Loading...
06-105609 4 r 6! City of Federal Way Development Electrical Permit #: 06-105609-00-EL y velmen P.O.Boxop9718t Services Federal Way,WA 98063-9718 Ph:(253)835-2607 Fax (253)835-2609 Inspection Request Line: (253)835-3050 Project Name: FEDERAL WAY SELF STORAGE OFFICE Project Address: 35400 PACIFIC HWY S Parcel Number: 292104 9128 Project Description: Installation of low voltage electrical for door alarms,cctv and intercom systems. Owner Applicant Contractor J C STORAGE LLC ACCESS SYSTEMS PLUS LLC ACCESS SYSTEMS PLUS LLC 36809 204Th AVE SE PO BOX 820348 WOLLAJ*088DW 06/29/2009 AUBURN WA 98092 VANCOUVER WA 98682 PO BOX 820348 VANCOUVER WA 98682 Additional Permit Information Electrical Fixtures Low Voltage-Other Commercial.. 2,048 PERMIT EXPIRES Monday, April 30, 2007 Permit I aed ons •nesdty, November 1,2006 ti I hereby certify that the above information is coact a04 that the construction on the above ribed property and the occupancy a • the us- will'be in accordance,with the laws, rules and regulations of the to of ashington it, and the City of Federal Way. 42)114.______ Owner or aFjent: a, , -. Date: . `.., THIS CARD IS TO REMAIN ON-SITE arY OF '' Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT#: 06-105609-00-EL Owner: J C STORAGE LLC Address: 35400 PACIFIC HWY S FEDERAL WAY, WA 98003 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence On-going inspections are logged on the back of this card. 0 Slab/Concrete Floor(4255) ❑ Ditch cover(4030) ,❑ Pool Bonding(4195) Approved to place concrete Approved Approved By Date By Date By Date ❑ Temporary Power(4275) ❑ Service(4235) ❑ Feeders/Sub-panels (4045) Approved Approved Approved By Date By Date By Date /4 Rough Electrical(4225) 121Ceiling Cover(4020) K Final-Electrical (4055) Approved Approved Approved 1' .„ ;01,, B ��!�� Date By�i��) Date (a� Do By N� Date i RE, �P IIM ❑ Under-slab groundwork(4295) Approved By Date aXid 1/Cz-fl G C: 11n p&ct-- RECEIVED D 1 U �- h PERMIT - COMMUNITY DEVELOPMENT SEEVICCSQV 0 2006 SF MF CO ME PL DE EN FP 333258TM AVENUE LWAY,WA 98•63.971PO A T��T CATION FEDERAL WAY,WR 98063-97t8F ily��_�•-+ 1 Tn /// 253-835-2607.FAX 253-835-2612, ,®►�" 011 UILDING DEPT. , The following is required information-an incomplete application will not be accepted. Please print legibly(in ink)or type. • PROPERTY INFORMATION SITE ADDRESS ,35...400_3 PPCL rt C 1-4WD/ 6, capL JA i su�2, SUITE/IINIT# ASSESSOR'S TAX/PARCEL# Z 41 Z 1 V y - ' LOT SIZE(sf) �+ W-ro!L Z, :c1 St76e/4 G E. LEGAL DESCRIPTION(e.g,Acme Estates,Lot 1) /'���L- (A pagefor tes 1-- description) a PROJECT INFORMATION TYPE OF PERMIT 0 BUILDING 0 PLUMBING 0 MECHANICAL 0 DEMOLITION X ELECTRICAL 0 ENGINEERING 0 FIRE PREVENTION SYSTEM PROJECT DESCRIPTION(Provide de fled description of work included on this permit onizt) +v s-p LC rI 4lcc evw VV LTxI G r Lc=.c7ai CAr DUGR ("LY Qjn,s, CCTV 1''ivi CtTh- re v 5 PROJECT NAME(Name of Business or Owner Last Name) Fe-De. W>tir Eta • . 