA Rating: 100kVA 40T ; \u� . X8467 Dave Vas PSE CALL 817 Two BUSSES!!DAYS BEFORE YOU Dp e -REQUIRED TO PROVIDE 7'X 7'WORK PIT AT VO1 r' .. 'I- -T ala rr LVa_s J E. Material 1D#: 6247200 /B A x1057 3r +' + h A 7007 locates Required" No No rias E CH T TO/EA RELHDUPON FOR ENACT PERMIT No EXISTINGF aunEs -REQUIRED TO PROVIDE 4'X 4'WORK PIT 8 3/4 CUBIC YARD OF SAND AT M01 8 MO23.0i •AC til \ d C B� B B 1''30 X5540 'Ow9es Requeed• No REAL ESTATE/EASEMENT PERMIT Foreman to redline the following IMormMIon -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL .��,'�\ 1ST "Flapping Required" No 0' 9 y,•5T 2664 - ••-y �/ tf T _ - REQUIRED FEDERAL WAY c -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS 6 TRENCH AT ALL TIMES X27"-A A '3a ••-•.-.... ro Company ID#' 65 5.534 ST • 257 A/ 3 N/A N/A WA PROJECT CONTACT PHONE NO DATE D Y -REQUIRED TO EXCAVATE 8 EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION AO 257 X9759. L Primary phase connected to: -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL 1007 :30 1007 2 N/A N/A N/A PROJECT MGR S.RUSSU (253)208-9712 09'06/17 -----_ • TB h�, ....� 1 N/A N/A WA ENOR-POWER S.RUSSU 2551208-9712 p9.g8l1] -POE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE I Sat N Tested Secondary Voltage JOB SIT• '! 04 ,+;30 Ig i • 1 7 REV# DATE BY DESCRIPTION ENGR-GAS -FEDERAL WAY INSPECTION 8 APPROVAL IS REQUIRED 5 BUSINESS DAYS PRIOR TO CONNECTION 0L ; : yI 9C 8 COUNTY Einer Seel Gas Vsk Ctr POWER WK CTR DRAWN BY E.ORTIZ (774)89}2405 1232018 -CUSTOMER RESPONSIBLE FOR ALL TREE TRIMMING AND BUSH CLEARING 11 • X9760 LC it 26K 545. KING WA WA CSPSKEIN CHECKED BY 'moi-SES-R1.1Z SLtitU' e -REQUIRED TO PROVIDE PHENOLIC LABELS FOR THE"HOUSE"A'GARAGE"METERS 'I 460 KV AR '1 1/4 SEC OP MAP PLAT MAP APPROVED By J" J.1'S'11/«-Y SN_Vie i TRANSFORMER TRANSFER %/� -- A.B'"'•-• hl X-6177 2 SIX-6022 ) NE 21-R2W/04 WA N/A FOREMAN aH I. E New pole at site: P01 ` ♦X8 5 +257 A 25Th `514 U-MAP NO(POWER) OHCKT MAP UGCKT MAP CIRCUIT NO FOREMANE2 Grid Number. 3112$4-169$21 3a • 2570;x%STX_�2 R2104E081 D2104E092 R2104E081 KCR-17 MAPPING • . kVA Rating: 25kVA- : 85T R b JOINT FACILITIES ARRANGEMENTS Foreman to redline the faIia tng information .