Loading...
20-104351_Water & Sewer Availability Cert-11-06-2020 v17204800172 7204800174 7204800186 wtr swr.docx (Form Update 3/13/20) Page 1 of 4 WATER CERTIFICATE OF AVAILABILITY Lakehaven Water & Sewer District – Development Engineering Section 31623 – 1st Ave S  PO Box 4249  Federal Way, WA 98063-4249 Email: DE@Lakehaven.org  Telephone: 253-945-1581 or 253-945-1580 This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations in Lakehaven’s or Other Purveyor’s system facilities. Proposed Land Use: Building Permit-SFR () Building Permit-MFR (130 units) Building Permit-Other Subdivision () Short Subdivision () Binding Site Plan Boundary Line Adjustment Other (specify/describe) city land use/building permit processes Tax Parcel Number(s): 7204800172, 7204800174, 7204800186 Site Address: 276XX Pacific Hwy S Ex. Bldg. Area to Remain: UNKNOWN sf New/Add’l Bldg. Area Proposed: 49,230 sf LWSD GIS Grid: K-03 WATER SYSTEM INFORMATION 1. Water service can be provided by service connection to an existing ” diameter water main that is approximately feet from the site. 2. Water service for the proposed site development will require an improvement to LWSD’s water distribution system of: a. feet of ” diameter water main to reach the site; and/or b. The (additional) construction of a water distribution system on the site; and/or c. A major portion of LWSD’s comprehensive water system plan would need to be implemented and/or constructed; and/or d. Other (describe): LWSD Developer Extension (DE) Agreement required. Re-construction (to upsize) of existing offsite water main(s) &/or connection to other existing offsite water main(s) may be required, to achieve onsite fire flow GPM required by the fire marshal. 3. a. The existing water system is in conformance with LWSD’s Comprehensive Water System Plan. b. The existing water system is not in conformance with LWSD’s Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of water service outside of LWSD’s water service area. b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Water service is subject to: a. Payment of connection charges (to be determined by LWSD, for any new/modified service connection); b. Proof or reservation of easement(s) as required by LWSD; c. Other: LWSD Service Connection application required, for any new/modified service connection. Comments/special conditions: Care shall be taken to avoid encroachment upon existing LWSD water and/or sewer mains, and/or associated easement(s), on the site. Service pressure(s) greater than 80 psi indicated, Pressure Reducing Valve(s) indicated, contact local building official for requirements &/or additional information. The nearest fire hydrants are/will be on the Property (as marked on map on the back of this page &/or as required by fire marshal). System hydraulic model results (FF #372, copy attached), at no less than 20 psi, indicate that LWSD’s standard maximum allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 1,500 GPM for two (2) hours or more. This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements, contact LWSD for additional information. 578 Pressure Zone Est. Meter Elevation(s)-GIS: High 336+/-, Low 320+/- Est. Pressure Range at Meter(s) (psi): 102-117 I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR Signature: Brian Asbury (e-signed) Date: 11/3/2020 7204800172 7204800174 7204800186 wtr swr.docx (Form Update 3/13/20) Page 2 of 4 7204800172 7204800174 7204800186 wtr swr.docx (Form Update 3/13/20) Page 3 of 4 SEWER CERTIFICATE OF AVAILABILITY Lakehaven Water & Sewer District – Development Engineering Section 31623 – 1st Ave S  PO Box 4249  Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580  Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven’s or Other Purveyor’s system facilities. Proposed Land Use: Building Permit-SFR () Building Permit-MFR (130 units) Building Permit-Other Subdivision () Short Subdivision () Binding Site Plan Boundary Line Adjustment Other (specify/describe) city land use/building permit processes Tax Parcel Number(s): 7204800172, 7204800174, 7204800186 Site Address: 276XX Pacific Hwy S Ex. Bldg. Area to Remain: UNKNOWN sf New/Add’l Bldg. Area Proposed: 49,230 sf LWSD GIS Grid: K-03 SEWER SYSTEM INFORMATION 1. Sewer service can be provided by service connection to existing 8” diameter sewer mains that are on the site and the sewer system has the capacity to serve the proposed land use. 2. Sewer service for the site will require an improvement to LWSD’s sanitary sewer system of: a. feet of ” diameter sewer main or trunk to reach the site; and/or b. The construction of a sanitary sewer collection system on the site; and/or c. A major portion of LWSD’s comprehensive wastewater system plan would need to be implemented and/or constructed; and/or d. Other (describe): . 3. a. The existing sewer system is in conformance with LWSD’s Comprehensive Wastewater System Plan. b. The existing sewer system is not in conformance with LWSD’s Comprehensive Wastewater System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. a. The proposed site land use is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of sewer service outside of LWSD’s sewer service area. b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Sewer service is subject to: a. Payment of connection charges (to be determined by LWSD, for any new/modified service connection); b. Proof or reservation of easement(s) as required by LWSD; c. Other: LWSD Service Connection application required, for any new/modified service connection. Comments/special conditions: Care shall be taken to avoid encroachment upon existing LWSD water and/or sewer mains, and/or associated easement(s), on the site. I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR Signature: Brian Asbury (e-signed) Date: 11/3/2020 7204800172 7204800174 7204800186 wtr swr.docx (Form Update 3/13/20) Page 4 of 4