17-105824v (o M m r` 0 N LO EVERGREEN EYE CENTER - BASEMENT LEVEL LOBBY RENOVATION I GENERAL NOTES: A. UNLESS OTHERWISE NOTED, ALL MATERIAL AND DESIGN SPECIFICATIONS CITED HEREIN SHALL CONFORM TO THE MOST RECENT BUILDING CODE. B. THESE ARCHITECTURAL NOTES ARE A SUPPLEMENT TO THE PROJECT SPECIFICATIONS. ANY DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS, THESE NOTES, AND ANY SITE CONDITIONS SHALL BE REPORTED IN A TIMELY MANNER AND IN WRITING TO THE ARCHITECT WHO SHALL CLARIFY ANY DISCREPANCY IN WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK. C. CONTRACTOR SHALL VERIFY AND COORDINATE THE DIMENSIONS SHOWN ON DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. D. THE ARCHITECTURAL DRAWINGS REPRESENT THE DESIGN INTENT AND ARE NOT INTENDED TO INDICATE THE MEANS AND METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCING, AND SAFETY REQUIRED FOR THIS PROJECT. E. ALL FEATURES OF CONSTRUCTION NOT FULLY SHOWN SHALL BE THE SAME TYPE AND CHARACTER AS SHOWN FOR SIMILAR CONDITIONS SUBJECT TO REVIEW BY THE ARCHITECT. F. ALL PRODUCTS AND MATERIALS BEING PROVIDED BY THE CONTRACTOR SHALL BE APPLIED, PLACED, ERECTED OR INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. G. THESE DOCUMENTS CONTAIN NOTES THAT MAY APPLY GENERALLY TO ALL DESIGN ELEMENTS, SPECIFICALLY TO ONE SHEET, OR SPECIFICALLY TO ONE OR MORE DESIGN ELEMENTS. THE NOTES ARE NOT MERE GUIDELINES, THEY ARE PART AND PARCEL OF THE DESIGN. ANY WORK THAT IS PERFORMED THAT IS NOT IN COMPLIANCE WITH THE NOTES IS NOT IN COMPLIANCE WITH THE DESIGN AND IS SUBJECT TO REJECTION. ANY ALTERATION, MODIFICATION, DELETION, OR ADDITION TO THE NOTES BY WRITING, ACT OR FAILURE TO ACT, SHALL BE CARRIED OUT ONLY WITH THE PRIOR EXPRESS WRITTEN CONSENT AND APPROVAL OF THE ARCHITECT. LOCATION MAP N.T.S TRUE NORTH VICINITY MAP N.T.S TRUE NORTH OWNER: OWNER REPRESENTATIVE: 34719 6TH AVE SOUTH FEDERAL WAY, WA 98003 PROJECT SCOPE: REMODEL OF 600 SF OFFICE LOBBY IN A 4,000 SF MEDICAL OFFICE. WORK TO INCLUDE- DEMOLITION OF PARTITION WALLS AND CEILINGS, CONSTRUCTION OF NEW PARITION WALLS AND CEILINGS, AND NEW FINISHES. THIS SCOPE IS FOR THE LOBY AREA ONLY AND DOES NOT INCLUDE THE REMAINDER OF THE AMBULATORY SURGERY CENTER BEYOND. WORK DOES NOT ALTER EGRESS PATHWAYS, NOR NUMBER AND LOCATION OF EXITS. CODE INFORMATION: PARCEL NO: PROJECT ADDRESS - TAXPAYER - LEGAL DESCRIPTION: PLANNING JURISDICTION: ADOPTED CODE: SITE STATISTICS ZONE - ZONE PRIMARY USES - PRESENT USE SITE PROPOSED USE - SITE SITE AREA - REQUIRED BUILDING SETBACKS- FRONT - SIDE (INTERIOR) - SIDE (STREET) - REAR - BUILDING STATISTICS ALLOWABLE HEIGHT ZONING - ACTUAL HEIGHT - CONSTRUCTION TYPE - OCCUPANCY TYPE - 2021049178 34719 6TH AVE S FEDERAL WAY, WA 98003-7021 GUARDIAN CAPITAL MANAGEMENT 10514 66TH PL W MUKILTEO, WA 98275 E 1/4 OF SW 1/4 OF NE 1/4 OF SW 1/4 LESS N 380 FT LESS CO RD CITY OF FEDERAL WAY CITY OF FEDERAL WAY ZONING CODE OP - OFFICE PARK OFFICE USE, MEDICAL, AND DENTAL OFFICES, RETAIL ESTABLISHMENT PROVIDING BANKING AND RELATED FINANCIAL SERVICES, RETAIL ESTABLISHMENT PROVIDING OFFICE SUPPLIES, PRINTING, AND DUPLICATING IuI_�I.7[�71Si]y7NL� MEDICAL OFFICE (EXISTING) .86 ACRES 25 FT 20 FT 20 FT 20 FT 55'-0" (EXISTING) 34'-8-1/2" (EXISTING) V-A 1 HOUR SPRINKLERED (EXISTING) B - BUSINESS (EXISTING) 1- 1.2 - AMBULATORY SURGICAL CENTER (EXISTING) BUILDING AREAS EXISTING MEDICAL OFFICE BUILDING - 9,181 SF RENOVATED MEDICAL CLINIC BASEMENT LOBBY- 600 SF RENOVATION TOTAL 600 SF NO CHANGE TO BUILDING USE, OCCUPANCY TOTALS, BUILDING FOOTPRINT, TOTAL AREAS, EGRESS PATHWAYS, OR TYPES AND NUMBER OF EXITS. NO EXTERIOR WORK. NO CHANGE TO PARKING. ARCHITECT: ENERGY CODE CALCULATIONS - NO CHANGE TO EXISTING PER 2015 WASHINGTON STATE ENERGY CODE BUILDING ENERGY STANDARDS SHEET INDEX: G0.0 COVER SHEET - LOBBY G0.1 ANNOTATIONS & ACCESSIBILITY A2.1 DEMO PLAN & FLOOR PLAN A2.2 DEMO & REFLECTED CEILING PLAN A2.3 ASSEMBLY & OPENING DETAILS A2.4 CEILING DETAILS 12.0 FINISH PLANS 12.1 ELEVATIONS, INTERIOR DETAILS, SCHEDULES FIRE DEPARTMENT FINAL REQUIRED PRIOR TO BUILDING FINAL. CALL 253-946-7318 FOR INSPECTIONS 2015 IBC 3302.1 Alterations, repairs and additions. Required exits, existing structural elements fire protection devices and sanitary safeguards shall be maintained at all times during alterations, repairs or additions to any building or structure. SLAB ON GRADE - R-10 FOR 24" BELOW EXISTING 1-HR FIRE RATED JOIST/FRAMED FLOORS - R-30 DOOR AND ASSEMBLY SHALL EXTERIOR WALLS - R-21 MEET IBC 716.5.3.1 BASEMENT OPAQUE DOORS - U-0.37 _ , a OCCUPANCY: ROOF -GLASS DOORS - R-OS 0 BASEMENT 85 . i... B , ' 98' 38/ 2 EXITS = 19 NON-METAL WINDOWS - U-0.30 OCCUPANCY: + ' SUBJECT PROJECT 38/ 2 EXITS = 19' ® �► SLAB ON GRADE - NO CHANGE NO CHANGE EXTERIOR WALLS - - NO CHANGE (i r EXISTING DOORS - NO CHANGE 6 - 49 6: D. - - } ! , EXISTING WINDOWS- NO CHANGE ( B �'^ , --I '•-�"66-0„--'--- ---f--------0 C ♦---- c) EXISTING ROOF - NO CHANGE } -ALL FACED BATTS TO BE TAPED TO