21-101125-UP-Drawings Arch-07-26-21-V2DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1AG1.0
ARCHITECT
GRAVES + ASSOCIATES
BEN CHILDS
3110 RUSTON WAY SUITE 'E'
TACOMA, WA 98402
T: (253) 272.4212
E: BCHILDS@GRAVESASSOC.COM
STRUCTURAL ENGINEER
DRAWING INDEX
ARCHITECTURAL GENERAL
AG1.0 COVER SHEET AND NOTES
AG1.1 FWRC CODE COMPLIANCE INFORMATION
AG1.2 FWRC CODE COMPLIANCE INFORMATION
AS1.0 SITE PLAN
AS1.1 SITE PLAN: BUILDABLE LANDS DIAGRAM
AS1.2 SITE PLAN: CPTED
A1.00 EXTERIOR ELEVATIONS: PODIUM
A1.01 EXTERIOR ELEVATIONS: PODIUM
A1.02 EXTERIOR ELEVATIONS: PODIUM
A1.03 EXTERIOR ELEVATIONS: PODIUM
A1.04 EXTERIOR ELEVATIONS: PODIUM
A1.05 EXTERIOR ELEVATIONS: PODIUM
A1.10 MODULATION DIAGRAM
A1.20 ENLARGED PLANS: PODIUM AMENITY AREAS
A1.21 ENLARGED PLANS: PODIUM AMENITY AREAS
A1.30 SECTION: PODIUM
A1.40 PODIUM PERSPECTIVES
A2.00 EXTERIOR ELEVATIONS: QUAD
A2.01 EXTERIOR ELEVATIONS: QUAD
A2.10 PLAN: QUAD PLAN, TYP., MODULATION DIAGRAM
A3.00 EXTERIOR ELEVATIONS: RETAIL/COMMERCIAL
A3.01 EXTERIOR ELEVATIONS: RETAIL/COMMERCIAL
A3.10 MODULATION DIAGRAM
A4.00 EXTERIOR RESIDENTIAL TRASH ENCLOSURE: PLAN,
EXTERIOR ELEVATIONS & DETAILS
A4.01 EXTERIOR COMMERCIAL TRASH ENCLOSURE: PLAN,
EXTERIOR ELEVATIONS & DETAILS
A4.02 PODIUM INTERIOR TRASH ENCLOSURE: PLAN
A5.00 SITE PHOTOS
SURVEY
SHEET 1 OF 1 SURVEY
2002 FEDERAL WAY MIXED-USE
OWNER / OWNER'S REP
PROJECT INFORMATION
MAP / TAX LOT LOT SIZE
912940-0010, 912940-0020, 8.33 ACRES
912940-0030, 912940-0040,
912940-TR-A
CONSTRUCTION TYPE TYPE 1A, VB CONSTRUCTION
PROPOSED OCCUPANCY R-2, B, S-2
BUILDING SETBACKS FRONT SETBACK = 0 FEET
SIDE SETBACK = 0 FEET
REAR SETBACK = 0 FEET
MAXIMUM BUILDING HEIGHT 65 FEET
FIRE SPRINKLER NFPA-13 (PODIUM & RETAIL)
NFPA-13R (QUADS)
PROJECT DESCRIPTION
NEW CONSTRUCTION OF A MIXED-USE DEVELOPMENT CONSISTING OF
APPROXIMATELY 233 UNITS WITH COMMERCIAL RETAIL SPACE AND
ASSOCIATED PARKING.
CIVIL ENGINEER
PROJECT LOCATION
FEDERAL WAY, WA,
X MARKS THE SPOT, LLC
BRETT JACOBS
2711 W. VALLEY HIGHWAY, SUITE #200
AUBURN, WA 98001
T: (206) 793.5393
eMAIL : BJACOBSEN@FNW-INC.COM
NAVIX ENGINEERING
JOE TAFLIN, P.E.
11235 SE 6TH STREET, SUITE 150
BELLEVUE, WA 98004
T: 425.458.7900
E: JOE@NAVIXENG.COM
CT ENGINEERING
CRAIG ROBERTS, SE
180 NICKERSON STREET, SUITE 302
SEATTLE, WA 98109
T: (206).285.4512 EXT. 304
E: CROBERTS@CTENGINEERING.COM
LANDSCAPE ARCHITECT
THOMAS RENGSTORF ASSOCIATES
BRIAN STARK, RLA
811 FIRST AVENUE, SUITE #400
SEATTLE, WA 98104
T: 206.682.7562
E: BSTARK@TRENGSTORF.COM
SYMBOL LEGEND
1
NAMEROOM
100
A3.0
1
A3.6
1
4
3
2
1 A7.0
1
WINDOW TYPE LETTER
EXT. WINDOW TYPE SYM.
SPECIFIC DETAIL NO.
INTERIOR ELEVATION SYMBOL
DRAWING NUMBER
SHEET
SHEET
DETAIL NO. OR LETTER
DETAIL SYMBOL
SHEETDETAIL NO. OR LETTER
SECTION SYMBOL
DOOR I.D. SYMBOL
DOOR NUMBER
ROOM NAME
ROOM I.D. SYMBOL
WALL TYPE SYMBOL
WALL TYPE NO.
1
ABC
AB
ADJ.
BD
BOT.
CLG.
℄
CLR.
CLO.
COL.
COMP.
CONC.
CONT.
C.J.
DTL.
DW
D
DBL.
DN
D.S.
E.O.S.
EQ.
EQUIV.
E.T.R.
EXT.
F.D.
F.F.
F.O.C.
F.O.E.W.
F.O.P.
F.O.S.
F.O.S.W.
GWB
AGGREGATE BASE COURSE
AIR BARRIER
ADJUSTABLE
BOARD
BOTTOM
CEILING
CENTERLINE
CLEAR
CLOSET
COLUMN
COMPOSITION
CONCRETE
CONTINUOUS
CONTROL JOINT
DETAIL
DISH WASHER
DRYER
DOUBLE
DOWN
DOWNSPOUT
EDGE OF SLAB
EQUAL
EQUIVALENT
EXISTING TO REMAIN
EXTERIOR
FLOOR DRAIN
FOIL FACED
FACE OF COLUMN
FACE OF EXISTING WALL
FACE OF POST
FACE OF STUD
FACE OF STEM WALL
GYPSUM WALL BOARD
HT.
INSTAL.
MANUF.
MTL.
MTR.
MIN.
N.T.S.
N.W.
O.C.
O.T.S.
P.T.
PWD
P.T.
R
REF.
REINF.
R.O.
SIM.
SQ. FT.
STL.
SSD
TEXT
T & G
T.O.
TYP.
U.N.O.
WC
WH
WR
WD
W
W/
HEIGHT
INSTALLATION
MANUFACTURER
METAL
MATERIAL
MINIMUM
NOT TO SCALE
NEW WORK
ON CENTER
OPEN TO STRUCTURE
PAINT
PLYWOOD
PRESSURE TREATED
RANGE
REFRIGERATOR
REINFORCED
ROUGH OPENING
SIMILAR
SQUARE FEET
STEEL
SEE STRUCTURAL DRAWINGS
TEXTURE
TONGUE & GROOVE
TOP OF
TYPICAL
UNLESS NOTED OTHERWISE
WATER CLOSET
WATER HEATER
WATER RESISTANT
WOOD
WASHER
WITH
1. THE CONTRACTOR IS RESPONSIBLE FOR FAMILIARIZING THEMSELF WITH THE CONTENT OF THESE
DRAWINGS PRIOR TO PROCEEDING WITH THE WORK.
2. THE CONTRACTOR SHALL REVIEW DESIGN INTENT AS SUBSTANTIATED IN THESE DOCUMENTS PRIOR
TO COMMENCING CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL ISSUE REQUEST FOR
INFORMATION (RFI'S) INQUIRIES TO THE OWNER AND THE ARCHITECT WHERE DESIGN INTENT IS NOT SELF
EVIDENT TO ELIMINATE DETRIMENTAL INTERPRETATIONS.
3. THE CONTRACTOR SHALL SUBMIT PRODUCT SUBMITTALS, MATERIAL AND SYSTEM SHOP DRAWINGS,
AND / OR SUBSTITUTION REQUESTS TO ADDRESS REQUIREMENTS AS SET FORTH BY PROJECT
SPECIFICATIONS AND AS REQUIRED TO DEMONSTRATE FULL UNDERSTANDING AND CONTROL OF
CONSTRUCTION MEANS AND METHODS. THE GENERAL CONTRACTOR SHALL PROCEED WITH
CONSTRUCTION ACTIVITIES AT THEIR OWN RISK PRIOR TO RECEIVING OWNER / ARCHITECT ASSOCIATED
APPROVALS.
4. IN THE EVENT THE CONTRACTOR, (INCLUDING SUB-TRADE AFFILIATES), DOES NOT FOLLOW RFI,
SUBMITTAL, SHOP DRAWING AND OR SUBSTITUTION PROTOCOL, COSTS AND BURDEN FOR CORRECTIVE
WORK SHALL BE SOLELY BORNE BY THE CONTRACTOR.
5. IN THE EVENT THE CONTRACTOR FINDS A CONFLICT OR DISCREPANCY WITH THESE DRAWINGS, THE
ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING. SHOULD THE CONTRACTOR PROCEED
WITHOUT NOTIFYING THE ARCHITECT OF SUCH CONFLICT, THE CONTRACTOR SHALL BE PROCEEDING AT
THEIR OWN RISK & ASSOCIATED LIABILITY.
