Loading...
20-103532 Building - Single Family City of Federal Way Permit #:20-103532-00-SF Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: A FRIENDLY HOME AFH Project Address: 2761 SW 312TH PL Parcel Number: 150320 0030 Project Description: Verification of Occupancy for Adult Family Home.***No construction work allowed under this permit.*** Owner Applicant Contractor Lender JAMES GICHURU MARY KAMAU 2761 SW 312TH PL 2761 SW 312TH PL FEDERAL WAY WA 98023 FEDERAL WAY WA 98023 Census Category:434-Residential alt/add -no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area(sq.ft.) Additional Permit Information Mechanical to be Included? No Is this an Online or O.T.C.application? Yes Plumbing to be Included? No sn ,�z» , atbayi.ps3 PERMIT EXPIRES Sunday, 14 March,2021 Permit Issued on Tuesday,September 15,2020 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: 7—/C-oi DA 0 Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References:2015 IRC Section R325(WAC 51-51) APPLICATION NUMBER:Q?0 `/03530t SECTIONS 1. 2. 3. AND4 MIJSTBE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED SECTION 1—PROPERTY INFORMATION SITE ADDRESS: 2761 SW 312th Pl., Federal Way, WA, 98023 ASSESSOR`STAXJPARCEL#: 150320 -0030 SECTION 2 -APPLICANT INFORMATION PROPERTY OWNER NAME: Mary Kamau/James GiChuru --- DAYTIME PHONE: 206-349-9538 AFH LICENSEE NAME(IFDIFFtRENT):_Mary__Kam&UDAYTIME PHONE: 206-349-9538 SECTION 3—FLOOR PLAN On a separate sheet of paper (8 1/2 x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms ( drooms) indicating which bedroom is: A, Ett C D, E and F. Label all components for exiing i.e., stairs, ramps, platforms, lifts and elevators. SECTION 4— DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys'fees incurred in the investigation of such claim), which may be made by any person,including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application. ,6ac NAME/TITLE: � elDATE: 9/6/2020 °PROPERTY OWNER ra APPLICANT 0 LICENSEE RECEIVED (Effective July 1,2013.) SEP 10 2020 Effective:2013 July 01 CITY OF FEDERAL WAY Updated:2017 February COMMUNITY DEVELOPMENT WAC 51-51-0325 Section R325—Adult family homes. SECTION R325 ADULT FAMILY HOMES R325.1 General.This section shall apply to all newly constructed adult family hones and all existing single family homes being converted to adult family homes. This section shall not apply to those adult family hones licensed by the state of Washington department of social and health services prior to July 1,2001. R325.2 Reserved. R325.3 Sleeping room classification.Each sleeping room in an adult family home shall be classified as: 1.Type S -Where the means of egress contains stairs,elevators or platform lifts. 2.Type NS1 -Where one means of egress is at grade level or a ramp constructed in accordance with R325.9 is provided. 3.Type NS2 -Where two means of egress are at grade level or ramps constructed in accordance with R325.9 are provided. R325.4 Types of locking devices and door activation. All bedroom and bathroom doors shall be openable from the outside when locked. Every closet shall be readily openable from the inside. Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist.Pocket doors shall have graspable hardw are available w hen in the closed or open position. The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum Required exit doors shall have no additional locking devices. Required exit door hardw are shall unlock inside and outside mechanisms w hen exiting the building allowing reentry into the adult family home without the use of a key, tool or special know ledge. R325.5 Smoke and carbon monoxide alarm requirements.All adult family homes shall be equipped with smoke and carbon monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the detection device warning is audible from all areas of the dwelling upon activation of a single alarm R325.6 Escape windows and doors.Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings w ill be approved as meeting this requirement. R325.7 Fire apparatus access roads and water supply for fire protection.Adult family homes shall be served by fire apparatus access roads and w ater supplies meeting the requirements of the local jurisdiction. R325.8 Grab bar general requirements.Where facilities are designated for use by adult family home clients, grab bars for ater closets, bathtubs and shower stalls shall be installed according to this section. Grab bar cross section.Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum and 2 inches maximum Grab bars with noncircular cross section shall have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4 5/8 inches maximum R:, ,% Grab bar installation.Grab bars shall have a spacing of 1 1/2 inches between the w all and the bar. Projecting objects, control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab bar shall have a clear space of 1 1/2 inches to the grab bar. EXCEPTION:Swing-up grab bars shall not be required to meet the 1 112 inch spacing requirement Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener,mounting device or supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering unit. Acrylic bars found in bathing units shall be removed. Foxed position grab bars,when mounted, shall not rotate, spin or move and have a graspable surface finish. R1:46.t1.; Grab bars at water closets.Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing-up bars.Grab bars shall meet the requirements of R325.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars, regardless of type used, shall be between 25 inches Effective:2013 July 01 Updated:2017 February rninirrjm and 30 inches maximus 8325.8.3.1 Fixed position grab bars.Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from the rear w all. 8325,8.3.2 Swing-up grab bars.Swing-up grab bars shall be a minimum of 28 inches in length from the rear wall. RN5.b.4 Grab bars at bathtubs.Horizontal and vertical grab bars shall meet the requirements of R325.8. R325.8.4.1 Vertical grab bars.Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and head end wall. Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub. The bottom end of the bar shall start betw een 36 inches and 42 inches above floor grade. EXCEPTION:The required vertical grab barcan be substituted with a floorto ceiling grab bar meeting the requirements of R325.8 at the control end and head end entry points. 8325.8.4.2 Horizontal grab bars.Horizontal grab bars shall be provided at the control end, head end, and the back w all w thin the bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. R3.25,6,6 Grab bars at shower stalls.Where show erstalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements of R325.8. EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab bars at the seat end wall.A vertical floor to ceiling grab bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. 8325.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end w all and head end wall.Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. 8325.8.5.2 Horizontal grab bars.Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent w ails.Horizontal grab bars shall not interfere with shower control valves. R325.9 Ramps.All interior and exterior ramps, w hen provided, shall be constructed in accordance with Section 8311.8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R -= i'3 t is not allowed for adult family homes. Handrails shall be installed in accordance w ith R. 11,32t,,£+ Handrails for ramps.Handrails shall be installed on both sides of rasps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with 8311.8.3.1 through R311.8.3.3. 8325.10 Stair treads and risers.Stair treads and risers shall be constructed in accordance with R,<I Handrails shall be installed in accordance with R R t.rs,_ Handrails far treads and risers.Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers.Handrails shall be installed in accordance with R.'.; through 8311.7.8.4 8325.11 Shower stalls.Where provided to ireet the requirements for bathing facilities, the minimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long. [Statutory Authority:RCW and chapters and 3 ROW.13-04-068,§51-51-0325,filed 2/1/13,effective 7/1/13.Statutory Authority:Chapter r t, ROW.10-18-036,§51-51-0325,filed 8/25/10,effective 9/25/10.Statutory Authority:ROW , '•'_ ;t i and chapters} 3 "`and " ROW.09-04-023,§51-51-0325,filed1/27/09,effective7/1/10.Statutory Authority:ROW ' °; :a.and chapters 1"i and 14 r ROW.07-01-090,§51-51-0325,filed 12/19/06,effective 7/1107.Statutory Authority:ROW .y and 1.2. ?r #.04- 01-109,§51.51-0325,filed 12117/03,effective 7/1/04.] Effective:2013 July 01 Updated:2017 February NAME OF AFH: A Fr i f h d l . .. _ /w `vt to A FN SECTION 5 MUSTBE COMPLETED BY THE BUI WING DfOARTMENTIN THEJURISDICTION THE HOME WI JIBE LOCATED. PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE UST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A Et CD E AND F AND CLASSIFICATION CODE S,NSI OR NS2. SECTION s—BUILDING INSPECTOR'S INSPECTION CHECKLIST R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R325.9 is provided to evacuate residents to public area. Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with 8325.9 are provided to evacuate residents to public area. SLEEPING ROOM A 0 Type S 0 Type NS2 Type N52 -- YES NO Closet door's are readily openable from the inside 10 Yes J No Smoke al arm is installed in the bedroom 0 0 Bedroom door opens easily and quicklyfrom the outside when locked 0 0 Sleepi ng room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;atIeast 20"wide) 0 0 EXCEPT per R310.2.1:at-grade escape windows—may have net clearance openings SF Sleeping room window has a maximum sill height of 44"a bovefloor to clear opening;no steps under window a llowec 0 0 SLEEPING ROOM B Ci Type S 10Type NS1 0 Type NS2 YES NO Closet door/s are readily openable from the inside 10 Yes 0 No Smoke alarm i si nstalled in the bedroom 0 Q Bedroom door opens easily and quickly from the outside when locked a Sleeping room window has a net opening of 5.7 SF(minimum dimensions a t l east 24"high;at l east 20"wide) EXCEPTper R310.2.1:at-grade escape windows—may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"a bovefloor to clear opening;no steps under window a llowec U 0 SLEEPING ROOM C 0 Type S JD Type NS1 JO Type NS2 YES NO Closet door/s are readily openable from the inside a Yes 0 No Smoke alarm is installed in the bedroom 0 0. Bedroom door opens easily and quickly from the outside when locked a a Sleeping room window has a net opening of 5.7SF(minimum dimensions at l east 24"high;at l east 20"wide) EXCEPT per R310.2.1:at-grade escape wi ndows—may have net cl earance opening 5 SF SI eepi ng room window has a maximum sill height of 44"a bovefl oor to clear opening;no steps under window a llowec a 0 SLEEPING ROOM D QType S ®Type NS1 JDType NS2 YES NO Closet door-is are readily openablefrom the inside a Yes 0 N Smoke alarm is installed in the bedroom 0 Bedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7SF(minimum dimensions atleast 24"high;at least 20"wide) EXCEPT per R310.2.1:at-grade escape windows—may have net clearance openings SF Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowec a a SLEEPING ROOM E gal Type 5 a Type NS1 ®Type NS2 YES NO Cl Closet door/s are readily openable from the inside Yes No Smoke al arm is installed in the bedroom 0 0 Bedroom door opens easily and quickly from the outside when locked a Sleeping room window has a net opening of 5.7 SF(mi nimum dimensions atleast24"high;at least 20"wide) 0 EXCEPT per R310.2.1:at-grade es cape wi ndows—may have net clearance opening 5 SF Sleeping room window has a maximum silheight of 44"abovefl oar to clear opening;no steps under window a llowec a a SLEEPING ROOM F No S 0Type NS1 0 Type NS2 YES NO Closetdoor/s are readilyopenablefromtheinside CI Yes No Smoke al arm is i nstalled inthe bedroom a a Bedroom door opens easily and quickly from the outside when locked El a_, Sleeping room window has a net opening of5.7SF(mi nimumdimensions atleast 24"high;at least 20"wide) 0 EXCEPT per R310.2.1:a t-grade es cape windows—may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"abovefloortoc€earopening;nostepsunderwindowallowec 0 Effective:2013 July 01 Updated:2017 February GENERAL NO YES Bathroom doors are easily and quickly openablefrom the outs ide when locked . 0 0 Carbon Monoxide alarms are installed as requiredin R315on each level of the home. Smoke a I a rms are installed on all levels of the dwelling,i n each resident sleeping room,outside each separate sleeping area in the immediate vicinity of sleeping rooms(R314). Smoke a nd Carbon Monoxide alarms are installed i ns uch a manner s otha tthe audible warning maybe heard i nail parts of the dwelling upon a ctivation of a single device. Access road and water supply meet Iocalfirejurisdictiona!requirements. R325.4 Operable parts ofdoor handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). Pocket doors shall have graspable hardwa re ava ilabie when in the closed or open position. 