12-100310 ` `'r & wilding - Single F'amiiy City of Federal Way • Community&Econ.Dev.Services = Permit #: 12-100310-00-SF 33325 8th Ave S ai Federal Way,ax 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax (253)835-2609 .,� p Q irweAr Project Name: POPAL Project Address: 30820 1ST PL S Parcel Number: 667265 0460 Project Description: REP-Replacing beam and joists and water heater& furnace in garage. Owner Applicant Contractor Lender MOHAMMED AMIN POPAL PREBEN ESPERSEN MASTERCRAFT CONSTRUCTION AMIN MINA MASTERCRAFT CONSTRUCTION SERVICES LLC 30820 1ST PL S SERVICES LLC MASTECS894BR(1/19/13) FEDERAL WAY WA 98003 PO BOX 1887 PO BOX 1887 ISSAQUAH WA 98027 ISSAQUAH WA 98027 Census Category: 434 -Residential alt/add-no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area(sq.ft.) 0 0 0 0 New/Additional Sq.Feet-3rd Hoor 0 New/Additional Sq.Feet-Basement 0 Mechanical to be Included? Yes Plumbing to be Included? No Zoning Designation RS 7.2 "T ?t$ 4 i sr.k�', , •,ski,: .'. .«. : . �..-"ti, s, AIL Furnaces 1 Hot Water Tanks 1 CONDITIONS: Subject to field inspection with engineering. PERMIT EXPIRES Sunday, July 22, 2012 Permit Issued on Tuesday, January 24, 2012 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: f � FIN ` I",IIS CARD IS TO ,MAIN ON-SITE . CITY OF 4011 0Construction In ection Record Federal Way INSPECTION REQU TS: (253) 835-3050 PERMIT#: 12-100310-00-SF Address: 30820 1ST PL S Project: MOHAMMED AMIN POPAL FEDERAL WAY, WA 98003-4081 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Underfloor Framing(4285) El Floor Sheathing(4105) El Shear Walls(4245) Approved to sheath floor Approved to install flooring Approved to install siding By Date By Date By i, .././1 Date 5.—/3 i El Roof Sheathing(4220) 0 Mechanical Rough-in (4165) '0 Gas Piping(4125) Approved to install roofing Approved Approved to release test By Date By Date By f Date 3,.,Z ' O Fire/Draft Stops(4095) - Prior to scheduling a Framing inspection; ❑ Framing(4120) Approved Electrical,Plumbing&Mechanical Rough-in and Approved to insulate Fire/Draft Stop inspections must be signed-off and By /G Date i /3•/z....- approved. IBC 109.3.4 By f Date 3--/p/Z O Insulation (4150) '0 Gypsum Wallboard Nailing(4130) 0 Final-Mechanical(4065) ' Approved to install wallboard Approved to install mud&tape Approved By ot.ii, Date F-/5 /Z By Date By v'. Date r-/l.-/2., 0 Final-Building(4050) Approved - By Date 'i /`--/-4 . ❑ Rough Electrical Final Electrical Right of Way Approved Approved Approved B Date'' --(7—• By Date By Date l34 b P n z C ' x 1 4 Q � n 4 n x . . CONSULTING • • • ENGINEERS PACIFIC NORTHWEST ENGINEERING INC. _ 12. _ p p 31 d COVI 003, SAT 1-0 January 17, 20BSEG1 �� ��� O b #12-034 Pla 1lable to knspector Mater Craft Construction Services LLC Attn: Mr. Preben Espersen X117 'fir.