• - t : to yn19 •Y---r-•, h ;i UTIDTIES WA N/A N/A WA %1]ID-p m Company IN: 30r( yy Ql S.340 PL B CONTACT I WA NIA WA WA ;:',"4 Prima ase connected t0' / FIrIRC PHONED WA NIA N/A WA a • r4 cl a k' Ire d INCIDENT MAOP Primary 8 ij pl ___a jR X280964, gp SK3140„ PUGET LL MANAGEMENT LLC Elect of Tested Secondary Voltage 1 SOUNDGas Order " OVERHEAD CIRCUIT MAP 2104E092 ENERGY PRI LINE EXT,NEW EDERAL TFR, 9900 320A SVC LE EO6AGE SCALE'.6"=1 MILE 3098 S 337TH ST,FEDERAL WAY,WA 98001 SCALE PAGE ASPLUNDH CONSTRUCTION CORP. AS NOTED 10F2 CURB OR EDGE OF PAVEMENT ©„ m ( AUGERED HOLE ® 'it�/� 3 1 Mw PLACE STRAW MULCH ON 5'MIN DISTURBED AREA �rli�rli -� - - ( - — - PLACE PEA GRAVEL II ��s i'' MI ---l 11 00 �N. IM N--f 3'MIN &ANN—.- POLE BAGS(MID 9995892) II /i'%►1 I 3 , FOR SEDIMENT TRAP till �-MIN '—ra - DOOR I J V �I/ ' TYP.PAD I / 111AV ���11® 0 BTRMER 1�td MW 3 //i _ FORMER \ _ . I t rill _ _ ,,,,..,„, Nets Schedule KT corms shall 1. I I - ACCESS I VW-4k-tis' 'I //-� lir IA, _ COOLING�� DOOR I �� �-1 116/(11 111 ,xw.. laim t' e"e lz e. q .� - - - - - - II 1111 r .ii ...in.a.aro 3'MIN CONCRETE PAD C• FLOW DIRECTION 8- FINS lI M1�/ I1 i..G4. Illjl 1111 ■---_-� ,� a `f1�''r��-n J DITCH OR SENSITIVE AREA LAY U"BOTTOM EAIGTAV TOP OF NAD 99 SOIL, j /till p • a.��e T REQUIRED S MIN ROAD OR SECURE WITH PEA GRAVEL BAGS(MID 9995692). s...-..-r 2 1104,---'0.1+4 1c ._�` ii ;Lc WORKSPACE PARKING AREA - e ::1:;i=.,; 61,10,, 11l1Fi1�1 0.1+17. AREA / \ //7; 1-,,4"11... lti 144111 Jl/// TECHNIQUES FOR EROSION AND SEDIMENT CONTROL _l3ees. - //....i✓1J(i,1, I4 r 1 CURB OR EDGE OF PAVEMENT - -- ---- (IQ"°A`R 1 sie r R'"' ALTER FENCE DETAIL 1'llr', MINIMUM CLEARANCES FOR PSE EQUIPMENT @ V01 TYPICAL AUGERED WORK SITE-0150.3200 @ Po1 Not to Scab 0150.3200 "141 v NOT TO SCALE TECHNIQUES FOR EROSION AND SEDIMENT CONTROL a 0 n TYPICAL POLE WITH RISER DETAIL @ P01 J NOT TO SCALE E a s 2 F Poe� �jvy/�Oti N ROADSIDE f-18"Min 2� vim//�\/�a� o Final Grade ,1 I.;%:\/, v Toe rvt lNe �, i� �''\' . Standoff Bracket Q�r1`, ::Criated,,,,r;.rt `, `- � UNDERGROUND \ 15"Min Length 4 m \ TOHISQUADRAtt�:,•/5"Min Conduit Clamp 35' "^ /r7 Backfill for Schedule 40 ConduitCove "a 4•Min (NO Rodes over 10"Diameter / CSpaceg ozo Max ASeparation or forei objects) ` onduit FIBIdIFace P 9n Qt rantcn W w err _.. -. __ .-___ _...-_ A i -- F i, RoaQu Face EYcw fI—er '1 C Service(Permanent Detail:Z ��-co 1 Qua�ralrt r c •,;:,. ,,- ..\';'' Climbing .P3 Not to Scale - T - .1 4. ' Top v. Plane 3 N Primary Power Cable Space MF in Customer Provided a,�R„ '-N. Schedule 40 Conduit Direction of Vehicular Traffic E attl Wil. ¢ a ^1a�e "���;�.- i" JOINT TRENCH DETAIL "a..�� TOP VIEW Y 111,t4 *r,..n �� arr.ara— Primary-Schedule 40(NTS) CUSTOMER-CONDUIT&RISER LOC.DETAIL �/� SCALE:NONE o ` T awn ai o�..JaIrtw �r a 4e" F ogg 1.SMI .23 ,//21" \ i aghbrWM, /� TCante.Yalawr .-401‘.e,,,,'_ y ..•11 21 y1.til /�� / R Bac ll for In Conduit-The backfill layer shall be soil that is free front construction debris, \ iil AuarP .. r�i glass.sharp rocks.frozen clods,and rocks larger than 8"in diameter. ' TOP VIEW �i�� � 3B' ......›.2....",.....„..., / 111/11". ^ ^: trraw..cie...a Excavated Dirt Pile ^ ewe ea some unn � T/ \ � 20"Min 24"Min ( ` r°n ' ���� I` 3_ T Final Grade To Excavated Dirt Pie y `� I REAL ESTATE/EASEMENT PERMIT F b /f \ ^^ ^^ �I • , ,�9C� '�4%T "%'I��I �` 115���y REQUIRED FEDERAL WAY Y � �,.� ••/,�/ ... ^^^...- ^^ 3 WA NIA N/A FUNCTION CONTACT PHONE NO DATE Strut- lTRlra^^ friC•'f ^^- /\T J 2 N/A N/A WA PROJECT MGR S.RUSSU (253)208-9712 09/08/17 ro 54"\\�54"" 6" . .0111.... ^^^^ Nr / •• 24"Min Backfill for Conduit 1 N/A N/A N/A (253)208-9712 09/06/17 ^ ^^�^ ENGR-POWER S.RUSSU \ CRUSHED ^^^^^ to Free of rocks REV, DATE BY DESCRIPTION fiNGR-GAS On \ /� RDCK 'M„ea„IMr 3E"Max a larger than 8" COUNTY Emer Sect Gas WOCtr POWER W1(CTR DRAWN BY E.ORTIZ (714)893-2405 1/23/2019 Y SIDE VIEW "��q ^,. ' Cover $e2 Min n j/� in diameter) KING N/A N/A CSPSKDN CHECKED BY el c".rom.�waee ^ ^ Para 1/4 SEC OP MAP PLAT MAP APPROVED BY %��, 215-1/6-Y4fr� 1415 { EXCAVATION.61/3 CUBIC YARDS ^ - �^"` ' r5waaraoq we yy' NE 21it21116/ N/A WA FOREMAN 41 E 3'Sa ..o Or Wi L_ U-MAP NO(POWER) OHCKT MAP UGCKT MAP CIRCUIT NO FOREMAN62 Kuem�.nowea - 3V MINIMUM COVER a VAULT&EXCAVATION DETAIL @ VolVO1 RzlwEosl D21aEo92 Rn04Eoe1 KCR-17 MAPPING a p� e 1 IN RIGHT OF WAY N NOT TO SCALE STD 6775.0030 METER DETAIL(01 MO'I W k�\�� 1 JOINT FACILITIES ARRANGEMENTS SCALE:NONE �' UTILITIES NIA N/A WA N/A TV 8 TEL Electric Service Cable in Conduit CONTACT NIA N/A WA N/A m 3"Schedule 40 Grey PVC PHONES N/A N/A WA N/A 0 INCIDENT MAOP ® JOINT TRENCH DETAIL p LL MANAGEMENT LLC Ge.order Elect Electric Service Cable in Conduct(NTS) ENERGY PRI LINE EXT,NEW 100kVA TFR,&320A SVC 14/6 106096406 3088 S 337TH ST,FEDERAL WAY,WA 98001 SCALE PAGE m ASPLUNDH CONSTRUCTION CORP. AS NOTED 2 OF 2