18-103098 Building - Single Family-
- city of Federal Way Permit #:18-103098-0O-SF'
Community Development Dept.
33325 8th Ave S
Federal Way,WA 98003 Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax:(253)835-2609
Project Name: DIWAN
Project Address: 34010 37TH AVE SW Parcel Number: 147330 0020
Project Description: NEW-Construction of a 1678 square foot one-story single family residence with a 19.5 square
foot covered entry and a 465 square foot attached garage. Includes plumbing and mechanical.
Owner Applicant Contractor Lender
SUNEET DIWAN CODY DAKANYEN DESIGN DREXEL CONSTRUCTION LLC OWNER IS LENDER
3717 BRAEBURN DR N 1622 NE 179TH ST 1900 S PUGET DR SUITE 203
TACOMA WA 98422-2224 SEATTLE WA 98155 RENTON WA 98055
Census Category: 101 -New Single Family House
Includes: #1 #2 #3 44
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 1,678.00 0.00
Additional Permit Information
New/Additional Sq.Feet-1st Floor 1678 New/Additional Sq.Feet-2nd Floor 0
New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 1678
New/Additional Sq.Feet-Basement 0 Basic Plan" No
Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0
New/Additional Sq.Feet-Garage 465 Mechanical to be Included? Yes
Plumbing Work Valuation" 14000 Mechanical Work Valuation" 10000
Number of Stories 1 New/Additional Sq.Feet-Other 19.5
Plumbing to be Included" Yes New/Additional Sq.Feet-Total 2163
Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2
family)
Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2
Residential
Total Valuation:225,224.77
'.3 .:i s a # u� i 'ig
6 SS 4 i 4.. if$t d° �; $fig { N° the K x -" 2� �3y
,� .3,a ��.� ts «,�.;� ti ,,<.�, av .�� � � , da I���., „�ai„�th,��lru.,C'...�.L
Fans 5 Fireplace Inserts 1 Furnaces 1
Gas Piping 1 Gas Pipe Outlets 4 Hot Water Tanks ” 1
g
4En,.l�,f-'Yd'�..Jf�..3..,k_ Z!3 ' v L° _.. , ui... .. . s`=
Bathtubs 1 Dishwashers 1 Laundry Washer Outlets 1
Lavatories 4 Showers 1 Sinks 1
Water Closets 3 Hose Bibbs 2
CONDITIONS:
a right-of-way permit is required for any work within the public right-of-way,such as driveway,
drainage,or utility removal or installation. Contact permit desk at 253-835-2725.
Prior to final inspection,a restrictive covenant must be signed and recorded by the applicant. Contact
Ann Dower at 253-835-2732.
Erosion control shown on the plans is the minimum required and may be revised by the SWM inspector
to prevent tracking dirt or discharge dirty stormwater into the city right-of-way or onto private property.
Ln� goe / 7.59
r It
•r 41a
.. r ..I. s.. w _.• . ..lr
._
PERMIT EXPIRES Monday,7 October,2019 ,
Permit Issued on Wednesday,April 10,2019
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
ashi . on and the City of Federal Way.
t)k
Owner or agent: / Date: (/
(0
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance,this structure was in
compliance with the various ordinances of the City regulating building construction or use.This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: DIWAN Permit# 18-103098-00-SF
Address: 34010 37TH AVE SW
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 1,678.00 0.00
Owner Name: SUNEET DIWAN
Owner Address: 3717 BRAEBURN DR N
TACOMA WA 98422-2224
Building Official Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible(within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
J.
•
THIS CARD IS TO REMAIN ON-SITE .
004
•
Federal Way Construction Inspection Record .
