08-105209 410 Electrical
Csity of Federal Way Permit 08-105209-00-EL
(`u�.�munity Development Services
P.O.Box 9718
Federal Way,WA 98063-9718
Inspection Request Line: (253) 835-3050
Ph.(253)835-2607 Fax.(253)835-2609 p a
Project Name: DASH POINT LAUNDROMAT
Project Address: 1642 SW DASH POINT RD ' `2' Parcel Number:' 189880 0010
Project Description: Adding/altering 201-600 amp •
,t
Owner Applicant Contractor ,
DASH POINT VILLAGE LLC JOHN'S ELECTRICAL INC JOHN'S ELECTRICAL INC
PO BOX 52850 4525 S WARNER ST UNIT A8 JOHNSEI961 OM (9/14/10)
BELLEVUE WA 98015 TACOMA WA 98409 4525 S WARNER ST UNIT A8
TACOMA WA 98409
• •4,„ v. 44',94,..,,,--r.ism`.:;.. :.•.. �s.1,-ti ., «' ; �� Sa?k w. :s r _.a. ..
Service greater than 1000 Amps? No
€ q k $AV• .f
.� � �K ` ; a wa " Via•
Alt. Serv./Feed 201-600 amps(Co 1
PERMIT EXPIRES Saturday, October 31, 2009
Permit Issued on Friday, October 31,2008
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the se will be in accordance with the laws, rules and regulations of the State of Washington
and the City of Federal Way.
Owner or agent: �� Date: / O
,
EbV/14,7 /'
o1
J\
4
/ -, libi. .
THIS CARD IS TWEMAIN ON-SITE
III
CITY°F 4811 Community Development Inspection Reeord
Federal Way IVR INSPECTION REQUEST PHONE # (253) 835--3050
PERMIT#: 08-105209-00-EL
Owner: DASH POINT VILLAGE LLC
Address: 1642 SW'DASH POINT RD .
FEDERAL WAY, WA 98023
This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD.
Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not
be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections
are logged on the back of this card.
❑ UFER Ground (4295) 0 Ditch cover(4030) 0 Slab/Concrete Floor(4255)
Approved Approved Approved to place concrete
B• y Date By Date By Date
— 0 Pool Bonding(4195) ❑ Temporary Power(4275) ❑ Service(4235)
Approved Approved Approved
By Date By Date By Date
0 Feeders/Sub-panels(4045) 0 Rough Electrical(4225) ❑ Ceiling Cover(4020)
Approved Approved Approved
By Date By Date By. Date
,
0 Final-Electrical(4055)
Approved
B DateZ- (3 di
•
For inspector reference only __ _
0 Rough Electrical 0 FINAL-Electrical
Approved Approved
By Date By Date
rira. iig.- _ / 0 5-2 CD2
...E. . ' PERMIT
COMMUNITY DEVELOPMENT SERVICES SF MF CO wool, DE EN FP
33925 FEDERAL
AVENUE N•,3-9718 18 ppLI CATI O N
X607 PAX 2959-8359?609 O C T 3 i 2 ;
w.�. r / /
The follouGiR el iieglit 16 0r!W NI6mplete application will not be accepted. Please print legibly(In ink)or type.
• PROPERTY INFORMATION
SITE ADDRESS_i 61-2 .5:1.J. b 114 yy . �,i / (,e� SUITE/UNIT 9
ASSESSOR'S TAX/PARCEL 9 1 FG/ F O- 0 0 / LOT SIZE(sf)
LEGAL DESCRIPTION(e.g.Acme Estates,Lot 1)
pack
• PROJECT INFORMATION
TYPE OF PERMIT 0 BUILDING 0 PLUMBING 0 MECHANICAL •
CI DEMOLITION LECTRICAL 0 ENGINEERING 0 FIRE PREVENTION SYSTEM
PRO= D RIP�'I/(Pro ' detaneddescrip f work real on this°eermit onh
' �
PROJECT NAME(Name of Business or Owner Last Name) NA_511 rC Ary,4 )_- w ,
• PEOPLE INFORMATION
OWNER NAME'1>As� IVT V i U4 LLC_ PRIMARY PHONE -
MAILING ADDRESS CITY,STATE,ZIP E-MAIL ADDRESS
CONTRACTOR COMPANY NAME 1 _ n 1
•l-n I S F—k- 01 bt,(, t b OFFICE PHONE
i., 0 ADDRESS CITY,STATE,ZIP CELL PHONE
r (.4.3C/0"►,O,,-'-�_ 8 (.2.-3) 26 - 644?
_�• « OF FEDERAL WAY BUSINESS LICENSE NUMBER EXPIRATION DATE FAX NUMBER
4 / .mac ,d kt r ( )
CON j�CTOR'SfWTION EXPIRATION DATE EMAIL ADDRESS
See AWL
IT
APPLICANT COMPANY NAME -mc.Arrr NAME . .� OFFICE PHONE
FttNi I'S - •`- =J k ,S,. L -t* ( )
MAILING ADDRESS CTIlc,STATE,ZIP CEI1.PHONE
(z4-2) � - 044"
RELATIONSHIP TO PROJECT FAX NUMBER
0 Architect a Tenant a Agent a Other ( ) -
PROJE6T NAME PRIMARY PHONE E-MAIL ADDRESS
CONTACT ( ) -
LENDER NAME Per RCW 19.27.095:
Under information is required i fproject value exceeds$5,000
MAOJNG ADDRESS CITY,STATE,VP • PHONE
( ) -
• DETAILED BUILDING INFORMATION
.
EXISTING USE PROPOSED USE
EXISTING ASSESSED/APPRAISED VALUE$ VALUE OF PROPOSED WORK $
SPRINKLERED BUILDING? a YES O NO FIRE SUPPRESSION SYSTEM PROPOS•ED/REQUIRED? a YES O NO
WATER SERVICE PROVIDER a LAKEHAVEN O MGHLINE a TACOMA O PRIVATE(WELL)
SEWER SERVICE PROVIDER a LAKEHAVEN O HIGHLINE a PRIVATE(SEPTIC)
1
i PROJECT FLOOR AREAS
AREA DESCRIPTION EXISTING PROPOSED TOTAL
SQ.FT. SQ.FT. SQ.FT.
BASEMENT
FIRST •
`�i,rt,
SECOND •
"t
•
THIRD
ADDITIONAL FLOORS(DESCRIBE)
•
DECK(0 COVERED OR 0 UNCOVERED?)
GARAGE 0 CARPORT 0
•
>vasena more® TOTAL TOTAL=nmoar TOTAL PROPOS=are.. TOTAL al
NUMBER OF FLOORS
"NEW HOMES ONLY" NUMBER OF BEDROOMS ESTIMATED SELLING PRICE $ •
•
FIXTURES
Indicate number of each type of fudure to be installed or relocated as part of this project. Do not include existing fixtures to remain.
MECHANICAL
Value of Mechanical Work$ (A COPY OF BID OR ESTIMATE MUST BE INCLUDED WITH APPLICATION)
AIR HANDLING UNITS EVAPORATIVE COOLERS OAS PIPE OUTLETS WOODSTOVES
BBQS FANS GAS WATER HEATERS MISC(Describe)
BOILERB FIREPLACE INSERTS HOODS Kxm.ras
COMPRESSORS FURNACES RANGES •
DUCTS. GAS LAG SETS REFRIG.SYSTEMS
PLUifRiNG
BATHTUBS prTubI mal LAVS(Bathroom Bioko, URINALS MISC(Describe)
• DISHWASHERS RAINWATER SYST VACUUM BREAKERS
DRINKING FOUNTAINS SHOWERS WATER CLOSETS g.as
•
ELECTRIC WATER HEATERS SINKS WASHING MACHINES .
HOSE BIBBS SUMPS
•
SIGNATURE •
r
certify under p lty of ply that I am the property owner or authorised agent of the property owner.I certify that to the best of my
knowledge, the information submitted in support of this permit application is true and.correct I certify that I will comply with all applicable
City of Federal Wag regulations pertaining to the work authorised by the issuance of a permit.I understand that the issuance of this permit
does not remove the owner's responsibility for compliance with local,stats,or federal laws regulating construction or environmental laws.
I further agree to hold harmless the City of Federal Wag as to any claim(including costs,expenses, and attorneys'fees incurred in the
investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city,but only
where such claim out of the reliance of the city,including its officers and employees,upon the accuracy of the information supplied to
the city as a part of application.
DATE o el 3
SIGNATURE: Property Owner and/or Authorized Agent
•
•
a NEW a ADDITION a ALTERATION a REPAIRa•TENANT IMPROVEMENT
•
BUILDING SHELL ONLY? a YES a NO BASIC PLAN? a.YES a NO
ZONING DESIGNATION CHANGE OF USE? a YES a NO
NEW ADDRESS REQUIRED? a YES a NO IIP/SEPA/SII? o YES a NO
PLATTED LOT? a YES a NO DEMO PERMIT REQUIRED? a YES a NO
Bulletin#100—January 1,2008 Page 2 of 4 k\Handouts\Permit Application
ELECTRICAL PERMIT INFORMATION
•
RESIDENTIAL COMMERCIAL
NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE
❑ Single Family Square Feet Service or Feeder Each Add'n
(First 1300 ft2-$115.50;Each add'n 500 ft2-$3700) 0 0 to 100 amp $125.50 $76.50
❑ Detached outbuilding or garage 0 101-200 amp 155.50 98.00
(Inspected with service) $48.50 0 201-400 amp 291.00 115.00
❑ Detached outbuilding or garage 0 401-600 amp 339.50 136.00
(Inspected separately) $76.50 0 601-800 amp 439.00 186.00
❑ 801- 1000 amp 536.50 224.50
NEW MULTI-FAMILY(three units or more) ❑ Over 1000 amp 584.50 311.50
Service Feeder
❑ Up to 200 amp $125.50 $37.00 0 Over 600 volts surcharge $98.00
❑ 201-400 amp 155.50 76.50 ❑ Mast or meter repair $106.00
❑ 401-600 amp 212.50 106.00 ALTERED COMMERCIAL/INDUSTRIAL
0 601-800 amp 272.00 145.50
❑ Over 800 amp 389.50 291.00 Service or Feeders
❑9.bo 200 amp $125.50
ALTERED SINGLE/MULTI FAMILY a 201-600 amp 291.00
O 601- 1000 amp 439.00
Service or Feeder ❑ over 1000 amp 489.00
❑ 0to200amp $96.00
❑ 201-600 amp 155.50 ❑ #of circuits to be added/altered
❑
over 600 amp 234.00 (1-5 circuits-$98.00;Add'n circuits,$7.50/0
0 #of circuits to be added/altered COMMERCIAL/INDUSTRIAL PLAN REVIEW
(1-4 circuits-$76.50;Add"n circuits$7.50/ea) $98.00 plus 35%of Permit Fee
❑ Service- 1,000 amps or greater
❑ Mast or meter repair $57.50 0 Medical/Educational/Institutional Facility
MANUFACTURED HOMES
❑ Service or feeder only $76.50
❑ Service and feeder $125.50
TEMPORARY SERVICE
IOBU B HOME/RV PARK Residential/Multi-Family $67.50
❑ #of service or feeders
(First service/feeder-$76.50;each add'n-$50.00) CommerciaVIndustrial Service or Feeder Ampacity
❑ 0-100 amps $76.50
O 101-200 amps 98.00
❑ 201-400 amps 115.00
❑ 401-600 amps 155.50
❑ over 600 amps 168.00
MISCELLANEOUS SERVICE/EQUIPMENT
❑ #of Thermostats ❑ #of Signs
(First-$57.50;addh-$17.50/ea) (First sign-$57.50;add'n sign$27.00/ea)
❑ Low Voltage ❑ Swimming pool/hot tub $115.00
Square Feet to be served by system(s) (Includes additional circuit,if required)
O Fire Alarm System 0 Yard Pole meter loops $76.50
O Security Alarm System 0 Additional Plan Review $115.00/hour
0 Voice Cabling (for modified submittals)
O Data Cabling 0 Automation Fee on all Permits .. $5.50
0
1a 2500 R2-$67.50;
Each add'n 2500 ft2-$17.50)'Per WAC 29646.910(5)(bNi&s1
,t`
Bulletin#100-January 1,2008 Page 3 of 4 k\Handouts\Permit Application