05-104757 1 City of Federal Way Electrical Permit #: 05 - 104757 - 00 - EL Community Development Services P.O.Box 9718 1111 Federal Way,WA 98063-9718 • Ph:(253)835-7000 Fax:(253)835-2609 Inspection request line: (253) 835-3050 Project Name: 4tORTHLAKE RIDGE 2I3t' Project Address: 33123 40TH$ Parcel Number: 618141 0350 Project Description: Installing a new 200 amp service and wiring. Installing a new LIV security system. Owner Applicant Contractor QUADRANT CORPORATION,THE MERIDIAN CENTER ELECTRIC INC MERIDIAN CENTER ELECTRIC INC PO BOX 130 11109 66TH AVE E 11109 66TH AVE E BELLEVUE WA 98009 PUYALLUP WA 98373 PUYALLUP WA 98373 (253)848-5595 Electrical Fixtures Description Quantity L Descriptio n Quantity Description fQ uantity Low Voltage Burgler Alarm-Residen 3506 I Service: Residential 3506 PERMIT EXPIRES March 18,2006. Permit issued on September 19,2005 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in acco s ance with the laws,rules and regulations of the State of Washington and the City of Federal Wa 4 Owner or agent: _ 61 Date: g:f �f�s Ftt p ILE THIS CARD IS TO REMAIN ON-SITE CITY OF Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT #: 05-104757-00-EL Owner: QUADRANT CORPORATION, THE Address: 33123 40TH AVE S FEDERAL WAY, WA 98001 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Slab/Concrete Floor(4255) 0 Ditch cover(4030) 0 Pool Bonding(4195) Approved to place concrete Approved Approved By Date By Date By Date ❑ Temporary Power(4275) ® Service(4235) 0 Feeders/Sub-panels (4045) Approved Approved Approved By Date B �, , Date \%_`.;1_—CS By Date S Rough Electrical (4225) 0 Ceiling Cover(4020) ,❑ Final-Electrical(4055) Approved Approved Approved By Q Date ‘\_.xa_c„,S By Date Date i_2r✓ _crc ❑ Under-slab groundwork(4295) . -ac- (, - JIIe r tyiol-w-e- Approved By Date 09/16/2005 FRI 13:51 FAX 253 841 0892 MERIDIAN CENTER ELECTRIC Z017/091 CITYOF RECEIVED () (;- - ( 0 . 4 / 5 C? Federal Way PERMIT COMM INITYDEVELO?ME?fr :kwlr SSEP 1 9 2005 SF MF CO M ''D PL DE EN FP 93.945/in,ell/MIN.1r71 ATX•Po Box g71Y I C A T I O N Ph"DEKAL W.fY•WA 9BOria.77 g 7D •• 252 ea5.207,FAX 253-s.35-:0�'n/8-Ty— OF FEDER L w•m'.""`°ff`g-ST1 2e'° BUILDING DEPT, A — The_ollowing is re.wired information-an incom.'etc a. .Tication will not be accepted. Please -rint legibly in ink)or Ell PROPERTY INFORMATION SITE ADDRESS 33\2 J O1 f - S SUITE/UNIT# _ ASSESSOR'S TAX/PARCEL # 19 I g , L.4 1 - 3 LOT SIZE(si) LEGAL DESCRIPTION (e.g.Acme ESIettes, Lot 1) (AnGN,..Nurutc pugnf lengthy repnf drs.rpfiun) ■ PROJECT INFORMATION TYPE OF PERMIT [7 BUILDING �❑ PLUMBING 0 MECHANICAL 0 DEMOLITION 1�/ELECTRICAL 0 ENGINEERING 0 FIRE PREVENTION SYSTEM PROJECT DESCRIPTION(Provide detailed description of work included on this permit(Fiji) New single family residence/ 200 amp service / S e(.V r I A-v� PROJECT NAME(Name of Business or Owner Last Nome) Norhtlake Ridge • PEOPLE INFORMATION • PROPERTY NAME PRIMARY PHONE OWNER -4Uarsixt... . --.. ... ----- (--425') 455-.290-6-- MAILING ADORE9y CITY,STATE,EN. PC Box 130 Believe, WA 98009 CONTRACTOR COMPANY NAME APPLICANT NAME OFFICE PI IONE Meridian Center Electric ICeri Ilene ( 253 ) 848 5595 MAILING ADDRESS CITY,STATE,%M.' CELL PHONE: 11109 66th Ave E Puyallup, WA 98373 ( ) _ CITY OF FEDERAL WAY HUSINESS LICENSE NIIMORE EXPIRATION DATE FAX NUMBER 2 0 0 0 1 0 2 1. 