Loading...
20-100856 • Building - Single Family City of Federal Way Permit #:20-100856-00-SF Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: DEHAN Project Address: 29845 11TH AVE SW Parcel Number: 195460 0085 Project Description: Underpinning of existing single family residence to stabilize the foundation.No change in footprint. Owner Applicant Contractor Lender MARK DEHAN AYDEN WAGNERMATVEY MATVEY FOUNDATION REPAIR OWNER IS LENDER 298451 ITH AVE SW FOUNDATION REPAIR INC FEDERAL WAY WA 98023 1912 S 146TH ST 1912 S 146TH ST SEATAC WA 98168 SEATAC WA 98168 Census Category: 434-Residential alt/add-no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area(sq.ft.) Additional Permit Information Mechanical to be Included? No Number of Stories 1 Is this an Online or O.T.C.applications No Plumbing to be Included No Total Valuation: 13,000.00 CONDITIONS: Subject to field inspection with plans. PERMIT EXPIRES Monday,24 August,2020 Permit Issued on Wednesday,February 26,2020 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: 21. -'%v I go se,/I,' THIS CARD IS TO REMAIN ON-SITE ciry Federal Way Construction Inspection Record INSPECTION REQUESTS:(253)835-3050 PERMIT#: 20 100856 00 Address: 29845 11TH AVE SW Project: MARK J DEHAN FEDERAL WAY WA 980234210 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ® Footings/Setback(4110) ® Final-Building(4050) Approved to place concrete I Approved I By Date By WDate ,S'' 20 G El Rough Electrical 0 Final ElectricalE3 Right of Way Approved Approved Approved By Date By Date • • By Date Technology Associates Special Inspection FINAL SUMMARY REPORT March 4, 2020 City of Federal Way Permit Center 33325 8th Ave S. Federal Way, WA 98003 RE: Project Name: Dehan Residence Foundation Repair Permit No: 20-100856-00-SF Address: 29845 11th Ave SW, Federal Way,WA Dear Permit Center, This letter serves to certify that in accordance with Chapter 17 of the International Building Code requirements outlines in the General Structural Notes of S-1.00 of the approved permit drawings, Technology Associates EC, Inc. has performed special inspection as detailed below. The inspector observed the installation of(9)FSI 288 push pier,verifying pier locations, installation depth, installation pressure, bracket type, pier type, pier diameter and thickness. To confirm pier capacity, loads were observed following installation and the results were within approved allowances. Please see the attached field installation logs and load test data dated, 3/3/2020. All piers were installed per the intent of the design drawings and any installation deviations were reviewed and approved by this office with no outstanding non-compliance items. Our inspection and testing services do not constitute a warranty or guarantee of any type and were provided and intended to help reduce the risk of construction defects, deficiencies or omission that may arise during and after construction. It is the contractor's responsibility to perform their work in accordance with approved construction documents. All inspections and tests were performed and reported according to the requirements of the City of Federal Way and,to the best of my knowledge,the work was in conformance with the applicable workmanship provisions of the Washington State Building Code and Standards. Sincer 3/4/20 Peter L neer Cc: Olga Ticot-Matvey Foundation Repair 650 South Orcas Street, Suite R-103 Seattle, WA 98108 www.taec.net Technology" tAssociates FIELD INSTALLATION LOG 650 South Orcas St.