18-105861 ♦ f
•
Building - Commercial
Community Development r ' Permit #:18-105861-00-CO
33325 8th Ave S
Federal Way,WA 98003
FILE Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax:(253)835.2609
Project Name: SOUTH KING FIRE&RESCUE-STATION 60
Project Address: 35100 PACIFIC HWY S Parcel Number:202104 9148
Project Description: ADD-Construction of a 1900 square foot addition and interior renovations,including
plumbing and mechanical. Also includes associated site improvements.
Owner Applicant Contractor Lender
DAVE MATAFTINSOUTH KING ED MCMANAMNARICE FERGUS WESTERN VENTURES CONST OWNER IS LENDER
FIRE AND RESCUE MILLER,LLC INC
31617 1ST AVE S 262 4TH ST PO BOX 298
FEDERAL WAY WA 98003 BREMERTON WA 98370 )UNTLAKE TERRACE WA 98043-0:
•
Census Category:437-Commercial alt/add/conversion
Includes: #1 #2 #3 #4
Occupancy Class: B
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 6,142.00
Additional Permit Information
Occupancy#1-Area(Sq.Feet) 6142 Occupancy#1-Construction Type Type V-B
Mechanical to be Included" Yes Plumbing Work Valuation" 85000
Mechanical Work Valuation? 190000 Number of Stories 1
Is this an Online or O.T.C.application" No Permit for Building Shell Only" No
Plumbing to be Included? Yes Occupancy#1-Use Fire/Police Station
Comprehensive Plan Designation Commercial Enterprise Zoning Designation CE
Total Valuation:2,094,566.00
, - ed s
1,4514`44
ionai
?'r . ,x �����§ ,�.�. titre'ate,. a �:S, r ;i � », � ��� -,zoo
Air Handling Units 3 Ducting 1 Fans 11
Furnaces 3 Gas Piping 1 Gas Pipe Outlets 4
Hot Water Tanks 1 Refrigeration Systems 1
; s b ! a g
Dishwashers 1 Drains 1 Laundry Washer Outlets 1
Lavatories 2 Other Plumbing Fixtures 1 Showers 1
Sinks 2 Urinals 1 Water Closets 2
Hose Bibbs 5
CONDITIONS:
Building 2 will require an NFPA 13 Fire Sprinkler system
Building 2 will require a fire alarm system
PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITIES,an on-site preconstruction
meeting shall be held with the Public Works Inspector,to go over the Temporary Erosion and Sediment
Control measures.Contact George Hauser,inspector at(253)835-2741 to schedule the meeting.Please
give a minimum of 48 hours notice,prior to the meeting.
a.
•
PERMIT EXPIRES Sunday,24 November,2019
Permit Issued on Tuesday,May 28,2019
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way. 11
Owner or agent: �` �%+nT ed- Date: a 13 1 )9
THIS CARD IS TO REMAIN ON-SITE
CITY Cel,
Construction Inspection Record
Federal Way INSPECTION REQUESTS: (253)835-3050
PERMIT#: 18 105861 00 Address: 35100 PACIFIC HWY S
Project: DAVE MATAFTIN FEDERAL WAY WA 98003-8318
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
a .. .' V
. ® Initial Erosion Control(4365) 11=1 Footings/Setback(4110) • 0 Foundation Wall(4115)
To be done PRIOR to breaking ground ft Approved to place concrete Approved to place concrete
9
By Date By Date By Date
0 Drainage/Downspout(4040) 0 p Re-steel(4215) 0 Plumbing Groundwork(4190)
Approved to backfill 1 Approved to place concrete or groutApproved to cover
By Date
® Slab/Concrete Floor(4255) ® Underfloor Framing(4285) El Floor Sheathing(4105)
Approved to place concrete Approved to sheath floor Approved to install flooring
By ; Date 9 • - By Date By Date
1:1 Shear Walls(4245) El Roof Sheathing(4220) CI Rough Plumbing(4230)
Approved to install siding Approved to install roofing Approved
Byes Datet0
o tO By 4 ) Date )i��,/l9 By f ti Date 12/0l/1
^�s Mechanical R ugh-in(4165) ElGas Piping(4125) •® Fire/Draft Stops(4095)
Approved Approved to release test Approved
By Date ••By AO Date IL I 1s1 Si By Date
16 Interim Erosion Control(4370) Prior to scheduling a Framing inspection; ..17 Framing(4120)
Approved Electrical,Plumbing&Mechanical Rough-in
Approved to insulate
and Fire/Draft Stop inspections must be signed-
off and approved. IBC 109.3.4 By Date
•
1: pp 1 Insulation(4150) 1=I Gypsum Wallboard Nailing(4130) El Suspended Ceiling Grid(4265)
Approved to install wallboard PP Approved to install mud&tape Approved to drop tile
By Date By ii Date 2- 12. By Date
El Final-S K F&R(4060) El Final-Planning El Final-Public Works(4080)
Approved Approved Approved
By Date . By Date ' By Date
•
1:1 Final Erosion Control(4375) El Final-Mechanical(4065) ® Final-Plumbing(4075)
Approved }AtrApproved A �1 Approved
.By Date •�By �� tr
Date 7.420.4)0 „By 0 Date 773.20 .