0 CI 8311.8 Ramps YES NO Inside Ramp NAA 0' m _0 .. 0 11311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception 8311.8.1 Not allowed in AFH) 0 R311.8.2 Landing Requirements:min.3X3 foot landing attop/bottom,where doors open onto ramps,and where rampchanges directions. 0 11325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1-R311.8.3.3. 0 0 Outside Ramp N/A CI YES NO 11311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 11311.8.2 Landing Requirements:min.3X3 foot landing attop/bottom,where doors open onto ramps,and where rampchanges directions. CI 0 R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1-11311.8.3.3. Guards below are depicted vertically as an example only.All Ramps must have Guards 0 0 f-Handrail both sides ---H I---- Less than 4" / 34"-38" i 1 c --. _! _ _-_ _ 1 t , 1 ' I "r'r , I- I -LIT1r 11 1 1 Guard I { ill i 1 �� 1--1-1 {fes - l_,- 1p. a ---- 36"min I , I) 1 , F i ' i ' i) I ill 1 I i � 1 1 is r I Ij ! i 1 ' jilI i E t1 f it 11 1 i` 1 ' 1 3'x II ,- s j i 1 landing 3'min E n 3x3 mm -- .. s-- _ 1 landing — -3'---- One unit vertical in twelve units horizontal 3' � minimum is an 8.3%slope all along surface of the ramp. minimum - 8311.2 Means of Egress YESNO R311.2 Door must be side-hinged with min.width of32 inches between face of door and stop.Height not less than 78 inches. 0 0 R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting ofthe wrist(lever-type). 0 R325.4 Required exit door hardware shall unlock insideand outside mechanisms when exitingthe building allowing re-entry CI 0 without use of key,tool or special knowledge. R31.1.7 Stairways WA( YES NO R311.7.5.1 Riser Height Max riser height shall be 7% inches(8 inches in structures builtprlortoJuly 1,2004) R311.7.5.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures builtprior to July 1,2004) R325.10.1 Handrails for Treads and Risers shall be installed on both sides oftreadsand risers numbering from one riser tom ultiple a a risers.Handrails shall be installed in accordance with 11311.7.8.1-R311.7.8.4 Effective:2013 July 01 Updated:2017 February R325.8 Grab Bars in Bathrooms N/A El YES NO Grab bars shall be installed for,ali water closets(toilets),bathtubs and showers accordingto R325.8. 0 0 Water Closets(tgilet)shallhavegrab bars installed on both sides accordingto R325.8—8325.8.3.1 or 8325,8.3.2. C]_.. Bathtubs shall have two vertical and three horizontal grab bars installed according to R325.8-R325.8.4-R325.8.4.2 0 0 Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower accordingto R325.8—R325.8.5— E3 0 R325.8.5.2. Shower stalls must be minimum size of30 inches deep by 48 inches long(R325.11) 0 0 AG103—AG105 Swimming Pool,Spa, Hot Tub • YES NO AF105.2 Must be surrounded by a barrier that is 48 inches high,may have doors and or gates that must have audible alarms when a a opened. AG105.5 EXCEPTION: Pools,Spas or Hot Tubs with a safety cover which complies with ASTM F 1346 0 0 0 PASSED CORRECTIONS REQUIRED PERMIT REQUIRED INSPECTOR'S NAME(PRINT) INSPECTOR'S SIGNATURE DATE: INSPECTOR'S OFFICE ADDRESS PHONE NUMBER: Application and inspection checklist developed by Washington Association of Building Officials(WABO),in cooperation with Department of Social and Health Services(DSHS)for use by both departments and licensors. 07/07/2013 Effective:2013 July 01 Updated:2017 February 1ii iiC JN1133W U 1 C: � i I I S f}t iHH ' U i (7--H-11j Tir..\\ ,,(-1 ' --4- 4 .9 I i u z Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References:2015 IRC Section R325(WAG 51-51) APPUCATION NUMBER:l''"i't) —/( - ,c%,,—. SECTIONS 1. 2. 3. AND4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED ` •.:.:: .,...:.Z...:.r "` � ' SN. ` � ' ' la ;t . . T + • aPROERV OA. ON s . ,? .• k SITEADDRESS: 2761 SW 312th PL, Federal Way, WA, 98023 ASSESSORSTAXIPARCEL# '150320 -0030 4, �. #'..r:_%.-;:, ;i. ��S.F��+ t^ S.�� 't a� a«..'. ,��� � "a"' z��� f.,• t�° ,�y,Y a .i_--4:-., :� 's' ,Jr t . 