03-105430 t. s 4 11111,
r •
,.
city° `Lir at `y i Building - Commercial Permit #:03 - 105430 - 00 - CO
commurih Development Services
33530 1st AV'ay S
Federal Way,WA 98003-6210
' Ph:253.661 4000 Fax:253.661.4129 Inspection request line: 253.835.3050
Project Name: FEDERAL WAY YOUTH DEVELOPMENT CENTER
Project Address: 31455 28TH AVE S Parcel Number:092104 9054
Project Description: NEW-Proposal to construct a new,one-story 16,000 sqft teen center with gymnasium,games room,
learning center,computer center,arts room,& administrative and service space. Bldg will be
constructed slab on grade,pre-cast,insulated concrete panes,
Owner Applicant Contractor Lender
BOYS AND GIRLS CLUBS OF KIN( WEINSTEIN COPELAND ARCHITEt W G CLARK CONSTRUCTION CO BOYS AND GIRLS CLUBS OF KING
BOYS AND GIRLS CLUBS OF KIN( 121 STEWART ST SUITE 200 WGCLAC*370N0(08-12-05) BOYS AND GIRLS CLUBS OF KIN(
i 603 STEWART ST SUITE 300 SEATTLE WA 98101 408 AURORA AVE N 603 STEWART ST SUITE 300
ISEATTLE WA 98101 SEATTLE WA 98119 SEATTLE WA 98101
Includes:
Census category: 318-New a1 I #1 U #2 #3 1 #4
Occupancy Group A 2 1 i A-3 ��
Construction Type. - -
_ Type V One-HR JL Type V-One-HR V
Occupancy Load _ 440 4m�Fl or Area(Sq.Ft.): 1 6906 � 4Q05 1,
I 'a r
+w+t
1st Floor Proposed Sq.Feet 16;000 Building Pre-con.Meeting Required Yes
Census Category 318-New amusement,social, Fire Sprinklers Yes
Mechanical No Number of Stories 1
Permit for Building Shell Only No Permit for Foundation Only No
Plumbing No Special Inspection Required Yes
Total Proposed Sq.Feet 16,000 Will Certificate of Occupancy be Issued9 Yes
Sensitive Areas9 No Zoning Designation CC-F
CONDITIONS:
1)This decision shall not waive compliance with future City of Federal Way codes,policies,or standards relating to the
subject proposal.
2)Frontage improvements on S 317th Street and 28th Avenue S must be completed prior to certificate of occupancy for this
building.
PERMIT EXPIRES November 7,2004.
Permit issued on May 11,2004
I hereby certify that the above information is correct and that the construction on the above described property,.and
the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washingtbii-and
the City of Federal Way.
Owner or agent: IDM Date: 5• "- 2001r
• . 2p0 _
Yciqo941
t
City of Federal Way •
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code certifying that at
the time of issuance,this structure was in compliance with the various ordinances of the City regulating building
construction or use. This certificate is valid ONLY when endorsed by City staff.
Tenant Name: FEDERAL WAY YOUTH DEVELOP. Permit number: 03 - 105430-00
Address: 31455 28TH S
r #1 1 #2 #3 �� #41 il
rOccupancy Group A-2.1 A-3 e --1
, Construction Type: Type V-One-HR Type V-One-HR
ccupancy
F — - -
FOloor Area(Sq.Ft.): 6906 I� 4605
Owner BOYS AND GIRLS CLUBS OF KING COUNTY&FEDERAL,WAY PUBLIC SCHOOL --_i
Name: BOYS AND GIRLS CLUBS OF KING COUN'
Address: 603 STEWART ST SUITE 300
SEATTLE WA 98101
)MK. ridssac.%, cao ryes
Building Official b',/�b/(y/e( Date
The priority focus in the review and inspection made by the City prior to issuance((of this Certificate was on those matters which experience has shown most severely
affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time
and personnel limitations),the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance
with each and every ordinance or regulation of the City or the State of Washington affecting the co.7struction or use of said structure or the land upon which it is
situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
• , ' 1 .
THIS CARD IS TO REMAIN ON SITE
CITY OFA....._A,l" COMMUNITY DEVELOPMENT INSPECTION
Federal Wal RECOIVR INSPECTION REQUEST PHONE
#(253)835-3050
PERMIT#: O 3— 05 30 `00 PROJECT NAME: EX 3 a(Tk (ith(c
❑TEMP.EROSION CONTROL(4365) 0 FOOTING/SETBACKS(4110) 0 FOUNDATION WALLS(4115)
To be done prior to breaking ground Approved to place concrete Approved to place concrete
By i '`r+Ps ate 7/v/OV By Z_(N Date/•2 S:d 1 By Date
yeLDRAINAGE/DOWNSPOUT(4040) ❑RE-STEEL( t.f _(c 0 GROUNDWORK PLUMBING(4190)
Approved to backfill Approved to place concrete or grout Approved to cover
iJikr
By Date By Date By Date
0 SLAB ON-GRADE(4255) ❑UNDERFLOOR(4285) ❑FLOOR SHEATHING(4105)
Approved to place concrete Approved to sheath floor Approved to install flooring
Nim
By Date By Date By Date
0 SHEAR WALLS(4245) 0 ROOF SHEATHING(4220) ❑ELECTRICAL ROUGH-IN(4225)
Approved to install siding' Approved to install roofing Approved
By 4 10714 0ByBy �k
Date ��/ � Date Date
0 PLUMBING ROUGH-IN(4230) 0 MECHANICAL ROUGH-IN(4165) 0 GAS PIPING ROUGH-IN(4125)
Approved Approved Approved to release test
14/P4 WA-
By Date By Date By Date
0 FIRE STOPPING(4095) _ FRAMING(4120)
Approved
NOTE:
Prior to framing inspection,all rough-in& proved to insulate
firestopping sign-offs must be approved.
By Date IBC 109.3.4?UBC 108.5.4 By rte/ Date Z/'7/0c
0 INSULATION(4150) ❑GYP.WALLBOARD NAILING(4130) 0 SUSPENDED CEILING GRID(4265)
Approved to install wallboard �j/� �jJ Approved to mud&tape �r, Approved to drop tileohs
By ri'/ Date 0/Zy/'V By �-vI Date `/q/v5 By Date
FFINAL-FIRE(4060) 0 FINAL-PLANNING(4070) RIFINAL-PUBLIC WORKS(4080)
Approved �j Approved Approved
By G.r. Date 49/i 3/Or By eft Date 4toc
By ^ _ _ fes/Date y/Ja
' f FINAL-S.W.M(4375) ❑FINAL-ELECTRICAL(4090) 'FINAL-BUILDING(4050)
/� Approved Approved /` Approved •+
By �� Date By LI Date 9 W B Date / / Ou
-, • t
INSPECTION LOG
003 - /O51/30 -Ca - do
DATE INSPECTOR OK CORR/REJ AREA AND TYPE OF INSPECTION
*I/0Y "2-, X SC-7-0/fr?,5" Aef/2-oP4V,
OtZfrj - Poor/AJCs Fvg c r/ii(L,,ve5 /Z 1 B e
qR/Ac IvD) .
WV Fif x Pmnn, creel_ mrFvtivo/tr/vn/A/.fZLS ,vim
yin (1/Ne 1-2 B &l er2/C C,b a) .
7/1/D% Lc u ,u-F'°r/NG L✓6/fr-eRse,sP & /Acro,-al( ,
'QAC
?/z!/o4 111 ctik, Wall bets eh . IVA -C .7 %k.
Aritoz - ,I , % _
7/2voh le A '0fit(4 VII parr/ -6141iJA+.Qli Wall gni
k►f5' foin/f01t)07 vall Pk per 'airy
iheicy lLe X iME?STI- IS(..A.$ zi,JS� moi
//g0(( , X f iri,UC 0/2Atii✓ jNt y 1726a/✓D
PeRinerex a' $1)/4,0/44 -o, .
/*"i' Ike- X 4 Cotii a<r et.
r
9/1e2kii fre/P XI alAhVi r Gi,i," ogty Mond ert/ol,..ve , fly 3
DN lveS - S/O ' / 0'b ,
Nl4Voy ff.,' )e 4ea'eo -erra,ds DArr,) !I,//DI0 y /1/i shill iu u..
atertleien. /2ao/r®.v91,
1111104- 1711c t PROM/14 __ ..w,v7Lififore.. Ithor,ty 0A/4s-
112.710 A F, rn fox eiu /NRerrKootiAdie-51</ter
,4r.-moi-, . See it/ew om ImptieriimJAiwee 14i�4.c.
1131/o( fZf )e 1Z w i, EWESAeTWN 1.3-1.6)61219A1DB6rwN
• .9 -1.3 , Art4Dc.e1De-toC.i6rw14 .9 -I.1 _oil.
W3/or X D 40?-tL t� z.. -c, 1k 14-6
4. Pan•v15 i- 4V m i-n/ • fit-f-7(e Ar-tie4-
#1141 xrr2,f, ye. /v/17t/4/4 .
