Loading...
21-100713-UP Floor PlanA3.011A3.0125'-0"A2.01FLOOR PLANPROJECT NO.:PROJECT MGR.:DRAWN BY:AJLH18057.00CHECKED BY:LHJACKSON | MAIN ARCHITECTURE P.S. © 2017311 FIRST AVENUE SOUTHSEATTLE, WA 98104t 206.324.4800WWW.JACKSONMAIN.COMJACKSON | MAINA R C H I T E C T U R EELLENOS YOGURT 34114 21ST AVE, S FEDERAL WAY, WASHINGTON DATE NO.DESCRIPTION 1/6/2015 2:45:39 PM 12/06/19 SITE PLAN FOR SEPA REVIEW 02/19/21 MASTER LAND USE APPLICATIONENLARGED PLAN142'-0"±53'-4"13'-6"±14'-10"±7'-3"NEW TANKNEW TANKFUTURETANKFUTURETANK34.0205.0405.0102.0402.0903.0104.0102.0102.12KEYNOTES:11"8'-8" 9'-4" 5'-9"±8'-11"±3'-0"±33.0302.0211'-412"13'-7"55'-0"±33.0102.1302.0505.0302.037'-0"7'-0"33.0208.0208.0123'-0"05.025'-0"4'-7"3'-81 2"33.0334.02CONC.FILLED STEEL BOLLARDS TYP.-REF XX/AX.XX FOR DETAILS05.048"X8" TUBE STEEL CANOPY POST-REF. STRUCTURAL FOR DETAILS05.01PROPOSED STANDING SEAM CANOPY OVER LOADING DOCK02.04EDGE OF DRIVE. REF. SITE PLAN03.01NEW CONC PAD FOR MILK STORAGE TANKS WITH CURB AND DRAIN- REF. STRUCTURAL02.08DEMO EXISTING STAIR, RAILS AND BOLLARD02.09EXISTING MECHANICAL EQUIPMENT TO REMAIN33.03TRENCH DRAIN TO SEWER04.01CMU WALL02.01EXISTING DOOR TO BE REMOVED. INFILL WALL TO MATCH EXISTING02.12RELOCATED OVERHEAD DOOR IN EXISTING OPENING. INFILL REMAINING OPENING TOMATCH ADJACENT WALLS.02.02EXSITING CONC. STAIR WITH APPROXIMATELY 11" TREADS 7" RISERS02.03EXISTING FENCE TO REMAIN33.01DRAIN TO SEWER05.02GUARDRAIL05.03HANDRAIL08.01APPROXIMATE LOCATION OF TANKER ACCESS02.05TOP OF SLOPE02.06EXISTING PIPE02.07EXISTING COILING DOOR08.02CLEARANCE AROUND TANKER ACCESS33.02DRAIN WITH FILTRATION TO SEWER02.13EXISTING HANDRAIL02.0802.0602.0719'-3"