20-101626-Planset-04-22-2020-V11 A1.1 ROOM NAME 101 ROOM NAME ROOM NUMBER DIMENSION POINT OR ELEVATION PARTITION TYPE -SEE A7.1 DOOR NUMBER SEE A7.1 EXTERIOR ELEVATION DRAWING # SHEET # INTERIOR ELEVATION BUILDING SECTION DETAILS DETAIL # SHEET # DETAILS THAT ARE SIMILAR TO THE DETAIL SHOWN DETAIL # SHEET # DETAILS THAT ARE TYPICAL AND WILL OCCUR IN MULTIPLE LOCATIONS DETAIL # SHEET # DRAWING # SHEET # DRAWING # SHEET # SIM. TYP. 101 1i A101 1 Ref A101 1 Ref A1.1 1 A1.1 1 A1.1 1 1 A1.1 BUILDING SECTION DRAWING # SHEET # ISSUE DATE: CONTENTS: SCALE: DRAWN: CHECKED: PROJECT NO: SHEET: 2018020.000650 SW CAMPUS DRIVEFEDERAL WAY, WA 980231/4" = 1'-0"KING COUNTY AQUATIC CENTER -SKYLIGHT REPLACEMENTPERMIT SET PROJECT INFO PRC/EGW/CNV SWL T1.0 APRIL 20, 2020 DESIGN TEAM OWNER: KING COUNTY PARKS CONTACT: MATTHEW PERKINS, CAPITAL PROJECT MANAGER 201 S JACKSON STREET, KSC-NR-0700 SEATTLE, WA, 98104 PH: 206-263-3331 EMAIL: MATTHEW.PERKINS@KINGCOUNTY.GOV ARCHITECT: ARC ARCHITECTS CONTACT: JEFF WANDASIEWICZ, PRINCIPAL CONTACT: JON KAMITA, PROJECT MANAGER 119 SOUTH MAIN STREET, SUITE 200 SEATLE, WA 98104-2579 EMAIL: WANDASIEWICZ@ARCARCHITECTS.COM EMAIL: KAMITA@ARCARCHITECTS.COM PH: 206-322-3322 CONTRACTOR: DEAMOR CONSTRUCTION CONTACT: ANTHONY JENSEN 12822 GATEWAY DRIVE, BUILDING 5 TUKWILA, WA 98168 PH: 206-352-9466 EMAIL: ANTHONY@DEAMOR.COM PROJECT MANAGER: KPFF ENGINEERS CONTACT: JORA LEHRMAN, PROJECT MANAGER 1601 FIFTH AVENUE, SUITE 1600 SEATTLE, WA 98101 PH: 206-622-5822 EMAIL: JORA.LEHRMAN@KPFF.COM PROJECT DESCRIPTION DRAWING LIST GENERAL VICINITY MAP GENERAL NOTES 1. DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND WHAT IS CONTAINED IN ONE SHALL BE CONSIDERED TO BE INCLUDED IN BOTH. 2. THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS, PROJECT MANUAL AND ADDENDA (IF ANY). THE CONTRACT DOCUMENTS ARE CONSIDERED INCOMPLETE UNLESS ALL ELEMENTS LISTED ARE PRESENT. 3. IN THE CASE OF A CONFLICT BETWEEN ANY ASPECT OF THE CONTRACT DOCUMENTS AND ANOTHER, CONTACT THE ARCHITECT IMMEDIATELY FOR DIRECTION. 4. ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND ORDINANCES. IF A CONFLICT ARISES BETWEEN WHAT IS SHOWN IN THE CONTRACT DOCUMENTS AND AN APPLICABLE CODE, PROMPTLY NOTIFY ARCHITECT FOR DETERMINATION OF HOW TO PROCEED 5. DO NOT SCALE DRAWINGS 6. PERFORM EXCAVATION & FOUNDATION WORK IN CONFORMANCE WITH THE SOILS REPORT AND CONSTRUCTION DOCUMENTS 7. DRAWINGS INDICATE GENERAL & TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER, TYPICAL DETAILS SHALL APPLY. GOVERNING CODES 2015 IBC WITH WASHINGTON AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2015 IEBC WITH WASHINGTON STATE AMENDMENTS, ALTERATION LEVEL 1 (SECTION 503) T1.0 COVER SHEET & PROJECT INFO T1.1 ENERGY CODE POR OF NE 1/4 OF SEC 19-21-4 DAF - BEG AT NXN OF NELY MGN OF SW CAMPUS DR WITH SWLY EXTN OF SELY LN OF TRACT B OF THE RIDGE DIV 5 TH N 52-58-44 E ALG SD EXTN 402.20 FT TH