#R-103 Seattle,WA 98108 (206)713-9915 Proj.Name: DeHan Residence Contractor: Matvey Site Address: 29845 11th Ave SW,Federal Way,WA Proj.Foreman:Josiah Permit No.: 20-100856-00-SF Install Date: 3/3/2020 Jurisdiction: City of Federal Way Inspector Name:Pete Ludnquist Contr.Arrival: Inspector Arrival: Pier Wall Pier Segment Installation Location Part Description Pier OD,in Thickness,in Length,in Pressure,psi P1 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 3000 Pipe Extension 2.875" 0.165" 36" 2500 Pipe Extension 2.875" 0.165" 36" 2100 Pipe Extension 2.875" 0.165" 36" 4000 12'0" P2 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 3800 Pipe Extension 2.875" 0.165" 36" 2500 Pipe Extension 2.875" 0.165" 36" 2200 Pipe Extension 2.875" 0.165" 36" 4000 12'0" P3 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2800 Pipe Extension 2.875" 0.165" 36" 3100 Pipe Extension 2.875" 0.165" 36" 2200 Pipe Extension 2.875" 0.165" 36" 3000 Pipe Extension 2.875" 0.165" 18" 4000 13'6" Non-Compliance Items: Inspectors Signature: Technology it Associates FIELD INSTALLATION LOG 650 South Orcas St.8R-103 Seattle,WA 98108 (206)713-9915 Proj.Name: DeHan Residence Contractor: Matvey Site Address: 29845 11th Ave SW, Federal Way,WA Proj.Foreman:Josiah Permit No.: 20-100856-00-SF Install Date: 3/3/2020 Jurisdiction: City of Federal Way Inspector Name: Pete Ludnquist Contr.Arrival: Inspector Arrival: Pier Wall Pier Segment Installation Location Part Description Pier OD,in Thickness,in Length,in Pressure,psi P4 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2000 Pipe Extension 2.875" 0.165" 36" 2100 Pipe Extension 2.875" 0.165" 36" 3000 P5 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 4000 3'0" P6 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 800 Pipe Extension 2.875" 0.165" 36" 1800 Pipe Extension 2.875" 0.165" 36" 3000 9'0" Non-Compliance Items: Inspectors Signature: Technology4Associates FIELD INSTALLATION LOG 650 South Orals St.#R-103 Seattle,WA 98108 (206)713-9915 Proj.Name: DeHan Residence Contractor: Matvey Site Address: 29845 11th Ave SW, Federal Way,WA Proj.Foreman:Josiah Permit No.: 20-100856-00-SF Install Date: 3/3/2020 Jurisdiction: City of Federal Way Inspector Name: Pete Ludnquist Contr.Arrival: Inspector Arrival: Pier Wall Pier Segment Installation Location Part Description Pier OD,in Thickness,in Length,in Pressure,psi P7 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 1000 Pipe Extension 2.875" 0.165" 36" 2200 Pipe Extension 2.875" 0.165" 36" 3000 9.-0.. P8 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2100 Pipe Extension 2.875" 0.165" 36" 2000 Pipe Extension 2.875" 0.165" 36" 3000 9.-0" P9 Sleeve&Starter Pipe 3.5"/2.875" .216"/.165" 30"/36" 2100 Pipe Extension 2.875" 0.165" 36" 2800 Pipe Extension 2.875" 0.165" 36" 2000 Pipe Extension 2.875" 0.165" 36" 2000 Pipe Extension 2.875" 0.165" 36" 3800 15'0" Non-Compliance Items: Inspectors Signature: Technology it Associates LOAD TEST LOG 650 South Orcas St 911-103 Seattle,WA 98108 (206)713-9915 Proj.Name: DeHan Residence Contractor: Matvey Site Address: 29845 11th Ave SW, Federal Way, WA Proj.Foreman:Josiah Permit No.: 20-100856-00-SF Test Date 3/3/2020 Jurisdiction: City of Federal Way Inspector Name: Pete Lundquist Pier Test P2 Test Pressure,psi: 1800 Working Load,Kips: 8.2 max Test Load,kips: 17.316 Total Creep,in: 0.0" dial started 0 min: or n o� 4 min: 15 min: 40 min: 0. 1 min: 5 min: 20 min: 50 min: 2 min: at 0.086 6 min: at 0.086 30 min: 60 min: 3 min: 10 min: at0.086 Pier Test P9 Test Pressure,psi: 1800 Working Load,Kips: 8.2 max Test Load,kips: 17.316 Total Creep,in: 0.0" dial started 0 min: 4 min: 15 min: 40 min: at 0.080 1 min: 5 min: at 0.080 20 min: 50 min: 2 min: at 0.080 6 min: 30 min: 60 min: 3 min: 10 min: at0.080 Continuous special inspection is required during the installation per 2015 IBC section 1810.4.12.Load testing shall be performed in accordance with ASTM Method D1143(Quick Method).20 percent of piers shall be tested to 150 percent design load. Load testing creep acceptance criteria shall be no greater than 0.04 inches within a 10 minute period. If movement is observed