6. e.,$., - �. ^rsi` t t., xb"uya._ `'•+f•3 PROPERTY OWNER NAME: Maty_Kamau/James GichurU DAYTIME PHONE 206-349-95338 AFH UCENSEE NAME(IF oinze EWr):_Mary Kamau ___, DAYTIME PHONE: 206-349-9538 [ ,,;! " ; . :– . • SECTION 3 FLOOR PLAN On a separate sheet of paper (8 1/2 x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. SECTION 4 - DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct b the best of my knowledge,and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim(including costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person,including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurhdiction, Including its officers doCl employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application. NAME/TITLE; M.o97. --,477z4a ---------____— DATE: 9/6/2020 0 PROPERTY OWNER 0APPLICANT 0 LICENSEE (Effecti‘,e July 1,2013.) Effective:2013 July 01 Updated:2017 February WAC 51-51-0325 Section R325—Adult family homes SECTION R325 ADULT FAMILY HOMES R325.1 General.This section shall apply to all newly constructed adult family homes and all existing single family homes being converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington department of social and health services prior to July 1,2001. R325.2 Reserved. R325.3 Sleeping room classification.Each sleeping room in an adult family home shall be classified as: 1.Type S-Where the means of egress contains stairs,elevators or platform lifts. 2 Type NS1 -Where one means of egress is at grade level or a ramp constructed in accordance with R325.9 is provided. 3.Type NS2 -Where two means of egress are at grade level or ramps constructed in accordance with R325.9 are provided. R325.4 Types of locking devices and door activation. All bedroom and bathroom doors shall be openable from the outside w hen locked. Every closet shall be readily openable from the inside. Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist Pocket doors shall have graspable hardware available w hen in the closed or open position. The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum Required exit doors shall have no additional locking devices. Required exit door hardw are shall unlock inside and outside mechanisms w hen exiting the building allowing reentry into the adult family home without the use of a key, tool or special know ledge. R325.5 Smoke and carbon monoxide alarm requirements.All adult family hones shall be equipped with smoke and carbon monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the detection device warning is audible from all areas of the dwelling upon activation of a single alarm R325.6 Escape windows and doors.Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310. No alternatives to the sill height such as steps,raised platforms or other devices placed by the openings w ill be approved as meeting this requirement. R325.7 Fire apparatus access roads and water supply for fire protection.Adult family homes shall be served by fire apparatus access roads and water supplies meeting the requirements of the local jurisdiction R325.8 Grab bar general requirements_Where facilities are designated for use by adult family home clients, grab bars for water closets,bathtubs and show erstalls shall be installed according to this section. Rs: = .• Grab bar cross section.Grab bars with a circular cross section shall have an outside diameter of 1 114 inches minimum and 2 inches maximum Grab bars with noncircular cross section shall have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4 5/8 inches maximum Grab bar installation.Grab bars shall have a spacing of 1 1/2 inches between the w all and the bar. Projecting objects, control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab bar shall have a clear space of 1 1/2 inches to the grab bar. EXCEPTION:Swing-up grab bars shall not be required to meet the 1 112 inch spacing requirement Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener,mounting device or supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering unit.Acrylic bars found in bathing units shall be removed. Fixed position grab bars,when mounted, shall not rotate, spin or move and have a graspable surface finish. _i Grab bars at water closets,Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing-up bars.Grab bars shall meet the requirements of R325.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars,regardless of type used, shall be between 25 inches Effective:2013 July 01 Updated:2017 February minimum and 30 inches maxin-um. R325.8.3.1 Fixed position grab bars.Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from the rear wall. 8325.8.3.2 Swing-up grab bars.Swing-up grab bars shall be a minimum of 28 inches in length from the rear w all. R Grab bars at bathtubs,Horizontal and vertical grab bars shall meet the requirements of 8325,8. R325.8.4.1 Vertical grab bars.Vertical grab bars shall be a minimum of 18 inches long and installed at the control end w all and head end wall Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub The bottom end of the bar shall start between 36 inches and 42 inches above floor grade EXCEPTION:The required vertical grab barcan be substituted with a floorto ceiling grab bar meeting the requirements of R325.8 at the control end and head end entry points. R325.8.4.2 Horizontal grab bars.Horizontal grab bars shall be provided at the control end, head end, and the back w all within the bathtub area.Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. R Grab bars at shower stasis.Where shower stalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements of R325.8. EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horn ontal grab bars at the seat end wall.A vertical floor to ceiling grab bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. R325.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end w all and head end wall.Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. R325.8.5.2 Horizontal grab bars.Horizontal grab bars shall be installed on all sides of the shower stall mounted between33 inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls.Horizontal grab bars shall not interfere with shower control valves R325.9 Ramps.All interior and exterior ramps, when provided, shall be constructed in accordance with Section R311 8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R i = 1 is not allowed for adult family homes. Handrails shall be installed in accordance w ih R • R Handrails for ramps.Handrails shall be instated on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311 8.3.3. R325.10 Stair treads and risers.Stair treads and ricers shall be constructed in accordance with R r- r a. Handrails shall be installed in accordance withR R aa Handrails for treads and risers.Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers.Handrails shall be installed in accordance with R through R311.7.8.4 R325.11 Shower s tails.Where provided to meet the requirements for bathing facilities, the rilnimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long. [Statutory Authority_RCW! ;' ,and chapters:!, and . :.RCW.13-04-068,§51-51-0325,filed 2/1113,effective 7/1113.Statutory Authority:Chapter I., ,RCW.10-18.036,§51-51-0325,filed 8/2`J'I O,effertfve9/26/10.Statutory Authodiy:RCW • E .r a 5. <, ,a and chapters..a and 'c r ' RCW.09-04-023,§51-51-0325,filed 1/27/09,offne.hve7/1110,Statutory Authority;RCW -1,and chapters r., 't and RCW.07-01-090,§51-51-0325,filed 12119/06,effective 7/1107,Statutory Authority;RCW i; : ; +:;and t , . a. ;.04- 01-109,§51-51-0325,filed 12/17/03,effective 7/1/04.] Effective:2013 July 01 Updated:2017 February NAME OF AFH: A Fr; ; -/ /+.* /!U Ii1 7 e ��f-i SECTION 5MUSTBE COMPLETED BY TI-IF BUILDING DEPARTMENT IN THEJURISDICTION'IHE HOME WILL BE LOCATED. PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANTS FLOOR PLAN—USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A B CD E AND F AND CLASSIFICATION CODE 5,NS1 OR NS2. ' f l''1-- ' SECTION`S°=-BUJ WING:'INSPECfOR'S lNSPEtTION `8ECKLIST ; ' R325.3 Sleeping Room Classdicetion: Each sleeping room in an Adult family Home shall be classified as: Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R325 9 is provided to evacuate residents to public area. Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with 8325.9 are provided to evacuate residents to public area. SLEEPING ROOM A !❑Type S Type NS1 ❑Type NS2 YES NO Cl osetdoor/s are readily openablefrom the inside aYes 11:1 No —1 Smoke alarm is installed in the bedroom 0 Bedroom door opens easily and quicklyfrom the outside when locked :S 0 Sleeping room window has a netopening of 5.7 SF(minimum dimensions at l east 24"Irigh;at(east 2.0"wide) iz, 0 EXCEPT per R310.2.1:at-grade escape wi ndows–may have net clearance openings SF Slee.ing room wi ndow has a maximum sill height 0144"a bove fl oor to clear ope.p.ipg;i g_no steps under window a!lower Ilif 0 SLEEPING ROOM B ❑Type SType NS1Type NS2 YES NO Ciosetdoor/s are readily openablefromthe insidelrlYes 13 No Smokealarm isinstalled inthe hedrnom ,B[' 0 Bedroom door opens easily and quicklyfrom