20-101828-Planset-05-06-2020-V180.00 N 89° 55' 11" E 80.00 N 89° 55' 11"E80.0 N 89° 55' 11"E130.31 N 89° 55' 11"EAND REQUIRED SETBACK20' - 0" EXISTINGSETBACK 5' - 0" REQ'D SETBACK 5' - 0" REQ'D 5' - 0"S 303rd STREET (E) ASPHALT DRIVEWAY (E) PATIO ALL TREES TO REMAIN, TYP 1,702 SF FOOTPRINT EXISTING SINGLE FAMILY RESIDENCE 12' - 8 1/2"6' - 0"12' - 0"153 SF ADDITION EXISTING SETBACK 13' - 2 3/4" +/- EXISTING SETBACK 12' - 8 1/2" +/-SETBACK54' - 6" PROPOSEDAT LEAST 2 EXISTING LEGAL PARKING SPOTS PROVIDED ON SITE NEW CRAWLSPACE ACCESS WELL. PROVIDE RIVER ROCK AT BOTTOM. CONTRACTOR TO CONFIRM FREE- DRAINING DRIVEWAY WIDTH 20' - 0" +/- EXISTING SA FF FF FF FF ND ND 16' - 0"11' - 6" HATCH INDICATES 680 SF OF SOIL AMENDED AREA (SEE DETAIL). ENTIRE REST OF SITE IS NON-DISTURBED FILTER FENCE PER DETAIL Land Use/ Zoning Address: Tax ID #: Legal Description: Zone: Building Square Footage: (E) Garage: (E) House: Proposed Addition: 1431 S 303rd St, Federal Way, Washington 98003 025300-0225 AQUACENE ADD, PLat Block: 3, Plat Lot: 6 RS 9.6 348 SF 1,354 SF 153 SF Lot Size: Lot Coverage: Footprint Area: Permitted Area: 10,400 SF 1702 SF Existing House +153 SF New Addition 1855 SF Total = 17.8%, therefore okay 60% per 19.200.010, note 6 Front Yard: Min. Req'd: Proposed: West Side Yard: Min. Req'd: Proposed: East Side Yard: Min. Req'd: Proposed: Rear Yard: Min. Req'd: Proposed: 20'-0" no change 5'-0" no change (much greater than 5'-0") 5'-0" no change (much greater than 5'-0") 5'-0" 54'-6" (per fence measurement; survey not req'd) Height Limit: Parking: Required: Proposed: N/A, 30ft height limit, addition lower than existing single story house (existing max height appx. 11'-8") 2 spaces per 19.200.010 no change (2 shown on plan) Project Information Project Address: Owner Assessor Parcel No: Legal Description: Project Description: 1431 S 303rd St, Federal Way, Washington 98003 James & Vicki Carey 0253000225 AQUACENE ADD PLat Block: 3 Plat Lot: 6 Small 150 SF, one story addition to existing house. Replace windows in existing bedrooms to provide code compliant egress. Codes Used -City of Federal Way All construction to be done in accordance with the code versions listed below, and all local codes as applicable. 2015 International Residential Code (Architectural) 2015 International Building Code (Structural) 2015 Washington State Energy Code Contact Information Owner:James & Vicki Carey 1431 S 303rd St, Federal Way, Washington 98003 t: 1-253-839-3554 e: jvcarey2@msn.com Applicant/Architect: Structural Engineer: Motionspace Architecture + Design PLLC Contact: Nazim Nice 3104 Western Avenue #107 Seattle Washington 98121 t: 206.204.0490 email: nazim@motion-space.com www.motion-space.com Keith Ryan, P.E. TSE Engineering 12810 N.E. 178th St Suite 218 Woodinville, WA, 98072 Office: 425-481-6601 keith@tse-aep.com Vicinity Map General Notes GENERAL 1. All smoke detectors in areas of new construction shall be interconnected to a device audible in sleeping areas and receive their primary power from the building wiring. Battery backup is required. Smoke detectors to be located per approved plans and following manufacturer's instructions. 2. Buildings should have approved address numbers, building numbers, or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. The numbers shall contrast from their background. Numbers shall be a minimum of 4" high and have a minimum stroke width of 1/2". 3. Usable space under stairs shall be lined with 1/2" type-x GWB and fire taped. Provide fire blocking between studs in line with stair stringers and between stair stringers. 