Loading...
05-104756 • at 1 City of Federal Way . Electrical Permit #: 05 - 104756 - 00 - EL . Community Development Services P.O.Box 9718 Federal Way,WA 98063-9718 Ph:(253)835-7000 Fax:(253)835-2609 Inspection request line: (253) 835-3050 ' Project Name: lisIORTHLAKE RIDGE 2/34$1 Project Address: 33131 40TH,tS , Parcel Number: 618141 0340 Project Description: Installing a new 200 amp service and wiring Owner Applicant Contractor QUADRANT CORPORATION,THE MERIDIAN CENTER ELECTRIC INC MERIDIAN CENTER ELECTRIC INC PO BOX 130 11109 66TH AVE E 11109 66TH AVE E BELLEVUE WA 98009 PUYALLUP WA 98373 PUYALLUP WA 98373 (253)848-5595 Electrical Fixtures Description Quantity Description iQuantityl Description Quantity Service:-Residential 3503 PERMIT EXPIRES March 18,2006. Permit issued on September 19,2005 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in ac ordance with the laws,rules and regulations of the State of Washington and the City of Federal Way / I Owner or agent: t ' ia/ Date: 9/ -5 f IN ALES THIS CARD IS TO REMAIN ON-SITE CITY OF4.1..._41k Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT #: 05-104756-00-EL Owner: QUADRANT CORPORATION, THE Address: 33131 40TH AVE S FEDERAL WAY, WA 98001 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. O Slab/Concrete Floor(4255) 0 Ditch cover(4030) '❑ Pool Bonding(4195) Approved to place concrete Approved Approved By Date By Date By Date ❑ Temporary Power(4275) 0 Service(4235) 0 Feeders/Sub-panels(4045) Approved Approved Approved By Date B > Date By Date ❑ Rough Electrical(4225) 0 Ceiling Cover(4020) 0 Final-Electrical (4055) Approved Approved Approved C � BL' /J Date((—((7-CC, By Date B vP Date(---t b —0 6 O Under-slab groundwork(4295) Approved By Date 09/16/2005 FRI 13:50 FAX 253 841 0892 MERIDIAN CENTER ELECTRIC U012/091 [WY OF t': RECEIVED C S - 1 C 41 c , Federal Way — " PERMIT SF MF CO ME �J Pi, DE EN FP [.Y]h1Federal RUF,STSF.RvliL•S // 25 D .� bNVh'SOUTH•T'0 BOX 77 7.4 s E P 1 9 0 PLICATION FEDERAL WAY,0.'.i 98Uda-1718 7n - ' 25.3-R.?5-26u7•E-1 X 255-835-2do0 /----_ / E, „.d, dcmhzmlm,n CITYY+pOFI�F1ED�EnR�A-L.WA' _ �"�``'-------.`__ The following is rc.uire3Un iiiiina n-pian Incomplete a.-lication will not be accepted. Please •rint legibly in ink)or -c. SITE ADDRESS J 3 I 3 I a r,-- 1-l'' - S2 '`-IC SUITE/UNIT N ASSESSOR'S TAX/PARCEL f! I K .�- 3( 1 - _0 0 LOT SIZE (sf) LEGAL DESCRIPTION(e,g,Acme Estates, Lot 1) _ /.4::u ch..''.nrw r,,g,fcr :h&r..-y.,l d..r..ipeinnl • • PROJECT INFORMATION . . TYPE OF PERMIT ❑ BUILDING ��`IJ PLUMBING CO MECHANICAL ❑ DEMOLITION ELECTRICAL ❑ ENGINEERING n FIRE PREVENTION SYSTEM PROJECT DESCRIPTION (Protlide detailed description of work included Ort this permit onit() New single family residence/ 200 amp service PROJECT NAME(Name of Business or Owner Last Name) Norhtlake Ridge • PEOPLE INFORMATION PROPERTY NAME PkIMARY PHONE —OWNER- •ua.ran . ..._.....-_______ _.-..... . .. ( 425 ) 455-2900--.