the outside when locked .A ® Sleeping room window has a netopening of 5.7 SF(minimum dimensions at least 24"high;atIeast20"wide) ,_ 0 EXCEPTper R310.2.1:at-grade escape windows–may have net clearance opening SF SI eepi ng room window has a maximum sill height of 44'abovefloor to clear opening;no steps under window a llowecA SLEEPING ROOM C OType S W-.Type NS1 10 Type NS2 YES NO Clos_etdoor/s a rereadilyopenablefrom the inside 1a-Yes 10 No _Leaarmbedroom io' Smoklisinstalledinthe _❑_ Bedroom door opens easily and quickly from theouts idewhen locked 0 Sleeping room window has a netopening of 5.7SF(minimum dimensions at least 24"high;at least 20"wi de) 0 EXCEPT per R310.2.1:at-grade escape wi ndows–may have net clearance opening 5 SF Sleeping room window has a maximum sill heightof44"abovefloortoclearope ing;no steps under window allower.0 _ 0 SLEEPING ROOM D 10 Type S clear NS1 1Q Type NS2 YES NO i Ciosetdoor/s are readily openable from the inside 0 Yes Ci No I Smoke alarm is installed in the bedroom /5- ❑ Bedroom door opertseasily and quickly from the outs idewhen locked Ji 0 Sleeping room window has a netopening of 5.7SF(minimum dimensions atleast 24"high;at least 20"wide) SI 0 EXCEPT per R310.2.1:at-grade escape windows–may have net c learance open ing 5 SF Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window a llowec -r 1 SLEEPING ROOM E 0 Type S .I Type NS1 ❑Type NS2 YES NO Closet door/s are readily openable from the inside $.Yes 0N Smoke al arm is installed in the bedroom 0 0 Bedroom door opens easily and quicklyfrom the outside when locked ,®, 0 Sleeping room window has a net opening of 5.7SF(minimum dimensions atleast 24"high;atleast20"wide) J:k 0 EXCEPT per R310.2.1:at-grade escape windows–may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under windowallowec,5- 0 SLEEPING ROOM F d Type S 1 Type NS1 1n Type NS2 YES NO Closet door/s are readily openable from the inside UR Yes No Smoke alarm is installed in the bedroom ❑ _ _ Bedroom door opens easily and quickly from the outside when locked .130 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ,IEL 0 EXCEPTper R310.2.1:at-grade es cape windows–may have netclearance opening 5 SF Sleeping room window has a maximum sill height of 44"a bovefloor to clear opening;no steps under window allowec tr Effective:2013 July 01 Updated:2017 February GENERAL YES NO Bathroom doors are easily and quickly openable from the outside when locked .iir , 0 Carbon Monoxide alarms a re installed as required i n R315 on each level of the home. — Pk 0 Smoke al arms are installed on all levels of the dwelling,i n each residents leeping room,outside each separate sleeping area in the i mmediatevicinity of sleeping rooms(R314). A 0 Smoke and Carbon Monoxide alarms are installed i ns uch a manner sothatthe audible wa ming may be heard in a ll El of the dwelling upon activation of a single device. Access road and water supply meet I ocalfi re j urisdictional requirements. 0 R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). r 0 Pocket doors shall have graspable horilwareavailahlewhen in the closed or open position. fir R311.8 Ramps YES NO Inside Ramp NiAill 0 0 R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8 3%slope).(Exception R.i11.8.1 Not allowed in AFH) ❑ 0 R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doors open onto ramps,and where ramp changes directions. 0 0 R325.9.1 Handrails required on both sides of ramp in accordancewith R311.8.3.1–R311.8.3.3. 0 0 Outside Ramp N/A 0 I YES NO R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8,3%slope).(Exception R311.8.1 Not allowed in AFH) .I 0 R311.8 2 Landing Requirements:min.3X3 foot landing attop/bottom,where doors open onto ramps,and where ram p cha nges ❑ directions. –21 R325.9.1 Handrails required on both sides of ramp in accordance with 8311.8.3.1–R311.8.3.3. Al 0 Guards bel ow are depicted vertically as an example only.All Ramps must have Guards A 0 -Handrail both sides – Less than 4" i 34"-38" j it I �" 1 I • � -� -rl i I L Guard ( I l I I I i { '! ! I + 'iC,.41I '' i " ! IL 1_ r i 1-- 36"min I i I ( ill j I �� I I t i i ( l i�. l . -I---circ Ic i ri, . 1 I -i r i_r I, • ll' 3'x 3'min ' -,.7 C,tc a w r r_�'-; r i-,- I Al ' 1 landing 3'x3'min i ,-: , ,_r. i II 1 1 ' landing L`_ " I– 3' –One unit vertical in twelve units horizontal k --- 3'---..