6 2 0 0 - g T. 12/31/2005 ( 253 ) 841 -- 0892 CONTRACTORS REGISTRATION Nl IMSER!copy of card required wIt) each eppUcetlou) EXPIRATION rATe. MERIDCE318SG 02/28/07 APPLICANT COMPANY NAME APPLICANT NAME. OFFICE PHONE. Merid11m Centel'Electric ( ) MAILING Ar1I1RI.s CITY,STATE,EII' CELL PHONE RELATIONSHIP TO PKOJECT FAX NllMkiEK -- n Architect GI Tenant O Agent 0 Other(Describe) ( ) • CONTACT NAME PKIMARY PI IONE N-MAIL ADDRESS Kari Relic 1 ( 253 ) 848 - 5595 Keri(iMCElectric.com LENDER fpe,i4AP w,y w '/k,' ,,.•Y-/W .i", m0:4044 NAME 1 , r ,nlr ,y,.,, P �, �Jt,,"; . aQl -MAILING ADDRESS CITY.nitre,ZIP ■ DETAILED BUILDING INFORMATION EXISTING USE PROPOSED USE EXISTING ASSESSED/APPRAISED VALUE $ VALUE OF PROPOSED WORK $ SPRINKLEREI)BUILDING? 0 YES o NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED? 0 YEs n NO WATER SERVICE PROVIDER u LAKEHAVEN ❑ HIGHLINE 0 TACOMA ❑ PRIVATE(WELL) SEWER SERVICE PROVIDER 0 LAKEHAVEN ❑ HIGIILINE 0 PRIVATE(SEPTIC) 09/16/2005 FRI 13:51 FAX 253 841 0892 MERIDIAN CENTER ELECTRIC 018/091 PROJECT FLOOR AREAS • AREA DESCRIPTION EXISTINQ PROPOSED TOTAL _ SQ. T. SQ FT. SQ. FT. BASEMENT .. -- -- T -. SECOND - THIRD FOURTH ADDITIONAL FLOORS(DESCRIBE) - L)ECK(COVERED?) ,_ GARAGE 0 CARPORT U '-- -- — NUMBER OF FLOORSmemm PRorOALD TOTAL • ...xot.u. r71°sr tarwr.rnorossnar,,,,,.. .,.,. Tattyes "NKWHOMES ONLY NUMBER OF BEDROOMS ESTIMA'T'ED SELLING PRICE $ • • FIXTURES of type offrxture to be in-started or relocated ris art ofthis .project. ... not include ting rtur to remain.i._.._...,..... Indicate number each p p jest. Do existing frxtures r MiCCIUANICAL Value of Mechanical Work $ AIR HANDLING UNITS EVAPORATIVE COOLERS GAS LOGS RE:FRIG,SYSTEMS ::• EANS_.---- HOOAsicommerciall w.c:QDsTou.E.R.. ......------ - BOILURS FIREPLACE INSET r RANGES MISC(Describe) COMPRESSORS FURNACES GAS WATER HEATERS DUCTS GAS PIPE OUTLETS PLUMBING BATHTUBS(,,,Tub/shnwrComDo) SHOWERS WATRK CLOSETS troueu MISC(Describe) DISHWASI-f1:Rs SINKS DRINKING FOUNTAINS GAS PIPE OUTLETS SUMPS RAINWATER SYST WASIIING MACHINES URINALS HOSE BIBBS LAYS(a,.W.n poSInroI VACUUM BREAKERS ELECTRIC WATER HEATERS DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perfury that the information furnished by me le true and correct to the best of my knowledge, and further, that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of_Federal Way as to any claim(including costs, expenses, and attorneys'fees incurred itt the investigation and defense of such claim), which may be made by any person,including the undersigned, and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application, NAME/TITLE / _ r` DATE (o fgnnty rp) q 1/y `us 171Uc1 9� RELATIONSHIP TO PROJECT 0 OWncr 0 Agent ❑ Cox tractor ❑ ArchiLrc-t 0 Other , v >P oas tWl ` : [ n.