greater than 0.04 inches within the 10 minute period the load test shall be held for an additional 50 minutes,the pier is to be deepened and re-tested,or the pier is to be abandoned and replace with a new pier. If the load test is to be held the pier movements shall be measure at 15,20,30,40,50,and 60 minutes. The creep versus the logarithm of time shall be plotted. If the creep rate is less then 0.080 inches between 6 and 60 minutes,the load test shall be considered successful. Non-Compliance Items: Note:Load test performed utilizes a hydralic load cylinder with an effective bore diameter of 3.5"which equates to an operating hydraulic area of 9.62 int'Pier Test Pressure (psi)=[Design Load]X 1.5/9.62in2 Inspectors Signature: RECEIVED ,,, PERMIT APPLICATION CITY OF FEB 2 l 2020 PERMIT CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325 Federal Way 253-835-2607+FAX 253-835-2609+permitcenter@cityoffederalway.com CITY COMMUNITY DEVELOPMENT PERMIT NUMBER V _ k V D g 5 _ S N/ TARGET DATE SITE ADDRESS SUITE/UNIT# 29845 11th Ave SW, Federal Way, WA 98023 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ 13,000 1 9 5 4 6 0 _ 0 0 8 5 TYPE OF PERMIT (BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT DeHan Residence Foundation Repair PROJECT DESCRIPTION Underpinning of existing single family residence to stabilize the foundation. Detailed description of work to No change in footprint. be included on this permit only NAME PRIMARY PHONE Mark DeHan (206) 300-1932 PROPERTY OWNER MAILING ADDRESS E-MAIL 29845 11th Ave SW mjdehantc'i,yahoo.com CITY STATE ZIP Federal Way WA 98023 NAME PHONE Matvey Foundation Repair 253-327-1650 MAILING ADDRESS E-MAIL CONTRACTOR 1912 S 146th St permits@gomatvey.com CITY STATE ZIP FAX SeaTac WA 98168 WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# Matvefr837k5 06/ 15 / 20 20-17-101757-00-BL NAME PRIMARY PHONE Ayden Wagner 206-660-7971 APPLICANT MAILING ADDRESS E-MAIL 1912 S 146th St permits@gomatvey.com CITY STATE ZIP FAX SeaTac WA 98023 NAME PRIMARY PHONE PROJECT CONTACT Ayden Wagner 206-660-7971 (The individual to receive and MAILING ADDRESS EMAIL respond to all correspondence 1912 S 146th St permits@gomatvey.com concerning this application) CITY STATE ZIP FAX SeaTac WA 98023 NAME PROJECT FINANCING N/a ❑ OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses,and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person,including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. Air SIGNATURE: , 1_1 � DATE alab (a�a� PRINT NAME: bi,�e \ U3✓ or Bulletin#100—January 29,2016 Page 1 of 2 k:\Handouts\Permit Application VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS(comrocrclai) BOILERS FURNACES HOT WATER TANKS(cas COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT $ Indicate how many of each type offucture to be installed or relocated as part of this project.Do not include existing fixtures to remain. BATHTUBS(or Tub/Shower Combo) LAVS(Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS(Kitchen/Utility) WATER HEATERS(stectrio) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS No $ EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? ❑Yes ❑ No ❑Yes ❑ No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE ,13,A,„.§/E.----:./7:s.,:, /, ',i X00 FIRST FLOOR(or Mobile Home) SECOND FLOOR f ���tr �f� COVERED ENTRY GARAGE 0 CARPORT ❑ >rfr/; red OTHER escrib f/% EXISTING PROPOSED TOTAL Area Totals 4 **NEW HOMES ONLY** /61,P- i ESTIMATED SELLING PRICE$ # OF BEDROOMS COMMERCIAL—NEW/ADDITION AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet Type Stories *ii,,,BUILDING 5'" 44.1.,' ,ri'y it ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet Type Stories TOTAL BUILDING 4 /./,0, / �/ TENANT AREA ONLY '''PROJECT AREA ONLY i„ rr. ryy Bulletin#100—January 29,2016 Page 2 of 2 k:\Handouts\Permit Application