PROVIDE VAPOR BARRIER. -ALL VAPOR RETARDER TO BE INSTALLED ON WARM SIDE OF INSULATION. - PROVIDE SEALING, CAULKING AND GASKET AS REQUIRED BY NREC, SEE GENERAL NOTES FOR ADDITIONAL INFO. - INSTALL WEATHER STRIPPING AS REQUIRED AT ALL PENETRATIONS. PLUMBING FIXTURES PER TABLE 2902.1 OCCUPANCYTYPE-B OCC. 1 PER 100 SF 9,181 SF/ 100 SF - 104 OCCUPANTS TOTAL PLUMBING OCCUPANT LOAD - 104 (52 MALE, 52 FEMALE NUMBER OF TOILET FIXTURES REQUIRED - 3 EA. MALE/ FEMALE NUMBER OF LAVATORIES REQUIRED - 2 EA. MALE/ FEMALE PARKING CALCULATIONS NO CHANGE TO EXISTING PARKING APPLICABLE CODES 2015 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL FUEL GAS CODE (IFGC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 WASHINGTON STATE ENERGY CODE COMMERCIAL (WSEC) 2015 WASHINGTON STATE ENERGY CODE APPENDIX (WSEC) 2015 UNIFORM PLUMBING CODE (UPC) 2015 NATIONAL FUEL GAS CODE (NFPA 54) 2014 WASHINGTON CITIES ELECTRICAL CODE 2017 NATIONAL ELECTRICAL CODE (NFPA 70) ICC A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES ZONING CODE - CITY OF FEDERAL WAY REVISED CODE GENERAL CONTRACTOR PACIFIC CONSTRUCTION PARTNERS, INC. 12100 NORTHUP WAY BELLEVUE, WA 98005 PHONE: (425) 273 2775 FAX: N/A CONTACT: BRETT REYNOLDSON DEFERRED SUBMITTALS: ELECTRICAL FIRE PROTECTION FIRE ALARM MECHANICAL ENGINEER: ELECTRICAL ENGINEER: EXISTING 1-HR FIRE RATED DOOR AND ASSEMBLY SHALL MEET IBC 716.5.3.1 NOTE: NO CHANGE TO EXISTING EXITS OR EGRESS PATHWAYS EGRESS PLAN - BASEMENT - PROJECT NORTH SCOPE DIAGRAM 1/16" =1'-0" PROJECT NORTH PLUMBING ENGINEER: EVERGREEN EYE CENTER PACIFIC CONSTRUCTION PARTNERS, INC. JACKSON I MAIN ARCHITECTURE P.S. ? ? 34719 6TH AVENUE SOUTH 12100 NORTHUP WAY 311 1ST AVE. S. ? ? FEDERAL WAY, WA 98003 BELLEVUE, WA 98005 SEATTLE WA 98104 ? ? PHONE: (206) 212 2161 PHONE: (425) 998 8208 PHONE: (206) 324 4800 PHONE: ? PHONE: PHONE: ? FAX: (206)212 2194 FAX: (425)458 3276 FAX: (206)322 2875 FAX: ? FAX: FAX: ? CONTACT: ZACHARY SMITH CONTACT: GLENN COMBS CONTACT: BRYANT BRONSON CONTACT: ? CONTACT: CONTACT: ? APPROVED By ELL Date RECEIVED DEC 0 5 2017 JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 9 t 206.324.48 WWW.JACKSONMAIN. M 10818 IMOTMY SEAN BLACK STATE OF WASHINGTON 12/05/2017 4 J Mo >- � W W �Q ZO"� W LL > Q I Q CD W J 0.e I— c w � Q W �w W U cf) 1.1- z O d J Q U w� Wm W IL O w z F o Q u1 ❑ o N PROJECT NO.: PROJECT MGR. DRAWN BY: CHECKED BY: ti ai V (33 m COVER SHE' o m LOBBY m 01 D Z m 0 N Q m n C° GO ■ fnTl Z can JACKSON I MAIN ARCHITECTL 70. v (o M m r` 0 N LO EVERGREEN EYE CENTER - BASEMENT LEVEL LOBBY RENOVATION I GENERAL NOTES: A. UNLESS OTHERWISE NOTED, ALL MATERIAL AND DESIGN SPECIFICATIONS CITED HEREIN SHALL CONFORM TO THE MOST RECENT BUILDING CODE. B. THESE ARCHITECTURAL NOTES ARE A SUPPLEMENT TO THE PROJECT SPECIFICATIONS. ANY DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS, THESE NOTES, AND ANY SITE CONDITIONS SHALL BE REPORTED IN A TIMELY MANNER AND IN WRITING TO THE ARCHITECT WHO SHALL CLARIFY ANY DISCREPANCY IN WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK. C. CONTRACTOR SHALL VERIFY AND COORDINATE THE DIMENSIONS SHOWN ON DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. D. THE ARCHITECTURAL DRAWINGS REPRESENT THE DESIGN INTENT AND ARE NOT INTENDED TO INDICATE THE MEANS AND METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCING, AND SAFETY REQUIRED FOR THIS PROJECT. E. ALL FEATURES OF CONSTRUCTION NOT FULLY SHOWN SHALL BE THE SAME TYPE AND CHARACTER AS SHOWN FOR SIMILAR CONDITIONS SUBJECT TO REVIEW BY THE ARCHITECT. F. ALL PRODUCTS AND MATERIALS BEING PROVIDED BY THE CONTRACTOR SHALL BE APPLIED, PLACED, ERECTED OR INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. G. THESE DOCUMENTS CONTAIN NOTES THAT MAY APPLY GENERALLY TO ALL DESIGN ELEMENTS, SPECIFICALLY TO ONE SHEET, OR SPECIFICALLY TO ONE OR MORE DESIGN ELEMENTS. THE NOTES ARE NOT MERE GUIDELINES, THEY ARE PART AND PARCEL OF THE DESIGN. ANY WORK THAT IS PERFORMED THAT IS NOT IN COMPLIANCE WITH THE NOTES IS NOT IN COMPLIANCE WITH THE DESIGN AND IS SUBJECT TO REJECTION. ANY ALTERATION, MODIFICATION, DELETION, OR ADDITION TO THE NOTES BY WRITING, ACT OR FAILURE TO ACT, SHALL BE CARRIED OUT ONLY WITH THE PRIOR EXPRESS WRITTEN CONSENT AND APPROVAL OF THE ARCHITECT. LOCATION MAP N.T.S TRUE NORTH VICINITY MAP N.T.S TRUE NORTH OWNER: OWNER REPRESENTATIVE: 34719 6TH AVE SOUTH FEDERAL WAY, WA 98003 PROJECT SCOPE: REMODEL OF 600 SF OFFICE LOBBY IN A 4,000 SF MEDICAL OFFICE. WORK TO INCLUDE- DEMOLITION OF PARTITION WALLS AND CEILINGS, CONSTRUCTION OF NEW PARITION WALLS AND CEILINGS, AND NEW FINISHES. THIS SCOPE IS FOR THE LOBY AREA ONLY AND DOES NOT INCLUDE THE REMAINDER OF THE AMBULATORY SURGERY CENTER BEYOND. WORK DOES NOT ALTER EGRESS PATHWAYS, NOR NUMBER AND LOCATION OF EXITS. CODE INFORMATION: PARCEL NO: PROJECT ADDRESS - TAXPAYER - LEGAL DESCRIPTION: PLANNING JURISDICTION: ADOPTED CODE: SITE STATISTICS ZONE - ZONE PRIMARY USES - PRESENT USE SITE PROPOSED USE - SITE SITE AREA - REQUIRED BUILDING SETBACKS- FRONT - SIDE (INTERIOR) - SIDE (STREET) - REAR - BUILDING STATISTICS ALLOWABLE HEIGHT ZONING - ACTUAL HEIGHT - CONSTRUCTION TYPE - OCCUPANCY TYPE - 2021049178 34719 6TH AVE S FEDERAL WAY, WA 98003-7021 GUARDIAN CAPITAL MANAGEMENT 10514 66TH PL W MUKILTEO, WA 98275 E 1/4 OF SW 1/4 OF NE 1/4 OF SW 1/4 LESS N 380 FT LESS CO RD CITY OF FEDERAL WAY CITY OF FEDERAL WAY ZONING CODE OP - OFFICE PARK OFFICE USE, MEDICAL, AND DENTAL OFFICES, RETAIL ESTABLISHMENT PROVIDING BANKING AND RELATED FINANCIAL SERVICES, RETAIL ESTABLISHMENT PROVIDING OFFICE SUPPLIES, PRINTING, AND DUPLICATING IuI_�I.7[�71Si]y7NL� MEDICAL OFFICE (EXISTING) .86 ACRES 25 FT 20 FT 20 FT 20 FT 55'-0" (EXISTING) 34'-8-1/2" (EXISTING) V-A 1 HOUR SPRINKLERED (EXISTING) B - BUSINESS (EXISTING) 1- 1.2 - AMBULATORY SURGICAL CENTER (EXISTING) BUILDING AREAS EXISTING MEDICAL OFFICE BUILDING - 9,181 SF RENOVATED MEDICAL CLINIC BASEMENT LOBBY- 600 SF RENOVATION TOTAL 600 SF NO CHANGE TO BUILDING USE, OCCUPANCY TOTALS, BUILDING FOOTPRINT, TOTAL AREAS, EGRESS PATHWAYS, OR TYPES AND NUMBER OF EXITS. NO EXTERIOR WORK. NO CHANGE TO PARKING. ARCHITECT: ENERGY CODE CALCULATIONS - NO CHANGE TO EXISTING PER 2015 WASHINGTON STATE ENERGY CODE BUILDING ENERGY STANDARDS SHEET INDEX: G0.0 COVER SHEET - LOBBY G0.1 ANNOTATIONS & ACCESSIBILITY A2.1 DEMO PLAN & FLOOR PLAN A2.2 DEMO & REFLECTED CEILING PLAN A2.3 ASSEMBLY & OPENING DETAILS A2.4 CEILING DETAILS 12.0 FINISH PLANS 12.1 ELEVATIONS, INTERIOR DETAILS, SCHEDULES FIRE DEPARTMENT FINAL REQUIRED PRIOR TO BUILDING FINAL. CALL 253-946-7318 FOR INSPECTIONS 2015 IBC 3302.1 Alterations, repairs and additions. Required exits, existing structural elements fire protection devices and sanitary safeguards shall be maintained at all times during alterations, repairs or additions to any building or structure. SLAB ON GRADE - R-10 FOR 24" BELOW EXISTING 1-HR FIRE RATED JOIST/FRAMED FLOORS - R-30 DOOR AND ASSEMBLY SHALL EXTERIOR WALLS - R-21 MEET IBC 716.5.3.1 BASEMENT OPAQUE DOORS - U-0.37 _ , a OCCUPANCY: ROOF -GLASS DOORS - R-OS 0 BASEMENT 85 . i... B , ' 98' 38/ 2 EXITS = 19 NON-METAL WINDOWS - U-0.30 OCCUPANCY: + ' SUBJECT PROJECT 38/ 2 EXITS = 19' ® �► SLAB ON GRADE - NO CHANGE NO CHANGE EXTERIOR WALLS - - NO CHANGE (i r EXISTING DOORS - NO CHANGE 6 - 49 6: D. - - } ! , EXISTING WINDOWS- NO CHANGE ( B �'^ , --I '•-�"66-0„--'--- ---f--------0 C ♦---- c) EXISTING ROOF - NO CHANGE } -ALL FACED BATTS TO BE TAPED TO PROVIDE VAPOR BARRIER. -ALL VAPOR RETARDER TO BE INSTALLED ON WARM SIDE OF INSULATION. - PROVIDE SEALING, CAULKING AND GASKET AS REQUIRED BY NREC, SEE GENERAL NOTES FOR ADDITIONAL INFO. - INSTALL WEATHER STRIPPING AS REQUIRED AT ALL PENETRATIONS. PLUMBING FIXTURES PER TABLE 2902.1 OCCUPANCYTYPE-B OCC. 1 PER 100 SF 9,181 SF/ 100 SF - 104 OCCUPANTS TOTAL PLUMBING OCCUPANT LOAD - 104 (52 MALE, 52 FEMALE NUMBER OF TOILET FIXTURES REQUIRED - 3 EA. MALE/ FEMALE NUMBER OF LAVATORIES REQUIRED - 2 EA. MALE/ FEMALE PARKING CALCULATIONS NO CHANGE TO EXISTING PARKING APPLICABLE CODES 2015 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL FUEL GAS CODE (IFGC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 WASHINGTON STATE ENERGY CODE COMMERCIAL (WSEC) 2015 WASHINGTON STATE ENERGY CODE APPENDIX (WSEC) 2015 UNIFORM PLUMBING CODE (UPC) 2015 NATIONAL FUEL GAS CODE (NFPA 54) 2014 WASHINGTON CITIES ELECTRICAL CODE 2017 NATIONAL ELECTRICAL CODE (NFPA 70) ICC A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES ZONING CODE - CITY OF FEDERAL WAY REVISED CODE GENERAL CONTRACTOR PACIFIC CONSTRUCTION PARTNERS, INC. 12100 NORTHUP WAY BELLEVUE, WA 98005 PHONE: (425) 273 2775 FAX: N/A CONTACT: BRETT REYNOLDSON DEFERRED SUBMITTALS: ELECTRICAL FIRE PROTECTION FIRE ALARM MECHANICAL ENGINEER: ELECTRICAL ENGINEER: EXISTING 1-HR FIRE RATED DOOR AND ASSEMBLY SHALL MEET IBC 716.5.3.1 NOTE: NO CHANGE TO EXISTING EXITS OR EGRESS PATHWAYS EGRESS PLAN - BASEMENT - PROJECT NORTH SCOPE DIAGRAM 1/16" =1'-0" PROJECT NORTH PLUMBING ENGINEER: EVERGREEN EYE CENTER PACIFIC CONSTRUCTION PARTNERS, INC. JACKSON I MAIN ARCHITECTURE P.S. ? ? 34719 6TH AVENUE SOUTH 12100 NORTHUP WAY 311 1ST AVE. S. ? ? FEDERAL WAY, WA 98003 BELLEVUE, WA 98005 SEATTLE WA 98104 ? ? PHONE: (206) 212 2161 PHONE: (425) 998 8208 PHONE: (206) 324 4800 PHONE: ? PHONE: PHONE: ? FAX: (206)212 2194 FAX: (425)458 3276 FAX: (206)322 2875 FAX: ? FAX: FAX: ? CONTACT: ZACHARY SMITH CONTACT: GLENN COMBS CONTACT: BRYANT BRONSON CONTACT: ? CONTACT: CONTACT: ? APPROVED By ELL Date RECEIVED DEC 0 5 2017 JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 9 t 206.324.48 WWW.JACKSONMAIN. M 10818 IMOTMY SEAN BLACK STATE OF WASHINGTON 12/05/2017 4 J Mo >- � W W �Q ZO"� W LL > Q I Q CD W J 0.e I— c w � Q W �w W U cf) 1.1- z O d J Q U w� Wm W IL O w z F o Q u1 ❑ o N PROJECT NO.: PROJECT MGR. DRAWN BY: CHECKED BY: ti ai V (33 m COVER SHE' o m LOBBY m 01 D Z m 0 N Q m n C° GO ■ fnTl Z can JACKSON I MAIN ARCHITECTL 70.