10,3 1 BF2-
s '\ ,;(-N
(-N4 ,;
-i
RI
D ,
v
z VVC
t.
k ).1 ,
%_,,,
(t\ ) ..0.-
\.1
‘rilui
(.), Nib et
C
dZi K
Nt a n 't 1 i:_-. it.
r
C \ ,?t41 4,-
�
S S Oo
o
1
LIN
`off
N o
0
o (\ � -
'h
• r CE VED � CO
CONSTRUC1iON PERMIT APPLICATION
CITY OF I
Federal Wa 52003 APPLICATION NUMBER: 3 q -a
Y
APPLICATION NUMBER:, - — — — —
—
CITY or FEDERAL WAY APPLICATION NUMBER:
BUILDING DEPT. — — — _ _ — _
**The following is required information—Please print(in ink)or type**
Please note: Electrical,Fire Prevention Systems and Engineering permits may require a separate application.
■ PROPERTY INFORMATION
SITE ADDRESS: 31455 28th Ave South ASSESSOR'S TAX/PARCEL#: 0 9 2 1 0 4 - 9 0 5 4 aa�5
LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY):
Refer to G 002 of the drawing set
• PROJECT INFORMATION
TYPE OF PROJECT(This application): X BUILDING —PLUMBING —MECHANICAL —DEMOLITION
—ELECTRICAL —ENGINEERING —FIRE PREVENTION SYSTEM
PROJECT DESCRIPTION(Provide detailed description):
Construction of new one-story 16,000 sf teen center consisting of a gymnasium, games room, learning
center, Computer center and arts room with supporting administration and service spaces. Building will be
constructed of slab-on-grade, pre-cast insulated concrete panels, metal stud walls with metal siding, steel bar
joists with metal deck. The building will be fully sprinklered.
PROJECT NAME: Ex3 Youth Center
• PROJECT INFORMATION
PROPERTY OWNER: NAME: DAYTIME PHONE:
Federal Way School District ( 253 ) 945 - 5934
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP):
1066 South 320th Street,Federal Way,WA 98003
CONTRACTOR: NAME: DAYTIME PHONE:
W.G.Clark Construction Co. ( 206) 624 -5244
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE:
408 Aurora Avenue North,Seattle,WA 98109 ( ) -
CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER:
0 2 1 0 1 0 1 0 - 0 0- BL ( 206 ) 682 - 7126
CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE:
(copy of card required) W G C L A C * 3 7 0 N 0 08/12/2005
APPLICANT: NAME: DAYTIME PHONE:
'on A.Mihkels,AIA(Weinstein A l U Architect&Urban Designers ( 206 ) 443 - 8606
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE:
121 Stewart Street,Suite 200,Seattle,WA 98101 ( ) -
RELATIONSHIP TO PROJECT: FAX NUMBER:
X ARCHITECT —TENANT —OTHER(DESCRIBE): ( 206 ) 443 - 1218
E-MAIL ADDRESS:
CONTACT PERSON FOR THIS PROJECT: PROPERTY OWNER X APPLICANT CONTRACTOR JonM@WeinsteinAU.com
• PROJECT INFORMATION
EXISTING USE: N/A EXISTING BUILDING ASSESSED/APPRAISED VALUATION $ N/A
PROPOSED USE: Entertainment•vate Club PROPOSED VALUATION FO•PROVEMENTS: $
SPRINKLERED BUILDING? X YES _NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED: _YES _NO
WATER SERVICE PROVIDER: X LAKEHAVEN _HIGHLINE _TACOMA _PRIVATE(WELL)
SEWER SERVICE PROVIDER: X LAKEHAVEN _HIGHLINE _PRIVATE(SEPTIC)
**NEW RESIDENTIAL CONSTRUCTION ONLY**
NUMBER OF BEDROOMS: ESTIMATED SELLING PRICE: $
• PROJECT FLOOR AREAS
FLOOR EXISTING SQ.FT. PROPOSED SQ.FT. TOTAL
BASEMENT N/A
FIRST 0 SF 16,000 SF 16,000 SF
SECOND N/A
THIRD N/A
FOURTH N/A
OTHER FLOORS(DESCRIBE) N/A
DECK N/A
GARAGE N/A
HOW MANY FLOORS?