CI Final-Building(4050)
PApproved
By Arles Date 9.20,az)
0 Rough Electrical 0 Final Electrical ID Right of Way
Approved Approved Approved
By Date By Date By Date
1
V
y at
' 1. 0
4 ,
L.
Lt 1
A , k ..i 'A
14. •
•
c
A C) 1 1 '" ''' .
N
e—, \ ® eNi M
f
RECEIVED
Ti DEC 13 2018
WATER &SEWER DISTRICT CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
Lakehaven Water & Sewer District - Development Engineering Section
31623 - 1st Ave S * PO Box 4249 • Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: ❑ Building Permit-SFR ❑ Building Permit-MFR ® Building Permit-Other
❑ Subdivision 0 Short Subdivision 0 Binding Site Plan
❑ Rezone ❑ Boundary Line Adjustment
❑ Other(specify/describe)
Tax Parcel Number(s): 2021049059/2021049148 Site Address: 1351 S 351st St/ 35100 Pacific Hwy. S
Ex. Bldg. Area to Remain: 5.964+1- (9059) / 14,678+/- sf(91481 New Bldg. Area Proposed: 7,952+/-sf(9059, w/add'n)
Applicant's Name: SKF&R Lakehaven GIS Grid: 3-12
SEWER SYSTEM INFORMATION
1. ® Sewer service can be provided by service connection to an existing 10" diameter sewer main that is approximately 20+/-
feet from the site and the sewer system has the capacity to serve the proposed land use.
2. 0 Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of:
❑ a. feet of "diameter sewer main or trunk to reach the site; and/or
❑ b. The construction of a sanitary sewer collection system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or
constructed; and/or
❑ d. Other (describe):
3. ® a. The existing sewer system is in conformance with Lakehaven's Comprehensive Wastewater System Plan.
❑ b. The existing sewer system is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an
Amendment to this Plan will be required.This may cause a delay in issuance of land use approvals or permits.
4. ® a. The proposed site land use is within the corporate limits of Lakehaven Water&Sewer District, or has been granted
Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Sewer service is subject to:
® a. Payment of connection charges (to be determined by Lakehaven, for any new/modified service connection);
® b. Proof or reservation of easement(s) as required by Lakehaven;
® c. Other: Sewer Service Connection Permit required, for any new/modified service connection.
Comments/special conditions: The property/site has three (3) existing sewer service connections.
I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISQR
/il/
Signature: iv.� Date: ` 2-7/0//
PERMIT #: 18-105861-00-CO
ADDRESS: 35100 Pacific Highway S
PROJECT: Facility Improvements
SOUTH KING FIRE AND RESCUE#60
DATE: 12/13/2018
2021049059 2021049148 swr.docx (Form Update 1/3/17) Page 1 of 2
.
/2021049027 2021049155
35050
CO
2021049162
35000
2021049043 VL
35060
.;4 ' p
P
Or 4
10"p VC
BS t
%.1o.
ti
2021049059
1 ;' 1351
2021049148
0 35100
/a
or
r ti°
1
I
1
1
t
S 352ND Sr
P
2921049053
2921049048 35206
35200 2921049048 2921049002
35204 1200
•
440TE: Lakehaven Water and Sewer Certificate of Sewer Availability
District nether warrants nor guarantees Parcels 2021049059& 2021049148
the accuracy of any facility information 0 100 100
provided.Facility locations and conditions
are subject to field verification.