4. Guardrails must be 36" high min. and constructed to resist a 200 PLF force at right angle to the top rail and a 50 PSF load for infill components. The max opening shall be such that a 4" dia. sphere cannot pass through. Guardrails to be located at surfaces 30" or more above grade. 5. All appliances to be installed per manufacturer's instructions. 6. Provide minimum 26GA flashing and counter flashing where roof meets vertical surface. 7. Dampproof walls below grade per approved method. 8. Lead paint removal shall be done according to the current RRP (Renovation, Repair, and Painting) rules as defined by the EPA and the State of Washington. CONTRACTOR NOTES 1. Do not scale off the drawings for construction purposes. If a dimension is not provided in the drawings, the contractor shall notify the architect before proceeding with work. 2. Drawings are for reference only. The contractor is responsible for and in charge of means, methods, sequences of construction, safety issues, and fulfilling the requirements of the applicable building codes. 3. In the event of discrepancies in this plan set among architectural plans, structural plans, existing conditions, building codes, or any other information provided, the contractor shall notify the architect before proceeding with work. Any work performed prior to consulting the architect that is found to not conform to the contract documents shall be corrected at the contractor's expense. Contractor and/or owner-initiated changes shall be submitted in writing to the architect for approval prior to fabrication or construction. Changes shown on shop drawings only will not satisfy this requirement. 4. Submittal of door, window and hardware schedules is required. Do not order until architect and owner have approved. If architect is not hired to fully review submittals the owner must perform a thorough review and is responsible for correcting any errors. 5. Deferred Structural Submittals: items including, but not limited to, prefabricated wood trusses, open web wood floor trusses, and steel posts & beams designed by others shall include stamped calculations, shop drawings and product data. Design shall be prepared by the SSE (Specialty Structural Engineer), who is retained by the General Contractor, Subcontractor or Supplier. Submittals shall be provided to the Architect and Structural Engineer of Record for review prior to ordering and installation. Review of the SSE's shop drawings is for general compliance with design criteria and compatibility with the design of the primary structure and does not relieve the SSE of responsibility for that design. All necessary bracing, ties, anchorage, and proprietary products shall be furnished and installed per manufacturer's instructions or the SSE's design drawings and calculations. 6. Drawings may not show the full extent of GWB/plaster removal necessary to complete the project. Contractor to determine the extent of GWB/plaster removal necessary. 7. If contractor or owner observes poor draining soil, and/or excessive water on the site during construction (particularly water percolating up from soils), consult with architect as necessary to determine if additional drainage is required to waterproof the structure. MECHANICAL, PLUMBING & ENERGY 1. All exterior joints shall be sealed, caulked, gasketed, or weather stripped to limit air leakage at the following locations: window and door frames, openings between walls and foundations, between wall and roof, openings at penetrations of utility services, and all other openings in the building envelope. 2. Insulate and weatherstrip all attic hatches and doors. 3. Exhaust hood systems capable of exhausting in excess of 400 cubic feet per minute shall be provided with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. 4. Programmable thermostats shall be installed at all forced air heating and cooling equipment devices. 5. All plumbing fixtures to meet the following standards: Toilets: 1.6GPF, Faucets: 2.5GPM, Showerheads: 2.5GPM 6. Exterior hose bibs shall be of no freeze type with vacuum breaker. 7. Secure water heater to adjacent walls with metal strapping to meet all codes. FRAMING 1. Foundation plates shall be pressure treated and 6" min. above finish grade. 2. Provide 18" min clearance from grade to bottom of floor joists and a min. of 12" to bottom of girders. 3. Structural panel components of the structure such as softwood, plywood, particle board, wafer board, and oriented strand board shall be identified as "exposure 1," "exterior," or "hud approved." 4. When there is usable space both above and below the concealed space of a floor/ceiling assembly, draft stops shall be installed so that the area of the concealed space does not exceed 1,000SF. Fire blocking shall be provided to cut off all concealed draft openings and to form an effective fire barrier between stories, and between a top story and the roof space. 5. All combustible materials surrounding a masonry fireplace shall be separated from the masonry per current code. Combustible material around a prefabricated fireplace shall meet code requirements and manufacturer's requirements. 6. Required attic access openings shall be rough framed to a minimum of 30" x 22" and have a minimum unobstructed headroom of 30" 7. All wood in contact with concrete or masonry shall be pressure-treated with an approved preservative or (2) layers of asphalt impregnated building paper shall be provided between untreated wood and concrete or masonry. 8721 REGISTERED ARCHITECT NAZIM NICE STATE OF WASHINGTON 3104 Western Avenue Suite 107 Seattle WA 98121 206.204.0490 www.motion-space.commotionspacearchitecture + design PLLCJOB # DATE 5/5/2020 2:19:20 PMA1.0 Carey Addition1431 S 303rd St, Federal Way, Washington 98003Permit SetSite Plan, Land Use, Erosion Control, and General Notes 1 May 2020 MS2020-01 1/8" = 1'-0" Site Plan Carey Residence Addition 1431 S 303rd St, Federal Way, Washington 98003 A1.0 Site Plan, Land Use, Erosion Control, and General Notes A2.0 Floor, Foundation, and Framing Plans A3.0 Exterior Elevations and Building Sections A9.0 Window and Door Schedules, Energy Requirements A10.0 Perspective Views S1.0 Structural Notes & Details S2.0 Structural Details Drawing List No. Date Revision Description 20-101828-Planset-05-06-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 07 2020 C S2 ENGINEERS SEAL IS FOR LATERAL AND GRAVITY LOAD DESIGN OF NEW ADDITION ONLY. ALL OTHER BUILDING DESIGN IS BY OTHERS 05/04/20 20-101828-Planset-05-06-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 07 2020 Main Level 0" Main Level Top Plate 7' -8" W07 EG R W06 EG R Main Level 0" Main Level Top Plate 7' -8" EQ EQ EQ W03 EG W04 EG R W05 EG R W02 MAXIMUM BUILDING HEIGHT11' - 8" APPXNEW 24x18 CRAWLSPACE ACCESS + VENT HATCH EXTEND NEW SIDING TO EDGE OF NEW WINDOW W03 LINE BETWEEN EXISTING HOUSE AND ADDITION EXISTING DOWNSPOUTS TO REMAIN 2x8 FASCIA AT EAVE Main Level 0" Main Level Top Plate 7' -8" EQ 8' - 0"EQ ALLOW FOR ONE NEW HOSE BIBB. CONFIRM LOCATION W/ OWNER. ALLOW FOR NEW EXTERIOR POWER OUTLET. CONFIRM LOCATION WITH OWNER CEMENT BOARD PANEL SIDING WITH TAMLYN REVEAL TRIM, TYP AT ADDITION TAMLYN XTREME TRIM PROFILES: At Exterior Corners: XOCR516 At typ panel joint: RH516 (horizontal), RV516 (vertical). At transition between old and new siding: FR516 2x8 FASCIA AT RAKE Main Level 0" Main Level Top Plate 7' -8" W08 EG R Main Level 0" Main Level Top Plate 7' -8" W01 Main Level 0" Main Level Top Plate 7' -8" A3.0 7 Master Closet Master Bath 3 " / 1 2 "3" / 12"EXISTINGMATCHHEADER PER STRUCT INSTALL WINDOWS PER DETAIL , TYP CEMENT BOARD SIDING o/ BLDG PAPER o/ SHEATHING PER STRUCTURAL o/ 2x6 STUDS @ 16" O.C. w/ R-21 FIBERGLASS BATT INSULATION GYP BD WRAP AT WINDOW INTERIOR, TYP FLASHING (LAP BUILDING PAPER OVER FLASHING) R-10 RIGID INSULATION @ HEADER, TYP GWB OVER VAPOR RETARDER. IF USING CLOSED CELL SPRAY FOAM, OMIT VAPOR RETARDER, TYP WHERE INSTALLED > 2" THICKNESS HARDWOOD SILL MEMBRANE ROOFING O/ PLYWOOD PER STRUCTURAL LAP ROOFING OVER FLASHING, TYP EXPOSED 2x4 RAFTER TAILS AT EAVES, TYP RAKE PER ELEVATIONS VENTED FRIEZE BLOCK BETWEEN JOISTS. STAPLE INSECT SCREEN TO BACK OF BLOCK BATT INSULATION AT ROOF TO R-49 THICKNESS WHERE POSSIBLE CONTINUE ROOFING OVER END OF BARGE RAFTER 2x FASCIA PER ELEVATIONS ROOF SLOPE PER ROOF PLAN PER ROOF PLAN O.H. FACE OF FRAMING TO FASCIA 1" MI N. REQUIRED CLEAR VENTILATION SPACE AT EACH JOIST BAY PRESSURE TREATED SILL PLATE. MATCH SILL PLATE DEPTH / FOUNDATION WALL HEIGHT AT EXISTING FOUNDATION WALL. FASTEN TO CONCRETE BELOW PER STRUCTURAL SLOPE GRADE AWAY FROM HOUSE, TYP FILTER FABRIC & DRAINAGE MAT O/ FOUNDATION WATERPROOFING. INSTALL TERMINATION STRIP PER MANUFACTURER'S INSTRUCTIONS SILL SEAL FLOOR JOIST PER STRUCTURAL ALIGN FACE OF FRAMING WITH FACE OF CONCRETE, TYP FLASHING (LAP BUILDING PAPER OVER FLASHING, TYP) PLYWOOD SUB-FLOOR PER STRUCTURAL FINISH FLOOR R-38 INSULATION MINIMUM AT FLOORS CRAWLSPACE VENTILATION / ACCESS AS REQUIRED STEEL REINFORCEMENT PER STRUCT. 4" PERFORATED FOUNDATION DRAIN PIPE INSTALLED WITH HOLES ORIENTATED DOWN SLOPE TO DRAIN AT APPROPRIATE OUTFALL (TIE IN W/ EXISTING FOUNDATION DRAIN) WASHED ROCK -7/8" MINIMUM SIZE FOOTING PER STRUCT. FILTER FABRIC VAPOR BARRIER /1 A9.0 8721 REGISTERED ARCHITECT NAZIM NICE STATE OF WASHINGTON 3104 Western Avenue Suite 107 Seattle WA 98121 206.204.0490 www.motion-space.commotionspacearchitecture + design PLLCJOB # DATE 5/4/2020 12:19:09 PMA3.0 Carey Addition1431 S 303rd St, Federal Way, Washington 98003Permit SetExterior Elevations and Building Sections 1 May 2020 MS2020-01 1/4" = 1'-0" North1 1/4" = 1'-0" West2 1/4" = 1'-0" South3 1/4" = 1'-0" Bedroom Wing -East4 1/4" = 1'-0" Addition -East5 1/4" = 1'-0" E-W Through Addition6 1 1/2" = 1'-0" Typical Wall Section7 No. Date Revision Description 20-101828-Planset-05-06-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 07 2020 DOOR NOTES Door schedule indicates door panel size except in the case of unit doors, where it indicates rough opening size. Unit doors are noted in schedule. Verify with Architect all door sizes before framing openings. All operations noted on floor plans and/or elevations. If a door key is provided, it is for convenience and may not indicate all the necessary options of a door. In remodels, exterior door sizes indicated may be approximate. Contractor to confirm actual door sizes and rough opening sizes for all doors. Provide door submittals to Architect prior to ordering doors. All window headers & casings should align with door header casings & trims on exterior and interior of building unless noted otherwise. All glazing in new doors to be approved safety-glazing. Contractor is to verify that all doors requiring safety glazing are manufactured and installed with the correct glazing. See project specifications for door manufacturer and other information. All exterior doors and doors to unheated spaces shall be fully weatherstripped. WINDOW NOTES Window head heights measured from subfloor or top of concrete slab -confirm with Architect. If gypcrete is present, confirm head height base point with Architect. Window schedule indicates rough opening sizes. Verify with Architect all window sizes before framing openings. Provide window submittals to Architect prior to ordering