y INSPECTION REQUESTS:(253)835-3050
PERMIT#: 18 103098 00 Address: 34010 37TH AVE SW
Project: SUNEET DIWAN FEDERAL WAY WA 98023-2942
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
El SWM Precon Site Mtg(4400) ® Initial Erosion Control(4365) 0 Footings/Setback(4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date By Date By Date � -
AIIIIIMINIIIIIIIIIIIIIMI
El Foundation Wall(4115) u s❑ Drainage/Downspout(4040) ® Plumbing Groundwork(4190)
Approved to place concrete fff Approved to backfill Approved to cover
By // Date 6 / / ' By f J Date 1 (O (- r By Date
® Slab/Concrete Floor(4255) ® Underfloor Framing(4285) Q Floor Sheathing(4105)
Approved to place concrete Approved to sheath floor Approved to install floorin
By Date By`l4P Date r By,,,,,,, Date 1( / / 9
•'1 Shear Walls(4245) ,• /
El Roof Sheathing(4220) I ® Rough Plumbing(4230) ,
Approved to install sidi Approved to install roofin l� i Approved
ByZA.1 Date/l l l f ..By/ws Date l l /9 ':1 By S Date /a)- //717
•El Mechanical Rough-in(4165) El Gas Piping(4125) 0 Fire/Draft Stops(4095)
Approved Approved to release test Approved
BYtfl_$ Date / y ,20,2D0.By Date .J.B'4t) Date / /A.. -0
•El Interim Erosion Control(4370) Prior to scheduling a Framing inspection; tEl Framing 4120)
Approved Electrical,Plumbing&Mechanical Rough-in Approved to insulate
and Fire/Draft Stop inspections must be signed-
By Date off and approved IBC 10934 By A.6
Date /y/
El Insulation(4150) VII Gypsum Wallboard Nailing(4130) El Final Erosion Control(4375)
Approved to install wall.., d Approved to install mud&tape Approved
By Date _ 0 By Date 2 4 ! By Date
El Final-Meehan cal(4065) •El Final-Plumbing(4075) 1 El Final-Building(4050)
Approved Approved Approved
.By Date •;•By Date BY LWS Date V IL/�.0 Q
UFE,' OK -e!4173//7 _4,(A)
e-7}.n^G cs ( ' (ori fro.c17 /Mr16-7
El Rough Electrical El Final ElectricalElRight of Way
Approved Approved Approved
By Date By Date By Date
a 4... •
kIN
1 �
r ✓
.
\)
,p,....A. RECEIVEDPERMIT APPLICATION
CITY OF 4
JUL 13 2018 PERMIT CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325
Federal Way 253-835-2607+FAX 253-835-2609+permitcenterta,cityoffederalway.com
r CT' OF=EDEa.()RADII
a
COMMUNmr OE E
PERMIT NUMBER _ / 03 o q g _ S (3 ✓I 1. I a
CC�� F TARGET DATE
SITE ADDRESS SUITE/UNIT#
S9°f0 3 7g, Ave c 1) 1c&rG. I c.JG, 4 q@;
PROJECT VALUATION ZONING / ASSESSOR'S TAR/PARCE /
$ 70, 0 ��. � I 3 3 v - a
ty$U
TYPE OF PERMIT ILDING PLUMBING IN,//MECHANICAL ❑ DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION
NAME OF PROJECT SUm / ' / `.�'` 1 ( W a✓',
/V i -z-1 es-0-4 S,A1 le) c ►"/// -S,-F '•
PROJECT DESCRIPTION '�_
Detailed description of work to �� t 1,C- 4.A. A.
be included on this permit only
NAME c PRIMARY PHONE
oNe, ,/klo• -k
ZS
3, ?6l, 3 C
PROPERTY OWNER MA LI G ADDRESS E-MAIL
3 Lia 10 37 4rt .c ..„„,,,,,,,,-,..„0„.„,."
S, Q
Mcfc-,1 (Aii-N... ZIPqe0a5
` PHONE
6_-›,,,'
_-› ,,c+rUG4-)vA /(C
MAILING ADDRESS E-MAIL
CONTRACTOR
CITY STATE ZIP FAX
WA STATE CONTRACTOR'S LICENSE M EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE#
/ /
NAME ___ PRIMARY PHONE -
CC,C
APPLICANT MAILING ADDRF S 6 Z Z /t7 f 7q/ + EMAIL
c.a/Gyeivics.com,
CITY -` `'�.. 1e STATE�W4 Zip_
s 5 FAX
NAME , PRIMARY PHON
PROJECT CONTACT i)/•./1-- . l_.0.6--- Z•4))1
The individual to receive and MAILING ADD SS - ]''� L ,fj E-MAIL ' /
respond to all correspondence /v LA� /'� / / �/� �'1 .,0 --C�i s Yi� .;. cow.
concerning this application) CITYS? ,, s/T,_AT , zIP,.� 1 j( �+ FAX ,/ /
NAME (+t,�1� t/� o ,�,�
PROJECT FINANCING L' OWNER-FINANCED
When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RCW 19.27.095)
(7. 3., 161. Z '3 C
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in
the investigation and defense of such claim), which may be made by any person,including the undersigned,and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a part of this application.