Fee 12/12/2018 BIA
2021049059 2021049148 swr.docx (Form Update 1/3/17) Page 2 of 2
RECi1VED
• FILEDEC 13 2018
to Lakehaven CI1Y OF FEDERAL WAY
WATER & SEWER DISTRICT COMMUNITY DEVELOPMENT
Lakehaven Water &Sewer District - Development Engineering Section
31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: 0 Building Permit-SFR 0 Building Permit-MFR ® Building Permit-Other
0 Subdivision ❑ Short Subdivision 0 Binding Site Plan
❑ Rezone 0 Boundary Line Adjustment
❑ Other(specify/describe)
Tax Parcel Number(s): 2021049059/2021049148 Site Address: 1351 S 351st St/ 35100 Pacific Hwy. S
Ex. Bldg. Area to Remain: 5,964+/- (9059) / 14,678+/- sf(9148) New Bldg. Area Proposed: 7,952+/- sf(9059, w/add'n)
Applicant's Name: SKF&R Lakehaven GIS Grid: J-12
WATER SYSTEM INFORMATION
1. ® Water service can be provided by service connection to either an existing 6" diameter water main that is approximately
30+/- feet from the site or an existing 8"diameter water main that is on parcel 2021049148.
2. 0 Water service for the site will require an improvement to Lakehaven's water distribution system of:
❑ a. feet of "diameter water main to reach the site; and/or
❑ b. The construction of a water distribution system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be implemented and/or
constructed; and/or
❑ d. Other(describe):
3. ® a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan.
❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an
Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits.
4. to a. The subject property is within the corporate limits of Lakehaven Water&Sewer District, or has been granted
Boundary Review Board approval for extension of water service outside of Lakehaven's water service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Water service is subject to:
® a. Payment of connection charges (to be determined by Lakehaven, for any new/modified service connection);
® b. Proof or reservation of easement(s)as required by Lakehaven;
® c. Other: The existing 1"meter for parcel 2021049059 should be evaluated under UPC&Lakehaven standards, to
determine if it's adequate for the proposed use.
Comments/special conditions: Service pressures greater than 80 psi indicated, Pressure Reducing Valves indicated, contact local
building official for requirements 8t/or additional information.
The nearest fire hydrant is on parcel 2021049148 (as marked on map on the back of this page).
Fire Flow at no less than 20 psi available within the water distribution system is a minimum 1,000 GPM for two (2) hours or more.
This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates
greater than this may be accommodated .through water distribution system improvements, contact Lakehaven for additional
information.
538 Pressure Zone Est. Meter Elevation(s)-GIS: High 254+/-, Low 247+/- Est. Pressure Range at Meter(s) (psi): Min. 114, Max. 126
I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
Signature: �. dr I Date: 217- 1/
PERMIT #: 18-105861-00-CO
ADDRESS: 35100 Pacific Highway S
2021049059 2021049148 wtr.docx (Form Update 10/24/1 PROJECT: Facility Improvements 1 of 2
SOUTH KING FIRE AND RESCUE#60
DATE: 12/13/2018
1
/ .
•
2021049027
1028
2021049155
35050
r 6?
4, .. a, 2021049182
35000
Ai
Ac if"
2021049043 ',
35060 �1r illh
i. ,, ,"
f '" .
•
t
i r. • „
l • I
rt CI
df
41, 0 •I•i r
le Q 8”bt
n Ex. WtrSvc 3553
Ex. WtrSvc 23121 h 1" Qom.
I M O
Are.. 6" re. Prot. 5 am
li 2021049059
Ex. : '" 1351
',1' 2021049148 Hydrant. ai
35100
I
a'
4
S 352ND ST
2921049053
2921049045 35206
35200 2921049048 2921049002
35204 1200
• .
lI0TE: Lakehaven Water and Sewer Certificate of Water Availability M
District nether warrants nor guarantees Parcels 20 21 04 9059& 2021049148
the accuracy of any facility information a ia4 210
provided.Facility locations and conditions
11111
are subject tofieldverification. wee 12/12f2018 BIA
2021049059 2021049148 wtr.docx (Form Update 10/24/18) Page 2 of 2
CITY OF FEDERAL WAY
Temporary Certificate of Occupancy
This temporary certificate is issued pursuant to the requirements of International Building Code, Section 110.3.
Tenant name: SOUTH KING FIRE & RESCUE STATION 60
Owner Name: SOUTH KING FIRE & RESCUE
Site Address: 35100 Pacific Hwy S
Permit number: 18-105861
Occupancy Class: B, S-1
Construction Type: V-B
75D,
ott Sproul, Building Officialto
This TEMPORARY CERTIFICATE OF OCCUPANCY expires on September 7, 2020
. 411Ilk,
RECEIVED
_„„,,,,,..4..., PERMIT APPLICATION
CITY OF DEC f 2018' p
• Federal Way PERMIT CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325
253-835-2607+FAX 253-835-2609+nermitcenteta,cityoffederalway.com
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
PERMIT NUMBER I S _ / d 5 8 to I - G U
TARGET DATE
SITE ADDRESS SUITE/UNIT#
35100 Pacific Highway South, Federal Way, WA 98003 Building 2
PROJECT VALUATION ZONING ASSESSORS TAX6PARCEk# 1 0 4 9 1 4 8 and
$ 2,094,566 CE - _0 _2 -
TYPE OF PERMIT ® BUILDING PLUMBING MECHANICAL ❑ DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION
NAME OF PROJECT South King Fire and Rescue Facility Improvements - Fire Station 60
Site area 2.35 acres with (2)Construction Type VB existing buildings on site.