6. THESE DRAWINGS SERVE TO REPRESENT DESIGN INTENT AS DIRECTED BY THE OWNER & COMPLIANT
WITH GOVERNING JURISDICTIONAL LAW. IN NO WAY SHALL THESE DRAWINGS SERVE TO DICTATE
METHODS OF CONSTRUCTION RELATIVE TO ADHERENCE TO EITHER. IT IS THE CONTRACTOR'S &
OWNER'S RESPONSIBILITY TO WORK WITHIN THE PARAMETERS OF THE AGENCY APPROVED DOCUMENTS
TO MAINTAIN THE INTEGRITY OF THE DESIGN INTENT AND AGENCY COMPLIANCE.
7. DEFERRED SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT OR ENGINEER, STAMPED TO INDICATE
THEY HAVE BEEN REVIEWED AND ARE IN GENERAL CONFORMANCE WITH THE BUILDING DESIGN, AND
SHALL BE SUBMITTED TO THE CITY BY THE ARCHITECT OR ENGINEER AS PER IBC SECTION 107.3.4.1 AND
THE CITY OF TACOMA REQUIREMENTS
ABBREVIATIONSGENERAL PROJECT NOTES
VICINITY MAPS
PROJECT TEAM PROJECT INFORMATION
LEGAL DESCRIPTION
THE NORTHWEST QUARTER OF THE SOUTHWEST QUARTER OF THE
SOUTHWEST QUARTER OF SECTION 20, [TOWNSHIP] 21 NORTH, RANGE 4
EAST, WILLIAMETTE MERIDIAN IN KING COUNTY, WASHINGTON; EXCEPT THE
NORTH 50 FEET THEROF; ALSO EXCEPT THE WEST 42 FEET THEROF
CONVEYED TO KING COUNTY FOR ROAD UNDER RECORDING NUMBERS
1229975 AND 8409280489.
CIVIL PLANS
C3.00 SITE PLAN
C4.00 GRADING AND DRAINAGE PLAN
C4.10 SITE SECTIONS
C5.00 FIRE TRUCK TURNING DIAGRAM
C5.01 SU-30 TURNING DIAGRAM
C5.02 GARBAGE TRUCK TURNING DIAGRAM
C5.03 PASSENGER CAR TURNING DIAGRAM
C5.04 WB-40 TURNING DIAGRAM
C6.00 WATER PLAN
C7.00 SEWER PLAN
LANDSCAPE PLANS
L1.00 TREE RETENTION PLAN
L1.21 IRRIGATION PLAN
L1.31 PLANTING PLAN
L1.32 PLANTING SCHEDULE
ELECTRICAL
SL1.0 LIGHTING NOTES, LUMINAIRE SCHEDULE & FIXTURE DETAILS
SL1.1 SITE PLAN - LIGHTING
INTERNATIONAL BUILDING CODE 2018 EDITION [IBC]
INTERNATIONAL MECHANICAL CODE 2018 EDITION [IMC]
INTERNATIONAL FIRE CODE 2018 EDITION [IFC]
NATIONAL ELECTRICAL CODE 2018 EDITION [NEC]
UNIFORM PLUMBING CODE 2018 EDITION [UPC]
WASHINGTON STATE ENERGY CODE 2018 EDITION [WSEC]
APPLICABLE CODES
DEFERRED SUBMITTALS
FIRE ALARM SYSTEM PLANS AND CALCULATIONS
FIRE SUPPRESSION PLANS & CALCULATIONS
TENANT IMPROVMENT PLANS FOR:
OTHER:
OTHER SPECIAL PROTECTION
PLUMBING PLANS
GREASE HOOD
BUILDING PROTECTION
ELECTRICAL PLANS
MECHANICAL PLANS & CALCULATIONS (INCLUDING ANY REQUIRED
FIRE/SMOKE DAMPERS)
CITY APPROVAL STAMP
FEDERAL WAY, WA
SURVEY
PRISM SURVEYING INC.
P.O. BOX 110700
TACOMA, WA 98411
GEOTECH
ZIPPER FEO ASSOCIATED, LLC
19023 36TH AVENUE W., SUITE D
LYNWOOD, WA 98036
T: (253) 212-2310
MECHANICAL / ELECTRICAL / PLUMBING
ROBISON ENGINEERING, INC.
AMANDA SMITH
19401 40TH AVENUE W., SUITE 302
LYNWOOD, WA 98036
T: (206)364.3343
E: ASMITH@ROBISONENGINEERING.COM
TRAFFIC ENGINEER
JAKE TRAFFIC
MARK JACOBS
P: (206)762.1978
E: JAKETRAFFIC@COMCAST.NET FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.
3110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1AG1.0
1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1AG1.1
UNIT TYPE BREAKDOWN
PODIUM UNITS 137
STUDIO 18
1-BEDROOM 102
2-BEDROOM 17
QUAD UNITS 12 UNITS X 8 BUILDINGS = 96 QUAD UNITS
1-BEDROOM 6 UNITS X 8 BUILDINGS = 48 1-BEDROOM UNITS AT QUADS
2-BEDROOM 6 UNITS X 8 BUILDINGS = 48 2-BEDROOM UNITS AT QUADS
18 TOTAL PODIUM STUDIO UNITS
102 PODIUM 1-BED + 48 QUAD 1-BED = 150 TOTAL 1-BEDROOM UNITS
17 PODIUM 2-BEDS + 48 QUAD 2-BEDS = 65 TOTAL 2-BEDROOM UNITS
PARKING CALCULATION PER UNIT TYPE (FWRC 19.220.050(6))
18 TOTAL STUDIO UNITS X 1.25 = 22.5 PARKING SPACES REQUIRED
150 TOTAL 1-BEDROOM UNITS X 1.5 = 225 PARKING SPACES REQUIRED
65 TOTAL 2-BEDROOM UNITS X 2.0 = 130 PARKING SPACES REQUIRED
22.5 + 225 + 130 = 377.5 OR 378 PARKING SPACES REQUIRED FOR RESIDENTIAL USE
PARKING CALCULATION PER COMMERCIAL USE (FWRC 19.220.010)
STAND ALONE COMMERCIAL BUILDING: 7,523 SF / 300 = 25.07 OR 26 STALLS
26 STALLS REQUIRED FOR STAND ALONE COMMERCIAL BUILDING
PARKING PROVIDED
253 AT GRADE STALLS PROVIDED
178 STRUCTURED STALLS PROVIDED
431 TOTAL PARKING STALLS PROVIDED
378 RESIDENTIAL USE + 26 STAND ALONE COMMERCIAL = 404 TOTAL STALLS REQUIRED
431 STALLS PROVIDED - 404 STALLS REQUIRED = 27 SURPLUS STALLS
TOTAL PARKING REQUIREMENT
RESIDENTIAL USE = 378 PARKING STALLS
COMMERCIAL USE = 26 PARKING STALLS
TOTAL PARKING STALL REQUIRED = 404 STALLS REQUIRED FOR RESIDENTIAL AND
COMMERCIAL USE
FWRC CODE COMPLIANCE INFORMATION
FWRC 19.220.050(5)
FOR 100 DWELLING UNITS OR MORE ON A SUBJECT PROPERTY, 25% OF PARKING SHALL
BE UNDERGROUND OR ON THE FIRST FLOOR WITHIN THE BUILDING FOOTPRINT, EXCEPT
FOR VISITOR PARKING WHICH CAN BE SURFACE PARKING.
431 STALLS PROVIDED X 25% = 107.75 OR 108 STALLS SHALL BE UNDERGROUND OR ON
THE FIRST FLOOR WITHIN THE BUILDING FOOTPRINT.
178 STALLS PROVIDED UNDERGROUND OR WITHIN THE BUILDING FOOTPRINT > 108
STALLS REQUIRED = COMPLY
FWRC.220.050(1)
ALL NONRESIDENTIAL GROUND FLOOR SPACES MUST HAVE A MINIMUM
FLOOR-TO-CEILING HEIGHT OF 13 FEET AND A MINIMUM DEPTH OF 15 FEET.
RESPONSE: SEE A1.30.
FWRC 19.125.070(3)
LANDSCAPE ISLANDS SHALL BE A MINIMUM SIZE OF 64 SQUARE FEET AND A
MAXIMUM OF 305 SQUARE FEET, AND A MINIMUM WIDTH OF SIX FEET AT THE
NARROWEST POINT FOR ISLANDS AT THE END OF 90-DEGREE PARKING ROWS,
THREE FEET AT THE END OF ROWS WITH ANGLES PARKING, AND EIGHT FEET IN
WIDTH FOR ISLANDS USED TO SEPARATE HEAD-TO-HEAD PARKING STALLS AND
SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS.
RESPONSE: SEE LANDSCAPE FOR CALCULATIONS.
(A) AT THE END OF ALL ROWS OF PARKING.
RESPONSE: PARKING ISLANDS ARE PROVIDED AT THE ENDS OF ALL ROWS OF
PARKING; SEE AS1.0
(B) FOR SEPARATION BUFFERING BETWEEN LOADING DOORS OR MANEUVERING
AREAS AND PARKING AREAS OR STALLS.
RESPONSE: LANDSCAPE SEPARATION BUFFERS ARE PROVIDED BETWEEN ANY
MANEUVERING AREAS, SEE AS1.0.
(C) ANY REMAINING REQUIRED LANDSCAPING SHALL BE DISPERSED THROUGHOUT
THE INTERIOR PARKING AREA IN A MANNER TO REDUCE VISUAL IMPACT OF THE
PARKING LOT.
RESPONSE: LANDSCAPING HAS BEEN DISPERSED THROUGHOUT THE INTERIOR
PARKING AREA TO REDUCE VISUAL IMPACT OF THE PARKING LOT; SEE AS1.0.
(D) DECIDUOUS TREES ARE PREFERRED FOR LANDSCAPE ISLANDS WITHIN INTERIOR
VEHICLE US AREA.
RESPONSE: SEE LANDSCAPE PLANTING PLAN FOR LANDSCAPE ISLAND TREE
SPECIES.
FWRC 19.115.050(3)(B)-(D)
(B) PARKING STRUCTURES WHICH ARE PART OF A NEW DEVELOPMENT SHALL BE
ARCHITECTURALLY CONSISTENT WITH EXTERIOR ARCHITECTURAL ELEMENTS OF
THE PRIMARY STRUCTURE, INCLUDING ROOFLINES, FACADE DESIGN, AND FINISH
MATERIALS.
RESPONSE: BRICK PILASTERS ARE USED TO CONNECT THE FACADE DESIGN BY
INCORPORATING A CONSISTENT LANGUAGE AND MATERIAL THAT IS BEING USED
AT THE PODIUM ENTRIES AND AMENITY AREAS. SEE A1.00-A1.04.
(C) PARKING STRUCTURES SHOULD INCORPORATE METHODS OF ARTICULATION
AND ACCESSORY ELEMENTS, PURSUANT TO FWRC 19.115.060(3)(B), ON FACADES
LOCATED ABOVE GROUND LEVEL.
RESPONSE: THE PARKING STRUCTURE INCORPORATES METAL SCREENS
COMPLIANT WITH 19.115.060(3)(B)(V) AND BRICK PILASTERS TO CONNECT THE
FACADE DESIGN.SEE A1.00-A1.04.
(D) BUILDINGS BUILT OVER PARKING SHOULD NOT APPEAR TO "FLOAT" OVER THE
PARKING AREA BUT SHOULD BE LINKED WITH GROUND LEVEL USES OR SCREENING.
PARKING AT GRADE UNDER A BUILDING IS DISCOURAGED UNLESS THE PARKING
AREA IS COMPLETELY ENCLOSED WITHIN THE BUILDING OR WHOLLY SCREENED
WITH WALLS AND/OR LANDSCAPE BERMS.
RESPONSE: THE PARKING AND AT GRADE RESIDENTIAL AMENITY HAS BEEN
DESIGNED TO GIVE THE PODIUM A BASE AS REQUIRED BY FWRC 19.115.090(Q). THE
PARKING IS BOTH COMPLETELY ENCLOSED WITHIN THE BUILDING AND IS
SCREENED WITH WALLS AND PERFORATED SCREENS TO PROVED VISUAL
INTEREST. BRICK PILASTERS ARE USED TO CONNECT THE FACADE DESIGN BY
INCORPORATING A CONSISTENT LANGUAGE AND MATERIAL THAT IS BEING USED
AT THE PODIUM ENTRIES AND AMENITY AREAS. SEE A1.00-A1.04.
FWRC 19.115.050(4)(A)-(B)
(A) PRIMARY ENTRANCES TO BUILDINGS, EXCEPT FOR ZERO LOT LINE TOWNHOUSE
DEVELOPMENT AND ATTACHED DWELLING UNITS ORIENTED AROUND AN INTERNAL
COURTYARD, SHOULD BE CLEARLY VISIBLE OR RECOGNIZABLE FROM THE
RIGHT-OF-WAY. PEDESTRIAN PATHWAYS FROM RIGHT-OF-WAY AND BUS STOPS TO
PRIMARY ENTRANCES, FROM PARKING LOTS TO PRIMARY ENTRANCES, AND
PEDESTRIAN AREAS, SHALL BE ACCESSIBLE AND SHOULD BE CLEARLY DELINEATED.
RESPONSE: A SITE WAYFINDING STRATEGY WILL INCORPORATE WAYFINDING
MONUMENT SIGNAGE TO CLEARLY LOCATE SITE ENTRIES, COMMERCIAL BUILDING
ENTRIES, RESIDENTIAL ENTRIES AND OUTDOOR RESIDENTIAL AMENITIES. SEE
AS1.1 FOR LOCATIONS.
(B) PEDESTRIAN PATHWAYS AND PEDESTRIAN AREAS SHOULD BE DELINEATED BY
SEPARATE PAVED ROUTES USING A VARIATION IN PAVED TEXTURE AND COLOR,
AND PROTECTED FROM ABUTTING VEHICLE CIRCULATION AREAS WITH
LANDSCAPING. APPROVED METHODS OF DELINEATION INCLUDE: STONE, BRICK OR
GRANITE PAVERS; EXPOSED AGGREGATE; OR STAMPED AND COLORED CONCRETE.
PAINT STRIPING ON ASPHALTS AS A METHOD OF DELINEATION IS NOT
ENCOURAGED.
RESPONSE: PEDESTRIAN PATHWAYS AND AREAS ARE DELINEATED USING
VARIATIONS OF PAVED MATERIAL AND COLOR. ALL CROSSWALKS HAVE BEEN
CHANGED TO REFLECT THIS REQUIREMENT. SEE AS1.0.
FWRC 19.115.050(4)(D)-(E)
(D) BICYCLE RACKS SHOULD BE PROVIDED FOR ALL COMMERCIAL DEVELOPMENTS.
RESPONSE: BICYCLE PARKING RACK HAVE BEEN ADDED NEAR THE COMMERCIAL
BUILDING. SEE AS1.1 FOR LOCATION.
(E) OUTDOOR FURNITURE, FIXTURES, AND STREETSCAPE ELEMENTS, SUCH AS
LIGHTING, FREESTANDING SIGNS, TRELLISES, ARBORS, RAISED PLANTERS,
BENCHES AND OTHER FORMS OF SEATING, TRASH RECEPTACLES, BUS STOPS,
PHONE BOOTHS, FENCING, ETC, SHOULD BE INCORPORATED INTO THE SITE DESIGN.
RESPONSE: OUTDOOR FURNITURE, SITE LIGHTING, BENCHES, BBQS, CHILDREN'S
PLAY EQUIPMENT AND WAYFINDING SIGNAGE IS PROPOSED FOR THE VARIOUS
PLAZAS AND RESIDENTIAL AMENITY AREAS. SEE AS1.0 AND AS1.1 FOR AMENITY
FEATURES. SEE SL1.1 FOR SITE LIGHTING LOCATIONS.
FWRC 19.115.060(2)
(2) EXCEPT FOR ZERO LOT LINE TOWNHOUSE DEVELOPMENT AND ATTACHED
DWELLING UNITS, ALL BUILDING FACADES THAT ARE BOTH LONGER THAN 60 FEET
AND ARE VISIBLE FROM EITHER A RIGHT-OF-WAY OR RESIDENTIAL USE OR ZONE
SHALL INCORPORATE FACADE TREATMENT ACCORDING TO THIS SECTION. SUBJECT
FACADES SHALL INCORPORATE AT LEAST TWO OF THE FOUR OPTIONS DESCRIBED
HEREIN; EXCEPT, HOWEVER, FACADES THAT ARE SOLIDLY SCREENED BY TYPE 1
LANDSCAPING, PURSUANT TO CHAPTER 19.125 FWRC, OUTDOORS, YARDS, AND
LANDSCAPING, MAY USE FACADE MODULATION AS THE SOLE OPTION UNDER THIS
SECTION. OPTIONS USED UNDER THIS SECTION SHALL BE INCORPORATED ALONG
THE ENTIRE LENGTH OF THE FACADE, IN ANY APPROVED COMBINATION. OPTIONS
USED MUST MEET THE DIMENSIONAL STANDARDS AS SPECIFIED HEREIN; EXCEPT,
HOWEVER, IF MORE THAN TWO ARE USED, DIMENSIONAL REQUIREMENTS FOR EACH
OPTION WILL BE DETERMINED ON A CASE-BY-CASE BASIS; PROVIDED, THAT THE
GROSS AREA OF A PEDESTRIAN PLAZA MAY NOT BE LESS THAN THE SPECIFIED
MINIMUM OF 200 SQUARE FEET.
(A) FACADE MODULATION. MINIMUM DEPTH: TWO FEET; MINIMUM WIDTH: 6 FEET,
MAXIMUM WIDTH: 60 FEET. ALTERNATIVE METHODS TO SHAPE THE BUILDING, SUCH
AS ANGLED OR CURVED FACADE ELEMENTS, OFF-SET PLANES, WING WALLS AND
TERRACING, WILL BE CONSIDERED; PROVIDED THAT THE INTENT OF THIS SECTION
IS MET.
(B) LANDSCAPE SCREENING. EIGHT-FOOT-WIDE TYPE II LANDSCAPE SCREENING
ALONG THE BASE OF THE FACADE, EXCEPT TYPE IV MAY BE USED IN PLACE OF TYPE
II FOR FACADES THAT ARE COMPRISED OF 50 PERCENT OR MORE WINDOW AREA
AND AROUND BUILDING ENTRANCES. FOR BUILDING FACADES THAT ARE LOCATED
ADJACENT TO A PROPERTY LINE, SOME OR ALL OF THE UNDERLYING BUFFER WIDTH
REQUIRED BY CHAPTER 19.25 FWRC, OUTDOORS, YARDS, AND LANDSCAPING, MAY
BE CONSIDERED IN MEETING THE LANDSCAPE WIDTH REQUIREMENT OF THIS
SECTION.
(C) CANOPY OR ARCADE. AS A MODULATION OPTION, CANOPIES OR ARCADES MAY
BE USED ONLY ALONG FACADES THAT ARE VISIBLE FROM THE RIGHT-OF-WAY.
MINIMUM LENGTH: 50 PERCENT OF THE LENGTH OF THE FACADE USING THIS
OPTION.
