Loading...
18-101900 Building Sing City of Federal way . .-_•- Tr _ , Community Development Dept Permit #:18-101 -I S `' 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax(253)835-2609 Project Name: GOODWIN Project Address: 3128 SW 302ND PL Parcel Number:012103 9070 Project Description: NEW-Construction of a 1-story, 2952 square foot single family residence with a 2319 square foot basement,a 553 square foot covered entry,a 328 square foot deck and a 926 square foot attached garage,including plumbing and mechanical. ***4 bedrooms; $1,000,000 estimated selling price*** Owner Applicant Contractor Lender .. ROGER GOODWIN ROGER GOODWIN ED KOROLAKWOODLAND OWNER IS LENDER 4:10B SW DASH POINT RD UNIT 4: 600B SW DASH POINT RD UNIT 4' REMODELING SVS LLC Lender FEDERAL WAY WA 98023 FEDERAL WAY WA 98023 18835 SE 134TH PL WASHINGTON FEDERAL BANK RENTON WA 98059 2206 S 320TH ST FEDERAL WAY WA 98003 Census Category: 101 -New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: - Floor Area(sq.ft.) 0.00 0.00 Additional Permit Information New/Additional Sq.Feet-1st Floor 2952 New/Additional Sq.Feet-2nd Floor 0 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 0 New/Additional Sq.Feet-Basement. 2319 Basic Plan? No Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 328 New/Additional Sq.Feet-Garage 926 Mechanical to be Included? Yes Plumbing Work Valuation 10000 Mechanical Work Valuation? 10000 Number of Stories 1 New/Additional Sq.Feet-Other 553 Plumbing to be Included? Yes New/Additional Sq.Feet-Total 7078 Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2 family) Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2 Residential Total Valuation:685,748.20 � a Ducting 1 Fans 6 Furnaces 1 Gas Piping 1 Gas Pipe Outlets .3 Hot Water Tanks 1 • f I Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 4 Showers 1 Sinks 1 - Water Closets 3 Hose Bibbs 2 CONDITIONS: NFPA 13D SPRINKLER SYSTEM REQUIRED.NO FRAMING INSPECTION UNTIL FIRE SPRINKLER ROUGH IN APPROVED BY SKFR. A City Right of Way(ROW)Permit is required for the new paved driveway connection to SW 302nd Pl. • tl it ..w . .. + Contact Kathleen Mathena at(253)835-2725 for the permit materials:The ROW Permit must be finalled,prior to Building Final. Height survey shall be provided to the City for review and approval at the time of underfloor framing inspection and prior to final. PERMIT EXPIRES Monday,14 January,2019 Permit Issued on Wednesday,July 18,2018 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: .7/LE I City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use.This certificate is valid ONLY when endorsed by City staff. Tenant Name: GOODWIN Permit# 18-101900-00-SF Address: 3128 SW 302ND PL Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: 0.00 Floor Area(sq.ft.) 0.00 0.00 Owner Name: ROGER GOODWIN Owner Address: 1600B SW DASH POINT RD UNIT 452 FEDERAL WAY WA 98023 Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. • • e THIS CARD IS TO REMAIN ON-SITE f , Federal Way Construction Inspection Record INSPECTION REQUESTS:(253)835-3050 PERMIT#: 18 101900 00 Address: 3128 SW 302ND PL Project: ROGER GOODWIN FEDERAL WAY WA 98023-2342 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg(4400) El Initial Erosion Control(4365) El Footings/Setback(4110) Approved To be done PRIOR to breaking ground.. Approved to place concrete By Date By Date By $t Date -10-/ 9 ® Foundation Wall(4115) ® Drainage/Downspout4040) ® Plumbing Groundwork(4190) Approved to place concrete Approved to backfill ye Approved to cover By Date 3-6"---t By Date By di ', ` Date 3...2.A. • El Slab/Concrete Floor(4255) ® Underfloor Framing(4285) 0 Floor Sheathing(4105) // —Approved to sheath floc/+2„...., Approved to install flooring By G Date ,. 0.- By 6 Dat• � r/� By Date I=1 Shear Walls(4245) an Roof Sheathing(4220) El Rough Plumbing(4230) Approved to install siding r' Approved to install roofing PP Approves By C- Date . ' By al Date /9- Date b Z - al Mechanical Rough-in(4165) M Gas Piping(4125) al Fire/Draft Stops(4095) Approved Approved to release test Approved By d Date j S �, By 41Date $l/f lP �s Date 7//Øp ® Interim Erosion Control(4370) Prior to scheduling a Framing inspection; Q Framing(4120) Approved Electrical,Plumbing&Mechanical Rough-la and Fire/Draft Stop inspections mast be signed- Approved to insulate By Date off sad approved. IBC 109.3.4 ByG / Date? /G El Insulation(4150) ® Gypsum Wallboard Nailing(4130) M Final Erosion Control(4375) Approved to install wallboard Approved to install mud&tape Approved By`(,{' Date By f Date AC / By Date 31 Final-Mechanical(4065) V Final-Plumbing(4075) 7 1 ,al-Building(4050) Approved Approved / Approved .By i Date 3--)3-- o 9c.).,By G-k_ Date 3--13-„,9_ , .,By / Date 7'� 1 s 3-428-lf .. Owe * kern Si/.t4 Aotin*, ,5€106.141`6 o*4& P 0 Rough Electric Pt 0 Final-Electrical D Right of Way Approved Approved Approved •By Date By Date By Date 11, 4t iNt d". .. ,..., . ...... t ,, . q. '''''t• O I.- vt„. . C. ill • 1.4111 .....410 46. 4. q 4111\IN f \ . v d M RECEIVED MAY 0 3 2018 PERMIT APPLICATION 111111111111rmy. CITY F OF FEDERAL WAY ITY DEVELOPMENTPERMIT CENTER.33325 8th Avenue South+Federal Way,WA 98003-6325 Federal Way COMTU 253-835-2607+FAX 253-835-2609+permitcenter(a ityoffederalway.com PERMIT NUMBER I 9 0 L/ l - I - TARGET DATE Sl / / SITE ADDRESS SUITE/UNIT# PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ Rs 7, a a 1 a 1 0 3 - q v_ -7 0 TYPE OF PERMIT xi BUILDING 0 PLUMBING ��❑ MECHANICAL El DEMOLITION 0 ENGINEERING El FIRE PREVENTION NAME OF PROJECT CoC- 1 oc u , Res cc'1 e ice. PROJECT DESCRIPTION Cti -i-r uc-'!`r�t, o - - 5 1- a. /0'c m4 d G T ID 1 S w 0.4t i PI Detailed description of work to be included on this permit only NAME PRIMARY PHONE LI a G %94- 095 Rteje r avNc1 JooactGl tx)AZ k v- 'id5 S 11Q"131 PROPERTY OWNER MAILING ADDRESS E-MAIL 1600 13Sw bast-1 01 2d 1157 rj looc1 iiin @ rnsoecoI, STATE ZIP lea 0�0,9 c .orYlcciSf,.ce �ai may h.)pr �$0 d3 "`' 1,t ADDRESS t cj 1 Q. Da IN- Vick' 0AS-k>x h'ohNE a 5 3 571c S� 333 MAILINCONTRACTOR Po 607 y q . q ft 1,;eTWt-6YCCVIS DVI - STATE COIa WP �Rq, 4` CS FAX „�- WA STATE CONTRACTOR'S LICENSE ft , EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# FAT'RDC lgg5 / NAME 09-e r c h d ,_J aw a 61 cxxa 0! Y1 PHONEPRIMARY 9 4 —(0-1 3 APPLICANT M"°jjoo�j(6 5 yv Dash PF Rci 4 /45.) jaoduiviemsh CO"111 CrI�e ea 1 cI STATliv E ZIP l J Ca� FAX N/A. PHONE PROJECT CONTACT NKK//`�jjQ1e t, --\Wvi 0 0)0U,t r) PRIMARY ci<clq Co.731 (The individual to receive and MAILINGADDRESs ,1 i ^ , li j'5) E-MAIL '`nGeoliCOS4-1 respond to all correspondence tQ DO i3 I'�EAS 1//w�' L�1 PI' Q ( c* et concerning this application) aTwTE zipV PROJECT FINANCING N ME W��- Fed eat i 0 OWNER-FINANCED When value is$5,000 or more ZG 0� ,7,STA 1-2_O'"l Rod e(41 �C 5 -(4 7 7 - 3,05 (RCW 19.27.095) S '' C `I I certify under penalty of perjury that I am the property owner or authorized agent of the pviperty owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. c/7/ / SIGNATURE: " • n _ - DATE / / /�}/ i g U PRINT NAME: (bEa Q 6j j)W I N !!! Bulletin#100-January 29,2016 % Page 1 of 2 k:\Handouts\Permit Application MECHANICAL VALUE OF MECHANICAL WORK PERMIT $ 'O ic Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe) I AIR CONDITIONER1 FIREPLACE INSERTS HOODS(Commercial) BOILERS ' FURNACES L HOT WATER TANKS(Ga,) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT $ 1011--• Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. BATHTUBS(or Tub/Shower Combo) L_. LAVS(Handsinbo) 5 TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS 3SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS a SINKS(Kitchen/utility) WATER HEATERS(electric) HOSE BIBBS SUMPS 1 WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYO SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS IOCC,►►xi ��biC- Y E U1--►1e Lu - hay.2 $ 4-i EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? en-h4 I 5 C>y t ❑Yes t No l Yes ❑ No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT . .3 41- 2-3 iq FIRST FLOOR(or Mobile Home) �5 ql 2i S - SECONDICOR'= COVERED ENTRY 553 553 , DECx 143 324g GARAGE CARPORT 0 12'6. '2 OTHER(describe) EXIBTUfG PROPOSED ��TOTAL � Area Totals ' *rev* ESTIMATED SELLING PRICE$ )I 0 0 0/ v O #OF BEDROOMS 14 COMMERCIAL-NEW/ADDITION AREA DESCRIPTION Area is Occupancy Group(s) Construction #of Additional Information Square Feet Type Stories ADDITION COMMERCIAL-REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area is Occupancy Group(s) Construction #of Additional Information Square Feet Type Stories TOTAL-BOILDIR`O TENANT AREA ONLY PROJECT AREA ONLY Bulletin#100-January 29,2016 Page 2 of 2 k:\Handouts\Permit Application GOODtiVIN SITE PLAN - A PORTION OF THE SW 1/4 AND OF THE SW 1/4 OF SECTION 1, TOWNSHIP 21 N., RANGE 3 E., W.M. CITY OF FEDERAL WAY KING COUNTY, WASHINGTON PROPOSED HOME DETAILS: MAIN FLOOR FFE: 53.17 FEET LOWER FLOOR FFE: 43 FEET MAIN FLOOR AREA: 3672 SQUARE FEET LOWER FLOOR AREA: 2368 SQUARE FEET BUIIAING ELEVATIONS/HEIGHT: FRONT: 53 / 25 +/— FEET REAR: 43 / 35 +/— FEET LEFT SIDE: 48 / 30 +/— FEET L RIGHT SIDE: 49.5 / 28.5 +/— FEET aJ 8 — y cc 00 w 3 O EL C402.5.1.2 BUILDING LEAKAGE TEST: COMPLETED BUILDING SHALL BE TE TED AND THE AIR LEAKAGE RATE OF l° �� TH BUILDING ENVELOPE SHALL NOT o r x(1Et' JU 0.40 CFA T2 AND SHALL BE a\\yeprO�e mm�ays COMPL TED PRIOR TO FINAL BUILDING aY•sn ted\r' nT \a\tw °ot4,6e APPROVAL outcend\ 9'Ext th°rt\ a�\B�ete C\9�e \oP \a abe5em ,into at\ ' o\ ch a d\H °t ocess10 rov\ded\avev\0k SOS • �j0 `r ' \ e\ea SV'0ad Oe eP tam \ \ 95o tce\O d\n9°(� If 15 : IRC R314Smoke Alarms: Smoke alarms shall be installed in the p8 •, �i\ A owing locations: 3 �J \ � InI ) each sleeping room z S it , , On ide each separate sleeping area in the immediate vicinity of the 0 cc , . bedr s (e.g. hall \ 'ys) S`, \ C9 `Tp each dditionaftatory of the dwelling, including b o LL g basements but not a f JaF ding wl spaces and uninhabitable attics. In dwellings or All hold downs shall be installed `r • SCA: p ld�G g units 'th split levels and without an intervening door per the m - N 2� the Sdia t levels, a smoke alarm installed on the upper manufacture b e cc ¢ \ specifications their shall be • leYpel sh s ce fo he adjacent lower level Provided that the lower settingno wet w' w level is less than one fu story below the u of hold downs POQ� ¢ p I n pper level. m Q + \ NLL do N Deck Screw hall N / \ t be hangers cross brfaCi, 9 "Post pu njoist / s W Alert compon mg or nny type ofs beams' Piers, 0 / w oo t in deck&am. gctuml / ,- Jo ¢ Prior to final building inspection Final Erosion and Sedimentation \ ' Lu ¢ �0 Control inspection is required Electrical it � \ byCit a separateo be Performe ' / / residence shalltbe equipped openings wilt soli een wood doors not Permit OFF ede at permit iss e d ' /' a / less than 13/8 inches (35 mm) in thickness, solid or d N �P / honeycomb -core steel doors not less than 13/8 inches \ ermit Center 25 way' con act p5� PQ (35 mm) thick or 20-minute fire -rated doors, 3 ¢ / / 835-260 7 ¢ • a / QOQ QUO , equipped with a selfclosing device \ •¢ m / ¢ / ALERT `� ' U rr / +� m /: ; 0 All erosion control meas56� / ures shall be / _ % N/= to installed prior to any inspection and / m N/ , shall remain intact during ' Cc / ��\ r o •O/ / / SPECIAL INSPECTION iNPECTIONORConstruction. HR aw ES PRECTIN OF—ALLj L NO EXCEPTIONS ° a /C TABLE 1705.7 w n o l0 \ WC)\ 54 At time of footing/foundation/setback inspection, property corners Egress Windows required for bedrooms shall satisfy o o� o� / / shall be identified by an approved the following requirements, per2015 R 310 o° oLL survey marker, existing fencing or • Minimum net clear opening of5.7s.f. (grade floor p� 00°�� other landscape feature is not an windows may have a minimum opening of5sf) `c b / • Minimum net clear opening width of 20 inches. �<Y 0�p ,�o° a // approved property marker o = w m Pub p° // o�f� ' • Minimum net clear opening height of 24 inches. w¢ v (.)2 of vh O °q\ / z o°6J o ,l7?i Zpe O° jFFr'F\ •i° ¢ bayOj / • Maximum sill height of 44 inchesabove floor. o \ N \ GEOTECH TO VERIFY g' COMPACTION MEETS woos / • OR EXCEEDS THE REOUIRMENTS OF g = N \ / / ti • GEOTECH REPORT AND SHALL PROVIDE A R802.10.4 Alterations to trusses '�,/ Truss members shall not be cut, notched, drilled, \/2 , / �rO LETTER OF APPROVAL TO THE CITY spliced or otherwise altered in any way without the INSPECTOR PRIOR TO CONCRETE approval of a registered design professional. \ / PLACEMENT Alterations resulting in the addition of load (e.g., 9� o� \ i y �% s HVAC equipment, water heater) that exceeds the 40 / 4 \— �sOa \ a�.r \ J / �p J design load for the truss shall not be permitted �r ppcKEa o 2 \\ °bo 3 %� \ / a without verification that the truss is capable of 40 50 — // ��63 (J ' supporting such additional loading. ROC F by, a / _ A/yUgTrO ��SO �(J rLl At the discretion of the buildin - �� feature not completely g Inspector, any construction A� ryFq � � �\ ✓\ / �� / rT� the drawings revision may require represented ed an adequately detailed in Fasteners for preservative -treated wood Federal Process'Pe If t revision 5 835-2607via the City f ct Of Federal Way galvanized s f steeshall be of l, stainlpreservaed tive steel, silicon regarding y Permit Center, 253 835 2607, foie information City Of / 5b- ORDINARY HIGHWATER SETBACK \ grequiredforms,dra rmation bronze or copper 2015 R317.3.1 \ 0 ( ) \ ProcessinScity Staff egTo avoid adequate time for revt'ewdocuments. ro�al d hon, 5Rke � . - N.p ` timely manner. necessary delays, Please submit in a �PQ61� ` Fire blocking at concealed space �e _ ` including furred areas vents pipes, Fireplaces at ceiling and floor levels. Provide 0 � ril �l gat 10'intervals in the wall both ,,P P--- \ \ _ • , y i — — — _ �� — Of Federal Way Ho & Vert- IRC302.11 �� , Build ing Division ---- -_Lo � � pis TRUMON TOE Provide �BREA_K WALL _ 10 site at frarnlnruss specs. On inspection - - — 9D d� p �_ ��e� / South King Fire &Rescue 0 20 40 a BREAK WALL 5 I_ _ Approved u, 0 As Detailed - 210.12 Arc -Fault Circuit- le / ub•ect to ttached details NEC A aired in all 120 volt, sing 1 Scale: r Protection req tchen, familY9 / By • inh se g & 20 amp branch circuits, k► living, rooms, ,bedrooms, Date I I L I y 9 (� Ap dens, rec, dining+ s laundry or similar room 1 _ � O �^ sunrooms, closes, hallowaareas N.F.P.A. 13D AUTOMATIC FIRE ` SPRINKLER SYSTEM REQUIRED. �v NO FRAMMING INSPECTION �• `� UNTIL APPROVAL OF THE SYSTEM.