03-102316 City of Federal Way Electrical Permit #:03 - 102316 - 00 - EL
Community Development Services
33530 1st Way S
Federal Way,WA 98003-6210
Ph:253 661 4000 Fax 253.661.4129 Inspection request line: 253.835.3050
Project Name: MENARD/AHNERT
Project Address: 32109 33RD StAt AVC 5W' Parcel Number: 873190 0650
Project Description: Upgrading panel from 100 amp to 200 amp
Owner Applicant Contractor
Stephan M Ahnert &Menard M Ahnert MR ELECTRIC OF TACOMA MR ELECTRIC OF TACOMA
32109 33RD AVE SW PMB 260 PMB 260
FEDERAL WAY WA 5303 PACIFIC HWY E 5303 PACIFIC HWY E
98023-2275 TACOMA WA 98424 (253)537-5208/74
Electrical Fixtures
Alt.Serv./Feeder:0 to 200 amps-Res. 1
PERMIT EXPIRES December 2,2003.
Permit issued on June 5,2003
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy an e use will be in accordance with the laws,rules and regulations of the State of Washington and
the City of Fede 1 ay.
Owner or age : .16'-<-1 .41WDate: 1 S , OG
•n
6 e- (4 .--17? 0 Z l_/ D/VS L-1) a., �/ ey1 — C
7
09.E -7 -
w
Rough-in inspection:
Date
Service inspection:
Date
FINAL inspection: 6^Ig-GL.-
Date
Date
S
CONSTRUCTION PERMIT APPLICATION
CITY OF RECEIVED APPLICATION NUMBER: 6$5- L(JC-a31 -
Federal Way APPLICATION NUMBER: -
JUN 0 5 2003 APPLICATION NUMBER: -**Thcared information-Please print(in ink)or type** 7S £ £( ` Li/
oERAL WAY
Please note: Electrical,Fire efippyis and Engineering permits may require a separate application. /-14-ri
V PROPERTY INFORMATION
Al
SITE ADDRESS: "{ ,2.sq� ASSESSOR'S TAX/PARCEL#: -
LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY):
■ PROJECT INFORMATION
TYPE OF PROJECT(This application): A❑ BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION
)(ELECTRICAL ❑ ENGINEERING ❑ FIRE PREVENTION SYSTEM
PROJECT DESCRIPTION(Provide detailed description): t T . (rQ f('OVIA 16(r + Z-W PciaP
PROJECT NAME:
• PROJECT INFORMATION
PROPERTY OWNER: NAME: DAYTIME PHONE:
V�"ire, VWm�va (s- )g1(4 -651D
MAILING (STREET 0 0••ry.;CITY,STATE, ):
ZD 33,s S-l) - 1A6_11, Wait ], , WA 4So23
CONTRACTOR: NAME: DAYTIME PHONE:
A FL�TtC CF (253-) 752 - OP(
MAILLNPy) 2c � STATE,ADDRESS;CITY TG )('W'- 6'4254 ( 75Z (- I
CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER: '/I
2_0L9 2- - l DZI_ 13"-( z.53 )2_,71/ - P7W
CONTRACTORS REGISTRATION NUMBER: EXPIRA DATE:
(copy of and requires VLA E L E -r o a / 0/ / 0
APPLICANT: NAMEE: DAYTIME PHONE:
)
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE:
( )
RELATIONSHIP TO PROTECT: FAX NUMBER:
❑ARCHITECT ❑TENANT ❑OTHER(DESCRIBE): ( )
E-MAIL ADDRESS:
CONTACT PERSON FOR THIS PROJECT: o PROPERTY OWNER ❑APPLICANT CONTRACTOR
• PROJECT INFORMATION
EXISTING USE: EXISTING BUILDING ASSESSED/APPRAISED VALUATION $
PROPOSED USE: PROPOSED VALUATION FOR IMPROVEMENTS: $
SPRINKLERED BUILDING? o YES o NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED: ❑YES ❑NO
WATER SERVICE PROVIDER: ❑ LAKEHAVEN a HIGHLINE ❑TACOMA ❑ PRIVATE(WELL)
fA ELECTRICAL
TABLE B
NEW RESIDENTIAL SERVICES MOBILE HOMES MISC EQUIPMENT/TEMP SERVICES
_Single Family _Service or feeder only $57.00 _#of Thermostats(First-$43.00;add'n-$13.00ea)
(First 1300 ft2-$85.50;Each add'n 50011 2-$27.50) T Service and feeder $93.00 _#of Low voltage fire or burglar alarms
Square Feet: First 2500 1t2-$50.00;Each add'n 2500112-$13.00
_Each outbuilding or garage $35.50 MOBILE HOME/RV PARK Square Feet:
(Inspected with service) _#of service or feeders *Per WAC 296-46-910(5)(b)(i&ii)
_Each outbuilding or garage $57.00 (First service/feeder-$57.00;Add'n service/ _#of Signs(First sign-$43.00;add'n sign
(Inspected separately) feeder-$37 each) $20.00 each)
_Swimming pool,hot tub,spa $85.50
_Yard Pole meter loops $57.00
NEW MULTI-FAMILY COMMERCIAL/INDUSTRIAL COMMERCIAL/INDUSTRIAL
(Includes three units or more) Altered Service or Feeders
Service Feeder Amps Service or Add'n _0 to 200 $ 93.00
Up to 200 amp $ 93.00 $ 27.50 Feeder _201-600 216.50
_201-400 amp 115.50 57.00 _0 to 100 $ 93.00 $ 57.00 _601-1000 126.50
_401-600 amp 158.50 78,50 _101-200 115.50 72.50 _over 1000 363.00
_ (1
601-800 amp 202.50 108.50 _201-400 216.50 85.50 _#of circuits
_Over 800 amp 289.50 216.50 _401-600 252.50 101.00 -5 circuits-$72.50;Add=n circuits,$6 ea)
ALTERED SINGLE/MULTI FAMILY _601-800 326.50 138.00
(When inspected separately from the services.) _801-1000 399.00 166.50 TEMPORARY SERVICE
Service or Feeder _Over 1000 434.50 232.00 ResidentiallMulti-Family/Commercial/Industrial
I 0 to 200 amp $ 71.50 _Over 600 volts surcharge 72.50 _0-100 $ 57.00
_201-600 amp 115.50 _Mast or meter repair 78.50 _101-200 72.50
_over 600 amp 174.00 _201-400 85.50
_Mast or meter repair 43.00 _401-600 115.50
_#of circuits over 600 125.00
(1-4 circuits-$57.00;Add'n circuits$6 ea)
If a new or altered commercial service is 200 amps or greater,or a new or altered residential service is greater than 400 amps,a plan review is required.Fee is 35%of
permit fee+$72.50.Add=1 plan review for other submissions is$85.50/hr.
FIXTURE DESCRIPTION(A) FIXTURE FEE FROM TABLE B(B) NUMBER OF UNITS(C) TOTAL(D)
TOTAL COLUMN(D):
Total Column(0)
Estimated Permit Fee: (12) 1 1 '50
Estimated Permit Fee from line 12
Estimated Plan Review Fee: $72.50+( X.35)=(13)
• DEMOLITION
Estimated Permit Fee: (14)
Bond Amount:(15)
• ENGINEERING
Estimated Permit Fee:(16)
Bond Amount: (17)
• OTHER FEES
Mitigation Fee:(18) (20) (22)
SBCC Surcharge:(19) (21) (23)
Total (Pages One&Tyro): Line(s)(11)+(12)+(13)+(14)+(15)+(16)+(17)+(18)+(19)+(20)+(21)+(22)+(23)= (24)$ 7) 'gO