Loading...
DaVita Enclosures(GFGTCN9C[9#VJ#XG55WKVG#2146+101(091(5'%6+10#0&6*'0'1(5'%6+10604'9/-+0)%1706;9#5*+0)610 )'0'5+5-%&'8'.12/'06..%&#8+6#$75+0'551((+%'4&Ä  Know what's R %106174+06'48#.ž B SIDE VIEW CANOPY HEIGHT (SEE NOTES) CANOPY WIDTH (SEE NOTES) A B COLUMN BEAM GUTTER DETAIL ASCALE 1 : 4 #12 x 1" SS SCREW-USED FOR INSTALLATIONOF CANOPY DECKING ALUMINUM RIVET-10 PER CORNER SET,6 PER OUTSIDE,4 PER INSIDE EXTRUDEDBEAM BRACKET 1/4-20 x 1-1/2" SS SCREW USED FOR CANOPYFRAMING CONNECTIONS WELDEDEND CAP 1/4-20 x 1-1/2" SS SCREW USED FOR CANOPYFRAMING CONNECTIONS COLUMN WELDEDCOLUMN BRACKET BEAM DETAIL BSCALE 1 : 6 STYROFOAM BLOCKOUT-REMOVED AND FILLED WITHCONCRETE DURING CANOPYINSTALLATION 9 INCH #5 REBAR CONCRETE FOOTING- FOOTING SIZE AS REQUIRED FOR BEARINGUPLIFT AND MOMENT(BY OTHERS) DEFLECTOR PLATE COLUMN 4" 2 34 " 6" DETAIL B SIDE VIEWSCALE 1 : 7 DEFLECTOR PLATE-SEAL TO INTERIOROF COLUMN STYROFOAM BLOCKOUT-REMOVED AND FILLED WITHCONCRETE DURING CANOPYINSTALLATIONCONCRETE FOOTING- FOOTING SIZE AS REQUIRED FOR BEARINGUPLIFT AND MOMENT(BY OTHERS) CONCRETE SLAB(BY OTHERS) 9 INCH #5 REBAR ALUMINUMRIVET COLUMN ISOMETRIC VIEW OF CANOPY SECTION VIEW OF CANOPY ITEM NO.PART NUMBER DESCRIPTION QTY. 1 SHORTWAYS W BEAMS 1 2 4 x 4 x .125 Tube 1'-4 3 6X8 Beam 76'-8 4 4X6 GUTTER 71'-1 5 4 inch Welded Bracket 5' 6 4 End Cap 4'-4 7 6 Inch Extruded Cap 669'-4 1/2 8 3 x 6 x 0.060 Extruded Pan 678'-11 1/4 9 4 Extruded Bracket 5'-2 10 Concrete Slab By Others 1 11 6 inch corner set assembly 4 12 6 Inch Gutter Corner Set 1 13 2"x2"x.125" Angle 8 1/8 14 ALUMINUM RIVET 10 15 6 inch gutter splice 4 16 6 inch gutter splice 1 17 6 Inch Splice 1'-6 18 ALUMINUM RIVET 16 19 #12 x 1" SS SCREW For Installation of Canopy Decking 562 20 1/4-20 x 1-1/2" SS SCREW For Canopy Framing Connections 184 21 4x4 Deflector Plate 16 22 4x4 DEFLECTOR PLATE 1 23 ALUMINUM RIVET 1 24 Small Block Out Assembly 16 25 Small Blockout Removed and filled with concrete during canopy installation (8in.x8in. @ top, 12in.x12in. @ bottom, 12 in. tall)(installed by others) 1 26 Concrete Footing (Small)Footing size as required for bearing, uplift and moment 1 27 7 Inch # 5 Rebar 1 D C B AA B C D 1345678 8 7 6 5 4 3 2 1 E F E F SHEET 1 OF 1 SHORTWAYSWITH BEAMS DATE: TITLE: JOB NAME: STAMP Aluminum Walkway Covers REVISION # : 9/13/2017 2 NOTES:DC = DRAINING COLUMN (IF APPLICABLE)• CANOPY WIDTH RECOMMENDED NOT TO • EXCEED 13'-0" COLUMN HEIGHT RECOMMENDED NOT TO • EXCEED 12'-0" OR WIDTH OF CANOPY, WHICH EVER IS LOWER ALL FASTENERS TO BE 300 SERIES STAINLESS STEEL• OR ALUMINUM SPECIFICATIONS Section 107300 - Aluminum Walkway Covers 1.01 General Description of Work: A. Work in this section shall include design and fabrication of pre-engineered aluminum canopies. B. Canopies are to be fabricated and installed according to approved shop drawings. 1.02 Design Criteria: A. International Building Code 2015 B. ASCE 7-10 C. Aluminum Design Manual 2015 D. Local governing codes and standards for site location 1.03 Materials: A. All materials shall be extruded from aluminum unless indicated otherwise on the drawing. B. Material sizes shall meet or exceed the design criteria on 1.02 1.04 Finishes: A. Factory applied baked enamel to comply with AAMA 2603 B. Color selected from manufacturers standard colors 1.05 Manufacturers: A. Mitchell Metals, LLC -www.mitchellmetals.net - 770-431-7300 B. Dittmer - www.dittdeck.com - 407-699-1755 C. See Specifications 2.1-C for conditions of equivalent systems by other manufacturers.