-I minimum is an 8.3%slope all along surface of the ramp. minimum R311.2 Means of Egress YES NO R3112 Door must be side-hinged with min.width of32 inches between face ofdoor and stop.Height not less than 78 inches. rz 0 R325-4 Operable parts ofdoor handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand 7' and shall not require tight grasping pinchingor twistingofthe wrist(lever-type). XI 0 R325.4 Required exit door hardwareshallunlockinsideandoutsidemechanismswhenexitingthebuildingallowingre-entry ❑_ without use of key,tool or special knowledge. _ 8311,7 Stairways N/A YES„ NO R311.7.5.1 Riser Height: x riser height shall be 7 Y.inches(8 inches in structures built prior toluly 1,2004) 0 0 R311.7.52 Tread Depth:Min.tread depth shall be in 10 inches(9 inches In structures built prior to July 1,2004) 0 1:1— R325.10.1 R325.10.1 Handrails forTreads and Risers shall be installed on both sides oftreads and risersnumberingfrom one riser tom ultiple ❑ ❑ risers.Handrails shall be installed in accordance with R311.7.8.1–R311.7.8.4 Effective:2013 July 01 Updated:2017 February R325.8 Grab Bars in Bathroonl YES NO Grab bars shall be installed for,alI water closets(toilets),bathtubs and showers according to R325.8. Cif Q Water Closets(toilet)shall have grab bars installed on both sides accordingto R325.8—R325.8.3.1 or R325,8.3.2. a Bathtubs shall have two vertical and three horizontal grab bars installed accordingto R325.8-R325,$A—R325.8.4.2 Er—_ b— Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower accordingto R325.8—R325.8.5— ET 0 R325.8.5.2. r-1 Shower stalls must be minimum size of 30 inches sleep by 48 in Is s I g(R325.11) AG103—AG105 Swimming Pool,Spa, Hot Tub • YES NO AF105.2 Must be surrounded by a barrier that is 48 inches high a have doors and or gates that must have audible alarms when a a opened. —p� --�� AG105.5 EXCEPTION; Pools,Spas or Hat Tubs with e safety cover which complies with ASTM F t 346 IV ci PASSED Q CORRECTIONS REQUIRED 0 PERMIT REQUIRED INSPECTOR'S NAM 'PRINT I fSPECTO• 'SIGN• s'TE: IN _33 25-- /4 /Cue" 5 - .50 72- SPECTOR'S OFFICE ADDRESS / PHONE NUMBER: Application and inspection checklist developed by Washington Association of Building Officials(WABO),in cooperation with Department of Social and Health Services(DSHS)for use by both departments and licensors, 07/01/2013 Effective:2013 July 01 Updated:2017 February 33Yld ONI133W I., I . 3 j r . ..\\....: • la 1 .1. r `�' \ l ' I `-....- C Gas— -1 , .f.) , I _ 1 ry — .. t-1tl,tivtu SEP 10 2020 PERMIT APPLICATION On'OF Federal CITY OF FEDERAL HJ�I�ERMIT CENTER+ 33325 8th Avenue South + Federal Way,'WA 98003-6325 COMMUNITY O Lf�MENT253-835 2607 + FAX 253 835 2609 + permitcenter(�r,;.cityoffederalway.com PERMIT NUMBER a 0— 0 5 - S l I 3 J V` TARGET DATE SITE ADDRESS SUITE/UNIT# 2761 SW 312th PI., Federal Way, WA, 98023 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ 1 5 0 3 2 0 - 0 0 3 Q 4,800.00 TYPE OF PERMIT BUILDING D PLUMBING ❑ MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION • NAME OF PROJECT A Friendly Home Adult Family Home Removed carpets throughout the house;re ed flooring and installed laminate. Refreshed paint throughout. PROJECT DESCRIPTION Detailed description of work to Installed larger interior door ] y\ %, p tC . Af H be included on this permit only Installed new ele panel and service.Permit#6620 102117 tb_0 EL Poured c crete path and refreshed outside patio. NAME PRIMARY PHONE James Gichuru&Mary Kamau 206-349-9538 PROPERTY OWNER MAILING ADDRESS E-MAIL 2761 SW 312th Pl. marykamau.2000@gmail.com CITY STATE ZIP Federal Way WA 98023 NAME - PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE# • EXPIRATION DATE UBI# SELF � NAME PRIMARY PHONE Mary Kamau 206-349-9538 APPLICANT MAILING ADDRESS E-MAIL 2761 SW 312th PI. marykamau.2000@gmail.com CITY STATE ZIP FAX Federal Way WA 98023 NAME PRIMARY PHONE PROJECT CONTACT Mary Kamau 206-349-9538 (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 2761 SW 312th PI. marykamau.2000@gmail.com concerning this application) CITY STATE ZIP FAX Federal Way WA 98023 NAME PROJECT FINANCING 0 OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied /to Rhee city as a part of this application. SIGNATURE: hU� �LIY/'�4!/1 DATE 9/10/2020 PRINT NAME: Mary Wairimu Kamau Bulletin#100—February 19,2020 Page 1 of 2 k:\Handouts\Permit Application