Loading...
11-105041 w t • Sign City of Federalay Community&Econ.De.Services Permit #: 11-105041 -00-SG 33325 8th Ave S Federal Way,WA 98003 Request Inspection Re t Line: Ph:(253)835-2607 Fax (253)835-2609 p q (253)8 35-3050 Project Name: VERIZON WIRELESS Project Address: 34512 16TH AVE S Unit C Parcel Number: 250090 0050 Project Description: Installation of(2)internally illuminated wall signs. Includes electrical connection to existing J-Boxes. Owner Applicant Contractor VERIZON WIRELESS INSIGNIA SIGN INC(GENERAL) INSIGNIA SIGN INC(GENERAL) 34512 16TH AVE S PO BOX 2849 INSIGSI062QZ (2/19/12) FEDERAL WAY WA 98003 RENTON WA 98056 PO BOX 2849 RENTON WA 98056 za.:. tea' .... � ... • • Comprehensive Plan Designation Commercial Zoning Designation CE Enterprise PERMIT EXPIRES Tuesday, July 3, 2012 Permit Issued on Thursday, January 5, 2012 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington a. the Ci - ay. Owner or agent: t.1.1.�� —" ` Date: d Iph5 � l THIS CARD IS T MAIN ON-SITE CITY OF Construction In ection Record ' 1 Federal Way INSPECTION REQUE TS: (253)835-3050 PERMIT#: 11-105041-00-SG Address: 34512 16TH AVE S Unit C Project: VERIZON WIRELESS FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Footings/Setback(4110) ❑ Final-Electrical(4055) 0 Final-Sign (4085) Approved to place concrete Approved Approved By Date By V Date .3 _ qs,, ? .By -,, �� Date 3..a t 12 I Attachment(4010) Approved By L lam_ Date '- _, g_1 • El Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date , VeSi ._ it. . J. . Cole -- IDSA( CITY OF _ \\ SIGN PERMIT To Federa a��� ' °`ca 4.I CATI O N ///c / //c2 — • PROPERTY INFORMATION SITE ADDRESS 34512 16th Ave South SUITE/UNIT# ASSESSOR'S TAX/PARCEL# 25500900050 - _ _ _ _ ZONING DESIGNATION CE • PROJECT INFORMATION TYPE OF PROJECT(Check all that apply):XPERMANENT ❑TEMPORARY XNEW ❑ALTERATION ❑REFACE ❑EXEMPT XELECTRICAL(To attach to existing J-box-include on this permit) ❑ ELECTRICAL(New/altered circuit&J-box added- separate permit is required) NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: Wail Mounted: 2 Freestanding: TOTAL ESTIMATED PROJECT COST: $ 1,500.00 DETAILED PROJECT DESCRIPTION: Install & wire 2 new wall signs to existing circuits: BUSINESS NAME ON SIGN: Verizon Wireless • PEOPLE INFORMATION SIGN OWNER: NAME PRIMARY PHONE Fedway Marketplace West ( ) - MAILING ADDRESS(STREET ADDRESS:CITY.STATE.ZIP): FAX NUMBER 34512 16th Ave South ( ) - CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: E-MAIL ADDRESS CONTRACTOR: COMPANY NAME APPLICANT NAME OFFICE PHONE Insignia Sign Inc. Steven Thomson (425) 917 - 2109 MAILING ADDRESS(STREET ADDRESS:CITY.STATE-ZIP): CELL PHONE PO BOX 2849, Renton WA 98056 ( ) - CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: EXPIRATION DATE: FAX NUMBER (425) 917 - 0153 CONTRACTORS REGISTRATION NUMBER EXPIRATION DATE: E-MAIL ADDRESS INSIGS1062QZ 02/2012 Steven@insigniasign.com APPLICANT COMPANY NAME APPLICANT NAME PRIMARY PHONE (425) 917 - 2109 MAIUNG ADD RESS CITY,STATE,ZIP FAX NUMBER PO BOX 2849 Renton WA 98056 (425) 917 -0153 RELATIONSHIP TO PROJECT EMAIL ADDRESS X Contractor ❑Tenant ❑ Other Steven@insigniasign.com PROJECT NAME PRIMARY PHONE EMAIL ADDRESS: CONTACT Steven Thomson (425) 917 - 2109 Steven@insigniasign.com ■ SIGNATURE I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and further, that I am authorized by theownerof the above premises to perform the work for which the permit application is made SIGNATURE Steven R. V pvmbvtti DATE: 12/21/2011 COMMUNITY DEVELOPMENT SERVICES•33325 8R+AVENUE SOUTH•PO BOX 9718•FEDERAL WAY.WA 98063-9718•253-835-2607•FAX:253.835.2609 • MPORARY SIGN APPLICATIONS Oi 1** TYPE/PURPOSE OF EVENT: DATE OF INSTALLATION: DATE OF REMOVAL: TOTAL CALENDAR DAYS: DESCRIPTION OF PROPOSED SIGNAGE: • TYPE OF SIGN(S) (Indicate number of each) PERMANENT FREE STANDING: MONUMENT PEDESTAL POLE TENANT DIRECTORY OTHER OTHER(Describe) PERMANENT BUILDING MOUNTED: AWNING CABINET CHANNEL LETTERS 2 (raceway mounted) OTHER(Describe) • DETAILED SIGN INFORMATION FREESTANDING SIGNS SIGN TYPE SIGN AREA(SQ.FT.) ILLUMINATED? REFACE? TOTAL HEIGHT BASE HEIGHT(FT) WIDTH x HEIGHT x#OF FACES NO/INT/EXT YES/NO (FT) A _ x x = B x x - C x x = STREET FRONTAGE(LINEAR FEET): -155'x168' BUILDING MOUNTED SIGNS SIGN TYPE i SIGN AREA(SQ.FT.) ILLUMINATED? BUILDING ELEVATION EXPOSED BUILDING FACE WIDTH x HEIGHT x#OF FACES NO/INT/EXi (N,S,E,W) (SQ.FT.) OChannel Letters (racexnty mouMee, 12rg rrx2'9-7/8 x 1 = 36 Internal West Oi ICh"�annel°`"=yLetters 67\ > 12'9"x2'9-7/8"x 1 — 36 Internal East TV x x D _ x x - ciE x x = LARGEST EXPOSED BUILDING FACE(SQUARE FEET): **FOR OFFICE USE ONLY** ZONING DESIGNATION: PR . 0 HIGH 0 MEDIUM ❑ LOW 0 FREEWAY BUILDING/ gM NTED SIGN(S) FREE STANDING SIGN(S) AREA PERMITTED: `Q 1 l AREA PERMITTED: AREA PROPOSED: 31e _ 3 (a AREA PROPOSED: LARGEST BUILDING FACADE: / STREET FRONTAGE: NUMBER OF SIGNS ALLOWE I • / NUMBER 0 GNS ALLOWED: LAND USE APPROVAL BY: AiTt DATE: 1,Z ( STRUCTURAL APPROVAL BY: S/S DATE: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: • 4\111.1.1.11.111° 1111 SIGN PROJECT /11/SI/G/V/ ....Re–/ PHYSICAL ADDRE_ verl72n wirel ess 325 Burnett Ave North Renton, WA 98057 ill MAILING ADDR PO BOX 2849 «iIR I lilt a t .., L. Renton, WA 9805 r Walmart 1 - OFFICE: (425) 917-2109 1 , ---...y, Save money.Live better. '... B - .r,. ��`�� FAX: (425) 917-2109 • GC LICENSE: INSIGS1062QZ ,s l 4 6 ii ii ..� ..-r.w _ - - ._•e `,;: r ------ .--- ...-.�,.