77)J pct (t. C FI i-t;c is PEOPLE INFORMATION PROPERTY NAME PRIMARY PHONE OWNER TC 6TOES E. LLC Eli))$7S -?'RC MAILING ADDRESSCITY,STATE,ZIP E-MAIL ADDRESS 3664 ZU�1�N A S.E. I4Ji2.1.1 WA. 480'2 CONTRACTOR COMPANY NAME l APPLICANT NAME OFFICE PHONE ACC �ys-r / ,s 4Pais IN c 36441.1 W t)LLxi nn (3110)ggz -541q3 c) +b NG X ZO34/C] NcouMAILS ciTY.STATE.Vb �W� -i OVo`- (ELL PHONE - ((CIIITTYYY OF FEDERAL WAY BUSINESS LICENSE NUMBER EXPIRATION DATE FAX NUMB/`ER ( 06 CONTRACTOR'S REGISTRATION NUMBER ) �q3 COPY of card requiredEXPIRATION DATE E-MAIL ADDRESS with each application APPLICANT COMPANY NAME APPLICANT NAME OFFICE PH• (CCt.ILING S4jStEhlb Ptu, INC. TORN WUt Ar- *•6) :4-1 - �11i3 �" �XXADDRESS�� � CITY,STATE.ZIP CELL PHONE RELATIONSHIP* 7. 63PROJEy / VAN cooveri WA. Wg Z- ( ) - (.(t vu.-r FAX NUMBER 0 Architect o Tenant o Agent V Other ii FAX &-.6 )Zga -61/i3 PROJECT ALME ^7 PRIMARY PHONE E-MAIL ADDRESS � CONTACT (kbt l ML'yeV" trr D�u G1.3Y.N ((4)2SZ -5114i LENDER NAME Per RCW 19.27.095: � Lender information is required if project value exceeds$5,000 MAILING ESS CITY,STATE,ZIP PHONE ( ) _ ■ DETAILED BUILDING INFORMATION EXISTING USE PROPOSED USE 613 EXISTING ASSESSED/APPRAISED VALUE $ VALUE OF PROPOSED WORK $ --251 3-7 Z SPRINKLERED BUILDING? p YES L NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED? JF YES = NO WATER SERVICE PROVIDER �. LAKEHAVEN = HIGHLINE = TACOMA 7. PRIVATE(WELL) ( _ SEWER SERVICE PROVIDER LAKEHAVEN = HIGHLINE 7. PRIVATE(SEPTIC) V( L" AREA DESCRIPTION EXISTING PROPOSED TOTAL SQ.FT. SQ.FT. SQ. FT. BASEMENT FIRST SECOND THIRD FOURTH ADDITIONAL FLOORS (DESCRIBE) DECK (COVERED?) GARAGE E CARPORT E EXISTING PROPOSED TOTAL TOTAL EXISTING SF TOTAL PROPOSE'SF TOTAL SF NUMBER OF FLOORS "NEW HOMES ONLY" NUMBER OF BEDROOMS_ ESTIMATED SELLING PRICE S____ FtXTd RES Indicate number of each type of fixture to be installed or relocated as part of this project Do not include existing fixtures to remain. MECHANICAL Value of Mechanical Work $ AIR HANDLING UNITS EVAPORATIVE COOLERS GAS LOGS REFRIG.SYSTEMS BBQS FANS HOODS(Commercial) WOODSTOVES BOILERS FIREPLACE INSERTS RANGES MISC(Describe) COMPRESSORS FURNACES GAS WATER HEATERS DUCTS GAS PIPE OUTLETS PLUMBING BATHTUBS(or Tub/Show,Comb,) SHOWERS WATER CLOSETS(T ) MISC(Describe) DISHWASHERS SINKS DRINKING FOUNTAINS GAS PIPE OUTLETS SUMPS RAINWATER SYST WASHING MACHINES URINALS HOSE BIBBS LAVS(Bathroom Sinks) VACUUM BREAKERS ELECTRIC WATER HEATERS DISCLAIMER:SIGNATURE kLOCI< I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal-Way as to any claim(including costs, expenses, and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person,including the undersigned,and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy of the information supplied to the city as a part of this application. ` NAME/TITLE \ �� 'm hilar ( 6?r- DATE /0- /6,-Ore.- RELATIONSHIP TO PROJECT = Ow er = Agent Contractor - Architect = Other FOR OFFICE USE ONLY NEW -ADDITION =ALTERATION 1 REPAIR = TENANT IMPROVEMENT BUILDING SHELL ONLY? =YES NO BASIC PLAN? =YES = NO ZONING DESIGNATION CHANGE OF USE? =YES = NO NEW ADDRESS REQUIRED? YES = NO UP/SEPAJSU? = YES NO PLATTED LOT? =YES = NO DEMO PERMIT REQUIRED? = YES NO . , P • ELECTRICAL PERMIT INFORMATION RESIDENTIAL COMMERCIAL NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE LI Family Square Feet Service or Feeder Each Add'n (First 1300 ft2-$1.07.50; Each add'n 500 ft2-$34.50) ❑ 0 to 100 amp $117.00 71.50 U Detached outbuilding or garage ❑ 101-200 amp 145.00 91.50 (Inspected with service) $45.50 ❑ 201-400 amp 272.00 107.50 ❑ Detached outbuilding or garage U 401-600 amp 317.00 127.00 (Inspected separately) $71.50 ❑ 601-800 amp 410.00 173.50 U 801 - 1000 amp 500.50 209.50 NEW MULTI-FAMILY(three units or more) ❑ Over 1000 amp 546.00 291.00 Service Feeder ❑ Up to 200 amp $117.00 $34.50 ❑ Over 600 volts surcharge $91.50 ❑ 201 -400 amp 145.00 71.50 ❑ Mast or meter repair $99.00 ❑ 401. -600 amp 198.50 99.00 U 601 -800 amp 254.00 136.00 ALTERED COMMERCIAL/INDUSTRIAL ❑ Over 800 amp 364.00 272.00 Service or Feeders ❑ 0 to 200 amp $117.00 ALTERED SINGLE/MULTI FAMILY U 201 -600 amp 272.00 ❑ 601 - 1000 amp 410.00 Service or Feeder ❑ over 1000 amp 456.50 ❑ Oto 200 amp $89.50 ❑ 201 -600 amp 145.00 ❑ #of circuits to be added/altered ❑ over 600 amp 218.50 (1-5 circuits-$91.50;Add'n circuits,$7.00/ea) ❑ #of circuits to be added/altered COMMERCIAL/INDUSTRIAL PLAN REVIEW (1-4 circuits-$71,50;Add'n circuits$7.00Jea) $91.50 plus 35%of Permit Fee ❑ Service- 1,000 amps or greater U Mast or meter repair $53.50 ❑ Medical/Educational/Institutional Facility MOBILE HOMES U Service or feeder only $71.50 ❑ Service and feeder $117.00 TEMPORARY SERVICE MOBILE HOME/RV PARK Residential/Multi-Family $63.00 ❑ #of service or feeders (First service/feeder-$71.50;each add'n-$46.50) Commercial/Industrial Service or Feeder Ampacity Li 0- 100 amps $71.50 ❑ 101 -200 amps 91.50 ❑ 201-400 amps 107.50 U 401-600 amps 145.00 ❑ over 600 amps 157.00 MISCELLANEOUS SERVICE/EQUIPMENT U #of Thermostats LI #of Signs (First-$53.50;add'n-$16.50/ea) (First sign-$53.50;add'n sign$25.00/ea) X,Low Voltage 0 Li r U Swimming pool/hot tub $107.50 Square Feet to be served by system(s) (Includes additional circuit,if required) Fire Alarm System U Yard Pole meter loops $71.50 Security Alarm System ❑ Additional Plan Review $107.50/hour ❑ Voice Cabling (for modified submittals) ❑ Data Cabling U Automation Fee on all Permits .. $5.00 (Per System(s) 1a 2500 ft'.-$63.00; Each add'n 2500 ft2-16.50) *Per WAC 296-46-910(5)(b)(rte 4+)