05-104801 • City of Federal Way 'Community Development Services Electrical Permit #: 05 - 104801 - 00 - EL P.O.Box 9718 Federal Way,WA 98063-9718 Ph:(253)835-7000 Fax:(253)835-2609 Inspection request line: (253) 835-3050 Project Name: WEYERHAEUSER RHODODENDRON GREENHOUSE Project Address: 2525 S 336TH,61" Parcel Number: 212104 9002 Project Description: Addition of(2)120V 20amp branch circuits in Greenhouse area.Circuits are to be fed through 120'of SCH-80 PVC pipe buried underground Owner Applicant Contractor WEYERHAEUSER COMPANY UNICCO SERVICE COMPANY UNICCO SERVICE COMPANY PROPERTY ACNTNG TB 9 840 S 333RD ST 840 S 333RD ST TACOMA WA 98477-0001 FEDERAL WAY WA FEDERAL WAY WA (253)924-3776 • Electrical Fixtures Description iipuantity Description Quantity Description Quantity Circuits- Commercial 2 PERMIT EXPIRES March 19,2006. ;; Permit issued on September 20,2005 I hereby certify that the above information is correct°'and that the construction on the above described property and the occupancy and the use Will be in accordance with the taws,rules and regulations of the State of Washington and the City of Federal Way. �j� Owner or agent: 21[ Date: � 2encos— FINALED 64i) fri\ THIS CARD IS TO REMAIN ON-SITE CITY OF ACommunity Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 . PERMIT#: 05-104801-00-EL Owner: WEYERHAEUSER COMPANY . Address: 2525 S 336TH ST 1 FEDERAL WAY, WA 98003 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ❑ Slab/Concrete Floor(4255) .❑ Ditch cover(4030) Pool Bonding(4195) Approved to place concrete Approved Approved By Date By/� / Date ,/,--4,Z/- By Date ❑ Temporary Power(4275) 0 Service(4235) 0 Feeders/Sub-panels(4045) Approved Approved Approved By Date By Date By Date ❑ Rough Electrical (4225) ❑ Ceiling Cover(4020) 0 Final-Electrical(4055) Approved Approved Approved By Date By Date By Date O ( 0 Under-slab groundwork(4295) Approved By Date w - s 05_ _i_ a _ c ,r)1 ` Federal Way EC^" 'C �r�+ U PERMIT SF MF CO M" EL P DE EN FP • COMMUNITY DEVELOPMENTSERVI � QE 333258TH AVENUE •63BOX 97]8 APPLICATION FEDERAL WAY,,WAWA 9980639718 TD 253-835-2607•FAX 253-835-260Q�E P 2 0 Z Imam ituottederalwau.com `� The ollowin• i _ _ i•,;• _' • y,•tion-an inco •fete a••lication will not be acce•ted. Please •tint le•ibi in ink or •e. • PROPERTY INFORMATION SITE ADDRESS 33663 Weyerhaeuser Way South, Federal Way,WA 98001 SUITE/UNIT# ASSESSOR'S TAX/PARCEL# 2 1 2 1 0 4 - 9 0 0 2 LOT SIZE(sf LEGAL DESCRIPTION(e.g.Acme Estates,Lot 1) Weyerhaeuser Bonsai Collection (Attach separate page for lengthy legal descdp ion) • PROJECT INFORMATION TYPE OF PERMIT ❑BUILDING 0 PLUMBING 0 MECHANICAL 0 DEMOLITION ❑✓ ELECTRICAL 0 ENGINEERING ❑FIRE PREVENTION SYSTEM PROJECT DESCRIPTION(Provide detailed description of work included on this permit onlu) Install two 120V-20A branch circuits in the Greenhouse area. Circuits are to be fed through 120'of SCH-80 PVC pipe buried under ground. PROJECT NAME(Name of Business or Owner Last Name) LA) -- etc V l�.