-- s_. - ti ELEC LICENSE: INSIGSI055JS - 1 ---, I - CUSTOMER: i , i ,- .. t•`. i .' \I ~ ----' a wireless 1 Game , Sprint ,�; '1A/INE 1 vena r 1 Stop i / 7 di-- — _ �, — - 13 ver/ nwireless I( RoundTable . 441 ' ' _ . ; >,_ - -- -_ ` ; IMAGEWOl -I ? t �� ) ._.,� ..._ �,..,, s •.--:- _„- r »_._ 11046 LEADBETTER ROAD ASHLAND .t ... 3_.. ..:..-A/' n -� .'_ e. ._.'-' .... .-,. - PHONE 804.7985533 FAX 804.7912 I , i f : -11..• 1 fr i - - , _ Page: 1 orn I, , l • 4 y .{ 4 , t �_ — - �. , ., :. 1 \ PROJECT ADDRESS: + ! 1 - —i --�. , 34512 16th Ave South A.I —__i�� --� t iM 1 �'� (Suite C) 11 iL 4 1 I # 1 ` j '�----- i it . . T ce Federal Way, WA 98003 ' • 'NIl ! '; ' DATE: 12/21 � D i J a 0 t i t r } t Iy t I D rn `-_'y' I _._.`� rw^-r�.r' \ m 0 • iis ! I. + Contact: Steven Thi e' .;, —4 , _in vi L t Steven@insigniasig ' ) g _ y,• . iiIII ifil * 0 r NQ "Pacel #250090i -I 1 . i nelbri ., •.... --- '.. ' , W ISI Job #11-49. J ,ivi Zone: CE FD� FDs ' '+' This is an original design and drawing r— N co c� Imp • clusive use of the customer. Ur cmi, vC 0 1 = f i r V Il rights are reserved and it is or v' CQ a) : i by customer in connection with this pn D cn to be reproduced in any manner w ve SITE AERIAL VIEW: � �� exprucswrorpemiiten ring ofInsignia (� c ` O F Construction or di pemiitting conditionsspcit j f FEDERAL w nth in dimensions s,specific o the printing process,colors CDS Cr,I 4 . _ (Aril /Afar RAFfni pas 7/1 ffirfi) e ' _ I AL) .. PHYSICAL ADDRESS: N325 Burnett Ave North 4 1 _ .0. ........ ..., .1.74,... Renton, WA 98057 . t,.kr. MAILING ADDRESS: _ J IP to, [- 1, R 4 PO BOX 2849 'AtRenton, WA 98056 / IF . • •8. OFFICE: (425) 917-2109 ,, FAX: (425) 917-2109 fi GC LICENSE: INSIGSI062Q2 ' 1 I r ELEC LICENSE: INSIGSI055JS .. ..,,:.. ,W, r g TE A&B a I CUSTOMER: .* WINE a /r la ,� v@riZon wireless .•...,_ . PAW - P . II '1 ,� Gamesro��irj cu IMAGEWORKS 11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005 . PHONE 804.798.5533 FAX 804.798.5582 �� �— " t._ A Page: 2 OF 4 A r� i ►�. V@ 011Uwi Bless ' �'k '` " PROJECT ADDRESS: L ! 52' i _ 34512 16th Ave South iit- J I r. . B (Suite C) I ' .._.__. Federal Way, WA 98003 ° - i F. - 1 rWITED d a DATE: 12/21/11 , ... I Stop IN Contact: Steven Thomson Liu —lift' Steven@insigniasign.com Parcel #250090-0050 ..eAt, I I . I 151 Job #11-4994 �1 .' Ill Ili Zone: CE i �-- __ - a air NW ' ;a ♦ This is an original design and drawing created for the exclusive use of the customer. Until transfer by SIGN LEGEND sale,all rights are reserved and it is only to be used by customer in connection with this project. It is not to be reproduced in any manner without the express written approval of Insignia Sign, Inc. veriZn SITE PLAN • A = Wa I I Sign B = Wa I I Sign Construction or permitting conditions may cause a ( Page 3 ) ( Page 4 ) change in dimensions or specifications. Due to the printing process,colors may vary. ° • • . . 0 Concrete Hardy Board 12'-9" AVE CAREFULLY REVIEWED AND HEREBY ACCEPT 5" 8" THE DRAWING(S)AS SHOWN.I REALIZE THAT ANY CHANGES TO THESE DESIGNS MADE BEFORE OR AFTER PRODUCTION MAY ALTER THE CONTRACT PRICE.ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION. ❑ 3/8"all-thread \ ILi ?iS — waac sher on bk IV/JIiiA a (4-5 total) rd Pile. .,_ ® -- SIGNATURE&DATE THE CUSTOM ARTWORK DEPICTED HEREIN IS FOR REPRESENTATIONAL PURPOSES ONLY N - .111111 AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. ELECTRIC SIGNS PRODUCED AT Go1/2IR€L.€SS PremiumRetailer, IMAGE WORKS CONFORM TO UL 48 'JALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS. 1/2"BLACK PVC F.C.O.LETTERS AND DIVIDER,MOUNT FLUSH TO 10'-5 3/4" FABRICATED ALUMINUM PAN SIGN 2" DATE REVISION DESCRIPTION DESIGNER INTERNALLY ILLUMINATED CHANNEL LETTERS ON A RACEWAY 36 SQ. FT. END VIEW (1)OF(2)SETS REQUIRED LETTER CONSTRUCTION REQUIREMENTS FOR ELECTRICAL ILLUMINATION BACKS: .040"WHITE/WHITE ALUMINUM PRIMARY ELECTRICAL LOCATION IS PROVIDED COLOR KEY BAFFLE:N/A BY OTHERS.A DEDICATED CIRCUIT WITH NO SHARED RETURNS:5"DEEP, .040"ALUMINUM BLACK NEUTRALS AND A GROUND RETURNING TO THE PANEL ACRYLIC TRIM CAP:3/4"BLACK IS REQUIRED FOR ALL INSTALLATIONS 278-0 RED RETAINER: N/A REQUIRED BY UL STANDARD#2161 AND IMAGE WORKS, SELF-CONTAINED: N/A ALL TRANSFORMERS SHALL BE(GFI)GROUND REMOTE: NO FAULT INTERRUPTED TRANSFORMERS PAINT RACEWAY:YES ALL SIGNS HAVE: -DEDICATED BRANCH CIRCUITS ■ SATIN FINISH BLACK FACE DETAILS -THREE WIRES:LINE,NEUTRAL&GROUND PLEX: -WIRE SIZE:MINIMUM 12 GAUGE THN COPPER SW 2446 EDELWEISS 3/16"WHITE#2447 ALSO NOTE;GAUGE OF COPPER IS DETERMINED BY THE 3/16"RED#278-0'Z' LENGTH OF RUN&AMPERAGE AS PER NEC ARTICLE 300. LEXAN: N/A -GROUND WIRE MUST BE CONTINUOUS AND GO FROM ^ 11 THE SIGN TO THE PANEL BOARD GROUND BUS 9 (6% ILLUMINATION -VOLTAGE SHOULD READ NO MORE THAN(3)VOLTS LED:WHITE BETWEEN GROUND AND NEUTRAL Ele) F .-- — RED 'Z' -CONDUIT CAN NOT BE USED AS A GROUND PATH. /�, NEON: N/A 5 4 VOLTAGE: 120V /V 1' r IMAGEWORKS ; 11046 LEADBETTER ROAD ASHLAND,VA 23005 PHONE:804.798.5533 FAX:804.798.5582 NIMINIMMENEMEMIMI 111.11111.111.11111111.1110 '- 1AGM A .r e,c ( w�Ra..r� GO WIRELESS CLIENT I I 4 '. FEDERAL WAY,WA .,. LOCATION.- . JIM NEIL --- SALES REPRESENTATIVE WAM . ...: Y .1,' t.I r DESIGNER LIQUOR f - 10.24.11 - DATE PREPARED Oil LIQUOR r t, t — WINE .. WINE7'-. ,. 4-JRi-,- ..:*W - .6 lit .. .,,,,,,R, _,,,, SCALE "' GOWIRELESS-FEDERALWAY-01 • y, PROJECT ID t T' . ., CL 1 OPT DRAWING IDENTIFICATION EXISTING CONDITIONS PHOTO SHOWS PROPOSED SIGNAGE.NOT TO SCALE. (CENTERED ON WALL) • S r • • • • Block WallIII ' 12'-9" I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT 5" 1_, 8„ THE DRAWING(S)AS SHOWN.I REALIZE THAT ANY CHANGES TO THESE DESIGNS MADE BEFORE OR • AFTER PRODUCTION MAY ALTER THE CONTRACT a I❑ PRICE.ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION. I d rib-(as tow) (n L Co 1 pj / , Li) ❑ �10So ilyitio � bo ■ j i_ .ipc,... SIGNATURE&DATE 7 THE CUSTOM ARTWORK DEPICTED HEREIN IS rn FOR REPRESENTATIONAL PURPOSES ONLY iN }-,_- � '■ AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. ELECTRIC SIGNS PRODUCED AT IMAGE WORKS CONFORM TO UL 48 00*IRELdESS Premium Retaile 1/2" 'bolts�atotal)a STANDARDS UNDERWRITERS LABORATORIES LABEL. ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS. 1/2"BLACK PVC F.C.O.LETTERS !— - AND DIVIDER,MOUNT FLUSH TO 10'-5 3/4" FABRICATED ALUMINUM PAN SIGN 2" DATE REVISION DESCRIPTION DESIGNER INTERNALLY ILLUMINATED CHANNEL LETTERS ON A RACEWAY 36 SQ. FT. END VIEW (2)OF(2)SETS REQUIRED LETTER CONSTRUCTION REQUIREMENTS FOR ELECTRICAL ILLUMINATION BACKS: .040"WHITE/WHITE ALUMINUM PRIMARY ELECTRICAL LOCATION IS PROVIDED COLOR KEY BAFFLE: N/A BY OTHERS.A DEDICATED CIRCUIT WITH NO SHARED fi RETURNS:5"DEEP, .040"ALUMINUM BLACK NEUTRALS AND A GROUND RETURNING TO THE PANEL n�r ACRYLIC TRIM CAP:3/4"BLACK IS REQUIRED FOR ALL INSTALLATIONS E6 94 278-0 RED RETAINER:N/A REQUIRED BY UL STANDARD#2161 AND IMAGE WORKS, °/ g g SELF-CONTAINED: N/A ALL TRANSFORMERS SHALL BE(Gi=1)GROUND /144-1 ,� /_ REMOTE:NO FAULT INTERRUPTED TRANSFORMERS j /1 4 1 (sJ PAINT RACEWAY:YES ALL SIGNS HAVE: -DEDICATED BRANCH CIRCUITS S P 1 , 3 ff . SATIN FINISH BLACK FACE DETAILS -THREE WIRES:LINE,NEUTRAL&GROUND - - - PLEX: -WIRE SIZE:MINIMUM 12 GAUGE THN COPPER SW 2446 EDELWEISS 3/16"WHITE#2447 ALSO NOTE;GAUGE OF COPPER IS DETERMINED BY THE 3/16"RED#278-0 'Z' LENGTH OF RUN&AMPERAGE AS PER NEC ARTICLE 300. LEXAN: N/A -GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANEL BOARD GROUND BUS ILLUMINATION -VOLTAGE SHOULD READ NO MORE THAN(3)VOLTS LED:WHITE BETWEEN GROUND AND NEUTRAL RED 'Z' -CONDUIT CAN NOT BE USED AS A GROUND PATH. NEON: N/A VOLTAGE: 120V 25'0" 11-1117 j . •, Game 18' I' p IMAGEWORKS Stop _ I i Stop 1 r `y A".1.6' # Vgr1LOhWiCetPS 'r w.S . 11046 LEADBE TTER ROAD ASHLAND,V-A 2-3 0 —05 PHONE:804.798.5533 FAX 804798.5582 io C t •.* IMX11 GOVIRE ss� tR.rar .f. .,.,.,/p.., , , : y , ; ,,.,0 GO WIRELESS - CLIENT VA FEDERAL WAY,WA i LOCATION . ' :,� JIM NEIL ile: _ - SALES REPRESENTATIVE 11 a ! WAM +t j _: :., t - : i DESIGNER p , . . . . . _ 10.24.11 t• . _, . , DATE PREPARED SCALE �.� GOWIRELESS-FEDERALWAY-01 i f PRDIECT ID '!" CL 2 OPT DRAWING IDENTIFICATION EXISTING CONDITIONS PHOTO SHOWS PROPOSED SIGNAGE.NOT TO SCALE. (CENTERED ABOVE CANOPY)