L-/ ._ 7"3 _ S'i
SIGNATURE: ! �6 DATE 0
PRINT NAME: /7 v
Bulletin#100—January 29,2016 Page 1 of 2 k:AHandouts\Permit Application
1
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT $ /01
D// o D D
Indicate how many of each type offixture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
AIR HANDLING UNITS 5 FANS j f GAS PIPE OUTLETS OTHER(Describe)
AIR CONDITIONER /TFIREPLACE INSERTS T HOODS(Commercial)
BOILERS 1TFURNACES / HOT WATER TANKS(Cm)
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
I DUCTING , GAS PIPING WOODSTOVES
VALUE OF PLUMBING WORK
PLUMBING PERMIT $ / f D D b
Indicate how many of each type offixture to be installed or relocated as art of this project.Do not include existing fixtures to remain.
JI BATHTUBS dor Tub/Shower Combo) —1 LAVS Hand Sinks) TOILETS WATER PIPING
DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
DRAINS I SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS I SINKS(Kitchen/Utility) WATER HEATERS(Electric)
HOSE BIBBS SUMPS , WASHING MACHINES // TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY? ATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
1ee-aM," G)C''tCr ice, dcs $
Ed PREVIOUS
USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSIO 'SYSTEM?
' l" 1' l 5)/07 ❑Yes NIA O ❑Yes W.-No
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
BASEMENT
FIRST FLOOR(or Mobile Home) 167? 1 78
SECOND FLOOR
COVERED ENTRY /qv S A . S., S.
DECK
GARAGE /CARPORT D 46 (,L/C
OTHER(describe) t(.f J
Area Totals E7ISTING PROPOSED TOTAL
zl6 5 Z/6 Z,S
**NEW HOMES ONLY**
(
ESTIMATED SELLING PRICE$ (7 100 f 0 00 #OF BEDROOMS 3
COMMERCIAL-NEW/ADDITION
AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information
Square Feet Type Stories
NEW BUILDING
ADDITION
COMMERCIAL-REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information
Square Feet Type Stories
TOTAL BUILDING
TENANT AREA ONLY
PROJECT AREA ONLY
Bulletin#100—January 29,2016 Page 2 of 2 k:AHandouts\Permit Application
I
CENTER OF (El ASPHALT
WALKWAY
CCENTER OF STREET
I
I''^^
VJ
UJ
IQ
I—
ti
co
I PROPOSED 310 -
SQ-FT MIN
PAVED DRIVEWAY
20' ONTO SITE
SITE PLAN
SCALE 22X34 1" = 10'-0"
SCALE 11X17 1" = 20'-0"
VICINITY MAP
FROM GOOGLE MAPS
hL'YfYI(iu,
S
h�
)ay SPa.
;1
o EW CONC, DRIVEW Y
+I ( INEW CONC. WAILKWY
i l I - } - f
Z
LU �� LL
LU� �"
D- \
1 19" DIA. TREE
a 33,
34(li „?1K�;S4i;ih 5t
4010 TIM
Avenue Southwest
PROJECT INFORMATION
OWNER
JURISDICTION
PARCEL NUMBER
ZONING
LOT AREA
SENSITIVE AREA
U E N
FEDERAL WAY Al
147330-0020
RS7.2
8107 SQ-FT
N/A
5" DIA. TREE
�o
PROPERTY LINE+ 135-
- El
no OMMOMMENN
RP OPERTY LINE ± 175'
PROJECT DESCRIPTION
NEW 2144 SQ-FT SINGLE STORY SFR. NEW DRIVE WAY.
LEGAL DESCRIPTION
CENTENNIAL ESTATES DIV #1 PP ACT 39023452 MOBILE
HOME
PLAT LOT: 2
YARD CALCULATIONS
REAR YARD = 5 FEET REQUIRED
REAR YARD = 5'
FRONT YARD = 20 FEET REQUIRED
FRONT YARD = 20'
SIDE YARD = 5 FEET REQUIRED
SIDE YARD = 5'
1
� f
1
f �
+I
w
10"C61 1,2
} J
LU
d
f 0
d
8" DIA. TREE 1
f
-�� .. �.��
Igo a.
