Loading...
06-102779THIS CARD IS TO PEMAIN ON-S!"TE CITY OF4A �,ommunity Deveiopmcnt Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT #: 06-102779-00-SG Owner: DEL NORTE LLC Address: 1800 S 344TH ST FEDERAL WAY, WA 98003-6841 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence On -going inspections are logged on the back of this card. Footings/Setback (4110) Final - Electrical (4055) Final - Sign (4085) Approved to place concrete 144Approved Approved By Date By Date By Date Attachment (4010) Approved By Date JUN 0 6 ?.nml SIGN PERMIT APPLICATION OW OF FEDERAL VVA�PPLICATION NUMBER: - Q Z - -0' "The foil owin is rB uired information -- Please orint fin ink or a** PROPERTY• • 1$'QO SITE ADDRESS: 1'6 0 0 S. 3 4 4 t h S t. ASSESSOR'S TAX/ PARCEL #, 2 12 10 4 9 0 3 6 PROJECT• • TYPE OF PROJECT (Check all that apply): XAPERMANENT ❑TEMPORARY ❑NEW ❑ALTERATION ❑REFACE ❑EXEMPT ❑ ELECTRICAL (To attach to existing J-box) ❑ ELECTRICAL (New/altered circuit & j-box added) C, (separate permit is required) NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: 3 PROJECT DESCRIPTION (Provide detailed description): I'a_q-t;; •-14•---R70-rl'umem-tD —( ) W all , r7irQ� rtin,na 2`C� r--Stand--- BUSINESS/TENANT NAME: Del Taco PEOPLE• • SIGN OWNER: NAME: DAYTIME PHONE: Del Taco MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): 1$00 S. 344th St. Federal Way CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: EXPIRATION DATE: (Required) -- -- / / CONTRACTOR: NAME: Plumb Signs Inc. MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): 909 S. 28th St., Tacoma, 98409 19 98 105516-00 BL -- -- CONTRACTOR'S REGISTRATION NUMBER: (Copy required) PLUMBSI077QS APPLICANT: NAME: Connie Guffey MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): 909 S. 28th St., Tacoma, 98409 CONTACT FOR THIS PROJECT: TYPE/PURPOSE OF EVENT: DATE OF INSTALLATION: ❑ PROPERTY OWNER D APPLICANT CONTRACTOR DATE OF REMOVAL: DAYTIME PHONE: (253 )473-3-323 ( 253 472 -3107 EXPIRATION DATE: 11 /10 / 07 DAYTIME PHONE: (253 )473 3323x10 EVENING PHONE: FAX NUMBER: ( 25)472-3-107 E-MAIL ADDRESS: con ie@alumbsigns.co TEMPORARY SIGN TYPE: ❑ BANNER ❑ INFLATABLE ❑ PORTABLE ❑ SEARCH LIGHTS/BEACON NUMBER OF EACH TYPE: PROJECT, PROPOSED NUMBER OF WALL SIGNS: .3 PROPOSED NUMBER OF FREE STANDING SIGNS: 1. TOTAL ESTIMATED PROJECT COST: $ NUMBER OF TENANTS/BUSINESS SPACES QN PROPERTY: 5+ PERMANENT FREE STANDING: NUMBER OF EACH TYPE: , POLE ❑ TENANT DIRECTORY PERMANENT BUILDING MOUNTED:-6 AWNING )IC Ei' ❑ CANOPY ❑ CENTER IDENTIFICATION (CID) ❑ CHANNEL LETTERS NUMBER OF EACH TYPE: o MARQUEE n OTHFR o PROJECTING o TENANT DIRECTORY NUMBER OF EACH TYPE: FREE $Af4whG SIGN TYPE SIGN AREA (SQ. FT.) WIQfR7[-H>~ GHT X # OF C�5 i UMINATED?: NO INT EXT REFACE? YES NO PART OF CID SIGN? TOTAL SIGN HEIGHT FT BASE HEIGHT FT I I• I 1 C STREET FRONTAGE (FT): _ BUILDING MOUNTED ILLUMINATED? SIGN AREA (SQ. FT.) BUILDING EXPOSED BUILDING SIGN TYPE NO INTERNAL EXTERNAL WIDTH X HEIGHT X # OF FACES ELEVATION N S E W FACE (SQ.FT. A B C p D E DISCLAIM ER/SIGNATU RE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and further, that I am authorized by the owner of the above premises to perform the work for which the permit application is made NAME/TITLE: SI NATUAx NAME (Print) E PRINT DATE: -��� L FOR OFFICE USE ONLY: ZONING DESIGNATION: _COMP PLAN DESIGNATION: FREE STA ING SIGN AREA PERMI ED: AREA PROPOSED: STREET FRONT NUMBER SIGNS ALLOWED: BUILDING MOUNTED SIGN a" a' AREA PERMITTED: r 77, - ��0 77 AREA PROPOSED: o C_ = -3.9 LARGEST BUILDING FACADE: 412-15— NUMBER OF SIGNS ALLOWED: LAND USE APPROVER INITIALS: < DATEI����� STRUCTURAL APPROVER INITIALS: DATE: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: COMMUNITY DEVELOPMENT SERVICES • 33325 BTH AVENUE SOUTH • PO BOX 9718 • FEDERAL WAY, WA 98063-9718 • 253-835-2607 • FAX: 253-835-2609 rlTv of Federal July 11, 2006 Ms. Connie Guffey Plumb Signs, Inc. 909 South 280' Street Tacoma, WA 98409 CITY HALL Way 33325 8th Avenue South Mailing Address: PO Box 9718 Federal Way, WA 98063-9718 (253) 835-7000 www. cityoffederalway.. com Re: File #06-102779-00-SG; SIGN PERMIT REVIEW Del Taco @ Federal Way Marketplace; 1800 South 3441h Street, Federal Way Dear M uffey: I reviewed the information that was resubmitted on July, 3, 2006, addressing the items from my initial review. The wall signage as proposed has been approved. However, the directional signs and the menu board do not meet the criteria for an exemption from a permit. ■ With regard to the directional signs, per Federal Way City Cade (FWCC) Section 22- 1599(d)(2)(e), "...logos shall not comprise more than 20% of:the total sign area." It appears that the proposed signs do not meet this requirement. ■ In order for the menu board to be exempt, per FWCC Section 22-1599(d)(2)(p), it may not, "...exceed 32 square feet per sign face and a maximum height of five feet...." The menu board proposed exceeds the allowed maximum height and area. Please submit drawings with a modified design demonstrating that the signs meet the requirements for exemption, or show them removed from the project. Provide two copies of any revised drawings along with the enclosed Resubmittal