19-103278 Building - Single Family
City of Federal way Permit #:19-103278-00-SF '
Community Development Dept.
33325 8th Ave S
Federal Way,WA 98003 Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax(253)835-2609
•
Project Name: RETREAT MEADOWS LOT 2
Project Address: 35613 2ND AVE SW Parcel Number:724290 0020
Project Description: **BLUE BEAM** NEW Construction of a 3264 square foot 2-story single family residence
with a 60 square foot covered entry and a 420 square foot attached garage. Includes plumbing
and mechanical. ***4 Bedrooms;$350,000 Estimated Selling Price***
Owner Applicant Contractor Lender
LENNAR NORTHWEST INC SPENCER FITCHLENNAR LENNAR NORTHWEST INC OWNER IS LENDER
33455 6TH AVE S SUITE 1-B NORTHWEST INC 33455 6TH AVE S SUITE 1-B
FEDERAL WAY WA 98003 33455 6TH AVE S UNIT 1-B FEDERAL WAY WA 98003
FEDERAL WAY WA 98003
Census Category: 101 -New Single Family House
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 3,264.00 0.00
Additional Permit Information
New/Additional Sq.Feet-1st Floor 1645 New/Additional Sq.Feet-2nd Floor 1619
New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 3264
New/Additional Sq.Feet-Basement 0 Basic Plan? No
Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck • 0
New/Additional Sq.Feet-Garage 420 Mechanical to be Included? Yes
Plumbing Work Valuation9 20000 Mechanical Work Valuation? 10000
Number of Stories 2 New/Additional Sq.Feet-Other 60
Plumbing to be Included9 Yes New/Additional Sq.Feet-Total 3744
Will Certificate of Occupancy be Issued9 Yes Occupancy#1-Use Residence(1 or 2
family)
Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2
Residential
Total Valuation:421,343.04
Ducting 1 Fans 5 Fireplace Inserts 2
Furnaces 1 Gas Piping 1 Gas Pipe Outlets 5
Hot Water Tanks
�, �'�'ATF '� x: :<` ^�
rvir�. Y, g - -i <` - r 3
Bathtubs 2 Dishwashers I Laundry Washer Outlets 1
Lavatories 5 Showers 1 Sinks 1
Water Closets 3 Hose Bibbs 2
i •
. ., PERMIT EXPIRES Sunday, 16 February,2020
Permit Issued on Tuesday,August 20,2019
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and th use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way. ^
Owner or agent: Date: V
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance,this structure was in
compliance with the various ordinances of the City regulating building construction or use.This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: RETREAT MEADOWS LOT 2 Permit# 19-103278-00-SF
Address: 35613 2ND AVE SW
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 3,264.00 0.00
Owner Name: LENNAR NORTHWEST INC
Owner Address: 33455 6TH AVE S SUITE 1-B
FEDERAL WAY WA 98003
C' 114(1/6" Pl y/v›-o
Building Official Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
t S ' .
• THIS CARD IS TO REMAIN ON-SITE
Federal Way Construction Inspection Record
y INSPECTION REQUESTS:(253)835-3050
PERMIT#: 19 103278 00 Address: 35613 2ND AVE SW
Project: LENNAR NORTHWEST INC FEDERAL WAY WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
El SWM Precon Site Mtg(4400) 0 Initial Erosion Control(4365) Ij Footings/Setback(4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date By Date
By Date 3
® Foundation Wall(4115) 0 Drainage/Downspout(4040) 0 Plumbing Groundwork(4190)
Approved to place concrete , Approved to backfill Approved to cover
N Q
By Date
5tiBy (.05 Date 7 70 By keV Date o
0 Slab/Concrete Floor(4255) ® Underfloor Framing(4285) ® Floor Sheathing(4105)
Approved to place concrete Approved to sheath floor Approved to install flooring
By Date By 6e4/ Date
By Date
El Shear Walls(4245) El Roof Sheathing(4220) El Rough Plumbing(4230)
Approved to install siding Approved to install roofing Approved
By Date If)-. - , By 5 Date 0 I t' By lwS Date IP 1
El Mechanical Rough-in(4165) ! 144 p • Gas Piping(4125) ElFire/Draft Stops(4095) Y
Approved i ( 1 f•C I Approved to release test Approved
By A.A. ate Go 2 /
ByA.A. Date B
Date /D ,2
/-
El Interim Erosion Control(4370) Prior to scheduling a Framing inspection; El Framing(4120)
Approved Electrical,Numbing&Mechanical Rough-ie
and Fire/Draft Stop inspections must be signed- Approved to insulate
•
By Date off and approved. IBC 109.3.4
By Date Q ' 'l
El Insulation(4150) El Gypsum Wallboard Nailing(4130) El Final Erosion Control(375)
Approved to install wallboard Approved to install mud&tape Approved
� I
By £ Date /0 ,..i Bye 4 Date/O 3 / By Date
i_
0 4065 Final-Mechanical
( ) El Final-Plumbing(4075) El Final-Building(4050)
Approved Approved
A);
Approved
A); Date / _ .20.2„9 By/4D S Date / „ k # B W Date
yL l / 0 2i
u ,` °K -Iw5 Y/3iy
J firConitMTs fT;,14,,L
•
El Rough Electrical El Final Electrical Right of Way
Approved Approved Approved
By Date By Date
By Date