• v i � S a�'e.o- 5�.� �
�t-
AREA TABULATIONS
CONDITIONED SPACE
MAIN FLOOR LEVEL
1678 SQ-FT
TOTAL
1678 SQ-FT
UNCONDITIONED SPACE
FRONT PORCH
19.5 SQ-FT
GARAGE
465 SQ-FT
TOTAL
484.5 SQ-FT
TOTAL AREA
2162.5 SQ-FT
IMPERVIOUS COVERAGE
ROOF EAVE
2558 SQ-FT
DRIVEWAY
519 SQ-FT
CONC. STEPS
40 SQ-FT
WALKWAY
19 SQ-FT
TOTAL
3136 SQ-FT
% HARDSCAPE = 100 * 3136/8107 = 39%
South King Fars
Approved
$As Detailed
CJ Subject itached details
BY ewe
Date _ 0
LEGEND
s PROPERTY LINE OF PROPOSED PROJECT
PROPERTY LINE OF ADJACENT PROPERTIES
- CONTOUR LINE - 5' ELEVATION CHANGE
INEW STRUCTURE
CENTER LINE OF STREET
EDGE OF CONCRETE
------- ROOF OUTLINE
— — PROPERTY SETBACK
EXISTING TREES/FOLIAGE TO REMAIN
AVERAGE BUILDING ELcVATION 0' 21' S' 70' 20'
22x34: SCALE 1" = 10'
11x17: SCALE 1" = 20'
0' 2� 5' 10' 20' �\
LOT COVERAGE
TOTAL LOT AREA 8107 SQ-FT
BUILDING FOOTPRINT 2143 SQ-FT
TOTAL 2143 SQ-FT
MAX ALLOWED LOT COVERAGE = 60% * 8107 =
4864 SQ-FT
PROPOSED LOT COVERAGE = 100 * 2143/8107 =
26%
City of Federal Way
Building Division
APPROVED F CONSTRUCTION
1
r
Date`' ��Iq
AVERAGE BUILDING ELEVATION CALCULATION
MIDPOINT ELEVATION
EXTERIOR WALL LENGTH
X * x
A
= 390
a
= 51.71
20166.9
B
= 389.9
b
= 46.25
18032.88
C
= 390.2
c
= 51.71
20177.24
D
= 390.3
d
= 46.25
18051.38
195.92
176428.39
Formula 1:
76428.392
195.92
0 SHEET
INDEX
C0.0
SITE PLAN & PROJECT INFO
C1.0
TESC & DRAINAGE PLAN
C2.0
DRAINAGE NOTES & DETAILS
A1.1
GENERAL NOTES & WINDOW & DOOR
SCHEDULE
A2.1
MAIN FLOOR PLANS
A2.2
ROOF PLAN
A3.1
ELEVATIONS
A3.2
ELEVATIONS
A4.1
BUILDING SECTIONS
A5.1
ARCHITECTURAL DETAILS
S1
STRUCTURAL NOTES & TYPICAL DETAILS
S2
FOUNDATION AND MAIN FLOOR
FRAMING PLAN
S3
ROOF FRAMING PLAN & SHEAR WALL
PLANS
S4
SHEAR WALL SCHEDULE & TYPICAL
SECTIONS
J
z
Ui
�z
o
mo'
a-
U 'i U
H w
w
w O
o
a U
Qv
wo'
u
�¢
�Z
{�
L
Nu
M Z
V J
aw
•_
N O
N
O�
1.-:
U
N X
�
w=
r
w ,
>:w
Z
N
I
APPROVAL STAMP
ENGINEER STAMP
J
Q
LU
:g
W
ch
Q
_
Q
N
00
QW
°'
z
LL
z`n�
0 LIJ<<
w
�zwmQ
Z
LU
Z)
w
zLLJ
fy
o
Q
�/
U)
(n
M
LU
LL
JOB NO. 18-071
HALF SCALE 11x17
FULL SCALE 22x34
SHEET
CO.O
RESUBMITTED
JAN 0 2 2019
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT