99-102698 1401 59i b)-6 s$ CITY OF FEDERAL WAY pp,,,,,. u � ,, . M _ P p. „w qq, .,,�.. .�, PERMIT NO: ELE99-0746 33530 First Way South E L. E,,tc,,.,,. II 11-1;, ., ,. ti A H f . 1 : �lw�II .»Il.. If ISSUED: 07/13/99 Federal Way., WA 93003 Electrical Inspection Requests 2.53 -661 -4140 BY : FC2 253-661-4000 EXPIRES: 07/06/00 ADDRESS:4614 SW 320TH ST NO. : 112103--9101 PROJECT DESCRIPTION:Alt. comm.- 5 new circuits for tanning booths and 3 new for receptacles r OWNER - _ =z= CONTRACTOR =..------ LENDER ------ - i ! MOSQUITO BAY } -•FULLER ELECTRIC 4614 SW 320TH 137107 12TH AVE S 1 FEDERAL WAY WA 98023 I FEDERAL WAY WA 98003 i i 425-271-6320 661-7181 i FULLEEI027BK . ! *** CONTRACTORS, PLEASE USE LOCATION CODE 1732 WHEN REPORTING SALES TAX FOR PROJECTS WITHIN THE CITY OF FEDERAL WAY. TAX RATE = 8.61 *** * STRUCTURE INFORMATION * I * NEW RESIDENTIAL * t MOBILE HOMES * I * RESIDENTIAL ALTERATIONS * * MULTI FAMILY NEW * SEV FEED CONST. TYPE.: V-N NEW SINGLE FAP'.: SERVICE OR :"SEDER ONLY: 0 0-20C ^M"C...... r ' 0-200 AMPS.... 0 ... 0 OCC. GROUP..: BUILDINGS..: 0 SERVICE' AND FEEDER • 0 I 201.60;; AMPS • 0 201-400 AMPS.: 0 ... 0 1 OUT OCC. LOAD...: 0 ! SERVICE OR FEEDER (PK): 0 1 OVER 600 AMPS..,.,: 0 1 401-600 AMPS.: 0 ... 0 SQUARE FEET.: 0 MAST/METER REPAIR.: 0 601-800 AMPS.: 0 ... 0 NUMBER OF CIRCUITS: 0 801 AND OVER.: 0 ... 0 1 * COMM. ALTERATIONS * * TEMP SERVICE * * MISCELLANEOUS * * COMM/IND NEW * * INSPECTION RECORD * 0-100 AMPS • 0 ... 0 SERVICE DATE 0-200 AMPS • 1 I 0-100 AMPS • 0 THERMOSTATS • 0 101-200 AMPS...: 0 ... 0 201-600 AMPS • 0 101-200 AMPS..: 0 LOW VOLTAGE • 0 201-400 AMPS...: 0 ... 0 COVER.. DATE 601-1000 AMPS...: 0 201-400 AMPS..: 0 SWIMMING POOL..: 0 401-600 AMPS...: 0 ... 0 OVER 1000 AMPS..: 0 I 401-600 AMPS..: 0 SIGNS • 0 601-800 AMPS...: 0 ... 0 FINAL.. DATE NUM. OF CIRCIUTS: 0 I OVER 600 AMPS.: 0 TEMP. POLES • 0 j 801-1000 AMPS..: 0 ... 0 COMMENTS: -- ----- -- --- - -- ---- --- YARD METER LOOP: 0 ODER 1000 AMPS.: 0 0 : 1 TOTAL PERMIT FEES 61.00 OVER 600 VOLTS.: 0 . MAST/METER RPR.: 0 PERMITS EXPIRE 180 DAYS AFTER ISSUANCE IF NO WORK IS STARTED. I CERTIFY THAT THE INFORMATION FURNISHED By M' IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND THE APPLICABLE CITY OF FEDERAL WAY REQUIREMENTS WILL BE MET. OWNER OR AGENT _,,,(V �__ _ ___-_ __--, -- DATE -7-13,7„22_ FILE COPY CITY OF FEDERAL WAY 6 PERMIT NO: ELE99-0746 33530 First Way South ELECTRICAL PERMIT ISSUED: 07/13/99 Federal Way, WA 98003 Electrical Inspection Requests 253-661 -4140 I3Y: FC2 253-661 -4000 EXPIRES: 07/06/00 ADDRESS:4614 SW 320TH ST NO. : 112103-9101 PROJECT DESCRIPTION:AIL cost- 5 neu circuits for tanning booths and 3 new for receptacles .....