(9,LA Sell - to ..S a i • PEOPLE INFORMATION PROPERTY NAME PRIMARY PHONE OWNER Weyerhaeuser ( 253 ) 924 - 6235 MAILING ADDRESS CITY,STATE,ZIP PO Box 9777 Federal Way,WA 98063 CONTRACTOR COMPANY NAME APPLICANT NAME OFFICE PHONE UNICCO Service Company Terry McAdams ( 253 ) 924 - 6700 MAILING ADDRESS CITY,STATE,ZIP CELL PHONE PO Box 9777 Federal Way,WA 98063 ( 253 ) 732 - 1296 CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER EXPIRATION DATE FAX NUMBER 2 0 _0 1 _ 1 0 0 2 3 8_ 12 / 31 / 05 ( 253 ) 942 - 0306 L CONTRACTOR'S REGISTRATION NUMBE opy of card re fired with each application) EXPIRATION DATE UNI CCSCOO12 / 19 /2006 APPLICANT COMPANY NAME APPLICANT NAME OFFICE PHONE UNICCO Service Company Jeff Mostrando ( 253 ) 924 - 6457 MAILING ADDRESS CITY,STATE,ZIP CELL PHONE PO Box 9777 Federal Way,WA 98063 (253 ) 229 - 7370 RELATIONSHIP TO PROJECT FAX NUMBER 0 Architect Ej Tenant Ei Agent 0 Other(Describe) Project Manager ( 253 ) 942 - 0736 CONTACT NAME PRIMARY PHONE E-MAIL ADDRESS Jeff Mostrando ( 253 ) 924 _ 6457 jeff.mostrando@weyerhaeuser.com LENDER PerRCW.t9?T 09$ Lender irifotriuxni<�h is , NAME required `project value exceeds$5 OOO `'. MAILING ADDRESS CITY,STATE,ZIP • DETAILED BUILDING INFORMATION EXISTING USE PROPOSED USE EXISTING ASSESSED/APPRAISED VALUE $ - VALUE OF PROPOSED WORK $ SPRINKLERED BUILDING? 0 YES ❑ NO FI- 'a -OPPRESSION SYSTEM PROPOSED/REQUIRED? 0 YES ❑ NO WATER SERVICE PROVIDER 0 LAKEHAVEN o H t- E 0 TACOMA ❑ PRIVATE(WELL) SEWER SERVICE PROVIDER ❑ LAKE - N 0 HIGHLINE 0 PRIVATE(SEPTIC) iv •' PROJECT FLOOR AREAS AREA DESCRIPTION I EXISTING PROPOSED TOTAL J SQ.FT. SQ.FT. SQ.FT. • BASEMENT FIRST SECOND THIRD FOURTH ADDITIONAL FLOORS(DESCRIBE) DECK(COVERED?) GARAGE 0 CARPORT 0 NUMBER OF FLOORS EXISTINGrn. ._.. 'erns TOTAL0**"eG l Tofu rRP»st. xotwsr **NEW HOMES ONLY** NUMBER OF BEDROOMS E IMATED SELLING PRICE $ FIXTURES Indicate number of each type of fixture to be installed or r- ated as part of this project. Do not include existing fixtures to remain. MECHANICAL Value of Mechanical Work $ AIR HANDLING UNITS EVA'•RATWE COOLERS GAS LOGS REFRIG.SYSTEMS BBQS F'. S HOODS(commercial) WOODSTOVES BOILERS IREPLACERNACES INSERTS .. GES MISC(Describe) COMPRESSORS FUGAS ATER HEATERS DUCTS GAS PIPE OUTLETS PLUMBING BATHTUBS(or'Nb/shower SHOWERS WATER CLOSETS(Yo let) MISC(Describe) DISHWASHERS SINKS DRINKING FOUNTAINS GAS PIPE OUTLETS SUMPS RAINWATER SYST WASHING MACHINE URINALS HOSE BIBBS LAYS(Bothroom sites) VACUUM BREAKERS ELECTRIC WATER HEATERS DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses, and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city,including its officer d employees,upon the accuracy of the information supplied to the city as a part of this application. I NAME/TITLE i 1 �►'"`��G� PI (Title) DATE k� ,e 9 � igna ure) (Title) RELATIONSHIP TO ROJECT ❑ Owner 0 Agent 0 Contractor 0 Architect 0 Other FOR;O.F ���[I��3'�'3i f' a R O ADDITION cr ALTERATION' a REPAIR a TENANT IMPROVEM N $UILDAYG ALT.OELY? a a NO . BASIC LAN? 0 a NO OI DESIUNAT]CDN I GE OF 'SE ' a'YES n Ni) NEW ADD"...AEII,tED7 , rl,''JtES d N© UP/SOPA/$YJ? a YES in NI); PLATTED LQ#"i' I MO PERMIT REQUIRED? =' n YES a NO ra YE8 a NO Bulletin#100—January 7,2005 Page 2 of 4 k�Flandouts\Permit Application • • ELECTRICAL PERMIT INFORMATION • RESIDENTIAL COMMERCIAL NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE Service or Feeder Each Add'n ❑ Single Family Square Feet (First 1300 ft2-$104.50;Each add'n 500 ft,-$33.50) U 0 to 100 amp $113.50 $69.50 ❑ Detached outbuilding or garage ❑ 101-200 amp 141.00 89.00 (Inspected with service) $44.00 ❑ 201-400 amp 264.50 104.00 ❑ Detached outbuilding or garage ❑ 401-600 amp 308.00 123.50 (Inspected separately) $69.50 17 601-800 amp 398.50 168.50 O 801 - 1000 amp 486.50 203.50 NEW MULTI-FAMILY(three units or more) ❑ Over 1000 amp 530.50 283.00 Service Feeder ❑ Up to 200 amp $113.50 $33.50 ❑ Over 600 volts surcharge $89.00 ❑ 201 -400 amp 141.00 69.50 ❑ Mast or meter repair $96.00 ❑ 401 -600 amp 193.00 96.00 ALTERED COMMERCIAL/INDUSTRIAL U 601 -800 amp 247.00 132.00 ❑ Over 800 amp 353.50 264.50 Service or Feeders ❑ 0 to 200 amp $113.50 ALTERED SINGLE/MULTI FAMILY U 201 -600 amp 264.50 U 601 - 1000 amp 398.50 Service or Feeder ❑ over 1000 amp 443.50 ❑ 0 to 200 amp $87.00 ❑ 201 -600 amp 141.00 O'er'#of circuits to be added/altered ❑ over 600 amp 212.50 (1-5 circuits- . 9.00)Add'n circuits,$7.00/ea) ❑ #of circuits to be added/altered COMMERCIAL/INDUSTRIAL PLAN REVIEW (1-4 circuits-$69.50;Add'n circuits$7.00/ea) $89.00 plus 35%of Permit Fee ❑ Service- !:: - . • eater ❑ Mast or meter repair $52.00 ❑ -.tcal/Educational/Ins dtutional Facility MOBILE HOMES .f-lV / f U Service or feeder only $69.50 ❑ Service and feeder $113.50 TEMPORARY SERVICE MOBILE HOME/RV PARK Residential/Multi-Family $61.00 ❑ #of service or feeders (First service/feeder-$69.50;each add'n-$45.00) Commercial/Industrial Service or Feeder Ampacity ❑ 0- 100 amps $69.50 ❑ 101-200 amps 89.00 ❑ 201-400 amps 104.50 ❑ 401-600 amps 141.00 ❑ over 600 amps 152.50 MISCELLANEOUS SERVICE/EQUIPMENT ❑ #of Thermostats ❑ #of Signs (First-$52.00;add'n-$16.00/ea) (First sign-$52.00;add'n sign$24.50/ea) U Low Voltage U Swimming pool/hot tub $87.00 Square Feet to be served by system(s) (Includes additional circuit,if required) ❑ Fire Alarm System U Yard Pole meter loops $104.50 ❑ Security Alarm System U Additional Plan Review $104.50/hour ❑ Voice Cabling (for modified submittals) ❑ Data Cabling El ❑ Automation Fee on all Permits .. .00 (Per System(s) 1.t 2500 ft2-$61.00; Each add'n 2500 ft2-16.00) •Per WAC 296-46-910(5)(6)(i&ii) Bulletin#100-January 7,2005 Page 3 of 4 k\Handouts\Permit Application •