O SF 16,000 SF 16,000 SF
TOTAL:
• FIXTURES
Indicate number of each type of fixture
MECHANICAL
6 AIR HANDLING UNIT(S) 0 EVAPORATIVE COOLER(S) 0 GAS LOG(S) REFRIG.SYSTEM(S)
0 BBQ(S) FAN(S) 1 HOOD(S) 0 WOODSTOVE(S)
O BOILER(S) 0 FIREPLACE INSERT(S) 1 RANGE(S) MISC.( )
COMPRESSOR(S) FURNACE(S)
DUCT(S) GAS PIPE OUTLET(S) HEAT SOURCE:_ELECTRIC X GAS
PLUMBING
O BATHTUB(S) 5 LAVATORY(S) 2 URINAL(S) 1 WATER HEATER(S)
1 DISHWASHER(S) 0 RAIN WATER SYS. VACUUM BREAKER(S) X ELECTRIC _GAS
2 DRINKING FOUNTAIN(S) 0 SHOWER(S) 1 WASH MACHINE OUTLET
GAS PIPE OUTLET(S) 3 SINK(S) 7 WATER CLOSET(S) MISC.( )
INTERCEPTOR(S) 9_ SUMP(S)
• DISCLAIMER/SIGNATURE BLOCK
I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and
further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I
further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the
investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of
Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy
of the information supplied to the city as a part of this application.
_ca&A ,-.'rk(6E ��—
NAME/TITLE: Jon A.Mihkels,AIA—Weinstein A i U DATE: December 15.2003
_PROPERTY OWNER X APPLICANT _CONTRACTOR
•
•
—
POR OFFICE USE ONLY:
NEW —ADDITION ALTERATION REPAIR _TENANT IMPROVEMENT
CENSUS CODE: LOT'SIZE: .7"1:";
ZONING,DESIGNATION: 4, `wq,� a' UILDING SHELL ONLY? f YES �NO `a
COMP PLAN DESIGNATION ," BASIC PLAN? _YES; _NO
SECTION TOWNSHIP RAN a NEW ADDRESS REQUIRED? YES _.NO I!
PLATTED LOT? —YES _NO ' 'HANGED F USE? _YES _NO
COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•PO BOX 9718•FEDERAL WAY,WA 98063-9718•253-661-4000•FAX:253-661-4129
www.citvoffederal way.com
Construction Permit Fee Calculation Sheet
*******PLEASE NOTE: ALL FEES MUST BE VERIFIED BY CITY STAFF PRIOR TO ACCEPTANCE OF PAYMENT.
CHECKS FOR INCORRECT AMOUNTS WILL NOT BE ACCEPTED!*******
Building,mechanical,and fire prevention system fees are based on the following schedule.
TABLE A
TOTAL VALUATION FEE FACTOR
(1)$1.00 to$500.00 (1)$30.00
(2)$501.00 to$2,000.00 (2)$30.00 for the first$500.00 plus 34.00 for each additional 3100.00 or fraction thereof,to and including
$2,000.00
(3)$2,001.00 to$25,000.00
(3)$90.00 for the first
$2,000.00 plus 318.00 for each additional 31.000.00 or fraction thereof,to and
including$25,000."
(4)$25,001.00 to$50,000.00
(4)$504.00 for the first$25,000.00 plus$13.00 for each additional 31000.00 or fraction thereof,to and
including$50,000.00
(5)$50,001.00 to$100,000.00
(5)$829.00 for the first$50,000.00 plus 39.00 for each additional 1.000.00 or fraction thereof,to and
including$100,000.00
(6)$100,001.00 to$500,000.00
(6)$1,279.00 for the fiirst$100,000.00 plus 37.00 for each additional 31.000.00 or fraction thereof,to and
including$500,000.00
(7)$500,001.00 to$1,000,000.00
(7)$4,079.00 for the fist$500,000.00 plus 36.00 for each additional 31.000.00 or fraction thereof,to and
including$1,000,000.00
(8)$1,000,001.00 and up
(8)$7,079.00 for the first$1,000,000.00 plus 34.50 for each additional 51,000.00 or fraction thereof.
Bold number is the base fee for the specified increment
Italicized.underlined number is the fee cer additional soecified increment
PLUS: Add 65 percent of the base building permit fee for plan review fee.
Add 25 percent of the base mechanical permit fee for mechanical plan review fee.
Add 15 percent of the base building permit fee for Fire District#39 surcharge,commercial only.
Add$4.50 for WA State Building Code Council,plus$2.00 per unit for duplex&above.
**Electrical,plumbing,and mechanical fees are calculated separately**
■ BUILDING
PROPOSED VALUATION:
FEE FACTOR FROM TABLE A: Number: (a)Base Fee:
(b)Additional Increment Fee:
Estimated Permit Fee: (1)
Estimated Plan Review Fee: (2)
Estimated FW FireDepartment Surcharge: (3)
(COMMERCIAL ONLY)
• MECHANICAL
PROPOSED VALUATION:
FEE FACTOR FROM TABLE A: Number: ((ab))
AdditionaBaseFee:l Increment Fee:
Estimated Permit Fee: (4)
Estimated Plan Review Fee: (5)
• FIRE PREVENTION SYSTEM
PROPOSED VALUATION: