20-100856 • Building - Single Family
City of Federal Way Permit #:20-100856-00-SF
Community Development Dept.
33325 8th Ave S
Federal Way,WA 98003 Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax:(253)835-2609
Project Name: DEHAN
Project Address: 29845 11TH AVE SW Parcel Number: 195460 0085
Project Description: Underpinning of existing single family residence to stabilize the foundation.No change in
footprint.
Owner Applicant Contractor Lender
MARK DEHAN AYDEN WAGNERMATVEY MATVEY FOUNDATION REPAIR OWNER IS LENDER
298451 ITH AVE SW FOUNDATION REPAIR INC
FEDERAL WAY WA 98023 1912 S 146TH ST 1912 S 146TH ST
SEATAC WA 98168 SEATAC WA 98168
Census Category: 434-Residential alt/add-no change in number of units
Includes: #1 #2 #3 #4
Occupancy Class:
Construction Type:
Occupancy Load:
Floor Area(sq.ft.)
Additional Permit Information
Mechanical to be Included? No Number of Stories 1
Is this an Online or O.T.C.applications No Plumbing to be Included No
Total Valuation: 13,000.00
CONDITIONS:
Subject to field inspection with plans.
PERMIT EXPIRES Monday,24 August,2020
Permit Issued on Wednesday,February 26,2020
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: Date: 21. -'%v I go
se,/I,'
THIS CARD IS TO REMAIN ON-SITE
ciry
Federal Way Construction Inspection Record
INSPECTION REQUESTS:(253)835-3050
PERMIT#: 20 100856 00 Address: 29845 11TH AVE SW
Project: MARK J DEHAN FEDERAL WAY WA 980234210
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
® Footings/Setback(4110) ® Final-Building(4050)
Approved to place concrete I Approved
I
By Date By WDate ,S'' 20 G
El Rough Electrical 0 Final ElectricalE3 Right of Way
Approved Approved Approved
By Date By Date •
• By Date
Technology Associates
Special Inspection
FINAL SUMMARY REPORT
March 4, 2020
City of Federal Way
Permit Center
33325 8th Ave S.
Federal Way, WA 98003
RE: Project Name: Dehan Residence Foundation Repair
Permit No: 20-100856-00-SF
Address: 29845 11th Ave SW, Federal Way,WA
Dear Permit Center,
This letter serves to certify that in accordance with Chapter 17 of the International Building Code
requirements outlines in the General Structural Notes of S-1.00 of the approved permit drawings,
Technology Associates EC, Inc. has performed special inspection as detailed below.
The inspector observed the installation of(9)FSI 288 push pier,verifying pier locations, installation depth,
installation pressure, bracket type, pier type, pier diameter and thickness. To confirm pier capacity, loads
were observed following installation and the results were within approved allowances. Please see the
attached field installation logs and load test data dated, 3/3/2020. All piers were installed per the intent
of the design drawings and any installation deviations were reviewed and approved by this office with no
outstanding non-compliance items.
Our inspection and testing services do not constitute a warranty or guarantee of any type and were
provided and intended to help reduce the risk of construction defects, deficiencies or omission that may
arise during and after construction. It is the contractor's responsibility to perform their work in accordance
with approved construction documents. All inspections and tests were performed and reported according
to the requirements of the City of Federal Way and,to the best of my knowledge,the work was in
conformance with the applicable workmanship provisions of the Washington State Building Code and
Standards.
Sincer
3/4/20
Peter L neer
Cc: Olga Ticot-Matvey Foundation Repair
650 South Orcas Street, Suite R-103
Seattle, WA 98108
www.taec.net
Technology" tAssociates FIELD INSTALLATION LOG
650 South Orcas St.#R-103
Seattle,WA 98108
(206)713-9915
Proj.Name: DeHan Residence Contractor: Matvey
Site Address: 29845 11th Ave SW,Federal Way,WA Proj.Foreman:Josiah
Permit No.: 20-100856-00-SF Install Date: 3/3/2020
Jurisdiction: City of Federal Way Inspector Name:Pete Ludnquist
Contr.Arrival: Inspector Arrival:
Pier Wall Pier Segment Installation
Location Part Description Pier OD,in Thickness,in Length,in Pressure,psi
P1 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 3000
Pipe Extension 2.875" 0.165" 36" 2500
Pipe Extension 2.875" 0.165" 36" 2100
Pipe Extension 2.875" 0.165" 36" 4000
12'0"
P2 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 3800
Pipe Extension 2.875" 0.165" 36" 2500
Pipe Extension 2.875" 0.165" 36" 2200
Pipe Extension 2.875" 0.165" 36" 4000
12'0"
P3 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2800
Pipe Extension 2.875" 0.165" 36" 3100
Pipe Extension 2.875" 0.165" 36" 2200
Pipe Extension 2.875" 0.165" 36" 3000
Pipe Extension 2.875" 0.165" 18" 4000
13'6"
Non-Compliance Items:
Inspectors Signature:
Technology it Associates FIELD INSTALLATION LOG
650 South Orcas St.8R-103
Seattle,WA 98108
(206)713-9915
Proj.Name: DeHan Residence Contractor: Matvey
Site Address: 29845 11th Ave SW, Federal Way,WA Proj.Foreman:Josiah
Permit No.: 20-100856-00-SF Install Date: 3/3/2020
Jurisdiction: City of Federal Way Inspector Name: Pete Ludnquist
Contr.Arrival: Inspector Arrival:
Pier Wall Pier Segment Installation
Location Part Description Pier OD,in Thickness,in Length,in Pressure,psi
P4 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2000
Pipe Extension 2.875" 0.165" 36" 2100
Pipe Extension 2.875" 0.165" 36" 3000
P5 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 4000
3'0"
P6 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 800
Pipe Extension 2.875" 0.165" 36" 1800
Pipe Extension 2.875" 0.165" 36" 3000
9'0"
Non-Compliance Items:
Inspectors Signature:
Technology4Associates FIELD INSTALLATION LOG
650 South Orals St.#R-103
Seattle,WA 98108
(206)713-9915
Proj.Name: DeHan Residence Contractor: Matvey
Site Address: 29845 11th Ave SW, Federal Way,WA Proj.Foreman:Josiah
Permit No.: 20-100856-00-SF Install Date: 3/3/2020
Jurisdiction: City of Federal Way Inspector Name: Pete Ludnquist
Contr.Arrival: Inspector Arrival:
Pier Wall Pier Segment Installation
Location Part Description Pier OD,in
Thickness,in Length,in Pressure,psi
P7 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 1000
Pipe Extension 2.875" 0.165" 36" 2200
Pipe Extension 2.875" 0.165" 36" 3000
9.-0..
P8 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2100
Pipe Extension 2.875" 0.165" 36" 2000
Pipe Extension 2.875" 0.165" 36" 3000
9.-0"
P9 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2100
Pipe Extension 2.875" 0.165" 36" 2800
Pipe Extension 2.875" 0.165" 36" 2000
Pipe Extension 2.875" 0.165" 36" 2000
Pipe Extension 2.875" 0.165" 36" 3800
15'0"
Non-Compliance Items:
Inspectors Signature:
Technology it Associates LOAD TEST LOG
650 South Orcas St 911-103
Seattle,WA 98108
(206)713-9915
Proj.Name: DeHan Residence Contractor: Matvey
Site Address: 29845 11th Ave SW, Federal Way, WA Proj.Foreman:Josiah
Permit No.: 20-100856-00-SF Test Date 3/3/2020
Jurisdiction: City of Federal Way Inspector Name: Pete Lundquist
Pier Test P2 Test Pressure,psi: 1800
Working Load,Kips: 8.2 max Test Load,kips: 17.316
Total Creep,in: 0.0"
dial started
0 min: or n o� 4 min: 15 min: 40 min:
0.
1 min: 5 min: 20 min: 50 min:
2 min: at 0.086 6 min: at 0.086 30 min: 60 min:
3 min: 10 min: at0.086
Pier Test P9 Test Pressure,psi: 1800
Working Load,Kips: 8.2 max Test Load,kips: 17.316
Total Creep,in: 0.0"
dial started
0 min: 4 min: 15 min: 40 min:
at 0.080
1 min: 5 min: at 0.080 20 min: 50 min:
2 min: at 0.080 6 min: 30 min: 60 min:
3 min: 10 min: at0.080
Continuous special inspection is required during the installation per 2015 IBC section 1810.4.12.Load testing shall be performed in accordance
with ASTM Method D1143(Quick Method).20 percent of piers shall be tested to 150 percent design load. Load testing creep acceptance criteria
shall be no greater than 0.04 inches within a 10 minute period. If movement is observed greater than 0.04 inches within the 10 minute period the
load test shall be held for an additional 50 minutes,the pier is to be deepened and re-tested,or the pier is to be abandoned and replace with a
new pier. If the load test is to be held the pier movements shall be measure at 15,20,30,40,50,and 60 minutes. The creep versus the logarithm
of time shall be plotted. If the creep rate is less then 0.080 inches between 6 and 60 minutes,the load test shall be considered successful.