PROJECT DESCRIPTION Building 2:Vehicle maintenance shop: interior remodel with 1,900 sf addition. Includes mechanical
Detailed description of work to andlu bin im ove ents,drafting P;t, stormwy�ter improvements.
i;
Vr11hfee.ry1t44Orfiffrll
NAME PRIMARY PHONE
King County Fire District#39-South King Fire and Rescue 253-839-6234
PROPERTY OWNER MAILING ADDRESS E-MAIL
31617 1st Avenue South dave.mataftin@southkingfire.org
CITY STATE ZIP
Federal Way WA 98003
NAME PHONE
TBD
MAILING ADDRESS E-MAIL
CONTRACTOR
CITY STATE ZIP FAX
WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE#
/ /
Nice Fergus Miller. Inc,Attn: Ed McManamna P360-362 1427
APPLICANT MAILING ADDRESS E-MAIL
275 5th Street, Suite 100 emcmanamna@rfmarch.com
CITY STATE ZIP FAX
Bremerton WA 98337
NAME PRIMARY PHONE
PROJECT CONTACT Ed McManamna
(The individual to receive and MAILING ADDRESS EMAIL
respond to all correspondence 275 5th Street,Suite 100
concerning this application) CITY STATE ZIP FAX
Bremerton WA 98337
NAME
PROJECT FINANCING IX] OWNER-FINANCED
When value is$5,000 or more •MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RCW 19.27.095)
I certify under penalty of perjury that I am the property owner or authorised agent of the property owner.I cert(ly that to the best
of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit. I understand that the
issuance of this permit does not remove e owner's responsibility for compliance with local, state, or federal laws regulating
construction or enviro ental laws. 7 1
I further agree to • d harmless the _ I.f Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in
the investigation and • I, ease of such cl• , hich may be made by any person, including the undersigned,and filed against the city,
but only where such c�•im arises •ut • th reliance of the city, including its officers and employees, upon the accuracy of the
information supplied • 1 ci is • •plication.
ippir"
SIGNATURE: _ ‘ _1_�Ldl DATE 12-1 3-t v
PRINT NAME: 1W
Bulletin#100—January 29,2016 Page 1 of 2 k:\Handouts\Permit Application
•
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT $ io-
Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe)
AIR CONDITIONER FIREPLACE INSERTS HOODS icoo,m,erdat)
BOILERS FURNACES 1 HOT WATER TANKS(cas)
COMPRESSORS GAS LOG SETS 1 REFRIGERATION SYST
DUCTING GAS PIPING WOODSTOVES
VALUE OF PLUMBING WORK
PLUMBING PERMIT $
Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
BATHTUBS(or Tub/Shower combo LAVS(Hand Sinks) 2 TOILETS 1 WATER PIPING
11 DISHWASHERS RAINWATER SYSTEMS 1 URINALS 1 OTHER(Describe)
E DRAINS ) SHOWERS VACUUM BREAKERS `, W^>
DRINKING FOUNTAINS 2 SINKS(Kachen/UtIbtyl WATER HEATERS(Eieomo
HOSE BIBBS SUMPS 1 WASHING MACHINES 18 TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
None Lakehaven Lakehaven
EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM?
Vehicle Storage/Shop 102,366 ❑Yes® No ®Yes 0 No
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
BASEMENT
FIRST FLOOR(or Mobile Home)
SECOND FLOOR
COVERED ENTRY
DECK
GARAGE ❑ CARPORT ❑
OTHER(describe)
Area Totals EXISTING PROPOSED TOTAL
**PIETY IJOfIfEB 0111LY**
ESTIMATED SELLING PRICE$ 4t OF BEDROOMS
COM MERCIAL—NEW/ADDITION
AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information
Square Feet Type Stories
NEW BUILDING '
ADDITION 1,988 S1 5B 1
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information
Square Feet Type Stories
TOTAL BUILDING 6,142 B,S1 5B 1
TENANT AREA ONLY
PROJECT AREA ONLY
Bulletin#100—January 29,2016 Page 2 of 2 k:\Handouts\Permit Application