Form. If you have any questions, feel free to call me at (253) 835-2607. Si re y, Gra Skidmore Development Specialist enc: Resubmittal Form c: K.L. Cimmer, Lead Development Specialist Doe 1 D 37129 CITY OF �. Federal June 28, 2006 Ms. Connie Guffey Plumb Signs, Inc. 909 South 28'h Street Tacoma, WA 98409 CITY HALL Way 33325 8th Avenue South Mailing Address: PO Box 9718 Federal Way, WA 98063-9718 (253) 835-7000 www.cityoffederalway.com Re: File #06-102779-00-SG; SIGN PERMIT REVIEW Del Taco @ Federal Way Marketplace; 1800 South 3441h Street, Federal Way Dear Ms. Guffey: I have performed an initial review of the application materials for Del Taco's signage to verify compliance with applicable land use requirements. In order for the review to continue, the following issues must be addressed: The Federal Way Marketplace site has an approved sign permit for the maximum allowed freestanding signage for the entire project, including the independent "outparcels." Therefore, the monument sign proposed for this project is not allowed. Please revise drawings to remove the sign from the application. The site plan depicts a menu board to be placed in the drive-thru area. It is unclear that the proposed design meets the criteria for an exempt sign. Please submit a drawing detail of the menu board for clarification. The application form contains conflicting information about the number of signs proposed for this project. Please clarify the actual number of proposed signs, provide drawing details for each (including exempt signs) and include all signs on the site plan. Please provide the information necessary to address the items above, including two copies of any modified drawings, and resubmit along with the enclosed Resubmittal Form. If you have any questions, feel free to call me (or another Development Specialist if I am unavailable) at (253) 835-2607. XIy, 4 S�u Vk.-- Grace Skidmore Development Specialist enc: Resubmittal Form K.L. Cimmer, Lead Development Specialist Doc LD. 36978 F;4"ME LU z LLJ Q I — co T Cl) a FINAL SIGN INSPECTION is REQUIRED in order to receive sign registration number. Call 253-835- -`�- 3050 to schedule inspection. f SITE PLAN. SCALE: 1' = 30•-0" No sign shall project above the `�f roofline of the exposed building face to which it is attached. (FWCC. 22-1601(13)(2)) Attachment inspection required: provide access for inspection prior to covering with face panel FILE In LAI Lem 6 .31. sF �r •� X ? ' y x -7' 7~ ctxLMrT') r� rr�a C� KEY Al D/F 5-0" X 8'-0- MONUMENT SIGN @ 7'-10"OA H. WITH READER BOARD. A2 MULTI II A -ON SIGN. (DESIGN