Loading...
20-104185 Electrical o F � ; Permit #:20-104185-00-ELC , ; Dept FILE 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: TACOMA WATER Project Address: 1502 SW 356TH ST Parcel Number: Project Description: Actual address: 1502 SW 356th St.Federal Way 98023-Tacoma Water 356th St pump station. Tacoma Water electricians will be replacing an old 480V 400A 3-phase disconnect with a newer,more reliable model.In addition,Tacoma Water electricians will be replacing an older portable back-up diesel generator power receptacle with a newer model for better ease of connectivity in the case of an emergency. Also includes trenching and replacing the single underground wiring between the 3-phase 480V utility padmount transformer and the metering pedestal with two parallel runs to increase amperage capacity.An additional conduit will be buried up to the transformer vault to house the secondary run. Owner Applicant Contractor TACOMA PUBLIC UTILITIES RYAN FLOTHTACOMA WATER OWNER 3628 S 35TH ST 3628 S 35TH ST OWNER TACOMA WA 98409 TACOMA WA 98409 Additional Permit Information Is this an Online or O.T.C.application9 Yes .a.:.3. WheS,:0s1r;9,..f,s„att • s Circuits-Commercial 2 Low Voltage-Other(Commel 2 PERMIT EXPIRES Saturday,30 October,2021 Permit Issued on Friday,October 30,2020 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the Ci ederal Way. Owner or agent: ONLIN Date: THIS CARD IS TO REMAIN ON-SITE Federal Wa Construction Inspection Record — y INSPECTION REQUESTS:(253)835-3050 PERMIT#: 20 104185 00 Address: 1502 SW 356TH ST Project: TACOMA PUBLIC UTILITIES FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. I WI ° ID UFER Ground(4295) 0 Ditch cover(4030) 0 Slab/Concrete Floor(4255) Approved Approved I Approved to place concrete By Date j.By �� Date /a"aktO � ..By Date 0 Pool Bonding(4195) Temporary Power(4275) © Service(4235) Approved Approved Approved By Date ,�By Date By Date ® Feeders/Sub-panels(4045) ® Rough Electrical(4225) El Ceiling Cover(4020) Approved Approved Approved By Date . By Date By Date El Final-Electrical(4055) Approved By £ Date HAe"-021 G1 Rough Electrical 0 Final Electrical Cl Right of Way • Approved Approved Approved By Date By Date By Date