03-105174 City of Federal Way
Community Development Services Electrical Permit #:03 - 105174 - 01 - EL
33530 1st Way S
Federal Way,WA 98003-6210
Ph:253 661 4000 Fax 253.661.4129 Inspection request line: 253.835.3050
Project Name: METROPOLITAN MARKET
Project Address: 1618 SW DASH POINT RA, Parcel Number: 122103 9074
Project Description: Installing new 3000 amp 120/208V 3PH service&wiring new grocery store for lights,outlets,&
equipment. Relocate existing U/G secondary service laterals feeding existing services to new PSE
padmount locations,install new site lighting& 125 amp site lighting service at existing parking lots.Also
includes L/V wiring for new Fire Alarm system. **3-18-04: Substantial revisions to plans for
layout/architectural changes**
Owner Applicant Contractor
FOOD MARKETS NORTHWEST,INC*Mr TI R MARTIN ELECTRIC INC R MARTIN ELECTRIC INC
4045 DELRIDGE WAY SE SUITE 111 3615 132ND ST SW SUITE A 3615 132ND ST SW SUITE A
SEATTLE WA 98106 LYNNWOOD WA 98037 LYNNWOOD WA 98037
(425)742-0852
Electrical Fixtures
Description Quantity Description (Quantity L Description Quantity
Low Voltage Fire Alarm-Commercia 34327 Service/Feeder.101-200 amps-ComI 13 Service/Feeder:201400 amps-Comr 5
Service/Feeder:801-1000 amps-Com 1 Service/Feeder:over1000 amps-Corn 1
PERMIT EXPIRES October 9,2004.
Permit issued on April 12,2004
I hereby certify that the above information is correct a i d that the construction on the above described property and
the occupancy and the use will - in accordance wi the laws,rules and regulations of the State of Washington and
the City of Federal Way.
://4/d
Owner or agent: �/� /� L� Date:
FINAL
ED
Nov 19 03 12: 42p p, 1
- : • i 2•11111, /0 Iiir 0 G(-
RECEIVED
.
`' ,,,,, ��;��, 203 CONSTRUCTION PERMIT APPLICATION
FCITY car APPLICATION NUMBER: 03 - i_ 0 67/ J1 -Oca
ederal Way CI-TYQi= FEDEF'AL VvW,f APPLICATION NUMBER: — —
BUILL!N( k!% '-!, APPLICATION NUMBER:
41¢1
'":- **The following is required information-Please print(in ink)or type**
Please note: Electrical,Fire Prevention Systems and Engineering permits may require a separate application.
• PROPERTY INFORMATION
SITE ADDRESS: 1620 SW DASH POINT ROAD ASSESSOR'S TAX/PARCEL#: _1221039074_
LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY):
A PORTION OF THE NE 1/4, OF SEC. 12, TWP 21N., RNG 3E., W.M
• PROJECT INFORMATION
TYPE OF PROJECT(This application): BUILDING PLUMBING MECHANICAL DEMOLITION
x ELECTRICAL ENGINEERING FIRE PREVENTION SYSTEM
PROJECT DESCRIPTION(Provide detailed description): Install a new 3000 Amp 120/208V 3PH service and wire new grocery store for
lights, outlets, and equipment. Relocate existing underground secondary service laterals feeding existing services to new PSE
padmount locations,install new site lighting and 125 amp site lighting service at existing parking lots.
PROJECT NAME: Metroplitan Market
• PROJECT INFORMATION
PROPERTY OWNER: NAME: DAYTIME PHONE:
FOOD MARKETS NORTHWEST ( 206 ) 923-3700
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP):
4045 DELRIDGE WAY SW. SUITE 111, SEATTLE, WA 98106
CONTRACTOR: NAME: 1 DAYTIME PHONE:
R.MARTIN ELECTRIC,INC ( 425 ) 742-0852
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE:
3615 132ND ST SW SUITE A LYNNWOOD, WA 98037 ( 425 ) 508-4830
OF FEDERAL WAY BUSINESS LICENSE NUMBER: / FAX NUMBER:
— _ 4:31/B� _ _ ( 425 ) 742-0929
CONTRACTOR'S REGISTRATION NUMBER: _ TT-- — — EXPIRATION DATE:
(copy of card required) R M A R T E I O 8 3 0 5_ _ O9/25/04
APPLICANT: NAME: DAYTIME PHONE:
SAME AS CONTRACTOR ( ) -
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): /EVENING PHONE:
( )
RELATIONSHIP TO PROJECT: FAX NUMBER:
ARCHITECT TENANT OTHER(DESCRIBE): ( ) -
E-MAIL ADDRESS:
CONTACT PERSON FOR THIS PROJECT: PROPERTY OWNER AFPLICANT X CONTRACTOR 1
• PROJECT INFORMATION
EXISTING USE: GRCOERY STORE/ RETAIL EXISTING BUILDING ASSESSED/APPRAISED VALUATION $
PROPOSED USE: GROCERY STO E/RETAIL PROPOSED VALUATION FOR IMPROVEMENTS: $
SPRINKLERED BUILDING? X YES NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED: X YES NO
WATER SERVICE PROVIDER: LAKEHAVEN HIGHLINE TACOMA PRIVATE (WELL)
Nov 19 03 12: 42p p.. 2
SEWER SERVICE PROVIDER: LAKEHAVEN HIGHLINE PRIVATE(SEPTIC)
**NEW RESIDENTIAL CONSTRUCTION ONLY**
NUMBER OF BEDROOMS: ESTIMATED SELLING PRICE: $
• PROJECT FLOOR AREAS
FLOOR EXISTING SQ.FT. PROPOSED SQ.FT. TOTAL
BASEMENT
FIRST 32147
32147
SECOND 2180 2180
THIRD
FOURTH
OTHER FLOORS(DESCRIBE)
DECK
GARAGE
HOW MANY FLOORS?
34327 34327
TOTAL:
• FIXTURES
Indicate number of each type of fixture
MECHANICAL
AIR HANDLING EVAPORATIVE
UNITS) COOLER(S) GAS LOG(S) REFRIG.SYSTEM(S)
BBQ(S) FAN(S) HOOD(S) WOODSTOVE(S)
BOILER(S) FIREPLACE INSERT(S) FLANGE(S) MISC.( - )
COMPRESSOR(S) FURNACE(S)
DUCT(S) GAS PIPE OUTLET(S) HEAT SOURCE: ELECTRIC GAS
PLUMBING
BATHTUB(S) LAVATORY(S) URINAL(S) WATER HEATER(S)
DISHWASHER(S) SYS. RAIN WATER VACUUM BREAKER(S) ELECTRIC GAS
DRINKING SHOWER(S) WASH MACHINE
FOUNTAIN(S) OUTLET
GAS PIPE OUTLET(S) SINK(S) WATER CLOSET(S) MISC.(
INTERCEPTOR(S) SUMP(S)
• DISCLAIMER/SIGNATURE BLOCK
I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and
further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I
further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the
investigation and defense of such claim),which may be made by any person,Including the undersigned,and filed against the City of
Federal Way,but only where s claim arises out of the reliance of the city,including its officers and employees,upon the accuracy
of the information supplie• • city as a pa f this plication.
NAME/TITLE: -.1/7 DATE: 09M
PROPERTY OW R APPLI • X CONTRACTOR
Nov 19 03 12: 43p p. 4
Estimated Permit Fee: (4)
Estimated Plan Review Fee: (5)
■ FIRE PREVENTION SYSTEM
PROPOSED VALUATION:
FEE FACTOR FROM TABLE A: Number: (a) Base Fee:
(b)Additional Increment Fee:
Estimated Permit Fee: (6)
Estimated Plan Review Fee: (7)
• PLUMBING
Base Fee Number of Fixtures
$26.00+{ X$9.00/fixture}= (8)Estimated Permit Fee
Estimated Permit Fee
X .65= (9)Estimated Plan Review Fee
Miscellaneous Fixture Charge:(10)
Sub Total (Page One): Line(s) (1)+(2)+(3)+(4)+(5)+(6)+(7)+(8)+(9)+(10)= (11) $0.00
TABLE B 31-c52„7
NEW RESIDENTIAL SERVICES MOBILE HOMES MISC EQUIPMENT/TEMP SERVICES ((
Single Family _Service or feeder only $57.00 #of Thermostats(First-$43.00;add'n-$13.00ca)
(First 1300 02-$85.50;Each add'n 500 ft2-S27.50) _Service and feeder $93.00 L#of Low voltage fire or burglar alarms
Square Feet: First 2500 ft2-$50.00 Each add'n 2500 l .00
Each outbuilding or garage $35.50 MOBILE HOME/RV PARK Square Feet: � / Jov- )0
(Inspected with service) _#of service or feeders *Per WAC 296-46-910(5)(b)(i&ii)
_Each outbuilding or garage $57.00 (First service/feeder-$57.00;Add'n service/ _#of Signs(First sign-S43.00;add'n sign
(Inspected separately) feeder-S37 each) $20.00 each)
_Swimming pool,hot tub,spa $85.50
_Yard Pole meter loops S57.00
NEW MULTI-FAMILY COMMERCIAL/INDUSTRIAL COMMERCIAL/INDUSTRIAL
(Includes three units or more) Altered Service or Feeders
Service Feeder Amps Service or Add'n _0 to 200 $ 93.00
_Up to 200 amp S 93.00 $ 27.50 Feeder _201-600 216.5(1
_201 -400 amp 115.50 57.00 _0 to 100 S 93.00 S 57.00 _601-1000 326.5(1
401 -600 amp 158.50.... 78.50 /3 101 -200 115.50 72.50' _over 1000 363.00
_601 -800 amp 202.50 108.50 5 201 -400 216.50............85.50- #of circuits
_Over 800 amp 289.50 216.50 _401 -600 252.50 101.00 (1-5 circuits-572.50;Add=n circuits,S6 ea)
ALTERED SINGLE/MULTI FAMILY 601 -800 326.50 138.00
(When inspected separately from the services.) T-801 -1000 399.00 166.50- TEMPORARY SERVICE
Service or Feeder T Over 1000 434.50' 232.00 Residential/Multi-Family/Commercial/Industrial
_0 to 200 amp S 71.50 _Over 600 volts surcharge' 72.50 _0- 100 $ 57 00
201 -600 amp 115.50 _Mast or meter repair 78.50 101 200 2
8...
over 600 amp 174.00 - - 50
_201 -400 85.50
_Mast or meter repair 43.00 _401 -600 115.50
_#of circuits over 600 125.00
(1-4 circuits-557.00;Add'n circuits$6 ea)
If a new or altered commercial service is 200 amps or greater,or a new or altered residential service is greater than 400 amps,a plan review is required.Fee is 35%of
permit fee+572.50.Add=1 plan review for other submissions is$85.50/hr.
FIXTURE DESCRIPTION(A) FIXTURE FEE FROM TABLE B(B) NUMBER OF UNITS(C) TOTAL(D�
3000A SERVICE r' 434.50 1
101 TO 200 AMP FEEDER/PANEL 72.50 13 434.50 l
924.50
201 TO 400 AMP FEEDER/PANEL 85.50 5 / L 1. SD 4.2.5.443,
801 TO 1000 AMP FEEDER/PANEL- 166.50 1 ' 166.50
EIRE ALARM/LOW VOLTAGE FIRST 2500 SF$50.00 1 50.00
FIRE ALARM/LOW VOLTAGE EA ADDITIONAL 2500 SF$13.00 y3- (1 1 43 1.69A8- / 00
TOTAL COLUMN(D): 7 x$2,17/0.00
Total Column(D) (a5.(0-1---
0 5.(p.� /a•5 0_R ,�l.P.(0 pi. V
Estimated Permit Fee: (12) $2,170.00 16 53_00 (-t-✓rn.vi-
Estimated Permit Fee from line 12 )93.00 L/,V r
Estimated Plan Review Fee: $72.50 + ( $2,170.00 X.35) _ (13) $1,591.50
.711( tO