17-105589 , Sign City y ral Way Permit #:17-105589-00-SG Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax (253)835-2609 Project Name: KAISER PERMANENTE Project Address: 301 S 320TH ST Parcel Number: 172104 9105 Project Description: Install(2)internally illuminated channel letter wall mounted signs and(1)internally illuminated monument signs.To attach to existing J-boxes Owner Applicant Contractor GROUP HEALTH COOPERATIVE TUBE ART DISPLAYS INC(ELECTRICAL TUBE ART DISPLAYS INC(ELECTRICAL 12501E MARGINAL WAYS 04) 04) TUKWILA WA 98168 2730 OCCIDENTAL AVE S TUBEADI110NH(8/8/19;.- SEATTLE WA 98124-1333 2730 OCCIDENTAL AVE S SEATTLE WA 98124-1333 Free Standing Sign Information Reg.# Sign Type Illuminated #Sign SetbackSign Face Sign 'Sign Height ase Landscape Faces (Ft) (Width(Ft.) Height „,-(Ft.) H t(Ft.) Area(Sq Ft.) Sign A N/A Monument Yes 2 3.00 10.00 Nt0 51.X, 1.00 100.00 .s`' ki.4 Wall Si• I nn'ationh Reg.# Sign Type 4 nated #Sign Face Sign Face Building 'o/ Faces CWidth(Ft.) Height(Ft) Elevation Sign A N/A ChannejpLetter /'Yes t 3 19.00 3.00 West Sign B West Chann �tlsrs ;�` Yes 1 19.00 3.00 East / 0 Additi al PPrmtieformation Comprehensive Plan Designation "'Park Zoning Designation OP EIT EV SS Monday, 16 July,2018 ti. t Issued Wednesday,January. 17,2018 I hereby certify that th ov;: nformation is correct and that the construction on the above described property and the occupancy and `e use will be in accordance with the laws, rules and regulations of the State of WThi ton and the City of Federal Way. u/ Owner or agent: 1 Date: / /9/2 r THIS CARD IS TO REMAIN ON-SITE CITY OF .. Construction Inspection Record Federal Way INSPECTION REQUESTS: (253)835-3050 PERMIT#: 17 105589 00 Address: 301 S 320TH ST Project: GROUP HEALTH COOPERATIVE FEDERAL WAY WA 98003-5200 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 1❑ Footings/Setback(4110) ❑2 Final-Electrical(4055) 3❑ Final-Sign(4085) Approved to place concrete Approved Approved By Date l/ /'j?.. By Date By Date ® Attachment(4010) Approved By Date • El Rough Electrical ❑ Final ElectricalEllRight of Way Approved Approved Approved By Date By Date By Date R RECEIVED NOV 1 7 201T CITY OF ' �"*',---z*%` CITY OF FEDERAL WAY SIGN PERMIT Federal Wa COMMUNITYDEVELOPMENT Y APPLICATION PERMIT NUMBER — I 0 5 i /i J- TARGET DATE ' 41-7-- SITE ADDRESS 301 S 320th St BUSINESS NAME ON SIGN Kaiser Permanente ASSESSOR'S TAX PARCEL# 172104 9105 _— _ ZONING DESIGNATION OP ELECTRICAL INCLUDED(Attaching to existing J-box) Yes/No Yes PROJECT VALUE $ 250,00.00 DETAILED PROJECT DESCRIPTION Install 2 wall signs and 1 monument sign SIGN OWNER: NAME Kaiser Permanente PRIMARY PHONE ( ) _ MAILING ADDR $ FAX NUMBER Site address ( ) - CITY STATE ZIP CODE E-MAIL ADDRESS CONTRACTOR: NAME TubeArt OFF(206) 264 264 -2954 MAILING ADDRESS CELL PHONE 11715 SE 5th ST (CITY Bellevue WA ZIPG ` 005 EMAIL ADDRESS shawnb@tubeart.com WA STATE C Q$S bISi11 QS ExPjl,}"LU FEDERAL ICENSE: 2000A101Y N79ESS L5 00 BL APPLICANT NAME Same as contractor PRIMARY PHONE ( ) - MAILING ADDRESS FAX NUMBER ( CITY STATE ZIP CODE E-MAIL ADDRESS PROJECT NAME PRIMARY PHONE E-MAIL ADDRESS: CONTACT Shawn Bowen ( 206 264 - 2954 shawnb@tubeart.corn I certify under