7 Village Green Campus Irrigation Plan East L3.11ST AVE S
,
IRRIGATION CONTROLLER
A. EXTERIOR WALL
-
1
MOUNT IRRIGATION:'
CONTROLLER.
LOCATION TO BE
DETERMINED BY Q�NEI�:
i
IRRIGATION POINT 1
/
OF CONNECTION @
EXISTING 1" METER L3:3
1
_
e
x
I--
tt
A
7,
i
w
W
s'
A w
B1
MAINLINE, LATERAL LINES, AND VALVES SHOWN
A
'
„
SCHEMATICALLY.'LOCATE WITHIN LANDSCAPE 'AREAS, 'TYP.`
a -
,
, _
/;
IRRIGATION HEAD SCHEDULE
SYM.
CATALOG NUMBER
COLOR
RADIUS
GPM
PSI
HUNTER MP ROTATOR HEADS
PROS-06-PRS40-CV-R-
(ALL SPRAY BODIES)
v
PRS40-CV-R-MP-CORNER
TURQUOISE
8
0.12
40
n
PRS40-CV-R-MP1000-900
MAROON
8
0.15
40
o
PRS40-CV-R-MP1000-900
MAROON
8
0.23
40
o
PRS40-CV-R-MP1000-900
MAROON
8
0.30
40
p
PRS40-CV-R-MP1000-2100
LIGHT BLUE
8
0.37
40
4}
PRS40-CV-R-MP1000-210°
LIGHT BLUE
8
0.45
40
p
PRS40-CV-R-MP1000-360-
OLIVE
8
0.60
40
PRS40-CV-R-MP-CORNER
TURQUOISE
10
0.13
40
m
PRS40-CV-R-MP1000-900
MAROON
10
0.16
40
m
PRS40-CV-R-MP1000-900
MAROON
10
0.25
40
m
PRS40-CV-R-MP1000-900
MAROON
10
0,31
40
6:�
PRS40-CV-R-MP1000-2100
LIGHT BLUE
10
0,38
40
Q}
PRS40-CV-R-MP1000-210-
LIGHT BLUE
10
0,47
40
m
PRS40-CV-R-MP1000-360-
OLIVE
10
0.63
40
4
PRS40-CV-R-MP-CORNER
TURQUOISE
12
0.15
40
a
PRS40-CV-R-MP1000-900
MAROON
12
0.16
40
o
PRS40-CV-R-MP1000-900
MAROON
12
0.25
40
v
PRS40-CV-R-MP1000-900
MAROON
12
0.32
40
Pk
PRS40-CV-R-MP1000-210"
LIGHT BLUE
12
0.41
40
q
PRS40-CV-R-MP1000-2100
LIGHT BLUE
12
0.48
40
4
PRS40-CV-R-MP1000-360-
OLIVE
12
0.65
40
A
PRS40-CV-R-MP-CORNER
TURQUOISE
15
0.19
40
k
PRS40-CV-R-MP1000-900
MAROON
15
0,21
40
•
PRS40-CV-R-MP1000-900
MAROON
15
0.30
40
•
PRS40-CV-R-MP1000-900
MAROON
15
0.37
40
ok
PRS40-CV-R-MP1000-2100
LIGHT BLUE
15
0.43
40
1
PRS40-CV-R-MP1000-2100
LIGHT BLUE
15
0.57
40
®
PRS40-CV-R-MP1000-3600
OLIVE
15
0.75
40
m
PRS40-CV-R-MPLS515
IVORY
5X15
0.22
40
m
PRS40-CV-R-MPRS515
COPPER
5X15
0.22
40
cip
PRS40-CV-R-MPSS530
BROWN
5X30
0,22
40
HUNTER BUBBLER NOZZLES-
NOZZLE
RADIUS
GPM
PSI
+
PRS40-CV-R-MSBN-20F
NA
3
2.0
40
PRS40-CV-R-MSBN-10H
NA
3
1.0
40
a
PRS40-CV-R-MSBN-50Q
NA
3
0.5
40
HUNTER MP ROTATOR HEADS
NOZZLE
RADIUS
GPM
PSI
Q.
1-20-06-SS-R
2.0 GREY
25
1.6
30
9
1-20-06-SS-R
2.0 GREY
25
1.6
30
Q
1-20-06-SS-R
2.0 GREY
25
1.6
30
m
1-20-06-SS-R
2.0 GREY
25
1.6
30
®
1-20-06-SS-R
6.0 BLUE
40
5.6
35
pri
1-20-06-SS-R
6.0 BLUE
40
5.6
35
1-20-06-SS-R
6.0 BLUE
40
5.6
35
m
1-20-06-SS-R
6.0 BLUE
40
5.6
35
NOZZLES FOR ROTORS ARE FOR REFERENCE T C CONTRACTOR SHALL ADJUST AS NECESSARY:..
FOR ACTUAL CONDITIONS TO ACHIEVE
MATCHED PRECIPITATION RATES FOR EACH ZONE.
... - N
=��" �►� 2ND AVE SW E "
0 15' 30' 60' 120� e(� z° o
SEE DRAWING L3.2 FOR j
IRRIGATION LEGEND Graphic Scale: 1 30'-0° w w w
o a az