— MOSQUITO :•Y FULLER ELECTRIC 4614 SW 32010 31107 12IH AVE S FEDERAL WAY WA 98023 FEDERAL WAY WA 98003 425-2716320 661.7181 FULUE10q,f 1 t" CONTWOIS# PLEASE USE LOCATION COIF 1717 WREN RtfORTIN6 SALES TAX FOR PROTECTS V1ININ IRE CITY Of FEDERAL MAY. IAX RATE : 8.6% us * STRUCTURE INFORMATION * * NEW RESIDENT* * ‘ A MILL *NES * ' RESIDENTIAL ALTERATIONS ' * MITI FAMILY NEN t SEV FEED CONST. TYPE.: V-N la mu FAM.: SERVICE Oft FEEDER ONtY: -0 - 1410 AMPS...: 0 ' 0-200 AMPS...: 0 ... 0 OCC. GROUP..: - 404 4 IBUBIGS—. 0 ,ststitt AND f(*KR....; CF: — *400 *IL,,,,4t,"# ' '' ' 201-400 AMPS.: 0 ... 0 OCC, LOAD...: 0 VSEVICI MI , itriNTIANIW6--- - -- OVER 600 ANK....,,It 0 ,,, 401400 AMPS.: 0 ... 0 MARC FEET.: 0 MAST/METER REPAIR.: 0 601-800 AMPS,: 0 ... 0 NUMBER OF CIRCUITS: 0 801 AND OVER.: 0 ,.. 0 1 * COMM. ALTERATIONS * * TEMP SERVICE * * MISCELLANEOUS t t comm/IND NEW $ * INSPECTION RECORD * 0-100 AMPS • 0 0 SERVICE DATE 0-200 AMPS • 1 0-100 AMPS • U THERMOSTATS • 0 101-200 AMPS...: 0 ... 0 1 201-600 AMPS • 0 101-200 AMPS. • 0 LOW VOLTAGE • 0 201-400 AMPS...: 0 ... 0 COVER.. ., DATE 601-1000 AMPS...: 0 201-400 AMPS..: 0 SWIMMING POOL..: 0 401-600 AMPS • 0 ... 0 1 1 OVER 1000 AMPS..: 0 401-600 AMPS..: 0 SIGNS • 0 601.800 AMPS...: 0 ... 0 1 FINAL..11DAT7/50/6;cl 1 RUM. OF CIRCIUTS: 0 OVER 600 AMPS.: 0 TEMP. POLES • 0 801-1000 AMPS..: 0 ... 0 COMMENTST i I - - YARD METER LOOP: 0 OVER 1000 AMPS.: 0 ... 0 1 • TOTAL PERMIT FEES • 67.00 OVER 600 VOLTS.: 0 MAST/METER RPR.: 0 PERMITS EXPIRE 100 DAYS Al 11* ISSUANCE If 10 WORK IS STARTED. I CERTIFY HAI INF INFORMAROM 'WISNER It-IS TRUE AND COPPICE TO ENE PEST Of NY KNONLEICL AND IRE APPLICABLE CllY Of FERN KAY REQUIREMENTS RILL IE NEI. OWNER OR AGENT ,./ n- 4 7 L f',-IL __-/..:-..13.:-.•,...'LK.._ FIELD COPY CITY O . F G L]�� BUILDING DIVISION 1 F_� R 33530 First Way South v\> FTy Federal Way WA 98003 JUL 1 3 1999 (253)661-4000 Fax(253)661-4129 ELECTRICAL PEE ; g-rAPPLICATION ..*Federal Way Business License number: ELO!