TBD) Bti S/F FORMEDI LOGO WALL SIGN @ 24.3 SQUARE FEET. S/F FORMED LOGO SIGN WALL @ 24.3 B2 SQUARE FEET. 0_.R3. S/F FORMED LOGO SIGN WALL @ 24.3 SQUARE FEET. D!F DIRECTIONAL SIGN; `DRIVETHRU" @ 4.0 SQUARE FEET D/F DIRECTIONAL SIGN; 7HANK YOU/ DO NOT EN fff' @ 4.0 SQUARE FEET. 0 S/F MENU BOARD & SPEAKER CITY OF FEDERAL WAY DEPT. OF COMMUNl7Y DEVELOPMENT PERMIT: 06-102779 - 00 SG ADDRESS: 1800 S 344th St PROJECT: Signs OWNER: Del Taco DATE: 6/6/06 DATE 3UBMITTED_Z� QAT APPROVED �., .1. r APPROVED BY Separate electrical permit required FINAL INSPECTION REQUIRED UPON COMPLETION Dte OF WORK RECEIVED JUN 0 S Z006 CITY of FEDERAL WAY BUILDING DEPT, ro O O O S O CV O O X ¢ ?'' z X O � � CU J W W IL J Z Z LJJ O � LU C O E O —oz�am` c v v m �a2 $E v` Z 0 0 CV Q D10 vM *ern 0ZONo > M C— !? 0 o .A o NNv o -ILO w m O o 30 L1J Z W Q F— Lo T ■ SITE FLAN SCALE: 1" = 30'-o' In Ly LL 6 v */it Z 6 t Ew erg ag� KEY S/F FORMED LOGO WALL SIGN @ 24.3 SQUARE FEET. S/F FORMED LOGO SIGN WALL @ 24.3 SQUARE FEET. S/F FORMED LOGO SIGN WALL @ 24.3 SQUARE FEET. D/F DIRECTIONAL SIGN; "DRIVETHRU" @ 4.0 SQUARE FEET �. D/F DIRECTIONAL SIGN; 7HANKYOU/ DO NOT ENTER" 9 4.0 SQUARE FEET. @ S/F MENU BOARD & SPEAKER 0 6-102779 RESUBMITTED JUL 4 3 2006 CITY OF FEDERAL WAY BUILDING DEPT. 0 z z x <c x ¢ Q cc d< J W Z W = Z C Lu uj a a c ca Uo E »_ o 01 m � 'v — m • � or'� $ E `o U s_a0 a m U m= ma c ° > 01 9 c) v O aoa„a`a� O u„ o o a� o nl cot p._�H> o w = Z u r a o 3 U TOTAL LED BORDER: 285' TOTAL WAVE BACKING: 104' TOTAL RIGHT ELEVATION SCALE: 1/8" = 1'-0" FRONT ELEVATION SCALE: 1/8" = 1'-0" 81� 4 3"x8`-10" SIGN f32� 4 3"x8`-10" SIGN nivni ,3 to WALL AREA — SOUTR ELEVATION: 18' X 61'11" = 1,115 SQ. FT. X 7%= 78 SQ. FT. ALLOWED SIGN AREA — SOUTH ELEVATION: DEL TACO: 4'3" X 8' 10" = 38 SQ, FT. PROPOSED w 0 0 N N Cl �4a AREA - WEST ELEVATION: i' 2" = 651 SQ. FT. X 7% = 46 SQ. FT. ALLOWED REA— WEST ELEVATION: LCO: 4'3" X 8' 10" = 38 SQ. FT. PROPOSED RECEIVE® JUN 6 6 2006 CITY OF FEDERAL WAY BUILDING DEPT. U CL S 0 CD r45 I I C o 0 ` , t a> �;� bw a m_ U TOTAL LED BORDER: 285' TOTAL WAVE BACKING: 104' TOTAL LED BORDER LEFT ELEVATION SCALE: 1/8" = 1'-0" 0 . 4'-3"x8;;10" SIGN REAR ELEVATION SCALE: 1/8" = 1'-0" - — 0 r WALL AREA — NORTH tLhVA 11UN: 18' X 61'11" = 1,115 SQ. FT. X 7%= 78 SQ. FT. ALLOWED SIGN A R F A — NORTH 1;LEVATION' DEL TACO: 4'3" X 8' 10" = 38 SQ. FT. PROPOSED �1 � o � .d���d jf l.�E/G�i' •� � g it f5a g EL U am N RECEIVE® a A Z JUN 0 6 2006 c z a e ma CITY OF FEDERAL WAY U z BUILDING DEPT.