Non-Compliance Items: Note:Load test performed utilizes a hydralic
load cylinder with an effective bore diameter
of 3.5"which equates to an operating
hydraulic area of 9.62 int'Pier Test Pressure
(psi)=[Design Load]X 1.5/9.62in2
Inspectors Signature:
RECEIVED
,,, PERMIT APPLICATION
CITY OF
FEB 2 l 2020 PERMIT CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325
Federal Way 253-835-2607+FAX 253-835-2609+permitcenter@cityoffederalway.com
CITY COMMUNITY DEVELOPMENT
PERMIT NUMBER V _ k V D g 5 _ S N/
TARGET DATE
SITE ADDRESS SUITE/UNIT#
29845 11th Ave SW, Federal Way, WA 98023
PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL#
$ 13,000 1 9 5 4 6 0 _ 0 0 8 5
TYPE OF PERMIT (BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT DeHan Residence Foundation Repair
PROJECT DESCRIPTION Underpinning of existing single family residence to stabilize the foundation.
Detailed description of work to No change in footprint.
be included on this permit only
NAME PRIMARY PHONE
Mark DeHan (206) 300-1932
PROPERTY OWNER MAILING ADDRESS E-MAIL
29845 11th Ave SW mjdehantc'i,yahoo.com
CITY STATE ZIP
Federal Way WA 98023
NAME PHONE
Matvey Foundation Repair 253-327-1650
MAILING ADDRESS E-MAIL
CONTRACTOR 1912 S 146th St permits@gomatvey.com
CITY STATE ZIP FAX
SeaTac WA 98168
WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE#
Matvefr837k5 06/ 15 / 20 20-17-101757-00-BL
NAME PRIMARY PHONE
Ayden Wagner 206-660-7971
APPLICANT MAILING ADDRESS E-MAIL
1912 S 146th St permits@gomatvey.com
CITY STATE ZIP FAX
SeaTac WA 98023
NAME PRIMARY PHONE
PROJECT CONTACT Ayden Wagner 206-660-7971
(The individual to receive and MAILING ADDRESS EMAIL
respond to all correspondence 1912 S 146th St permits@gomatvey.com
concerning this application) CITY STATE ZIP FAX
SeaTac WA 98023
NAME
PROJECT FINANCING N/a ❑ OWNER-FINANCED
When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RCW 19.27.095)
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses,and attorneys'fees incurred in
the investigation and defense of such claim), which may be made by any person,including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a part of this application.
Air
SIGNATURE: , 1_1 � DATE
alab (a�a�
PRINT NAME: bi,�e \ U3✓ or
Bulletin#100—January 29,2016 Page 1 of 2 k:\Handouts\Permit Application
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT $
Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe)
AIR CONDITIONER FIREPLACE INSERTS HOODS(comrocrclai)
BOILERS FURNACES HOT WATER TANKS(cas
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
DUCTING GAS PIPING WOODSTOVES
VALUE OF PLUMBING WORK
PLUMBING PERMIT $
Indicate how many of each type offucture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
BATHTUBS(or Tub/Shower Combo) LAVS(Hand Sinks) TOILETS WATER PIPING
DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
DRAINS SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS SINKS(Kitchen/Utility) WATER HEATERS(stectrio)
HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
No $
EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM?
❑Yes ❑ No ❑Yes ❑ No
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
,13,A,„.§/E.----:./7:s.,:, /, ',i X00
FIRST FLOOR(or Mobile Home)
SECOND FLOOR f ���tr �f�
COVERED ENTRY
GARAGE 0 CARPORT ❑
>rfr/; red
OTHER escrib f/%
EXISTING PROPOSED TOTAL
Area Totals
4 **NEW HOMES ONLY** /61,P- i
ESTIMATED SELLING PRICE$ # OF BEDROOMS
COMMERCIAL—NEW/ADDITION
AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information
Square Feet Type Stories
*ii,,,BUILDING 5'" 44.1.,' ,ri'y it
ADDITION
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information
Square Feet Type Stories
TOTAL BUILDING 4 /./,0,
/ �/
TENANT AREA ONLY
'''PROJECT AREA ONLY
i„ rr. ryy
Bulletin#100—January 29,2016 Page 2 of 2 k:\Handouts\Permit Application