°` Pe �' P.O. Box 1887 Issaquah, WA 98027 Cv Subject: Structural Observation of Fire Damaged Framing Members fziv— Site: 30820 1 a Place S. _ Federal Way, WA 98003 Mr. Espersen, Pacific Northwest Engineering Inc. (PNE) as requested has visited the above noted site on 1-12-2012 to assess the structural adequacy of the framing members damaged by a fire in the homes garage. PNE evaluated the structural adequacy of the main beam running longitudinal in the garage,the floor joists supporting the room above the garage and the columns supporting the main beam. PNE finds that it is acceptable to replace the main beam(5 1/8"x13 '/2"GLB) and floor joists(2x10 HF) with framing members of the same size and grade material that was previously installed. However,the posts supporting the main beam shall be upsized due to the 14' height. The current 6"x6"does not meet current code requirements and should be replaced with either a(8"x8"HF PT Post)or(5 1/8"x 6" GLP)and shall be attached using a Simpson CCQ or AC column cap. If there are any more questions or concerns,please contact our office. Sincerely, S. & G7 of WASly/ Russell S. Bodge,P.E. a 39315,c) c Pacific Northwest Engineering, Inc. �FcrS�E� `� r.I RECEIVED Pacific Northwest Engineering Inc. ` 4 2012 1944 Pacific Ave; Ste 310 Tacoma, WA 98402 CITY OF FEDERAL WAY Phone (253) 682-2850 Fax (253) 682-2851 CDS. 1 of 6 . „or ,. .. . . # 41r ._ ., . , • • I 14'-13' 26'-0' I12'-0' N.. ‘ ... i . . i .1- ---1 1 2x10 JOISTS @ 16O.C. I- i ! . i. 1. 1 1. \ 1 i i 1 : 1 i 1.9 i • P______________________________ 4____÷.______________________________I 4 ce) ! :o u•....--. ! I. Lii i 4...---------_______—_—_— Cf%,.a'X---- 1 ------------4 1. ch I. 0 CO -0 I X" i CO , i• 0...--------------------------00 c :..."------ Z.;---------_--------1 al. • .1 :!...-------------------------0 z(6---- -----------------------____H i n 71 0 • I" I 0 tc/ I. -71C In .1 1 1. X-13 .1 -17 z r 1 1. ,r.___-_—_—______________----_______o 1.—__ • • i o i i i • ;fr--------------------------------- -----------------------------i .1 • i 4 i ,, • .1 ! 4 1 • I. /;) • .1 • • c• .1 i • 1. .1 • l• .1 • i I. .1 • 1. • • !___________________________________,______________________________4 1 i ! • t===================_==:==_= • • 26'-0' Page 2 of 6 ti CONSULTING • • • ENGINEERS PACIFIC NORTHWEST ENGINEERING INC. \ = vee �irti February 8, 2012 #12-034 Mater Craft Construction Services LLC Attn: Mr.Preben Espersen P.O. Box 1887 Issaquah, WA 98027 Subject: Structural Observation of front Garage Epoxy Anchor Installation Site: 30820 14 Place S. Federal Way, WA 98003 Mr. Espersen, Pacific Northwest Engineering Inc. (PNE)as requested has visited the above noted site on 2-8-2012 to witness the installation of the threaded rod anchors for the new TJ Shear Brace Panels to be installed. Eight 24"deep holes were core drilled into the existing concrete foundation. Each of the holes were prepared in accordance with the manufacturers instructions by washing clean, then vacuumed out and blown dry with compressed air prior to the installation of Simpson SET epoxy and the anchors. If there are any more questions or concerns, please contact our office. Sincerely, �CL� S. 6 0 Russell S. Bodge,P.E. �of wAsy14, 6 Pacific Northwest Engineering, Inc. ' In 11 /ti- -o FG 5T ERF'° 1 Pacific Northwest Engineering Inc. 1944 Pacific Ave; Ste 310 Tacoma, WA 98402 Phone (253) 682-2850 Fax (253) 682-2851 o t � - � o c� � � p__F,T.oF lip FederrE �E® C. F CO ME PL DE EN FP COMMUNITY DEVELOPMENT SERVICES APPLICATION 2.53-835-2607.FAX 253-83S-2609 ,,-, ,, ,„.,JAN 2 4 i SITE ADD€ESSTY OF FEDERAL WAY SUITE/UNIT M / cr pz S. PROJECT VALUATIO ZONING ASSESSOR'S TAX/PARCEL 8 , : Izitt.-,0 b Ce ?- ,-)-. Ce C - o 4 co 0 / 11111UILDING UJ4 LUMBING 1)-'ICECHANICAL TYPE OF PERMIT ❑ DEMOLITION ❑ ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT (Tenant Name/Homeowner Last Name) �j. A4 PROJECT DESCRIPTION l 1 Detailed description of work to t'\c..>k__ /z- 1 L R-' 1 \O 1"" be included on this permit only -R -' c e-k- ' zti'ii-c. 4- c2 -(, 'itt(-ft 1 >v h"4-c 2.4-6 c NAME PRIMARY PHONE PROPERTY OWNER ' { .i f MFS. P0 PA- L MAILINGADDRESS E-MAIL .3c E -c i - PL, CITY SiltTE ZIP ti t le / ii %Cc 3 NAM PHONE,. MAIL GRESS ff E- IL CONTRACTOR u-'0 6c)( tea,-, .1—cli U,9 K � & it etizcSit,61- CITY STATE ZIP FAX I I-C'�` IS tt;fl c7gc a 7 yes' s57- //Lb WA STATE CONTRACTOR'S LICENSE M EXPIRATI N DATE FEDERAL WAY BUSINESS LICENSE 8 N1Ac(k.C,S ci 9 bz I I X13 NAME / lz j tai vattez�iQ` PHONE / 7 / / APPLICANT MAILING ADDRES E-MAIL CITY STATE ZIP FAX PROJECT CONTACT NAME � � PHONE (The individual to receive and ' �� �'� � NZ c6.-c 2_4,6 respond to all correspondence MAILING ADD ? E-MAIL concerning this application) Sll'L"t i,t ) CITY STATE ZIP FAX ALTFRNCONTACT (fG L ��v,V ii76- Py PIR-c 2 6 z77 E-MAIL ri I L�1 '1 PROJECT FINANCING NAME 1 ❑ OWNER-FINANCED Required value of$5,000 or more (RCW 79.27095) MAILING ADDRESS,CITY,STATE,ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. �" • 2--z- /Z SIGNATURE: -- DATE PRINT NAME: Bulletin#1(1(1—January 1,2011 Page 1 of 3 k:AHandouts\Permit Application • • ;:+3 fl*. *111. „:; ". r-F et, 1 i is V VALUE OF MECHANICAL WORK $ (� (a copy of bid or estimate must be provided) Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS)commorriaq BOILERS ' FURNACES HOT WATER TANKS)cas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS)orTub/shower Combo) LAVS)Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS)Kitchen/ut;hry) WATER HEATERS(Eieetno) HOSE BIBBS SUMPS . WASHING MACHINES TOTAL PIXTVRS t- ,� X ease cw x -': CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? o Yes o No E Yes c No u�•-. a� _ w -awe ° :ag. ,;. '"� g' 42. '„.� T'A' °a» . AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE FIRST FLOOR(or Mobile Home) � e COVERED ENTRY GARAGE 0 CARPORT 0 m EXISTING PROPOSED TOTAL Area Totals . .< < k,. ,. <';<,C..,'�A,s,ilw^',{. �'1 ©ifJYY #i '�.d"j is€s-«, .,•:. .. #" yww..q 4. ESTIMATED SELLING PRICE$ I # OF BEDROOMS "-`, ."` r3`.s��'§.' ��t �`fl6. �• ,� '. .e�.� e � �` .a3 ,� �,• ^1.'^ sa't,<.s .. - - a .t�..ak.' <sr<zP.azi'¢$ ` �'� :�?�a�-�'�' AREA DESCRIPTION Area Occupancy Group(s) Construction # of Additional Information in S.uare Feet .e Stories ADDITION gg �- .. �,y�' a a'"'. F "N.. b i q _ ..y,,_= d•.z �_%;I ;�y' ,- 2,Y'l ,n g 8 a�. s�5. �• a b r i aP 'h a z• AREA DESCRIPTION Occupancy Group(s) Construction # of Additional Information Stories a ,,, 1 �: ? .' -' iSf ;TOTAL I;E� &� t �� �; TENANT AREA ONLY . [l.IECT'ARFA)D3tILXrit,144. Bulletin 4100—January 1,2011 Page 2 of 3 k:\Handouts\Permit Application