S 25-07-48 E 746.05 FT TH S 64-52-12 W 100.00 FT TH S 25-07-48 E 459.69 FT TO TOP OF BANK OF EXISTING STORM DRAINAGE CHANNEL TH ALG SD TOP OF BANK S 17-52-21 W 136.20 FT TH S 38-30-56 W 143.11 FT TAP ON NELY MGN SD SW CAMPUS DR TH NWLY ALG SD MGN TO POB BUILDING 1 LEGEND SHOP DRAWINGS C COVER SHEET - SITE PLAN & SKYLIGHT PLAN VIEW D1 DETAILS - SKYLIGHT DETAILS S1 SCHEDULE - FLASHING & FASTENERSNORTHKING COUNTY AQUATIC CENTER - SKYLIGHT REPLACEMENT PERMIT SET STRUCTURAL CALCULATIONS CALCULATIONS ARCHITECTURAL A1.0 SITE PLAN A1.1 STAGING & SCAFFOLDING LAYOUT A2.0 ROOF PLAN PRODUCT DATA SHEET TNEMEC 650 SOUTHWEST CAMPUS DRIVE FEDERALWAY, WA 98023 HAZMAT: ALTERNATE ENVIRONMENTAL TECHNOLOGIES CONTACT: BRIAN HUNT, MA RA AHERA PROJECT DESIGNER 5129 EVERGREEN WAY, D9 EVERETT, WA. 98203 PH: (877) 232-9860, 425.232.9860 BRIAN@ALTERNATIVE-TECHNOLOGIES.COM PROJECT DESCRIPTION REPLACE EXISTING SKYLIGHTS WITH NEW SKYLIGHTS. SKYLIGHT REPLACEMENT ARE TO BE SIMILAR SIZE, WEIGHT, AND ATTACHMENTS. NO EXITING STRUCTURE WILL BE ALTERED. REVISION DATE DESCRIPTION AERIAL VIEW 20-101626-Planset-04-22-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Apr 22 2020 ISSUE DATE: CONTENTS: SCALE: DRAWN: CHECKED: PROJECT NO: SHEET: 2018020.000650 SW CAMPUS DRIVEFEDERAL WAY, WA 98023KING COUNTY AQUATIC CENTER -SKYLIGHT REPLACEMENTPERMIT SET CODE ANALYSIS JK JW T1.1 APRIL 20, 2020 ENERGY CODE ANALYSIS & 2015 WESEC FORM 2015 IBC WITH WASHINGTON STATE AMENDMENTS - CODE ANALYSIS ,2610.5 AGGREGATE AREA OF SKYLIGHTS THE AGGREGATE AREA OF SKYLIGHTS SHALL NOT EXCEED 331/3 PERCENT OF THE FLOOR AREA OF THE ROOM OR SPACE SHELTERED BY THE ROOF IN WHICH SUCH SKYLIGHTS ARE INSTALLED WHERE CLASS CC1 MATERIALS ARE UTILIZED, AND 25 PERCENT WHERE CLASS CC2 MATERIALS ARE UTILIZED. REVISION DATE DESCRIPTION OVERALL SKYLIGHT TO ROOF AREA TOTAL BUILDING FLOOR AREA = 62,140 SF TOTAL SKYLIGHT AREA = 9,212 SF PERCENT OF SKYLIGHT TO FLOOR= 15% SKYLIGHT REPLACEMENT AREA PERCENTAGES TOTAL EXISTING SKYLIGHT AREA = 9,212 SF SKYLIGHT REPLACMENT AREA = 7,416 SF 20-101626-Planset-04-22-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Apr 22 2020 A2.0 1 ROOF PLAN NO WORK IN THE PUBLIC RIGHT OF WAY ISSUE DATE: CONTENTS: SCALE: DRAWN: CHECKED: PROJECT NO: SHEET: 2018020.000650 SW CAMPUS DRIVEFEDERAL WAY, WA 980231" = 50'-0"KING COUNTY AQUATIC CENTER -SKYLIGHT REPLACEMENTPERMIT SET SITE PLAN JK JW A1.0 APRIL 20, 2020 1" = 50'-0"1 SITE PLAN NORTH REVISION DATE DESCRIPTION 20-101626-Planset-04-22-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Apr 22 2020 1. STAGING, STORAGE, & OFFICE LOCATIONS 2. STAGING, STORAGE, & OFFICE LOCATIONS 3. SCAFFOLDING LAYOUT ISSUE DATE: CONTENTS: SCALE: DRAWN: CHECKED: PROJECT NO: SHEET: 2018020.000650 SW CAMPUS DRIVEFEDERAL WAY, WA 980231/2" = 1'-0"KING COUNTY AQUATIC CENTER -SKYLIGHT REPLACEMENTPERMIT SET STAGING & SCAFFOLDING LAYOUT Author Checker A1.1 APRIL 20, 2020 REVISION DATE DESCRIPTION 1/2" = 1'-0"1 STAGING & SCAFFOLDING LAYOUT 20-101626-Planset-04-22-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Apr 22 2020 1.. DRAWINGS INDICATE GENERAL & TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER, TYPICAL DETAILS SHALL APPLY. ROOF PLAN NOTES:SLOPE DOWNSLOPE DOWNEXISTING PHOTOVOLTAIC PANELS -NO WORK EXISTING METAL STANDING SEAM ROOF -NO WORK EDGE OF BUILDING FLAT LOWER LEVEL ROOF -NO WORK SKYLIGHT BELOW -NO WORK REPLACE EXISTING SKYLIGHT WITH NEW SKYLIGHT C A ISSUE DATE: CONTENTS: SCALE: DRAWN: CHECKED: PROJECT NO: SHEET: 2018020.000650 SW CAMPUS DRIVEFEDERAL WAY, WA 98023As indicatedKING COUNTY AQUATIC CENTER -SKYLIGHT REPLACEMENTPERMIT SET ROOF PLAN JK JW A2.0 APRIL 20, 2020 1/16" = 1'-0"1 ROOF PLAN NORTH REVISION DATE DESCRIPTION 20-101626-Planset-04-22-2020-V1 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Apr 22 2020 16'-6 1/2" OD STEEL (WORKPOINT ON SLOPE)16'-6 1/2" OD STEEL (WORKPOINT ON SLOPE)11'-3 3/4" BAY25'-5" BAY(9) EQUAL BAYS @ 25'-5" = 228'-9"25'-5" BAY294'-4 3/4" OD STEEL (WORKPOINT)3'-8"OD - CLBATTEN/STEEL3'-10"CL BATTEN/STEEL3'-9 3/4"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL5'-1"CL BATTEN/STEEL3'-8"CL BATTEN/STEEL-OD45°SLOPE 45° SLOPE 45°SLOPE 45° SLOPEARCH. REF. =NORTHSKYLIGHT PLAN VIEW - (1) TOTALAC1/4" = 1'-0"ARCH. REF. =NORTH SITE PLAN1cNTSAC4D12D12D13D1TYP.TYP.4D12D12D11D1TYP.TYP.4D11D14D13D113D13D1SIM.2D1SIM.2D1SIM.2D1SIM.2D1SIM.2D1SIM.2D1TYP.TYP.2D1SIM.2D1SIM.TYP.TYP.111111ENGINEERED SUBMITTALGENERAL NOTES1.Translucent panels and related framing systems are manufactured by Kalwall Corporation. Installation is by DeaMor.2.These shop drawings are based on as built drawings from 1989 and BLOCK dimensions field verified by Deamor.3.Reference structural calculations for design criteria.4.Fasteners: All fasteners will be non-magnetic 300 series Stainless Steel where indicated. Steel fasteners will have acorrosion resistant coating. Fasteners are designed for a safety factor of 4 to 1. All exposed fasteners will be finishedto match the skylight framing.5.Flexible gaskets will be factory-applied to perimeter and batten extrusions under controlled conditions.6.Kalwall aluminum components to be of the following alloys and temper:Thermally Broken I-Beam Grid Core:6005-T5Perimeter & Batten Extrusions:6063-T6Flashings:5052-H32 and 5005-H347.Finish: Interior and exterior aluminum translucent panel system components will have manufacturer's standardfactory-applied high-performance fluoropolymer coating to meet performance requirements of AAMA 2604. Color: KCRF Gray 808.Kalwall panels and framing will be sealed per details and panel manufacturer's instructions.9.Kalwall translucent panels are 2-3/4" thick and consist of glass fiber reinforced polymer faces bonded under controlledheat and pressure to a mechanically interlocked thermally broken I-beam grid core. KALWALL ICC