-... ---- MAILINrI AnI)RE.S.S CCIY,STATE,ZIP -' PO Box 130 Bcllcve, WA 98009 CONTRACTOR COMPANY NAME .-- . ._ APPLICANT NAM1; -- Of-P]CE PHONE Meridian Center Electric Keri Helle ( 253 ) 848 - 5595 MAILING Auuktss CI'rY,:-;TATE, CN].I.PHONE 11109 66th Ave E Puy911tup, WA 98373 ( ) - CITY OF PEOCRAI.WAY BUSINESS LICENSE NUMBER EXPIRATION DATE FAX NUMBER 20 - 00 - 102162 - 00 - H L 12/21/2005 ( 253 ) 841 0892 CONTRACTOR'S REC11TRA'1'ION NUMBER(copy of cud reggirnd with each application) FIX VI KATION DATE MF, RIDCE318SG 02/28/07 APPLICANT COMPANY NAME APPLICANT NAME OFFICe RHONE Meridian Center Electric. MAILING AUDKESS CITY,S'L'ATE,ZIP Clell.,L'HONE RR1.ATir]NSHIP':r)PROJECT FAX NUMB EI : ❑ Architcet n Tenant 0 Agent ❑ Other (Describe) - ) - CONTACT NAME PRIMARY PHONE - ' E-MAI,AnpRESs ueri Hdle ( 253 ) 848 - 5595 RexInMCElectric.com LENDER Rt A.4.�"ti',1i rs'v,- 9,k�„ .: aw r ,,,;,4g, W.. 4 :.,r NAME - _ Mil.;, , .giro heti ,� �k�,.,�y��l,�,••,�,.�Tn,��� t���W (�1f1i''�r MAILING ADDRESS CIITY,STATE,ZIP • DETAILED BUILDING INFORMATION • EXISTING USE _.. PROPOSED USE EXISTING ASSESSED/APPRAISED VALUE $ __VALUE OF PROPOSED WORK $ SPRINKLERED BUIlDING? u YES 0 NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED? p yEs u NO WATER SERVICE PROVIDER n LAKEHAVEN 0 HIGHLINE ❑ TACOMA n PRIVATE(WELL) SEWER SERVICE PROVIDER n LAKEHAVEN 0 HIGHLINE ❑ PRIVATE(SEPTIC) 09/16/2005 FRI 13:50 FAX 253 841 0892 MERIDIAN CENTER ELECTRIC 2013/091 • • PROJECT FLOOR AREAS • AREA DESCRIPTION EXISTING PROPOSED N TOTAL SQ.FT_ SQ. FT. SQ. FT. BASEMENT • • . - SECOND THIRD -- FOURTH — - ADDITIONAL FTA-.)ORS(DESCRIBE) DECK (COVERED?) GARAGE L CARPORT 0 -- - — loarmna raoroeeornr.% 77rwi=MA Qat:, "o' y r¢oe08�to ..- rtoi,a.sv NUMBER OF FLOORS _.1.. , "NEW HOMk.•S ONLY"" NUMBER OF BEDROOMS .. ESTIMATED SELLWNO PRICE S FIXTURES Indicate number of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to rentairt. MECHANICAL Value Of Mechanical Work $ AIR HANDLING UNITS EVAPORATIVIE COOLERS GAS LOGS REFRIG.SYSTEMS FANS .. . .MOODS ic:emm rcl it ...WOODSTOVt;S BOILERS FIREPLACE INSERTS RANGES MISC(Describe) COMPRESSORS FURNACES GAS WATER HEATERS DUCTS GAS PIPE OUTLETS PLUMBING BATHTUBS(nrT,b/Showercamlw) SHOWERS WA'T'ER CLOSETS Romp M15C(Describe) __ DISIHWASHERS SINKS I)RINKING FOUNTAINS GAS PIPE OUTLETS SUMPS RAINWAro-;lt 51ST wA,SH1NC MACHINES URINAIr3 __ HOSE BIEBS LAVS(batnroomBLUcaI VACUUM BREAKERS , ELECTRIC WATER H>r'A'I.5KS DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further, that I un authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal way as to any claim (inoluding costs, expenses, and attorneys'fees Incurred in the investigation and defense of such claim),which may be made by any person,Including the undersigned, and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. �y NA1SIlE/TITLE -t- DATE —IQs (Sty."t&tUrc) (Title) f `G...,.- RELATIONSHIP TO PROJECT CJ Owner 0 Agent C Contractor ❑ Architect ❑ Other 4 uW t 1 r,vo jMP;2OVE �" ^ ,: ',i Pi��, ', ,�.:, o;AL E 'I�QlIT, '•°.REP • ';��LO�S3 g �I.�i3OHLY'? .s :o, x..,�,... . �• v �..,, MP.NT-i .. a L Y S C NU': ..._ 'I �. �C' N� 4 NO Y . .. . .• ZONI.NAPE IONATION.' • R " '"� � • 'G$.APiGE;�p)?USE? .. �°�YES °•NO • NEW.A WF.ESS:REQUIRED? ' v YES >17 NO ,�iJP/SEPA%STI?-' a YES a NO PLATTED IOT'' • a YES_a NO _ DEMO PERIk 1'REQUIRED? a YES• a NO Bulletin#I00 -January 7,2005 Page 2 of 4 _... k\Handout;\Penni[Application 09/16/2005 FRI 13:50 FAX 253 841 0892 MERIDIAN CENTER ELECTRIC [2014/091 ELECTRICAL PERMIT INFORMATION RESIDENTLAL COMMERCIAL NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE �'� iingle Family Square Feet .303 Sertlice or FFFrier Each Add'n (First 1300112-5104.50; Each add•n 500 NJ-$33.50) U 0 to 100 amp $113.50 $69.50 ❑ Detached outbuilding or garage ❑ 101 -2.00 amp 141.00 89.00 (Inspected with service) $44.00 U 201 -400 amp 264,50 104.00 ❑ Detached outbuilding or garage ❑ 401 -600 amp 304.00 123.50 (Inspected separately) 569.50 I] 601 800 amp 398.50 I68.50 ❑ 801 - 1000 amp 486,50 203,50 NEW MULTI-FAMILY(three units or more) 4 Over 1000 amp 530.50 283.00 Seruice Feeder ❑ Up to 200 amp $113.50 $13.50 0 Over 600 volts surcharge $89.00 ❑ 201 -400 amp 141,00 69.50 ❑ Mast or meter repair $96,00 0 401 -600 amp 193.00 96.00 0 601 800 amp 247,00 132.00 ALTERED COMMERCIAL/INDUSTRIAL ❑ Over 800 amp 353.50 264.50 Service or Feeders ❑ 0 to 200 amp $113.5(1 ALTERED SINGLE/MULTI FAMILY ❑ 201 -600 amp 264.50 U 601 - 1000 amp 398.50 Service or Feeder 0 to 200 amp $87.00 0 El over 1000 amp 443.50 0 201 - 600 amp 141-00 ❑ fi of circuits to be added/altered ❑ over 600 amp 212.50' (1-5 circuits-$89.00;Addh circuit~,$7.00/ea) of circuits to l7c adcre.d altered -'' _COMMER AL/INDUSTpL M R ymw r� (1-4 circuity.-$69.50;Add•n circuirr$7,00/ea) • '' 589.00 plus 35%of periiut l`ee ---" "" U Service- 1,000 amps or greater ❑ Mast or meter repair $52.00 U Medheal/Educarional/Tnstitutional Facility MOBILE HOMES a Service or feeder only $69.50 _ ❑ Service and feeder $113.50 TEMPORARY SERVICE MOBILE HOME/RV PARK Residential/Multi-Family $61.00 0 - # of service or feeders (first service/feeder-$69.50;each 9drl'n-$15.00) Commercial/Industrial Service or Feeder Arnpacity ❑ 0 - 100 amps $69.50 O 101 -200 amps 89.00 LI 201 -400 amps 104,50 ❑ 401 -600 amps 141.00 ❑ over 600 amps 152.50 MISCELLANEOUS SERVICE/EQUIPMENT ❑ _ # of Thermostats LI 11 of Signs (First-$52.00; add'n-$16.00/ea) (First sign-$52,00;add'a sigt1 $24,50/ca) k.ow Voltage . ❑ Swimming pool/hat tub $87.00 Square Feat to be served by system(s) - (Includes additional circuit,if required) £1 Fire Alarm Syater 0 Yard Pole meter loops $104.50 ccurity Alarm Sy Itctn ❑ Additional Plan Review $104.5D hour ❑ Voice Csblir t (for modified submittals) / El Data Cabling ❑ ❑ Automation Fee on all Permits „ $5.00 (Per System(s) 1•"2500 f72-$61,00; I•:ach edd'n 2500 111%16.001 -Per WAC 296.46-0 7 0/51/116 9,ii) Bulletin#100-January 7,2005 Page 3 o1 4 -- -- -- k\Handouts\Permit Application