-A 7 f6 Job Address 4614 SW 320th STREET Job Site Phone Parcel No //Z../D')— ,,/0 ' Lot No Subdivision Name Owner/tenant MOSQUITO BAY Mail Address Phone CORNELIUS LACKS 4614 SW 320th STREET 425-271-6320 Electrical Contractor Address/phone Electrial contractor license number (copy req'ce: FULLER ELECTRIC, INC. 37107 12th Ave. South FULLEEIO27BK Expiration Date: 1 / 12 / 2000 Use of Bldg: o SF Res cl(Comm ❑Other ❑Multi ❑Church/School Class of Work: ❑New l Alteration ❑Addition ❑Repair Describe Work: INSTALL 5 NEW CIRCUITS FOR TANNING BOOTH INSTALL 3 NEW CIRCUITS FOR RECEPTACLES FOR BLOW DRYERS. NEW RESIDENTIAL SERVICES MOBILE HOMES If service is greater than 200 amp, a _Single Family _Service or feeder only $41 (First 1300 ft2-$62;Each add'n 500 ft2-S20) _Service and feeder 67 plan review is req'd. Fee is 35% of Square Feet: pet uut fee +$52. Add'l plan review _Each outbuilding or garage $26 MOBILE HOME/RV PARK for other submissions is $62/hr. (inspected with service) _#of service or feeders _Each outbuilding or garage $41 (First service/feeder-$41;Add'n service/ (Inspected separately) feeder-S26 each) MISC EQUIPMENT/TEMP SERVICES NEW MULTI-FAMILY COMMERCIAL/INDUSTRIAL (Includes three units or more) #of Thermostats(Firstt-stat-$31;add'n-S10 ea) Amps Service or Add'n #of Low voltage fire or burglar alarms Service Feeder Feeder (Residential:first 2500 ft2-S36;Each add'n 500 ft-S10) Up to 200 amp . . . . $67 $20 0 to 100 $67 . . . . $41 (Commercial: 1-4 zone-S36,Each add'n zone-$10) _201 -400 amp . . . . 83 41 _ 101 -200 83 52 401 -600 amp . . . . 114 57 _201 -400 156 62 _#of Signs (First sign-S31;Each add'n sign$15) 601 -800 amp . . . . 146 78 _401 -600 182 73 _Progress inspection per'h hr $31 801 and over 208 156 _ — 601 -800 235 99 —Swimming pool,hot tub,spa 60 801 1000 287 . . . . 120 _Temporary _ Pole 36 _ over 1000 313 . . . . 167 _Yard Pole meter loops 41 _Over 600 volts surcharge 52 Mast or meter repair 57 ALTERED SINGLE/MULTI FAMILY COMMERCIAL/INDUSTRIAL Inspections requested before 3:30pm will be (When inspected separately from the services.) made the following work day,253.661.4140. Altered Service or Feeders Service or Feeder 0 to 200 $67 I hereby certify that I am the owner(or _0 to 200 amp $57 _201 -600 156 authorized agent)of the above named property, _201 -600 amp 83 _601 - 1000 235 or a licensed contractor(or firm's authorized over 600 125 over 1000 261 agent)and am making the installation or Mast or meter repair 31 _#of circuits alteration in compliance with all applicable _#of circuits 40 (First 5 circuits-$52;Add'n circuit-$5 each) city,county,and/or state laws. (1-4 circuits-$41;Add'n circuits$5 each) Temporary Service Applicant's Signature: _0 to 100 $41 �( ti ,1 _ 101 -200 52 (�` _201 -400 62 c� _401 -600 83 Date: C, /–g` over 600 94 EIECrRJCAPP Rt'vism 12/8/98