Evaluation ReportESR-2464.Grid pattern will be a nominal 8"x20" Shoji symmetrical about the centerline of each panel.NFRC Certified Products Directory Listing: KWC-M-1-00075-00001Exterior face sheet:Crystal, SW, 0.070" thickInterior face sheet:Crystal, S-171, 0.045" thickFlame Spread: 50Smoke Developed: 250Light Transmission:15%Panel U-Value:0.14System U-Value:0.21S.H.G.C.:0.17Sheet Index:Cover/Plans: CDetails: D1Schedule: S1Weyerhaeuser KCAC 650 SW Campus Drive Federal Way, WA 98023 Translucent Roof Assemblies King County Parks and Recreation PM - Matthew Perkins c. 206.945.8886 FM - Mike Dunwiddie c. 206.954.8529 ARC Architects Jeff Wandasiewicz ph. 206.322.332220016(503)284-6799 (360)574-3449Job6210 S. 11th St. Ridgefield, WA 98642 Associates, Inc. FAX: (360)574-3487 Architect: FIELD: OFFICE: Customer: DeaMor OFFICE: Skylight Replacement JC/MP3/17/201SKYLIGHT ENGINEERSTAMPJC/MP4/3/20CREVISIONS1REVISE AND RESUBMIT - ENGINEERED1DERETSIGERR E ENIGNELANOISSEFO RPNOTGHSAWFT ATSEXPIRES: FEB. 15, 201849843NIOEANEEH S PYEMA.EXPIRES: 02/15/202220-101626-Planset-04-22-2020-V1RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTApr 22 2020 #14 x 1" SH SCREWS- BY KALWALL#14 x 2 1/2" SH SCREWS- BY KALWALL1/8" x 3/8" BCF TAPE- BY KALWALLCONT. KALSEAL BEAD BY- KALWALLCONT. 3/8" x 3/8" FOAM TAPE - BYKALWALL3 1/4" ROOF BATTEN#14 x 2 1/2" SH SCREWS- BY KALWALL1/8" x 3/8" BCF TAPE- BY KALWALLEXISTINGHSS STEEL3/16Ø BCF TAPE- BY KALWALLATTACH AT TOP ANDBOTTOM WITH DOW 7583/16"3/16"CL BATTEN/STEELCL BATTEN/STEELOD STEEL (WORKPOINT)CL STEEL1 3/4"EXISTINGHSS STEEL1 3/4"F117@ 24" O/CF107@ 24" O/CKFEFCONTINUOUS KALSEAL BEAD BY- KALWALL#14 x 3/4" SH SCREWS- BY KALWALL (12" OC)CONTINUOUS 3/8" x 3/8" FOAM TAPE- BY KALWALL3/16"Ø BCF TAPE- BY KALWALLOD STEEL (WORKPOINT)OD STEEL (WORKPOINT)2 1/4" KCRFPAINTOVERLAPS12:1245°F107(1) EA SIDE OFPANEL AT HSSRFRCEXISTING HSS STEELF117@ 24" O/C2"RSINSRMINSTALLER NOTE!TYPICAL AT THE TOPS OF ALL STEEL TUBE SUPPORT LOCATIONSCOATING APPLIED TO TOP OF STEEL PRIOR TO INSTALLATION OF KALWALL PANEL:- TNEMEC F.C. TYPOXY SERIES 27TSURFACE PREP:- CLEAN THE STEEL SURFACE WITH A CLEAN RAG AND ISOPROPYL ALCOHOL.- IF ADDITIONAL TEXTURE IS REQUIRED TO GAIN ADHESION OF THE TNEMEC COATING, USE HAND-HELD WET SPONGE WITH MAXIMUM 80-GRIT SANDPAPER AND RUN LIGHTLY OVER THE SURFACE.- DO NOT USE ABRASIVE BRUSHES OR GRINDERS ON THE PAINTED SURFACE!- LEAVE THE EXISTING MATERIAL IN PLACE TO THE GREATEST EXTENT POSSIBLE.APPLICATION:- APPLY PAINT WITH ROLLER TO COVER TOP SURFACE OF STEEL TUBE RAFTERS AT EACH KALWALL BATTEN ONLY.S3RMAF6"3"ARCH. REF. =RIDGE (PEAK) DETAIL1D16"=1'-0"ARCH. REF. =EAVE DETAIL2D16"=1'-0"ARCH. REF. =TYP. BATTEN DETAIL3D16"=1'-0"ARCH. REF. =RAKE DETAIL4D16"=1'-0"F515@ 24" O/CS3- UNDER EXTRUSIONEXISTING ROOFING/CURBFLASHING TO REMAINEXISTING 1/8" THICK STEEL PLATEx CONT.4"1 1/2"4"- UNDER EXTRUSION- UNDER EAVE APRONTOP OF HSS AT RAKESAND BATTENS2"2"S3- UNDER EXTRUSIONEXISTING END WALLSTEEL HEADERRM#14 x 3/4" SH SCREWS- BY KALWALL (12" OC)KSMETAL CLADDING VERTICALWALL AT 'SIM" CONDITION1SH3SH211DETAIL OMMITTED1S3- BEHIND SHIMSTNEMEC COATINGPER INSTALLERNOTE THIS SHEETS3TNEMEC COATING PERINSTALLER NOTE THIS SHEET- UNDER EXTRUSIONSheet Index:Cover/Plans: CDetails: D1Schedule: S1Weyerhaeuser KCAC 650 SW Campus Drive Federal Way, WA 98023 Translucent Roof Assemblies King County Parks and Recreation PM - Matthew Perkins c. 206.945.8886 FM - Mike Dunwiddie c. 206.954.8529 ARC Architects Jeff Wandasiewicz ph. 206.322.332220016(503)284-6799 (360)574-3449Job6210 S. 11th St. Ridgefield, WA 98642 Associates, Inc. FAX: (360)574-3487 Architect: FIELD: OFFICE: Customer: DeaMor OFFICE: Skylight Replacement JC/MP3/17/201SKYLIGHT ENGINEERSTAMPJC/MP4/3/20D1DERETSIGERR E ENIGNELANOISSEFO RPNOTGHSAWFT ATSEXPIRES: FEB. 15, 201849843NIOEANEEH S PYEMA.EXPIRES: 02/15/202220-101626-Planset-04-22-2020-V1RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTApr 22 2020 SILICONE/RUBBER/PLASTIC SCHEDULESPECIAL NOTATIONCOLORDESCRIPTIONNO.FASTENER SCHEDULEPT/ACCMATL.COND.LG.TYPESIZEIMAGENO.FLASHING SCHEDULE.040" THK. ALUMINUM EAVE FLASHING5052-H32EFHEX WASHERHEAD1/43/4"B3/4"300SERIESSTAINLESSSTEELF107CW1DOW 758 SILICONEX CONTINUOUSWHITESEAL UNDER EXTRUSION & FLASHING AT CURBS3BLACKRMN/APROTECTO SEAL 45 FOIL FACED ROOFINGMEMBRANEHEX WASHERHEAD1/42"B2"300SERIESSTAINLESSSTEELF117CW11 11/16"1 3 / 1 6 " FINISH SURFACE .040" THK. ALUMINUM EAVE APRON FLASHING5052-H32AF4"5 1/2"FINISHSURFACE.040" THK. ALUMINUM RIDGE FLASHING5052-H32RF1/2"1/2"8 1/16"8 1/16".032" THK. ALUMINUM SAME SUPPORT5052-H32RS2 1 / 4 "2 1/4".063" THK. ALUMINUM RIDGE COVER FLASHING5052-H32RC3 1/2"3 1/2"90°MILL.040" THK. ALUMINUM RAKE FLASHING5052-H32KFFINISHSURFACEFINISHSURFACE 6 1/16"45°96°6 5/16"2 3/4"2 3/4"38°38° 18°7"51°.032" THK. ALUMINUM RAKE SAM SUPPORT5052-H32KS2 5/16"6 1/8"1 1/2"2°MILL3 7/8"1/2 "DOW RIGID 1" INSULATION BOARD- CONTINUOUS--INS1AT MULTIPLE LAYERS: TAPE PERIMETER AND SEAMS- NOTCH AT WEEP VALVESATTACH TO JAMB NEAR HEAD AND SILL - AS REQUIRED--1/4" THICK PLASTIC HORSESHOE SHIMSH3--1/8" THICK PLASTIC HORSESHOE SHIMSH21Sheet Index:Cover/Plans: CDetails: D1Schedule: S1Weyerhaeuser KCAC 650 SW Campus Drive Federal Way, WA 98023 Translucent Roof Assemblies King County Parks and Recreation PM - Matthew Perkins c. 206.945.8886 FM - Mike Dunwiddie c. 206.954.8529 ARC Architects Jeff Wandasiewicz ph. 206.322.332220016(503)284-6799 (360)574-3449Job6210 S. 11th St. Ridgefield, WA 98642 Associates, Inc. FAX: (360)574-3487 Architect: FIELD: OFFICE: Customer: DeaMor OFFICE: Skylight Replacement JC/MP3/17/201SKYLIGHT ENGINEERSTAMPJC/MP4/3/20S1DERETSIGERR E ENIGNELANOISSEFO RPNOTGHSAWFT ATSEXPIRES: FEB. 15, 201849843NIOEANEEH S PYEMA.EXPIRES: 02/15/202220-101626-Planset-04-22-2020-V1RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTApr 22 2020