( Q�; R. DIrION. c TION.!-.i.,, , E XN I;MP12d n „:4:•::-.• „❑I�LTITERA ;R REpr'i1R;:;. ., ,',�; �T � �,:. Y.�IKETdT'.'.'�%.::• .. -,, , I!r{, r S$EL. �?.: . b Y? ;•6 li 0 ,: '.,? ASIC,PL;AN?:'` •.:., .IgE i- n NO. ONINQ DESIGNAI`10$ •” .. . `:CHANG�'`''tl�`;Yi�E? ',,b;,XE`S' ' �❑NO .lYEW ADDRESS REQ'UIRED? o YES..o BYO • • . • -•up/SEPA/SU?:' n YES n NO_ ' PLATTED LOT? o YES NO . . . DIv,[O PERMIT REQUIRED? . • CrYE$ O.NO Bulletin 4200—January 7,2005 Page 2 of 4 k\Handouts\Permit Application 09/16/2005 FRI 13:51 FAX 253 841 0892 MERIDIAN CENTER ELECTRIC Z019/091 ELECTRICAL PERMIT INFORMATION RESIDENTIAL COMMERCIAL NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE ASingle Family Square Fcct 3.5O .p Service or Feeder Bort Actd'n (FirM 1300 ft2.-$104.50; L•'ach adern 500 ft2-$33.50) ❑ 0 to 100 amp $113.50 $69.50 ❑ Detached outbuilding or garage Q 101-200 amp 141.00 89.00 (Inspected with service) $44.00 0 201 -400 amp 264.50 101.00 ❑ Detached outbuilding or garage ❑ 401 -600 amp 308.00 123.50 (inspected separately) $69.50 060 -800 amp 398.50 168.50 0 801 - 1000 amp 486.50 203.50 NEW MULTI-FAMILY(three units or more) ❑ Over 1000 amp 580.50 283.00 Service Feeder ❑ Up to 200 tunp $113.50 $33.50 ❑ Over 600 volts surcharge $89.00 U 201 -400 amp 141.00 69.50 ❑ Mast or meter repair $96.00 0 401 -600 amp 193.00 96.00 © 601 -800 amp 24'/-00 132.00 ALTERED COMMERCIAL/INDUSTRIAL O Over 1100 amp 353.50 264.50 Service nrFctrders ❑ 0 to 200 amp $113.50 ALTERED SINGLEJMULTI FAMILY ❑ 201 -600 amp 264.50 CI601 - 1000 amp 398.50 Service or Feeder CI0 to 200 amp $57.00 ❑ over 1000 amp 143.50 O 201 600 amp 141.00 ❑ _ #of circuits to be added/altered 0 over 600 amp 212.50 (1-5 circuits-$89.00;Add'n circuits,$7,00/ca) ❑ #of circuits to be added �MMERCIAD 321�VIEW c>ltert d.." (1-4 circuits-$69.b0;;Add'n circuits 57.00/es) $89.00 plus 3.5%of Permit Fcr, -'--- ❑ Service - 1,000 amps or greater ❑ Mast or meter repair $52.00 ❑ Medical/Educational/Institutional Facility MOBILE HOMES ❑ Service or feeder only $69.50 ❑ Service and feeder $113.50 TEMPORARY SERVICE MOBILE HOME/RV PARK Residentlai/Muiti-Family $61.00 0 if of service-or feeders (First service/feeder-5(19,50;each add'n-445.00) Commerciai/Industrial Service or Feeder Ampacity ❑ 0- 100 amps $69.50 ❑ 101 -200 tulips 59.00 ❑ 201 -400 amps 104,50 ❑ 401 -600 amps 141.00 ❑ over 600 amps 152.50 MISCELLANEOUS SERVICE/EQUIPMENT Li #of Thermostats ❑ .__-#of Signs �(First-$52.00; add'n-$16.00/ca) (Fust sign-$52.00; acid ri sign$24.50/ea) I.ow Voltage Q Swimming pool/hot tub... £87.00 Qco. Square Feet to be served by system(s)35 w (Includes additional circuit,if required) 0 Fire Alarm System ❑ Yard Pole meter loops $104.50 .4 Security Alarm System U Additional Plan Review O Voice Cabling $104.50/hour D Mull Cabling (for modified submittals) ❑ 0 Automation Foe on all Permits „ $5.00 (Per Syatenm(%) 1,,2500 fc2-$61.00; Each addd'n 2500 ft2-16.00) 'Par wFl<:29640-o10(5/bki&ii) Bulletin#100-January 7,2005 Page 3 of 4 k\Handouts\Permit Application