penalty of perjury that the information furnished by me Is true and correct to the best of my knowledge,and further,that I am authorized by the owner of th ffbo ises to perform the work for which the permit application is made. + - 1 SIGNATURE t DATE: l I (, PRINT NAME --� f(, 4 . PERMIT CENTER+33325 8T"AVENUE SOUTH+FEDERAL WAY,WA 98003-6325+253-835-2607+FAX:253-835-2609+permitcenterfa`.citvofIederalway.com PROVIDE THE FOLLOWING INFORMATION FOR EACH PROPOSED SIGN FREE STANDING SIGNS SIGN TYPE SIGN AREA ILLUMINATED? LANDSCAPING TOTAL BASE (Monument,Pedestal,Pole) (#of faces x 2) (square feet) HEIGHT HEIGHT A Monument 80 Yes 100 5' 1' 0" B C SUBJECT PROPERTY'S FRONTAGE ON PUBLIC RIGHT OF WAY(LINEAR FEET): 000' 011 BUILDING MOUNTED SIGNS SIGN TYPE SIGN AREA ILLUMINATED? BUILDING ELEVATION EXPOSED (Cabinet,Channel Letter,Awning,etc.) (N,S,E,W) BUILDING FACE A Channel Ltrs 33.5 yes west 2464 B Channel Ltrs 59.7 yes east 2662 C D LARGEST EXPOSED BUILDING FACE(SQUARE FEET): 3000 + EXEMPT SIGNS SIGN TYPE SIGN AREA SIGN HEIGHT NUMBER OF (Directional,Instructional,tenant panel,etc.) SIGNS E-1 E-2 E-3 E-4 E-5 Bulletin#102—May 3,2016 Page 2 of 3 k:/Handouts/Sign Permit Application a SIGN PERMIT SUBMITTAL CHECKLIST APPLICATIONS WILL NOT BE ACCEPTED AT THE COUNTER UNLESS ALL REQUIRED INFORMATION IS PROVIDED SUBMITTAL REQUIREMENTS FOR ALL SIGN PERMITS COMPLETED PERMIT APPLICATION APPLICATION FEES Two(2)COMPLETE SETS OF PLANS(ASSEMBLED AND STAPLED INTO SETS) MINIMUM PLAN SIZE —11"X 17" ❑ PLANS DRAWN To SCALE AND SCALE PROVIDED ❑ S TE PLAN: Scale (1"=20') Location of ALL proposed signs,including refaces North arrow Each sign alpha labeled consistent with application Property lines and building footprint Location of all existing signs to remain Location of suite,if multi-tenant ❑ Location of all existing signs to be removed DDITI NAL REQUIREMENTS FOR WALL OUNTED SIGNS ELEVATION DRAWINGS DETAILS ❑Scale('/e" =1') Scale ocation and size of all signage including: o Sign materials,color and illumination type Existing signs to be removed o Actual weight of sign or individual letters ❑ Existing signs to remain on each facade ❑ Cross-section showing scaled width of sign: o Proposed signs if canopy or awning,show entire building including awning/canopy and color scheme Dimensions of each building face or suite façade Calculated total building face area Method of attachment,size/type of ❑ alculated total sign face area OR connector AND Calculated total area of individual signage Site-specific installation details (what sign is j omponents (letters,numbers,logos,etc.) attached to in field),placement and ❑ E ch proposed sign alpha labeled consistent construction with application Each proposed sign alpha labeled consistent with application 1 AD ITIONAL REQUIREMENTS FOR FREE-STANDING SIGN LANDSCAPING PLAN(IN ADDITION TO OVERALL SITE PLAN) r, ELEVATION DRAWINGS Minimum scale 1"=20' ❑ ,cale Footprint and dimensions of sign ❑ sign materials,color&illumination type Setbacks from property line(s) o Sign face/panel/base dimensions Show point of measurement for location of ■ Calculated total sign/panel area property line(s)using fog-line,sidewalk,L it Base materials&how harmonious w/building and/or edge of pavement • Foundation type ❑ Show location of driveways)and streets) r Alpha labeling consistent with application ❑ Dimensions of landscape area ■ CROSS-SECTION ❑ Type&location of landscape vegetation ■ Scale ❑ alculated area of landscaping (minus footprint of sign) • Edge of landscaping area 0 DETAILS ■ Existing&finished grades surrounding sign ❑ Foundation/footing information • Total sign height from average grade Wind load calculations (for signs 6' &over) Bulletin#102—May 3,2016 Page 3 of 3 k:/Handouts/Sign Permit Application 1 1,-0" 10'-0" I. A 7 0 I O © 0 yO . � 7 0 0 Owin ,..___„ ,�iKAISER ' EMANETE o I' ,..e!._.,., .. _.._,,,..,... 4..,..,:..„,..........6 _- ' - + CI 7:--- r.. _,._,, - e �S': Rl:ao o m r;d?'P ',KI 5 ,=; 5'- -b r- _ � QD N O ,3.... ,.. .. ....,,......„... .=. ,„...,... ..„.. .=.:„.,..,. ... , ... C t? V N Federal Way Medical Cente .a:, :'4:: o;_. : •o.A_ ;-a:b: ob_4 cr, T 301 S 320th St. meoac 4 . — N i5C NO Emergency Services 0 A. �M © a. .. I I O at o © © o pi II _;,1.___ O Side w O Front View Power Scale:Vie3/8" = 1' 0" Scale:3/8" = 1,-0.. ' 0" Conduit —Sign C a Manufacture and install one (1) double face internally illuminated monument sign. ®A Cabinet to be SignComp Series 12 hinge body with flush face retainers extrusion painted White 19 (Matthews Designer White MP31645 LVS),Silver 21 (MP18071 LSV)and Blue pms#307C(continuation of'NO Emergency Services"panel — — to cover retainer). ©Faces to be 1/8"aluminum painted White 19 (Matthews Designer White MP31645 LVS)and Silver 21 (MP18071 LSV). 2'-0" I 1. 2'-0" , I 2'-0" 1 "Renton Medical Center copy and address to be routed with pushed through clear acrylic,backed with 3/16",#2447 l. 6,-0" II" milk white acrylic. i i ©Kaiser logo to be pushed through acrylic, 1/4"net with digitally printed vinyl film overlay to match Blue 1d(pms#307C). (7, Side Section View O Front Section View ©"Renton Medical Center copy to be pushed through acrylic, 1/8"net with Med.Gray 23(3M 3635-91 Day/Night Smoke Scale:3/8" = 1'-0" Scale:3/8" = 1'-0" Gray)vinyl film overlay. ©"NO Emergency Services"panel rectangle to be routed and backed with White acrylic. "NO Emergency Services"copy to be White reverse cut from digitally printed vinyl b 'refilm background to match Blue 1d(pms#307C). ' _ `� , * F Internally illuminate with Warm White LED modules _ ' A-7.;.:-----, ; ;� r r . . t 44'7' 4 .. G LED modules to be mounted to clear acrylic support panels.Acrylic panels to be mounted to both sides support posts. '` .,.. _' 0120v or 277v power supply to be located within sign cabinet.Owner to provide electrical feed to sign location. ` ©Disconnect switch to be located on side of cabinet in an inconspicuous manner. .•. III {' 0 Support posts to be 2"x 2"x 1/4"steel square tube � • tni �' '' 04 KAISER PERMANENTE �� ©1 1/2"steel angles to be welded to support pipes and bolted to aluminum extrusion cabinet. ©Reveal to be 3"x 2"aluminum rectangular tube painted Dark Gray#5a pms#425 (MP72496LVS). Federal Way Medical Center ®Concrete base and direct burial footing recessed 3"for planting.Wind Load C80 (Sq.Ft.Area 36.32: Pressure P.S.F. 301 S 320th st. 24.34;Force Lb.884.03; Height to center 2';Moment Lb.-Ft. 1768.06) ..,2•-:“..... ' " 21 SILVER-Matthews Paint MP18071 LSV ) 19 —1 WHITE-Matthews Designer White MP31645 LVS(faces and cabinet) ' " i id BLUE-Digitally printed translucent vinyl _cl 1- Current Conditions Proposed Sign(planter bed tor ie �- to match pms#307C(KP LOGO) I —^ J U Ij [[- i 1 1 MED.GRAY-3M 3635-91 Day/Night Smoke Gray vinyl 0 Existing 100 sq ft of Type DEC 11 .-Alii m DARK GRAY-Paint MP72496 LVS to match PMS 425C 3 Landscaping Extrusion Section View CITY OF F'EDER,4'WAY Scale:3" = 1'-0" COMMUNITY DEVE'O-k,F,., Seattle Office 2520 House/II July 17,2017 [ ]Approved This original artwork is protected 11715 SE Sth Street Number Salesperson Date [ ]Approved With Changes Noted under Federal Copyright Laws. • • KAISER no reproduction of this Bellevue,WA 98005 130629SP KarenF-tseher August 3,2017 design concept without permission PERMANENTE 5 rlitter Drawn By October 16,2017 ,ndiord Signature from Tube Art Group. TUBE ART GROUP 800.562.2854 130629SP Kaiser FederalWa ,WA Fax 206.223.1123 EXT FED R6 Colors on print may not accurately y File Name Checked By Revi;:c Revisions Date depict specific colors. a „� a. .« tea.° a �, °�„, -" °. - x>.° . — .,>°7:. •,� S 320th St - 5 320tHSt - - S 320tH St •,_' �. JC, N all IMMO.: ril S 320th St S1320th St 320th ' �S 320ttiSt'`< �� Q St S 320th St S 320th St 'fS 320th St S 32bth St. S'320th St S 320th St E m.,,,,,, ; ' , At FINAL SIGN INSPECTION is REQUIRED. Call 253-835-3050 to schedule inspection. , W,a . , _ M• '' fit • f,; z,q xw+ c€• Y9• '! Y�VY L L. " r p i, ... , , ': 4,„ Sq f s t E t. if 1! ».m f $N . e• > a i rr �1 rr t la,. i { <,,. _ ., . yfl IOfI , • .—�.._..____ 4 �1lln M'. ,ate ;¢"� .. 4;0.r f f ,, . .. q e a / ° + C ' A ! '' ;'''.',I T4 , ,:.t I 301 South 32Oth Street �� Sign Code Approved: ' 8 �7yt y 1 -, _ ._..,� / sb' 44 'Y Mr , ff'r`r'xf � s.fie'.,: a'rtSr . SR litr4 , .. i ,...ur . ,... , _ ,. , , , r •• t `ryy ' , ,. , iiv' ' ,,,,),: _..,t. , ,,,..,.t....,e e , fit y" ._ ° 4 4 , > O rn 3df '`�vy �' , a '� w D Qo. - - — 'DECEIVED 'i c...) cnJ . �R :i �t t NOV � l 2017 � �m �tI°' t ,:i NOTE: DIRECTIONAL SIGNS NOT SHOWN,TAG TO CONFIRM QUANTITIES AND LOCATIONS. cn p CITY OF FEDERAL WAY D ,D ri-) CD COMMUNfTY DEVELOPMENT Z N Seattle Office 2520 House/BB July 17,2017 1 ]Approved This original artwCopyrighttilork is protectaed Ill 011715 SE 5th Street Customer Number Salesperson Date [ I Approved With Changes Noted uw --i Bellevue,WA 98005 Drawn By 130629SP Pdakender no reproducon of thiss. T. KAISER ITI J Karen Fischer _ desiyn conceptFederal without permission PERMANEME '1 206.223.1122 Quote Number Customer Signature Landlord Signature from Tube Art Group. TUBE ART GROUP 800.562.2854 130629SP Kaiser Federal Way,WA EXT FED RI Colors on print may not accurately Fax 206.223.1123 f,L•'rJe:.: Checked By Revisions Revisions Date Date depict specific colors. Exposed Bldg Face -1'4401 sq.ft. Exposed Bldg Face ' sq.ft. Sign Area Allowed 11/2 sq.ft. Sign Area Allowed i4)(47 sq.ft. c) Sign Area Proposed ` j J r sq.ft. Sign Area Proposed ) sq.ft. 112' 0" 121 ' 0" '<-- > < > T 40' 0" i p rtiiri ER terlA3VIA4 I 41 ,., w . N N • 1 Fl 4 s .„..., - iti .1cp- _, a.--,. F3 i Mt II _ _ . „ 7. g '>-,. Iiik, s�E-sac;��,--" :„,..,...ss,,z....,t. ,r ' �sC. - _ � Proposed Sign/Sign in photo shown at approximate scale: 1/8" = 1'-0" Sign A / West facing elevation Wall Area = 2464 sq ft Wall Area = 2662 sq ft Sign Area = 33.5 sq ft Sign B / East facing elevation Sign Area = 59.7 sq ft RECEIVED NOV 17 2017 �/+�.��yCIT♦Y OF FEDERALA��� WAY Seattle Office 2520 House/BB July 17,2017 [ ]Approved This original artwork is protected cOMY N�yr EI Or' 11715 SE 5th Street Customer Number Salesperson [ I Approved With Changes Noted under Federal Copyright laws. ; KAISER AG Bellevue,WA 98005 130629SP Make no reproduction of this Karen Fischer design concept without permission \ / PERMANEME 2 206.223.1122 Quote Number Drawn By Customer Signature Landlord Signature from Tube Art Group. TUBE ART GROUP 800.562.2854 130629SP Kaiser Federal Way,WA EXT FED Rl Colors on print may not accurately y Fax 206.223.1123 tie f4,:nr Checked By Revisions Revisions Date Date depict specific colors. 18" FABRICATED CHANNEL LETTERS Sign A /West facing elevation 22'-11 5/8" 2'-4 5/8" 6'-3 3/8" r 12'-8 5/8" N 1 MI MI ► I A Al, , riatil MI A 1 / A IAM „ , i „ II 5 sq ft. conduit between raceway sections painted to match raceway 9 5 sqft conduit between raceway sections painted to match raceway 19 sq ft Total sign area = 33.5 sq ft 1 KP Logo Layout Scale: 1/2"=1'-0" Sign Weight = 1751b Sign A Manufacture and Install one (1) set of internally illuminated 61/2" 6 1/2" fabricated channel letters and logo 1 1"trim cap edge Letters: Fabricated aluminum 3"deep channel construction painted Silver 21a 3/16"acrylic �. (MP18071 LVS).Concealed weep holes to eliminate light leaks. Family logo beyond LEDs II Faces to be White acrylic with 1"Silver 22 (jewelite metallic Silver)trim cap edge. 1"trim cap edge Power supply in aluminum Letters to have perforated 3M vinyl film overlay to match Blue 1 c (pms#3070). extrusion raceway 3/16"acrylic > Logo: Fabricated aluminum 6 1/2"deep channel construction painted Silver 21a(MP18071 LVS). LEDs _ _ Fasteners as required(seal Power Supply penetrations with Dow Concealed weep holes to eliminate light leaks.Faces to be White acrylic with 1"Silver 22 Corning790 ore equivalent). I (jewelite metallic Silver)trim cap edge. Logo to have perforated 3M vinyl film overlay Class 2 supply wire RI q ) Class 2 supply wire to match Blue (pms#307C).Starburst on logo to be White 3 Block-Out vinyl (3M 3635-20B). Aluminum return Aluminum return Illumination:White LEDs. and letter back ' J box baffle and letter back 40 ._, Installation:Aluminum extrusion raceways (SignComp 5"Narrow Channel Letter ILVIii I 4 1 Raceway)painted to match wall color, MP42225 LRV 69.6"White Wood". I ; ISlir."'Survey required to determine if raceways are needed and to verify wall color. ,, IDisconnect switch • • • ic BLUE-Digitally printed opaque 3M perforated vinyl to match pms#307C(KP LOGO) Disconnect switch in primary • • • 3" 3 1/2" 3" 31/2" • • • 21a SILVER-Matthews Paint MP18071LVS tobe within sight ofsign (sign includes power supply • • • enclosure) REF: NEC 110-3 • • • 3 WHITE-3M 3635-20b Block-Out vinyl [B] 600-2, 600-4 Side Section View Side Section View Perforated Blue vinyl — WHITE-Translucent acrylic 0 Scale:NTS 0 Scale: NTS Blue during day and White at night WALL COLOR-MP42225 LRV 69.6"White Wood" RECEIV Attachments - 3/8" X 4" lags into wood blocking on 4' centers ED Nov I7 2017 C1TY OF FEDPR WAY . COMMUNITY DEVEL C,PMEK Seattle Office 2520 House/BB July 17,2017 [ I Approved This original artwork is protected 11715 SE 5th Street Customer Number Salesperson F I Approved With Changes Noted under Federal Copyright Laws. • '� V^ISCR Bellevue,WA 98005 130629SP Make no reproduction of this M GR Karen Fischer _ design concept without permission PERMANENTE 3 206.223.1122 Quote Number Drawn By Customer Signature Landlord Signature from Tube Art Group. TUBE ART GROUP 800.562.2854 130629SP Kaiser Federal Way,WA EXT FED R1 ___ Colors on print may not accurately Fax 206.223.1123 lie f;a•:ie Checked By Revisions Revisions Date Date depict specific colors. . 24" FABRICATED CHANNEL LETTERS Sign B / East facing elevation 9sgft 16.7sgft 34sgft Total sign area = 59.7sgft 30'-8 3/4" 3'-1 5/8" 8'-41/2" 17'-0 1/8" i, - c� Sign Weight = 1901b r \ N N 04 \lekISER\PERN1ANENTE : � 07 = conduit between raceway sections conduit between raceway sections OKP Logo Layout Scale: 1/4"=1'-0" Sign B Manufacture and Install one (1) set of internally illuminated fabricated channel letters and logos 93/8" Letters: Fabricated aluminum 5"deep channel construction painted Silver 21a (MP18071 LVS).Concealed weep holes to eliminate light leaks. 1"trim cap edge Attachments - 3/8" X 4" lags into wood blocking on 4' centers Faces to be White acrylic with 1"Silver(Jewelite Metallic Silver)trim cap edge. I Logo: Fabricated aluminum 9 3/8"deep channel construction painted Silver 21a j (MP18071 LV). Concealed weep holes to eliminate light leaks. Faces to be White3/16"acrylic ] Power supply in aluminum extrusion raceway acrylic with 1"Silver(Jewelite Metallic Silver)trim cap edge.Logo to have new perR.)C703#smp(eulB hctam of yalrevo mlfi lyniv M3 detarofeplace starburst vinyl N. ) Fasteners as required (seal penetrations with on logo with new White 3 Block-Out vinyl(3M 3635-20B). : Dow Corning 790 or equivalent). LEDS I Illumination:White LEDs. ' J-box __ Class 2 supply wire Installation:Aluminum extrusion raceways(SignComp 8"Narrow Channel:White , Raceway)re-painted to match wall color, MP42225 LRV 69.6"White Wood". Aluminum return and letter back 1c BLUE-Digitally printed opaque 3M perforated \ — — — Disconnect switch • • • vinyl to match pms#307C(KP LOGO) • • • il • • • 21a SILVER-Matthews Paint MP18071 LVS Disconnectn switchhin primary s 4 3i8° to be within sight of sign • • • \ (sign includes power supply • • • 3 WHITE-3M 3635-20b Block-Out vinyl / \. enclosure)REF:NEC 110-3 Typical Section View [B] 600-2,600-4 REC ED Perforated Blue vinyl — WHITE-Translucent acrylic 2 Scale: NTS E' Blue during day and White at night p ]WALL COLOR-MP42225 LRV 69.6'White Wood" NOV 11 2017 CITY OF FEDERALyrs•: COMMUNITY DEyELOPIrr p Seattle Office 2520 House/BB July 17,2017 [ ]Approved This original artwork is protected 11715 SE 5th Street Customer Number Salesperson ,...> 1 1 Approved With Changes Noted under Federal Copyright Laws. ;,•• KAISER Bellevue,WA 98005 130629SP August 3,2017 Make no reproduction of this • KA Karen Fischer design concept without permission Al PERMANEE 206.223.1122 Quote Number Drawn By October 16,2017 Customer Signature Landlord Signature from Tube Art Group. M `} TUBE ART GROUP 800.562.2854 1306295P Kaiser Federal Way,WA EXT FED R6 Colors on print may not accurately y Fax 206.223.1123 File Name Checked By Revisions Date Date depict specific colors. TUBE ART GROUP 1705 4th Ave South, Seattle, WA 98134-1514 1206.223.1122 I 800.562.2854 i Fax 206.223.1123 Calculation 2014 IBC Exposure: Wind Load: I Date: 11/16/2017 Design Wind Pressure p=CeCqCf-1 Job Name: Kaiser 0-15 18.05 Location: Federal Way 15-20 19.51 Calculated By: sb 20-25 20.97 Wind Load 25-30 22.13 30-40 24.46 Overall Height: I 5'0" I 40-60 27.66 60-80 30.28 80-100 32.9 Section Height to Section Height Section Width Sq Ft.Area Pressure P.S.F Force Lb. Cntr-Ft. Moment Lb.-Ft. A 5.00 10.00 50.00 18.05 902.50 2.50 2256.25 B 0.00 0.00 0.00 0.00 C 0.00 0.00 0.00 0.00 D 0.00 0.00 0.00 0.00 E 0.00 0.00 0.00 0.00 Totals 50.00 902.50 2256.25 12 S req= (Moment Lb.-Ft.total)X 36 X.6 X 1 S req= 0.63 in3(For Double Pole Sign) 1000 Description of Pipe Required Wall Lb./Ft. Sm.in3 Option A 2-1/2" SCH 40 PIPE 0.203 5.793 1.064 Option B 2" STL SQ.TUBE 0.25 5.41 0.766 Foundation Calculation (1500 lb#Foundation/Lateral Preasure) Single Pole Sign p= 0.90 Double Pole Sign p= 0.45 h= 2.500 Double Pole A= 2.34 X p ( 0.451 ) A= 1.367 I 2.73 I /3 x .3 I 2 I 2 I (Depth) (Lat.PSF) (Fig.width) (Ftg.Length) 0.273 2.828 0.684 3.995 d= A 1+SQRT( 1+ 4.36 x h ) d= 2.732 2 A [Footing Dimentions Width: 2 Lenght: 2 Depth: 2.732 Yds.Concrete 10.404689773 Ea.Footing 0.809379547 Total Concrete Required #of Bags 43.71 Estimated Concrete Cost $ 363.78 UPDATED Feb-12 - •! 1'-0"�I 10'-0" oII 77 0 0 01) jt°1 0 o © o ID v.eo ��� r O 11111 ai1� � �#.;- �� ';-4;'�i�v� o� - �e,4'��4,; ,',�..4.vl .s:P,4-b-e r �. �m,�KA ER ' ► ' N ELATE o a. ''' ".. - . : : , ; :_a 4;,e;o; .p.:",a ' " "_AEn '- - `�' ay Medical Cente �' m RCo T �'20th St. 4..4.,'�'q1 i E 4 _f'C , NO Emergency Services - - - - - - - - - - - - o a0000000000eo _M 1 / r © tlIt I I V J _ I} O CV ' VI .. . . . . .„ ... .. . . ....r.. ... —ii— t .. . , , .• .• .•. .. .. . .. . . . . . ... . .. . • . • ^^ 0 @-/0 O pi •3=11= • li=ii l I1= i c —E =11=11' ii—�1=11 I ... . I—R (— ii ll= QSideView Front View =11=11 1=11= 11=11=11 •:.11=11=11= -11=11 I1=11=11= =1I= 11=11 1=11=11 11=11=' =11= 1 r=11=11 �Power Scale:3/8" = 1'-0" Scale:3/8" = 1'-0" 1=i1 .1=1' 11=11 ::;':.11=11= ,11= 11=11' Conduit 11— 11= 11=111.1: ':.::; =11=1 =13 11=11 =11 `1= =I1 11=1 �` r5 1i= —Sign C = N 11 -1 .S-I-e i' I' _ Manufacture and install one (1) double face internallyilluminated monument sign. I 1= i l II d fG`� 3 ?(t,t a QA Cabinet to be SignComp Series 12 hinge body with flush face retainers extrusion painted White 19(Matthews Designer �osCo, vOC' '�"„ 1,16P. ce 1 White MP31645 LVS),Silver 21 (MP18071 LSV)and Blue pms#307C (continuation of"NO Emergency Services"panel -to RCtUtAr Qcior tom, (>13„A.Q to cover retainer). r r ;.5�•• r ©Faces to be 1/8"aluminum painted White 19(Matthews Designer White MP31645 LVS)and Silver 21 (MP18071 LSV). 2'-0" 2'-0" a'� 2'-0" "Renton Medical Center"copy and address to be routed with pushed through clear acrylic,backed with 3/16",#2447 k 6'-0" milk white acrylic. Y. Y. ©Kaiser logo to bepushed through acrylic, 1/4"net with digitally printed vinyl film overlayto match Blue 1 tl (pms#307C). Side Section View Front Section View 9 Y , li Y ' Y ®Scale:3/8" = 1'-0" 0 Scale:3/8" = 1-0" Q"Renton Medical Center"copy to be pushed through acrylic, 1/8"net with Med.Gray 23(3M 3635-91 Day/Night Smoke Gray)vinyl film overlay. Q"NO Emergency Services"panel rectangle to be routed and backed with White acrylic. "NO Emergency Services"copy to be White reverse cut from digitally printed vinyl —• r. . :• , , ' T film background to match Blue 1d (pms#307C). . . ,tl. * '" '* - :, , '`3� F Internally illuminate with Warm White LED modules. ' ' r A G LED modules to be mounted to clear acrylic support panels.Acrylic panels to be mounted to both sides support posts. qtr`' `, + Y' ' `,' QH 120v or 277v power supply to be located within sign cabinet.Owner to provide electrical feed to sign location. f?`. :: �� ()Disconnect switch to be located on side of cabinet in an inconspicuous manner. ,° . Q Support posts to be 2"x 2"x 1/4"steel square tube i�1ENTE >_ KAISER PERMANENTE QK 1 1/2"steel angles to be welded to support pipes and bolted to aluminum extrusion cabinet. _., Q Reveal to be 3"x 2"aluminum rectangular tube painted Dark Gray#5a pms#425 (MP72496LVS). ('doral Way _ '""""'""' Federal Way Medical Center Nww. ®Concrete base and direct burial footing recessed 3"for planting.Wind Load C80 (Sq. Ft.Area 36.32; Pressure P.S.F. „ n‘.-,-.--, 301 s 320th sr. 24.34; Force Lb.884.03;Height to center 2';Moment Lb.-Ft. 1768.06) Notme,v `"5 - 21 SILVER-Matthews Paint MP18071 LSV 19 WHITE-Matthews Designer White MP31645 LVS(faces and cabinet) 0 1d BLUE-Digitally printed translucent vinyl " � Ir'� Current Conditions Proposed Sign (planter bed to be replaced by others) to match pms#307C(KP LOGO) I —^ 23 MED.GRAY-3M 3635-91 Day/Night Smoke Gray vinyl 0 ��, . RECEIVED Existing 100 sq ft of Type - 5a DARK GRAY-PaintMP72496LVStomatchPMS425C 3 Landscaping NOV 11 2017 O Extrusion Section View CITY OF FEDERAL Scale:3" = 1'-0" PAL WAf CONlMUNl7Y DEyELOPMEr.'- Seattle Office 2520 House/BB July 17,2017 [ I Approved This original artwork is protected under Federal Copyright Laws. A KAISER A^ 11715 SE 5th Street Customer Number Salesperson Date [ ]Approved With Changes Noted • IY1 JGJI AG Bellevue,WA 98005 130629SP August 3,2017 Make no reproduction of this Karen Fischer design concept without permission ra PERMANENTE 5 206.223.1122 Quote Number Drawn By October 16,2017 Customer Signature Landlord Signature from Tube Art Group. TUBE ART GROUP 800.562.2854 130629SP Kaiser Federal Way,WA EXT FED R6 Colors on print may not accurately Y Fax 206.223.1123 File Name Checked By Revisions Revisions Dale Date depict specific colors. Prop Line • fiber (I) fire e metro bus C\I stop co SIGN 3'-0" setback sidewalk s �, I , ee 13 -6 24 -6 4 1.41 1O'-0" , 21 '_6" cs:) CC=.41k 6D _*/K- ± cow sidewalk wheelchair ramp light ._ _ 100sgftoftype driveway landscaping Existing wheelchair ramp N RECEIVED NOV 17 2017 Plan View G M UITY N�DEvELOPMEW Scale: 1 " _ 10'-0"