20-101886-Site Plan-05-11-2020-V1FOUNDATION PLANS-2SHEETPROJECT NAME DRAWN BY CHECKED BY - SHEET DATE DESCRIPTIONSCALE REVISIONS DESCRIPTION DATE BY MRT - 2 PROJECT NUMBER 2 of 20NOTES: a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR THE PILE ASSEMBLY SHALL BE SPECIFIED BY THE PILE MANUFACTURER. THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING INCLUDING A SAFETY FACTOR NO LESS THAN 2. THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY. MAXIMUM INSTALLATION TORQUE RATING OF 8300FT*LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL THICKNESS PER ESR-3750. b. TYP EXTERIOR TO DENOTE PILE INSTALLATION AT EXISTING EXTERIOR CONCRETE FOUNDATION WITH MINIMUM DIMENSIONS PER PLAN NOTES c. HELICAL PILES AS MANUFACTURED BY IDEAL MANUFACTURING, INC., IN ACCORDANCE WITH ESR-3750 WITH 2-7/8 INCH MINIMUM SHAFT DIAMETER AND 0.203 INCH MINIMUM WALL THICKNESS. d. PILE LOADS NOT TO EXCEED MAXIMUM PILE LOAD CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF PILE ASSEMBLY. MAXIMUM ALLOWABLE COMPRESSION CAPACITY OF 37.4 KIPS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL THICKNESS PER ESR-3750. e. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. SITE & FOUNDATION PLANNOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. FOUNDATION NOTES SITE PLAN LEGEND EXISTING RESIDENCE STRUCTURE EXISTING ADJACENT STRUCTURE AREA OF PROPOSED WORK PROPERTY LINE * APPROXIMATE DIMENSION S200303-1 ZT 5/3/2020 1. VERIFY ALL DIMENSIONS ON SITE. 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. 3. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED MAY 3RD, 2020, FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND REQUIREMENTS. 4. LEVEL SURVEY PER R&R REPAIR PLAN DATED MARCH 2ND, 2020. REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. 5. MINIMUM PILE DIAMETER SHALL BE 2-7/8”. 6. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH ± 0'-6" TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION OF 8'-0"O.C. MAXIMUM. 7. ALL SUPPLEMENTAL CHANNELS TO SPAN FROM PILE TO PILE AND EXTEND MIN 6" PAST SUPPORTING PILE EA END. 8. ALL SUPPLEMENTAL CHANNELS TO BE ANCHORED TO THE FOUNDATION WITH 5/8" DIAM. SIMPSON TITEN HD SCREW ANCHORS (OR APPROVED EQUIVALENT) AT A MAXIMUM SPACING 12"OC WITH A MIN 4-1/2" EMBEDMENT. ANCHORS TO BE CENTERED ON OR INSTALLED ABOVE THE CENTER LINE OF THE CHANNEL. 9. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8" THICK MINIMUM WITH 2'-8" HEIGHT (MEASURED FROM B/FTG TO T/CONC) MINIMUM. 10. PARCEL DIMENSIONS PROVIDED BY KING COUNTY. NOT TO SCALE. PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS (WITH ASTERISK, *) APPROXIMATED PER KING COUNTY GIS MAPPING TOOLS. NOT TO BE USED FOR LEGAL PURPOSES. 11. SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. 12. PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0". HELICAL PILE REFUSAL CRITERIA: TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO. ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. PROOF TESTING: THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2015 SEATTLE BUILDING CODE (SBC). THE MAXIMUM TEST LOAD SHALL BE TWO-HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. 4021 SW 321ST ST FEDERAL WAY, WA 98023 R&R LEVEL SURVEY See Structural Calculation Package for Additional Requirements RESIDENCE 4021 SW 321ST ST FEDERAL WAY, WA 98023 DRIVEWAYACCESSPRIMARYACCESS76'-0" * PROPE R T Y L I N EPROPERTY LINE107'-0" *119'-0" *PROPERTY LINE78'-0" * PROPERTY LINE (E) DECK 63'-0"34'-0"23'-0" 3'-0" 5'-0" 14'-6"20'-0"22'-0"12'-0"SW 321ST ST 4027 SW 321ST ST FEDERAL WAY, WA 98023 4017 SW 321ST ST FEDERAL WAY, WA 98023 PARCEL NO. 873190-2310 LEGAL DESCRIPTION TWIN LAKES # 2 230 LESS POR LY NELY OF LN BEG 4 FT N OF MOST ELY COR TH SWLY TO MOST SLY COR & THE TERMINUS OF SD LN & ALL 231 PLat Block: Plat Lot: 230-231 OWNER NAME & ADDRESS BABCOCK MARALYN C 4021 SW 321ST ST 98023 AREA OF WORK RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT May 14 2020 20-101886-Site Plan-05-11-2020-V1