° � o V m� �vF a5 0 U B'-10" CAS ELEVATION VIEW a'_1o" CA1 ELEVATION VIEW 7' FORMED LEXAN FACE WITH SECOND SURFACE PAINTER GRAPHICS AS FOLLOWS: SUN: PMS 123 YELLOW MOUNTAIN: PMS 368 GREEN BACKGROU10 & LETTER FACES: PMS 186 RED LIFTING CUP UL LISTED ELECTRICAL DISCONNECT SWITCH FORMED LEXAN CABINET PAINTED TO MATCH PMS 185 RED. FLUORESCENT ILLUMINATION; U.L. LISTED/ PROVIDE DISCONNECT SWI PAN-HEAO FASTENING SCREW @ 2'-O' O.C. (MIN.); CONTINUOUS WEATHER STRIPPING AROUND PERIMETER FORMED LEXAN FACE FORMED RACEWAY W/.063 ALUMINUM COVERS BALLAST W/ SHEET METAL SUPPORT 3/8" X 6" LAG SUPPORT (INTO — BLOCKING OR STUD); MIN. 4 REQ'D FORMED WHITE LEXAN CABINET W/— EXTERIOR PAINTED PMS 185 RED (SATIN FINISH); PROVIDE WEEP HOLES AS REQ'D 01A- SIDE VIEW 3/4" -. 8114" SIDE VIEW RECEIVE® JUN 0 6 2006 61 62 as S/F FORMED CLOUD SIGN cr 24.3 SQUARE FEET SCALE: 112" = 1'-0' ,TY OF BUILDING �EpTWAY OIim w Ln o z 0 0 0 n 0 o 0 o o 0 0 to 0 0 0 o axC ¢ z x � x a o CJ J W F � w J w z ui �w Lu o Lu C O 10 02 —oZ,''0 o2 n--vavo� z sa'`as�a U:iydum�._ � `o E`3v � �2gmE�a c O vL 000 m OmCmzc0 6 m mL m—Si 3U MOUNTING BI #0 FLAT SCREW ( D.C. (Mip BONATE IEAD _.. 2'-0" O.C. (MIN.) BORDER LED DETAIL FULL SIZE W STANDARD SPECIFICATIONS 'SLOAN' LED RED LIGHTING SYSTEM. ALL ELECTRICAL COMPONENTS TO BE UL LISTED. ATTACH TO. WALL AS REQUIRED. VARIES VARIES - 10'-0" MAXIMUM SECTION - -.7 riL- r..r�; ..- _:�•�-'I N 2'-0" O.C. (MIN.) STANDARD SPECIFICATIONS 1r WAVE FACE: ROUTED .OG3 ALUMINUM WITH FIRST SURFACE APPLIED ACRYLIC POLYEURETHANE PAINT AS FOLLOWS: TOP WAVE: TO MATCH PMS 195 RED BOTTOM WAVE: TO MATCH PMS 375 GREEN CONNECTOR PIECE. TO MATCH BUILDING COLOR OU REC EIV En JUN D 6 2006 S/F ALUMINUM WAVE ACCENT _ _ G1TC OF FEDERAL WAY SCALE: 1" =1'-O" BUILDING DEPT. n CD r O O FL 0 Z [D 0 0 O Cy 0 e O OtE x Q z C7 J W LL J W Z uj wLI w a s 0 c v o � E °`oz�'6 `w 0 C O O g C Y m'C a O d= Uo�o�s�� c U U 9 3 N ��oE v v p on ` O CN o£ n�-= OU �_ m 2 L_ 0 n v ' rn c u 2 a° d p E L O m F p L Lo' 2 U 0 3 U F U U N a T 0 Ury p a� � m � a o� Z Z �G Wa c � Z N Q ?n'° _ - N Z a p z o. � � tia Q 8 j 1/4" 1/4 1 1 3 r DEL 1 FACE: FORMED LEXAN W/ SUNG UARD WITH SECOND SURFACE GRAPHICS, LOGO=.52 S.F. CABINET: ALUMINUM) ACRYLIC POLYURETHANE TO MATCH BENJAMIN MOORE 302 CREAM ILLUMINATION: 800 MA FLOURESCENT ILLUMINATION/ TO BE U.L_ LISTED DIRECTIONAL: 1'3" X 2'8" = 3.33 SQ. Q. FT. ALLOWED LOGO: — `- 9" X 8" _ .50 SQ. FT. PROPOSED ELEVATION VIEW D/F INTERNALLY ILLUMINATED DIRECTIONAL SIGN SCALE.1" = 1'-0" 3 SIDE A SIDE B SIDE VIEW x 0 M 8 1,'4, AM (2) 800 MA FLUORESCENT LAMPS 0 EESB 424-13U 1.4 AMS BALLAST L PLATE TO BE ASTM A36 1/8 3/8" X 6" X 6" W/ (4) 3/8- DIA. ALL -THREAD BOLTS J-BOX W/ DISCONNECT SWITCH: LOCATED 6" MIN. FROM GRADE — 3" X3"SQUARE TUBE FINISHED GRADE (VARIES) a :a CONCRETE. • FIVE (5) SACK MIX WITH 3/4" MAX, a p • �' ' '� AGGREGATE. ULTIMATE COMPRESSIVE a, STRENGTH OF 2000 PSI AT 28 DAYS. 1'-6" ELEVATION VIEW 4 03 ".1 v a�. �•'•c-, D a t qp, G,a :d9••P •o- •' e •'' ,fl' P � •9' fl SIDE VIEW D/F INTERNALLY ILLUMINATED DIRECTIONAL SIGN STRUCTURAL DETAIL SCALE: 1" = 1'-0" T SPECIFICATIONS: PAN -FORMED LEXAN WITH SUNGUARD TO HAVE SECOND SURFACE GRAPHICS AS FOLLOWS: BACKl'ROUND- L4CRYL 400 TO MATCH PMS 186 RED SUN- 3630-25 YELLO W {VINYL) MOUNTAIN- VTO670 GREEN {VINYL) COPY- PAINT WHITE CABINET TO BE ALUMINUM EXTRUSION PAINTED TO MATCH BENJAMIN MOORE 302 CREAM, ILLUMINATION TO BE 800 MA FLOURESCENT AND TO BE U.L. LISTED WFfH APPROVED SHUTOFF SWITCH. ALUMINUM BASE TO BE TEXCOATED AND PAINTED TO MATCH BENJAMIN MOORE 302 CREAM. EACH DISPLAY = 4.6 SQUARE FEET NOTE: "DEL TACO" COPY & LOGO OCCUPgg q N( M JUL 2 0 2006 CITY OF FEDERAL WAY pi III nING ❑EPT- m v o 0 0 o 0 077 z x ¢ a O co J w z W = Z c ULu a R a�o�E`° z v a `m U C ° U m " U�os�v v -6 n Lo O O c'o°a6 N Q° € na N () ° c m Z c ,°0 � W o„u�'ga °I ° ELECTR END AP (ADJUS MAIN M L S r ALUMINUM CONSTRUCTION WITH INTERNAL FLUORESCENT ILLUMINATION. PAINTED CARDINAL #T009-BG01 ALMOND 90% GLOSS POWDER TYPE PO IL T.G.I.C. MENU PANELS SHOWN ABOVE BASED ON A STANDARD INDIVIDUAL SIZE 4 7/16" x 241/4" 32 SQUARE FEET. D1 INTERNALLY ILLUMINATED MENU DISPLAY SCALE: 1/2" = V-0" - 1'-0" MIN. i r OCB PLAN VIEW @ MENU BOARD & OCB SCALE: 3/16' = 1'-0" NOTES. V-0" MIN. PUS ]ON EVERYTHING FROM LOOP SENSOR. THE LOOP SENSOR SHOULD BE DIRECTLY IN FRONT OF THE OCB. THE OCB SHOULD BE PARALLEL TO THE DRIVE THRU LANE 7 NOT BLOCK THE MENU BOARD. THE OCB SHOULD BE AT LEAST 12" FROM THE CURB. THE BOLLARD SHOULD BE POSITIONED TO PREVENT DAMAGE FROM AUTOMOBILES. MENU BOARD THE MENU BOARD SHOULD BE ANGLED BETWEEN 15 AND 45 DEGREES FROM THE CURB FOR OPTIMAL VIEWING. IF THE OCB BLOCKS THE MENU BOARD, EITHER THE OCB OR THE MENU BOARD WILL NEED TO BE MOVED. THE LOOP SENSOR MUST STAY IN FRONT OF THE OCB. THE IDEAL DISTANCE FROM THS OCB TO THE MENU BOARD IS 10 TO 15 FEET. THE EXTENDERS SHOULD BE AT LEAST 12" FROM THE CURB. DO'S & DON'TS: DO MAKE SURE THE CUSTOMER CAN VIEW BOTH THE MENU BOARD AND THE OCB EASILY. DON'T LOCATE ANYTHING WITHIN 12" OF THE DRIVE-THRU LANE WITHOUT PROTECTING IT FROM MIRRORS. R q �o O o 00 o you o C) x x xQ z J o C3 J w J Lu Z W �W W 0 cw�•'u E° oo`z�'� a H c °coo E c �m2 nEo w ° c U vu =„= E p fio `w„c- o o„o5�vo CV O o c m Z 9 v rnd �a°w 5 0 tit a `0 3 U Iz JUL F NG DEPT