windows. All window headers & casings should align with door header casings & trims on exterior and interior of building unless indicated otherwise. Adjust R.O. heights or cut down doors as necessary (consult w/ architect as necessary). See project specifications for window manufacturer and other information. Contractor to order egress windows with proper egress hardware where required to meet code requirements. Contractor to verify all egress windows ordered meet current code egress requirements. Casement egress windows must open 90 degrees minimum. ROUGH FRAMED WINDOW OPENING STEP 1) APPLY APPROVED APRON, ALIGN WITH BOTTOM OF OPENING AND ATTACH ONLY AT TOP STEP 2) APPLY ADHESIVE-TYPE FLEXIBLE FLASHING (INSTALL SQUARE IN OPENING AND TIGHT IN CORNERS, THEN FOLD AROUND) COMPLETELY ENCASE SILL, 3" MIN WRAP AT SIDES STEP 6) INSTALL WINDOW PER MANUFACTURES RECOMMENDATIONS STEP 8) APPLY ADHESIVE-TYPE HEAD FLASHING OVER TOP FLANGE AND SIDE FLASHING STEP 9) APPLY 1ST COURSE OF BUILDING PAPER, TUCK UP AND UNDER APRON 12" 12" 12 " 6" STEP 7) CLEAN FACE OF WINDOW FLANGES AND APPLY ADHESIVE-TYPE STRAIGHT FLASHING ON SIDES, COMPLETELY LAP SIDES OF SILL PAN, EXTEND 4" ABOVE AND BELOW OPENING STEP 10) APPLY COURSES OF BUILDING PAPER IN WEATHERBOARD FASHION, LAPPING JOINTS A MIN OF 3" (4"-6" RECOMMENDED) BUILDING PAPER WIDTH MAY VARY. IT IS CRITICAL THAT BUILDING PAPER LAPS FLASHING AT WINDOW HEAD AND BUILDING PAPER GOES UNDER APRON FLASHING. APRON FASTENERS 4" MIN 4" MIN WINDOW FLANGE NOTE: VERIFY THAT ALL FLASHING, SILL PAN FLASHING, BUILDING PAPER, AND SEALANT IS APPROVED COMPATIBLE. STEP 3) ADD ADHESIVE-TYPE FLASHING AT SIDES OF OPENING, LAP OVER PAN FLASHING STEP 4) ADD FLEXIBLE ADHESIVE-TYPE FLASHING AT WINDOW HEAD, APPLY OVER SIDE FLASHING STEP 5) APPLY CONTINUOUS 3/8" BEAD OF SEALANT TO TOP AND SIDES AT EDGE OF OPENING IMMEDIATELY PRIOR TO WINDOW INSTALLATION (ONLY IF FLANGE-TYPE WINDOW IS TO BE INSTALLED) CORRECT INCORRECT SILL ROUGH FRAMED WINDOW OPENING STEP 1) APPLY APPROVED APRON, ALIGN WITH BOTTOM OF OPENING AND ATTACH ONLY AT TOP STEP 2) INSTALL HARD SILL PAN OVER APRON 12" 12" 12" APRON FASTENERS LAP 6" MIN AT ENDS LOWEST COURSE OF BUILDING PAPER STEP 3) ADD ADHESIVE-TYPE FLASHING AT SIDES OF OPENING, LAP OVER PAN FLASHING STEP 4) ADD FLEXIBLE ADHESIVE-TYPE FLASHING AT WINDOW HEAD, APPLY OVER SIDE FLASHING STEP 5) APPLY CONTINUOUS 3/8" BEAD OF SEALANT TO TOP AND SIDES AT EDGE OF OPENING (ONLY IF FLANGE-TYPE WINDOW IS TO BE INSTALLED) BASIC CONCEPT: ENVELOPE IS WATER TIGHT PRIOR TO SIDING (YOU COULD TAKE A WATER HOSE TO THE HOUSE PRIOR TO SIDING AND NO WATER WOULD REACH THE WOOD FRAMING. ALTERNATE HARD SILL PAN APRON METHOD -SUBSTITUTE STEPS 1 -5 WITH THESE (TYPICAL DOOR FLASHING SIMILAR) 4"1" ENERGY CODE REQUIREMENTS Washington State Energy Codes (2015 Edition) : Table 402.1.1 Prescriptive Energy Code Compliance for Climate Zone 5 & Marine 4 Fenestration U-Factor Ceiling R-Value Wood-Frame Wall R-Value Wall Below Grade * 0.30 NFRC R-49 R-21 -- Floor R-Value R-30 Slab on Grade R-Value and Depth -- Vaulted Ceiling R-Value -- Skylight U-Factor -- Glazed Fenestration SHGC --0.28 NFRC per credit 1A * "10/15/21 + TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21 +TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "TB" means thermal break between floor slab and basement wall. Window and door headers shall be insulated with a minimum of R-10 insulation where structural allows (or to the maximum extent the structure allows). Advanced framing allows full depth across entire surface. Install R-49 if insulation is reduced around ceiling perimeter ENERGY CREDITS: Additions less than 500 SF require 0.5 Credits per WSEC R406.2 4 Credit selected: Efficient Building Envelope 1A (0.5 Credits) LIGHTING:Minimum 75% of permanently installed lamps in lighting fixtures shall be high efficacy lamps. DUCTWORK:N/A AIR LEAKAGE:N/A ENERGY:N/A R-38 per credit 1A EGRESS OPENINGS & FALL PROTECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS R310.2.2 Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches measured from the finished floor to the bottom of the clear opening. R310.2.1.All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet. Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet. R310.2.1 The minimum net clear opening height shall be 24 inches. R310.2.1 The minimum net clear opening width shall be 20 inches. R310.1.1 Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys, tools or special knowledge. R312 GUARDS & WINDOW FALL PROTECTION R312.2.1 -In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located. Glazing between the floor and 24 inches shall be fixed or have openings through which a 4-inch-diameter sphere cannot pass. Exceptions: 1. Windows whose openings will not allow a 4-inch- diameter sphere to pass through the opening when the opening is in its largest opened position. 2. Openings that are provided with window guards that comply with ASTM F 2006 or F 2090. WSEC R303.1.3 FENESTRATION PRODUCT RATING Glazing to be NFRC labeled per WSEC R303.1.3. 8721 REGISTERED ARCHITECT NAZIM NICE STATE OF WASHINGTON 3104 Western Avenue Suite 107 Seattle WA 98121 206.204.0490 www.motion-space.commotionspacearchitecture + design PLLCJOB # DATE 5/4/2020 12:19:10 PMA9.0 Carey Addition1431 S 303rd St, Federal Way, Washington 98003Permit SetWindow and Door Schedules, Energy Requirements 1 May 2020 MS2020-01 Window Flashing Detail (Typical Door Flashing Similar -Install w/ Hard Sill Pan Method)1 New - Window Schedule Mark Replacement * Width (RO) Height (RO) Head Height Operation Thermal Safety Privacy Egress Location Description Glazing Area W01 72" 24" 6' - 10 1/2" 2x Fixed ●Master Bath 12 SF W02 36" 24" 6' - 10 1/2" Awning ●Master Closet 6 SF W03 36" 48" 6' - 10 1/2" Casement ●● (E) Master Bedroom 12 SF W04 ● 72" 48" 6' - 10 1/2" Slider ●● (E) Southwest Bedroom 24 SF W05 ● 72" 48" 6' - 10 1/2" Slider ●● (E) NW Bedroom 24 SF W06 ● 72" 48" 6' - 10 1/2" Slider ●● (E) NW Bedroom 24 SF W07 ● 72" 48" 6' - 10 1/2" Slider ●● (E) NE Bedroom 24 SF W08 ● 72" 48" 6' - 10 1/2" Slider ●● (E) NE Bedroom 24 SF 147 SF New - Door Schedule Mark Panel or Unit Width * Height * Thickness Operation Safety Glazing Thermal Privacy Location Description Glazing Area D01 Panel 2' - 8" 6' - 8" 1 3/8" Swing Master Bath 0 SF D02 Panel 2' - 8" 6' - 8" 1 3/8" Swing Master Closet 0 SF 0 SF * Field verify all replacement window sizes. On this project, replacement windows match existing width only; sill will typically be lowered from existing. * Width & Height are indicated as RO for unit doors, and as panel size for panel doors; "Opening" sizes are clear opening dimensions 12" = 1'-0" Dispersion Trench from KCSWDM Appendix C2 No. Date Revision Description 20-101828-Planset-05-06-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 07 2020 8721 REGISTERED ARCHITECT NAZIM NICE STATE OF WASHINGTON 3104 Western Avenue Suite 107 Seattle WA 98121 206.204.0490 www.motion-space.commotionspacearchitecture + design PLLCJOB # DATE 5/4/2020 12:19:18 PMA10.0Carey Addition1431 S 303rd St, Federal Way, Washington 98003Permit SetPerspective Views 1 May 2020 MS2020-01 No. Date Revision Description 20-101828-Planset-05-06-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 07 2020 05/01/20 20-101828-Planset-05-06-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 07 2020 05/01/20 20-101828-Planset-05-06-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 07 2020