(D) PEDESTRIAN PLAZA: SIZE OF PLAZA: PLAZA SQUARE FOOTAGE IS EQUAL TO ONE
PERCENT OF THE GROSS FLOOR AREA OF THE BUILDING, BUT IT MUST BE A
MINIMUM OF 200 SQUARE FEET. THE PLAZA SHOULD BE CLEARLY VISIBLE AND
ACCESSIBLE FROM THE ADJACENT RIGHT-OF-WAY.
RESPONSE:
THE PODIUM BUILDING USES A COMBINATION OF ALL FOUR METHODS.
SEE DIAGRAM BELOW TO ILLUSTRATE COMPLIANCE. A DEPARTURE IS
REQUESTED FOR THE MOST FACING SOUTH FACADE DUE TO THE PARKING
GARAGE ENTRY AND GRADES AT THIS SIDE OF THE SITE. THERE WILL BE
LANDSCAPING AS REQUIRED FOR THE RETAINING WALLS IN THIS AREA.
THE COMMERCIAL BUILDING: NORTH FACADE USES FACADE MODULATION
TYPE II LANDSCAPE BUFFER. WEST FACADE USES FACADE MODULATION,
CANOPIES AND PEDESTRIAN PLAZA (1,658 SF). SOUTH FACADE USED FACADE
MODULATION, CANOPIES AND PEDESTRIAN PLAZA (1,658 SF). EAST FACADE
USES FACADE MODULATION AND A COMBINED LENGTH OF 19' OF
LANDSCAPE. SEE AS1.0, AS1.1, A3.00, A3.01 AND A3.10.
THE QUAD BUILDINGS ALL USE FACADE MODULATION AND ARE NOT VISIBLE
FROM THE ROW EXCEPT FOR QUAD 1. THE PROJECT IS REQUIRED TO HAVE
TYPE II OR III LANDSCAPE BUFFERS IN BETWEEN IT AND THE ROW. EACH
QUAD IS SURROUNDED BY A VARYING DEGREE OF LANDSCAPE SCREENING.
QUADS 2, 3, 4, 5, 6, 7 ARE ALL ADJACENT TO OR HAVE VIEWS OF PEDESTRIAN
PLAZAS OR RETENTION POND. DUE TO SITE CONSTRAINTS WE ASK FOR A
DEPARTURE FROM HAVING TO COMPLY FOR EACH QUAD AS WE HAVE
DESIGNED THEM TO HAVE A VILLAGE APPEAL. CANOPIES DO NOT FIT WITH
THE QUAD DESIGN AS THEIR STAIRWAYS ARE ALREADY COVERED FROM THE
ELEMENTS. HAVING TO ADD TYPE II LANDSCAPING AROUND EACH QUAD
FACADE IS NOT FEASIBLE DUE TO SITE CONSTRAINTS AND/OR COULD
BECOME A SAFETY CONCERN DUE TO AN INCREASE NUMBER OF HIDING
PLACES. IN ADDITION THE QUADS ARE BROKEN UP INTO TWO SIDES EACH
32'-6" WIDE WITH AN OPEN BREEZEWAY IN BETWEEN BREAKING UP EACH
SIDE TO LESS THAN 60' WIDE. SEE A2.10.
FWRC 19.115.080(3)
(3) COMMERCIAL AND RESIDENTIAL COMPONENTS MAY HAVE DIFFERENT
ARCHITECTURAL EXPRESSION, BUT THE FACADE SHALL EXHIBIT A NUMBER OF
UNIFYING ELEMENTS TO PRODUCE THE EFFECT OF AN INTEGRATED PROJECT.
RESPONSE: ALL BUILDINGS HAVE BEEN DESIGNED TO EXPRESS INDIVIDUALITY
WHILE MAINTAINING A UNIFIED CAMPUS DESIGN. THERE IS A SHARED MATERIAL
PALETTE USED ACROSS THE CAMPUS. A COMPLIMENTARY COLOR PALETTE HAS
BEEN SELECTED AND DISTRIBUTED ACROSS THE BUILDINGS. SHARED CANOPY
DESIGNS AND STOREFRONT WINDOW SYSTEMS ARE ALSO BEING USED FOR BOTH
THE PODIUM AND COMMERCIAL BUILDING. SEE A1.00-A1.05, A3.00 AND A3.01.
FWRC 19.115.090(1)(B)(D)
(B) ENTRANCE FACADES SHALL FACE FRONT ON, FACE, OR BE CLEARLY
RECOGNIZABLE FROM THE RIGHT-OF-WAY; AND SHALL INCORPORATE WINDOWS
AND OTHER METHODS OF ARTICULATION.
RESPONSE: THE COMMERCIAL BUILDING USES A VARIETY OF METHODS TO
CLEARLY DISTINGUISH THE ENTRIES SO THAT THEY ARE VISIBLE FROM THE
RIGHT-OF-WAY. STOREFRONT WINDOWS AND CANOPIES CLEARLY SHOW THE
BUILDINGS ENTRANCES. A PLAZA HAS ALSO BEEN LOCATED ADJACENT TO THESE
ENTRIES. THIS PUBLIC ACTIVATION ALONG WITH A WAYFINDING SITE DESIGN WILL
MAKE THE ENTRIES CLEARLY RECOGNIZABLE. SEE AS1.0 AND AS1.1.
(D) GROUND FLOOR ENTRANCES TO RETAIL SALES OR SERVICES SHALL
INCORPORATE PLAZA FEATURES OR FURNISHINGS, AND/OR STREETSCAPE
AMENITIES, IN CONTEXT-SENSITIVE AMOUNT AND COMBINATION, CONSIDERING THE
SCALE OF THE RETAIL USES(S) AND ENTRANCE(S) TO THE OVERALL BUILDING OR
DEVELOPMENT, AND THE PROXIMITY AND ACCESS TO OTHER EXISTING PLAZA OR
STREETSCAPE FEATURES.
RESPONSE: THE PLAZA AREAS PROVIDED FOR BOTH THE PODIUM AND
COMMERCIAL BUILDING ARE INCORPORATING PLAZA FEATURES INCLUDING, TABLE
AND CHAIRS, BENCHES, SITE LIGHTING, TRASH RECEPTACLES, PAVING
DIFFERENTIATION, WAY FINDING SIGNAGE IN AMOUNTS THAT ARE APPROPRIATE
FOR THE SIZED OF THE SPACES THEY SERVE. SEE AS1.0 AND AS1.1.
FWRC 19.115.090(P)
(P) BUILDING FACADES THAT EXCEED 120 FEET IN LENGTH AND ARE VISIBLE FROM
AN ADJACENT RESIDENTIAL ZONE, RIGHT-OF-WAY, PUBLIC PARK OR RECREATION
AREA SHALL INCORPORATE A SIGNIFICANT STRUCTURAL MODULATION (OFFSET).
THE MINIMUM DEPTH OF THE MODULAITON SHALL BE APPROXIMATELY EQUAL TO 10
PERCENT OF THE TOTAL LENGTH OF THE SUBJECT FACADE AND THE MINIMUM
WIDTH SHALL BE APPROXIMATELY TWICE THE MINIMUM DEPTH. THE MODULATION
SHALL BE INTEGRATED TO THE BUILDING STRUCTURE FROM BASE TO ROOFLINE.
RESPONSE:
348TH STREET FACADE (NORTH)
174' X 10% = 17.4' DEEP
17.4' X 2 = 34.8' WIDE
17.4' X 34.8' STUCTURAL OFFSET REQ'D
21'-10" X 26'-0" PROVIDED. DEPARTURE REQUESTED AS WIDTH DOES NOT COMPLY.
NORTHWEST CORNER
154' X 10% = 15.4' DEEP
15.4' X 2 = 30.8' WIDE
15.4' X 30.8' STUCTURAL OFFSET REQ'D
5340 SF OF BUILDING AREA REMOVED AND 5025 SF PROVIDED AS PUBLIC PLAZA
1ST AVENUE SOUTH (WEST)
197" X 10% = 19.7 DEEP
19.7' X 2 = 39.4' WIDE
19.7 X 39.4' STRUCTURAL OFFSET REQ'D
21'-10" X 36'-6" PROVIDED. DEPARTURE REQUESTED AS WIDTH DOESN'T COMPLY.
SEE STRUCTURAL OFFSET DIAGRAM BELOW. DUE TO SITE CONSTRAINTS A
DEPARTURE IS REQUESTED AS THE WIDTHS FOR THE STRUCTURAL OFFSETS DO
NOT FULLY COMPLY. THIS REQUIREMENT IS BELIEVED TO ASSIST IN REDUCING
MASS AND SCALE OF LONG BUILDINGS. WE HAVE TAKEN THIS INTO
CONSIDERATION AND HAVE REDUCED THE BUILDING INTO (3) MAIN SEGMENTS AS
WELL AS REMOVING MORE OF THE BUILDING FROM THE CORNER THAN IS
REQUIRED. THIS HAS ALLOWED THE DESIGN TO PROVIDE A RESIDENTIAL PLAZA
WHICH WILL ACTIVATE THE STREETSCAPE AND CORNER.
FWRC 19.115.090(Q)
(Q) BUILDINGS SHOULD BE DESIGNED TO HAVE A DISTINCT BASE, MIDDLE AND TOP.
THE BASE (TYPICALLY THE FIRST FLOOR) SHOULD CONTAIN THE GREATEST NUMBER
OF ARCHITECTURAL ELEMENTS SUCH AS WINDOW, MATERIALS, DETAILS,
OVERHANGS, CORNICE LINES, AND MOAONRY BELT COURSES. THE MIDSECTION, BY
COMPARISON, MAY BE SIMPLE. THE TOP SHULD AVOID THE APPEARANCE OF A FLAT
ROOF AND INCLUDE DISTINCTIVE ROOF SHAPES INCLUDING BUT NOT LIMITED TO
PITCHED, VAULTED OR TERRACED, ETC.
RESPONSE: ALL BUILDINGS HAVE BEEN DESIGNED TO HAVE A DISTINCT BASE
MIDDLE AND TOP. QUAD BUILDING 1, FACING 1ST AVENUE SOUTH, HAS BEEN
REVISED TO COMPLY WITH THIS CODE SECTION. WE HAVE ADDED A BRICK BASE
TO THE ENTRY SIDES OF THE FIRST FLOOR. SINCE QUADS 2-8 ARE NOT FACING ANY
RIGHT-OF-WAY WE WOULD LIKE TO DEPART FROM THIS REQUIREMENT FOR THESE
BUILDINGS. SEE A2.00, A2.01.
FWRC 19.115.090(R)
(R) RESIDENTIAL DESIGN FEATURES, INCLUDING BUT NOT LIMITED TO ENTRY
PORCHES, PROJECTING WINDOW BAYS, BALCONIES OR DECKS, INDIVIDUAL
WINDOWS (RATHER THAT STRIP WINDOWS),OFFSETS AND CASCADING OR STEPPED
ROOF FORMS, SHALL BE INCORPORATED INTO ALL BUILDINGS. WINDOW OPENINGS
SHALL HAVE VISIBLE TRIM MATERIAL OR PAINTED DETAILING THAT RESEMBLES
TRIM.
RESPONSE: THE DESIGN DOES NOT INCORPORATE WINDOW TRIM AS THIS
DETRACTS FROM THE MODERN AESTHETIC. WE REQUEST TO DEPART FROM THIS
REQUIREMENT FOR ALL BUILDINGS.
FWRC 19.220.050(11)
(11) THE SUBJECT PROPERTY MUST PROVIDE USABLE OPEN SPACE IN A TOTAL
AMOUNT EQUAL TO AT LEAST 150 SQ. FT. PER DWELLING UNIT, AND MAY INCLUDE
PRIVATE AREAS SUCH PLAYGROUNDS, RECREATION ROOMS, PLAZAS, ROOFTOP
TERRACES, POOLS, ACTIVE LOBBIES, ATRIUMS, OR OTHER AREAS THE DIRECTOR
DEEMS APPROPRIATE. A MINIMUM OF 25 PERCENT OF THE USABLE OPEN SPACE
PROVIDED MUST BE COMMON OPEN SPACE. PRIVATE OPEN SPACE SUCH AS A
PATIO, PORCH, BALCONY, OR YARD MAY BE CREDITED TOWARD TOTAL RESIDENTIAL
USABLE OPEN SPACE, IF SUCH PRIVATE OPEN SPACE IS A MINIMUM OF 48 SQUARE
FEET AND HAS A MINIMUM DIMENSION OF SIX FEET.
RESPONSE: QUAD BALCONIES ARE SHOWN ON SHEET A2.10.
FWRC 19.125.150(7)(b)
(7) SPACE AND ACCESS REQUIREMENTS. THE FOLLOWING MINIMUM SPACE AND
ACCESS REQUIREMENTS FOR SOLID WASTE AND RECYCLING STORAGE AREAS
SHALL BE INCORPORATED INTO THE DESIGN OF ALL BUILDINGS:
(B) MIXED-USE DEVELOPMENTS THAT CONTAINS BOTH RESIDENTIAL AND
NONRESIDENTIAL USES SHALL MEET THE STORAGE SPACE REQUIREMENTS SHOWN
IN TABLE A FOR RESIDENTIAL DEVELOPMENT, PLUS 50 PERCENT OF THE
REQUIREMENT FOR RESIDENTIAL AND NONRESIDENTIAL USES, AND DESIGNATED
STORAGE SPACE FOR RECYCLING SERVICES SHALL ALSO BE PROVIDED.
TABLE A: MORE THAN 100 DWELLING UNITS - 575 SF PLUS 4SF FOR EACH
ADDITIONAL UNIT ABOVE 100, EXCEPT AS PERMITTED IN SUBSECTION (7)(C) OF THIS
SECTION.
TABLE A: NONRESIDENTIAL DEVELOPMENT - 5,001-15,000SF - 125 SF
RESPONSE:
233 UNITS - 100 UNITS = 133 UNITS
100 UNITS: 575 SF
133 UNITS X 4SF = 532 SF
575 SF + 532 SF = 1,107 SF OF RESIDENTIAL SHARED STORAGE SPACE REQUIRED
FOR SOLID WASTE CONTAINERS
PODIUM SOLID WASTE AREA = 250 SF + 366 SF = 616 SF
QUAD SOLID WASTE AREA = 768 SF
616 SF + 768 SF = 1,384 SF OF RESIDENTIAL SOLID WASTE AREA > 1,107 SF =
COMPLY
STANDALONE COMMERCIAL = 7,523 SF = 125 SF OF SOLID WASTE AREA REQUIRED
FOR STANDALONE COMMERCIAL
STANDALONE SOLID WASTE AREA PROVIDED = 176 SF PROVIDED > 125 SF =
COMPLY
SEE A4.00, A4.01, AND A4.02.
106'-8"106'-10"7
9
'
-
2
"
173'-8"
NORTH FACADE
154'-1"NORTHWEST FACADE21'-10"36'-6"21'-10"27'
-0
"
26'-0"
FACADE MODULATION, TYPE II LANDSCAPE
FACADE MODULATION, PEDESTRIAN PLAZA (5025 SF),CANOPIESFACADE MODULATION AND TYPE II LANDSCAPEFACADE MODULATION & 20' WIDE LANDSCAPEFACADE MODULATION
REQUEST DEPARTURE FACADE MODULATION, 14' WIDE LANDSCAPEFACADE MODULATION, PEDESTRIAN PLAZA(1,152 SF)FACADE MODULATION,PEDESTRIAN PLAZA (2,172SF)FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.
3110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1AG1.1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1FWRC 19.110.010
(1) PURPOSE. TO PROVIDE AFFORDABLE HOUSING TO THE CITIZENS OF FEDERAL
WAY AND TO COMPLY WITH THE GROWTH MANAGEMENT ACT AND THE
COUNTY-WIDE PLANNING POLICIES FOR KING COUNTY.
(2) AFFORDABLE HOUSING DEFINED. “OWNER-OCCUPIED AFFORDABLE
HOUSING” MEANS DWELLING UNITS THAT ARE OFFERED FOR SALE AT A RATE THAT
IS AFFORDABLE TO THOSE INDIVIDUALS AND FAMILIES HAVING INCOMES THAT
ARE 80 PERCENT OR BELOW THE MEDIAN COUNTY INCOME. “RENTAL AFFORDABLE
HOUSING” MEANS DWELLING UNITS THAT ARE OFFERED FOR RENT AT A RATE THAT
IS AFFORDABLE TO THOSE INDIVIDUALS AND FAMILIES HAVING INCOMES THAT ARE
50 PERCENT OR BELOW THE MEDIAN COUNTY INCOME.
(3) MULTIPLE-FAMILY DEVELOPMENTS; SENIOR CITIZEN HOUSING; ASSISTED LIVING
FACILITIES; TOWNHOUSE DEVELOPMENT; ZERO-LOT LINE TOWNHOUSE
DEVELOPMENT; MIXED-USE PROJECTS; AND COTTAGE HOUSING IN MULTIFAMILY
ZONES. NEW PROJECTS INVOLVING 25 DWELLING UNITS OR MORE ARE REQUIRED
TO PROVIDE AFFORDABLE DWELLING UNITS AS PART OF THE PROJECT. AT LEAST
TWO DWELLING UNITS OR FIVE PERCENT OF THE TOTAL NUMBER OF PROPOSED
UNITS, WHICHEVER IS GREATER, SHALL BE AFFORDABLE. PROJECTS INCLUDING
AFFORDABLE DWELLING UNITS MAY EXCEED THE MAXIMUM ALLOWED NUMBER OF
DWELLING UNITS AS FOLLOWS:
(A) ONE BONUS MARKET RATE UNIT FOR EACH AFFORDABLE UNIT INCLUDED IN
THE PROJECT; UP TO 10 PERCENT ABOVE THE MAXIMUM NUMBER OF DWELLING
UNITS ALLOWED IN THE UNDERLYING ZONING DISTRICT.
(4) SINGLE-FAMILY DEVELOPMENTS. NEW SINGLE-FAMILY DEVELOPMENTS IN THE
RS-35, RS-15, RS-9.6, AND RS-7.2 ZONING DISTRICTS HAVE THE OPTION OF
PROVIDING AFFORDABLE DWELLING UNITS AS PART OF THE PROJECT. PROJECTS
INCLUDING AFFORDABLE DWELLING UNITS MAY REDUCE MINIMUM LOT SIZE AS
FOLLOWS:
(A) THOSE LOTS IN A NEW SINGLE-FAMILY CONVENTIONAL SUBDIVISION OR
SHORT SUBDIVISION WHICH ARE PROPOSED TO CONTAIN AFFORDABLE DWELLING
UNITS MAY BE REDUCED IN AREA BY UP TO 20 PERCENT OF THE MINIMUM LOT SIZE
OF THE UNDERLYING ZONING DISTRICT; PROVIDED, THAT THE OVERALL NUMBER OF
DWELLING UNITS IN THE SUBDIVISION MAY NOT EXCEED 10 PERCENT OF THE
MAXIMUM NUMBER OF UNITS ALLOWED IN THE UNDERLYING ZONING DISTRICT.
(5) PROVISIONS FOR AFFORDABLE HOUSING FOR COTTAGE HOUSING
DEVELOPMENT IN SINGLE-FAMILY RESIDENTIAL ZONES ARE SET FORTH IN
CHAPTER 19.250 FWRC.
(6) DURATION. AN AGREEMENT IN A FORM APPROVED BY THE CITY MUST BE
RECORDED WITH KING COUNTY DEPARTMENT OF ELECTIONS AND RECORDS
REQUIRING AFFORDABLE DWELLING UNITS WHICH ARE PROVIDED UNDER THE
PROVISIONS OF THIS SECTION TO REMAIN AS AFFORDABLE HOUSING FOR THE LIFE
OF THE PROJECT. THIS AGREEMENT SHALL BE A COVENANT RUNNING WITH THE
LAND, BINDING ON THE ASSIGNS, HEIRS AND SUCCESSORS OF THE APPLICANT.
RESPONSE:
DEVELOPMENT TOTAL NUMBER OF UNITS = 233 UNITS X 5% = 11.65 OR 12
AFFORDABLE DWELLING UNITS REQUIRED
12 UNITS WILL BE OFFERED FOR RENT AT A RATE THAT IS AFFORDABLE TO THOSE
INDIVIDUALS AND FAMILIES WITH INCOMES THAT ARE 50 PERCENT OR BELOW THE
MEDIAN COUNTY INCOME. THESE 12 UNITS WILL REMAIN AS AFFORDABLE HOUSING
FOR THE LIFE OF THE PROJECT.
FWRC CODE COMPLIANCE INFORMATION
FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.
3110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1AG1.1AG1.2
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1A4AS1.0
1
1
1
11
1
1
1 1
1
1
1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1PARKING GARAGE
MAIN ACCESS
PODIUM/COMMERCIAL
FF 248.00'RETAIL/COMMERCIAL
LEASING/AMENITY
PARKING GARAGE
DRIVE-
THRU35
17
54
19
38
18
4
MAIN ACCESS
QUADS
MAIN ACCESSPODIUM/COMMERCIALMAIN ACCESSQUADSTRASH/
RECYCLE
FF 248.00'
FF 248.00'
FF 248.00'8 - FF 244.00132'-6" FACADE "B.1"FACADE D 73'-5"148'-2" FACADE "C.1"297'-0" FACADE "C"274'-6" FACADE "B"
SOUTH 348TH STREET
PROPERTY LINE
PROPERTY LINEPROPERTY LINEPROPERTY LINE
5' TYPE III LANDSCAPE BUFFER PER FWRC 19.125.060 (a)5' TYPE III LANDSCAPE BUFFER PER FWRC 19.125.060 (c)15' TYPE I LANDSCAPE BUFFER PER FWRC 19.125.060 (b)5' TYPE III LANDSCAPE BUFFER PER FWRC 19.125.060 (c)5' TYPE III LANDSCAPE BUFFER PER FWRC 19.125.060 (a)7 - FF 243.006
-
F
F
2
4
3
.
0
0
3 - FF 240.001 - FF 234.00 P2ACCESSPLAZA02
04
05
25
TRASH
COMMERCIAL
142'-3"
FACADE "A"59'-6"63'-8"5
-
F
F
2
4
0
.
0
0
63'-8"1ST AVENUE SOUTHRETENTION POND
PLAZA
4 - FF 241.002 - FF 234.00
08
08
34
9
WETLAND
100'-0"
WETLAND
BUFFER
09
09ROW DEDICATIONGATE
GATE
GATE
PLAZA03
05
06
07 07
0707
07
07
0707
09
09
10
10
10
11
1111
11
11
11
11
11
11
1201
PROJECT DATA
SITE
GROSS LAND AREA:362,571 SF (8.3 ACRE)
CRITICAL AREA + BUFFER: (5,303 SF + 22,560 SF)27,864 SF
RIGHT-OF-WAY DEDICATION: 3,381 SF
PUBLIC PURPOSE:47,882 SF
NET LAND AREA:283,444 SF
PLAZA 1 (5,025 SF) - TABLES, CHAIRS, TRASH RECEPTACLES, PLANTERS, EXTERIOR SITE LIGHTING
PLAZA 2 (3,324 SF) - BENCHES, SITE LIGHTING, TRASH RECEPTACLES
PLAZA 3 (1,658 SF) - BICYCLE PARKING, TABLES, CHAIRS, TRASH RECEPTACLES, SITE LIGHTING, SIGNAGE
OPEN RECREATION AREA (1,956 SF) - PLANTING, BENCH, EXTERIOR BUILDING LIGHTING
COMMON RESIDENTIAL RECREATION AREA (4,812 SF) - BBQ AMENITY, PLANTING, COVERED ROOF AREA, SITE LIGHTING, TRASH RECEPTACLES, SIGNAGE
COMMON PEDESTRIAN PATH & OVERLOOK (2,912 SF) - BENCHES, PLANTINGS, SITE LIGHTING, TRASH RECEPTACLES, SIGNAGE
WALK-UP RESIDENTIAL ENTRY, TYP.
MID-RISE ENTRY
RETAINING WALLS - 6'-0" TALL WITH 5'-0" CLEAR BETWEEN RETAINING WALLS, TYP.
ACCESS GATES
WAYFINDING SITE SIGNAGE
COMMERCIAL BICYCLE PARKING
01
03
04
CRITICAL AREA:
WETLAND:5,304 SF
WETLAND BUFFER:22,560 SF
TOTAL CRITICAL AREA:27,864 SF
RIGHT-OF-WAY DEDICATION : 3,381
PUBLIC PURPOSE:
RETENTION POND:28,421 SF
OPEN SPACE (AREAS):4,812 SF
OPEN SPACE (PATH/OVERLOOK):2,912 SF
PUBLIC PLAZAS:11,737 SF
TOTAL PUBLIC PURPOSE:47,882 SF
KEY NOTES
02
FWRC 19.220.050(11) OPEN SPACE:
REQUIRED (150 SF X 233 UNITS):34,950 SF
34,950 SF X 25% = 8,737.5 SF OR 8,738 SF
COMMON OPEN SPACE REQUIRED:8,738 SF
OPEN SPACE PROVIDED:35,075 SF > 34,950 SF = COMPLY
COMMON OPEN SPACE PROVIDED: 19,461 SF > 8,738 SF = COMPLY
4,812 SF + 2,912 SF + 11,737 SF = 19,461 SF
AMENITY AREAS(PODIUM):9,614 SF
LEVEL 3: 4,019 SF
LEVEL 4: 2,310 SF
LEVEL 7: 3,285 SF
PRIVATE AREAS( DECKS, PATIOS) QUADS: 6,000 SF
48 DECKS X 55 SF = 2,640 SF
48 DECKS X 70 SF = 3,360 SF
COMMON AREAS(PLAYGROUND, BBQ AREA): 4,812 SF
COMMON PEDESTRIAN PATH & OVERLOOK: 2,912 SF
COMMON PUBLIC PLAZAS:11,737 SF
TOTAL OPEN SPACES:35,075 SF
05
06
07
08
09
10
11
12 FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.
3110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1AS1.1
PROJECT
NORTH
40'
SCALE: 1" = 40'-0"
20'0 120'80'
SCALE:
SITE PLAN: BUILDABLE LANDS DIAGRAM
1" = 40'-0"1
AS1.1
1
1
1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1132'-6" FACADE "B.1"FACADE D 73'-5"148'-2" FACADE "C.1"297'-0" FACADE "C"274'-6" FACADE "B"
142'-3"
FACADE "A"59'-6"63'-8"63'-8"
1.1
1.1
1.1
1.1
1.1
1.2
1.21.2
1.2
1.2
1.21.2
1.2
1.2
1.2
1.2
1.2
1.3
1.3
1.3
1.3
1.3 1.3
1.3
1.3
1.3
1.4
1.4
1.4
1.4
1.4
1.4
1.4 1.4
1.6
1.6
1.6
1.6
1.6
1.6
1.7
1.8
1.8
1.8
1.8
2.2
2.2
2.2 2.2
2.2
2.2
2.2 2.2
2.22.2
1.4
1.4 1.4
1.41.4
1.41.4
3.1
3.1
3.1
3.1
3.1
3.1
KEY NOTES
AVOID BLIND CORNERS IN PATHWAYS AND PARKING LOTS.
ALLOW NATURAL OBSERVATION FROM THE STREET TO THE USE, FROM THE USE TO THE STREET, AND BETWEEN USES.
PROVIDE NATURAL SURVEILLANCE FOR COMMON/OPEN SPACE AREAS.
PROVIDE ENTRIES THAT ARE CLEARLY VISIBLE
AVOID LANDSCAPING WHICH OBSTRUCTS NATURAL SURVEILLANCE AND ALLOWS INTRUDERS TO HIDE.
IN MIXED USE BUILDINGS INCREASE OPPORTUNITIES FOR NATURAL SURVEILLANCE, WHILE PROTECTING PRIVACY.
AVOID CONFUSION IN LOCATING BUILDING ENTRANCES.
AVOID PLACEMENT OF VEGETATION THAT WOULD ENABLE ACCESS TO A BUILDING OR TO NEIGHBORING BUILDINGS.
CREATE A "CARED FOR" IMAGE
1.1
1.2
1.3
1.6
2.2
2.4
3.1
1.4
1.8
FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.
3110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1AS1.2
PROJECT
NORTH
40'
SCALE: 1" = 40'-0"
20'0 120'80'
SCALE:
SITE PLAN: CPTED
1" = 40'-0"1
AS1.2
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1EXTERIOR ELEVATION SHEET NOTES
1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL
OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN
PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTORS RESPONSIBILITY TO
COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED.
2. SEE ROOF PLAN SHEETS A180-A183 FOR DOWNSPOUT LOCATIONS
3. REFER TO SHEET A650 FOR MATERIAL CALLOUT INFORMATION.
4. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/
COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD
COLOR CHART.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR
SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS.
6. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR
SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS.
7. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE-
APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2018 WASHINGTON
STATE ENERGY CODE.
8. TOPOGRAPHY SHOWN AS REFERENCE. SEE CIVIL DRAWINGS.
EXTERIOR ELEVATION LEGEND
KEYNOTE TAGS
WINDOWS
DOORS
BALCONY (SEE A630 FOR
DETAILS)
ESXX MATERIAL TAGS
INTAKE VENT
EXHAUST VENT
XX-XX
(SEE SHEET A650 FOR MATERIAL
INFORMATION)
(SEE SHEET A610 FOR DIFFERENT TYPES)
(SEE SHEET A600 FOR DIFFERENT TYPES)
(WITH 3'-0" CIRCLE AWAY FROM
OPENINGS, PER IBC)
T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 3 PLAN (ENTRY)0' -0"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"
W ZUX
12' - 4"8' - 11 1/4"9' - 10 3/4"9' - 10 3/4"9' - 11 1/2"15' - 0"TYPE VA
CONSTRUCTION
TYPE IA
CONSTRUCTION
V Y
LEVEL 7.1 PLAN45' -1 1/2"
MAX HEIGHT66' -0 1/4"66' - 0 1/4"0' - 4 1/2"T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 3 PLAN (ENTRY)0' -0"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"
AVERAGE GRADE PLANE245' -6"
WZ UX
12' - 4"8' - 11 1/4"9' - 10 3/4"9' - 10 3/4"9' - 11 1/2"15' - 0"TYPE VA
CONSTRUCTION
TYPE IA
CONSTRUCTION 66' - 0 1/4"VY
LEVEL 7.1 PLAN45' -1 1/2"
MAX HEIGHT66' -0 1/4"0' - 4 1/2"62' - 11 1/4"APPROXIMATE FOOTPRINT
1" = 80' - 0"
KEY PLAN
2
1
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N S TR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\tgraff\Documents\2002_Federal Way - Podium_Tyler_Graff_JGA.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII ELEVATIONS - 07/19/2021
EXTERIOR ELEVATIONS
2002
A200
BC
1/8" = 1'-0"
SOUTHEAST ELEVATION2
1/8" = 1'-0"
NORTHWEST ELEVATION1
Key Value Keynote Text
0'4'8'16'32'
SCALE : 1/8" = 1' -0"
EXTERIOR ELEVATION SHEET NOTES
#DESCRIPTIONMM/DD/YYYYA1.00
MECHANICAL
SCREEN
(2) ADDITIONAL LEVELS OF
BELOW GRADE PARKING
(2) ADDITIONAL LEVELS OF
BELOW GRADE PARKING
BELOW GRADE PARKING BEYOND
1
1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1A1.01
(2) ADDITIONAL LEVELS OF
BELOW GRADE PARKING
(2) ADDITIONAL LEVELS OF
BELOW GRADE PARKING
BELOW GRADE PARKING BEYOND
BELOW GRADE PARKING BEYOND
1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1A1.02
(2) ADDITIONAL LEVELS OF
BELOW GRADE PARKING
BELOW GRADE PARKING BEYOND
(2) ADDITIONAL LEVELS OF
BELOW GRADE PARKING
1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1A1.03
NO ADDITIONAL LEVELS OF
BELOW GRADE PARKING
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1A1.04
BELOW GRADE PARKING BEYOND
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 3 PLAN (ENTRY)0' -0"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"
AVERAGE GRADE PLANE245' -6"
A B
TYPE VA
CONSTRUCTION
TYPE IA
CONSTRUCTION
MAX HEIGHT66' -0 1/4"12' - 4"8' - 11 1/4"9' - 10 3/4"9' - 10 3/4"9' - 11 1/2"15' - 0"T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 3 PLAN (ENTRY)0' -0"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"
AVERAGE GRADE PLANE245' -6"
AB
TYPE VA
CONSTRUCTION
TYPE IA
CONSTRUCTION
MAX HEIGHT66' -0 1/4"15' - 0"9' - 11 1/2"9' - 10 3/4"9' - 10 3/4" 8' - 11 1/4"12' - 4"T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"
21
TYPE VA
CONSTRUCTION
TYPE IA
CONSTRUCTION
MAX HEIGHT66' -0 1/4"
T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"
2 1
4A304
TYPE VA
CONSTRUCTION
TYPE IA
CONSTRUCTION
MAX HEIGHT66' -0 1/4"12' - 4"8' - 11 1/4"9' - 10 3/4"9' - 10 3/4"9' - 11 1/2"APPROXIMATE FOOTPRINT
1" = 80' - 0"
KEY PLAN
1
3
2
4
EXTERIOR ELEVATION SHEET NOTES
1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL
OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN
PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTORS RESPONSIBILITY TO
COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED.
2. SEE ROOF PLAN SHEETS A180-A183 FOR DOWNSPOUT LOCATIONS
3. REFER TO SHEET A650 FOR MATERIAL CALLOUT INFORMATION.
4. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/
COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD
COLOR CHART.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR
SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS.
6. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR
SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS.
7. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE-
APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2018 WASHINGTON
STATE ENERGY CODE.
8. TOPOGRAPHY SHOWN AS REFERENCE. SEE CIVIL DRAWINGS.
EXTERIOR ELEVATION LEGEND
KEYNOTE TAGS
WINDOWS
DOORS
BALCONY (SEE A630 FOR
DETAILS)
ESXX MATERIAL TAGS
INTAKE VENT
EXHAUST VENT
XX-XX
(SEE SHEET A650 FOR MATERIAL
INFORMATION)
(SEE SHEET A610 FOR DIFFERENT TYPES)
(SEE SHEET A600 FOR DIFFERENT TYPES)
(WITH 3'-0" CIRCLE AWAY FROM
OPENINGS, PER IBC)
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\tgraff\Documents\2002_Federal Way - Podium_Tyler_Graff_JGA.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII ELEVATIONS - 07/19/2021
EXTERIOR ELEVATIONS
2002
A205
BC
1/8" = 1'-0"
ELEVATION - WEST SLOT - NORTH1 1/8" = 1'-0"
ELEVATION - WEST SLOT - SOUTH2 1/8" = 1'-0"
ELEVATION - NORTH SLOT - EAST41/8" = 1'-0"
ELEVATION - NORTH SLOT - WEST3
Key Value Keynote Text
EXTERIOR ELEVATION SHEET NOTES #DESCRIPTIONMM/DD/YYYYA1.05
(2) ADDITIONAL LEVELS OF BELOW GRADE PARKING
BELOW GRADE
PARKING BEYOND
BELOW GRADE
PARKING BEYOND
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #144
M
M
33
22
11
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
J
J
K
K
L
L
55
66
77
88
99
1010
1111
1313
W
W
Z
Z
U
U
31
31
34
34
32
32
33
33
1212
X
X
V
V
Y
Y
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N STR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Podium_epuryear7.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII IMAGES - 07/15/2021
LEVEL 6 - PODIUM
2002
UPIII-06
BC
1/16" = 1'-0"
LEVEL 61 #DESCRIPTIONMM/DD/YYYY23'-0"21'-3"23'-7"22'-5"14'-1"21'-10"25'-8"29'-4"7'-10"6'-8"25'-3"13'-3"28'-3"20'-8"28'-4"13'-3"25'-4"6'-7"7'-10"18'-9"21'-10"36'-2"14'-1"10'-1"46'-9"11'-9"44'-9"25'-6"10'-3"36'-3"44'-9"22'-6"36'-0"20'-7"13'-0"27'-8"5'-5"13'-0"9'-9"13'-6"20'-1"13'-6"9'-9"12'-11"5'-9"27'-9"12'-11"22'-4"34'-1"8'-10"35'-6"36'-3"10'-3"25'-6"2'-0"2'-0"8'-4"13'-6"0'-11"
2'-0"
2'-0"
5'-0"
2'-0"
2'-0"
8'-4"13'-6"
0'-11"
2'-0"
2'-0"
2'-0"
4'-0"
2'-0"
4'-0"
2'-0"
4'-3"
2'-4"
4'-1"2'-0"4'-0"
2'-0"
A1.10
ELEVATORS
REFUSE
CHUTE
PLAN, TYP.
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #144
33
22
11
A
A
B
B
C
C
D
D
E
E
F
F
G
G
55
66
77
W
W
Z
Z
U
U
31
31
34
34
32
32
33
33
X
X
V
V
Y
Y
63' - 8"
17' - 10"28' - 0"17' - 10"10' - 8"17' - 4"13' - 0 1/2"150' - 9 1/2"22' - 11 1/8"5 6 ' - 0 1 /2 "2
7
'
-
2
1
/
4
"21' - 2"3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N STR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Podium_epuryear7.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII IMAGES - 07/15/2021
LOBBY + ADJACENT AMENITY
2002
UPIII-10
BC#DESCRIPTIONMM/DD/YYYY1/8" = 1'-0"
LEVEL 3 AMENITY1
27'
-
1
0
"
A1.20
RETAIL
MAIL
RESTROOM
RESTROOM
ELEVATORS
LEASING
MANAGER’S
OFFICE
VESTIBULE
VESTIBULE
LOBBY
FITNESS
CENTER
RESTROOM
BICYCLE
STORAGE
RESTROOM
VESTIBULE
VESTIBULE
PACKAGE
ROOM
COPY
STORAGE
LEASING
LEASING
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1DN8' - 9"8' - 9 1/2"8' - 6"5' - 6"34' - 6"13' - 6 1/2"2' - 0" 3' - 7 3/4"
2' - 0"25' - 7 1/2"
21' - 9"5' - 2"3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N STR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Podium_epuryear7.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII IMAGES - 07/15/2021
AMENITY SPACES
2002
UPIII-11
BC#DESCRIPTIONMM/DD/YYYY1/4" = 1'-0"
LEVEL 4 AMENITY1 1/4" = 1'-0"
LEVEL 7 AMENITY2 A1.21
AMENITY
EXTERIOR
AMENITY
EXTERIOR
AMENITY
AMENITY
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1LEVEL 1 PLAN228' -0"
T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 2 PLAN-10' -0"
LEVEL 3 PLAN (ENTRY)0' -0"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"
AVERAGE GRADE PLANE245' -6"12' - 4"8' - 11 1/4"9' - 10 3/4"9' - 10 3/4"9' - 11 1/2"15' - 0"69' - 6 1/4"
T.O ROOF
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BATH
BATH
BATH
BATH
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
BATH
BATH
BATH
BATH
BEDROOM
BEDROOM
BEDROOM
BEDROOM
LOBBY
71' - 10 3/4"
LEVEL 7.1 PLAN45' -1 1/2"
MAX HEIGHT66' -0 1/4"13' - 0"14' - 0"LEVEL 1 PLAN228' -0"
T.O. PLATE53' -8 1/4"
HEIGHT OF STR. PER FWMC60' -5 1/4"
LEVEL 2 PLAN-10' -0"
LEVEL 3 PLAN (ENTRY)0' -0"
LEVEL 4 PLAN15' -0"
LEVEL 5 PLAN24' -11 1/2"
LEVEL 6 PLAN34' -10 1/4"
LEVEL 7 PLAN44' -9"6' - 9"8' - 11 1/4"9' - 10 3/4"9' - 10 3/4"9' - 11 1/2"15' - 0"3' - 1"T.O PARAPET
LOBBY
LIVING
LIVING
LIVING
LIVING
62' - 8 1/4"
LEVEL 7.1 PLAN45' -1 1/2"
MAX HEIGHT66' -0 1/4"14' - 0"13' - 0"SECTION GENERAL NOTES
1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL
OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN
PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTORS RESPONSIBILITY TO
COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED.
2. FOR INFORMATION REGARDING THE MAXIMUM BUILDING HEIGHT DATUM, AS APPLICABLE, REFER TO
THE LONGITUDINAL BUILDING SECTIONS TAKEN FROM THE EAST TO THE WEST. THESE SECTIONS
BEST ILLUSTRATE THE PLANE THAT ESTABLISHES THE MAXIMUM HEIGHT DATUM.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR
SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS.
4. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR
SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS.
5. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE-
APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2018 WASHINGTON
STATE ENERGY CODE.
6. SEE ROOF PLAN SHEETS FOR DOWNSPOUT LOCATIONS.
SECTION LEGEND
HORIZONTAL ASSEMBLIES (ROOF AND FLOOR) AND HORIZONTAL ASSEMBLY
TAGS
MAJOR APPLIANCES AND TAGS
MAJOR PLUMBING FIXTURES
APPROXIMATE FOOTPRINT
1" = 80' - 0"
KEY PLAN 12
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\tgraff\Documents\2002_Federal Way - Podium_Tyler_Graff_JGA.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII ELEVATIONS - 07/19/2021
BUILDING SECTIONS
2002
A306
BC
1/8" = 1'-0"
CENTER OF BUILDING1 1/8" = 1'-0"
MAIN ENTRY CANOPY TO PARAPET2
SECTION SHEET NOTES
Key Value Keynote Text #DESCRIPTIONMM/DD/YYYY0'4'8'16'32'
SCALE : 1/8" = 1' -0"
A1.30
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1A1.40
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N STR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\Aroberts\Documents\2002_Federal Way - Podium_arobertsUZ39T.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII ELEVATIONS - 07/19/2021
EXTERIOR RENDERS
2002
A900
BC
EXTERIOR PERSPECTIVE - EAST FACADE FACING NORTHWEST1 EXTERIOR PERSPECTIVE - EAST FACADE FACING SOUTHWEST2
EXTERIOR PERSPECTIVE - NORTH FACADE FACING SOUTH3 EXTERIOR PERSPECTIVE - NORTHWEST FACADE FACING
SOUTHEAST4 #DESCRIPTIONMM/DD/YYYY1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #11ST FLOOR PLAN0' -0"
BASE OF UPPER ROOF31' -0"
2ND FLOOR PLAN9' -11 1/2"
3RD FLOOR PLAN19' -10 1/4"9' - 11 1/2"9' - 10 3/4"11' - 1 3/4"ABCGHEF
MAX HEIGHT OF BUILDING37' -8"
D
37' - 8"T.O. PLATE28' -9 1/2"8' - 11 1/4"1ST FLOOR PLAN0' -0"
BASE OF UPPER ROOF31' -0"
2ND FLOOR PLAN9' -11 1/2"
3RD FLOOR PLAN19' -10 1/4"
12345867
MAX HEIGHT OF BUILDING37' -8"11' - 1 3/4"9' - 10 3/4"9' - 11 1/2"T.O. PLATE28' -9 1/2"
OPEN
OPEN
ELEVATION SHEET NOTES
1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL
OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN
PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
COORDINATE THE ARCHITECT'S DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED.
2. SEE ROOF PLAN SHEET A120 FOR DOWNSPOUT LOCATIONS
3. REFER TO MATERIALS SCHEDULE ON SHEET A650 FOR CALLOUT INFORMATION.
4. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/
COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD
COLOR CHART.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR
SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS.
6. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR
SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS.
7. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE-
APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2018 WASHINGTON
STATE ENERGY CODE.
8. FOR BREEZEWAY MATERIALS REFER TO SHEET A450
ELEVATION LEGEND
KEYNOTE TAGS
WINDOWS (SEE A610 FOR DIFFERING STYLES)
DOORS (SEE A600 FOR DIFFERING STYLES)
ESXX
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N S TR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\tgraff\Documents\2002_Federal Way - Quads_Tyler_Graff_JGA.rvtFEDERAL WAY MIXED USE (QUADS) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TG1st Pricing Set - 07/01/2021
EXTERIOR ELEVATIONS
2002
A200
BC
3/16" = 1'-0"
NORTH ELEVATION1
3/16" = 1'-0"
EAST ELEVATION2 0'0'2'4'8'16'
SCALE : 3/16" = 1' -0"#DESCRIPTIONMM/DD/YYYYA2.00
NOTE:
BRICK ONLY APPLIED TO QUAD 1. QUADS 2-8 WILL
HAVE THE HORIZONTAL LAP SIDING CONTINUE TO
THE BASE.
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #11ST FLOOR PLAN0' -0"
BASE OF UPPER ROOF31' -0"
2ND FLOOR PLAN9' -11 1/2"
3RD FLOOR PLAN19' -10 1/4"9' - 10 3/4"9' - 11 1/2"A B C G HEF
MAX HEIGHT OF BUILDING37' -8"11' - 1 3/4"D
T.O. PLATE28' -9 1/2"
1ST FLOOR PLAN0' -0"
BASE OF UPPER ROOF31' -0"
2ND FLOOR PLAN9' -11 1/2"
3RD FLOOR PLAN19' -10 1/4"11' - 1 3/4"9' - 10 3/4"9' - 11 1/2"1 2 3 4 5 867
MAX HEIGHT OF BUILDING37' -8"
T.O. PLATE28' -9 1/2"
OPEN
OPEN
ELEVATION SHEET NOTES
1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL
OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN
PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
COORDINATE THE ARCHITECT'S DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED.
2. SEE ROOF PLAN SHEET A120 FOR DOWNSPOUT LOCATIONS
3. REFER TO MATERIALS SCHEDULE ON SHEET A650 FOR CALLOUT INFORMATION.
4. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/
COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD
COLOR CHART.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR
SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS.
6. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR
SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS.
7. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE-
APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2018 WASHINGTON
STATE ENERGY CODE.
8. FOR BREEZEWAY MATERIALS REFER TO SHEET A450
ELEVATION LEGEND
KEYNOTE TAGS
WINDOWS (SEE A610 FOR DIFFERING STYLES)
DOORS (SEE A600 FOR DIFFERING STYLES)
ESXX
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N S TR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\tgraff\Documents\2002_Federal Way - Quads_Tyler_Graff_JGA.rvtFEDERAL WAY MIXED USE (QUADS) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TG1st Pricing Set - 07/01/2021
EXTERIOR ELEVATIONS
2002
A201
BC
3/16" = 1'-0"
SOUTH ELEVATION1
3/16" = 1'-0"
WEST ELEVATION2
0'0'2'4'8'16'
SCALE : 3/16" = 1' -0"#DESCRIPTIONMM/DD/YYYYA2.01
NOTE:
BRICK ONLY APPLIED TO QUAD 1. QUADS 2-8 WILL
HAVE THE HORIZONTAL LAP SIDING CONTINUE TO
THE BASE.
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1A2.10
1. ALL EXTERIOR WALL DIMENSIONS ARE TO FACE OF STUD, UNLESS NOTED OTHERWISE AS A CLEAR
DIMENSION
2. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION.
CONFLICTS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE START OF
CONSTRUCTION.
3. SEE STRUCTURAL DRAWINGS FOR PRIMARY STRUCTURAL CONCRETE WORK, INCLUDING COLUMNS, SHEAR
WALLS, THICKENED SLABS, ETC. NOT DESCRIBED HEREIN.
4. SEE CIVIL DRAWINGS FOR GRADING AND UTILITY INFORMATION
5. SEE ENLARGED UNIT PLANS FOR INTERIOR DIMENSIONS AND INFORMATION
6. NOT ALL KEYNOTES ON EACH SHEET.
7. DO NOT MEASURE DRAWINGS TO DETERMINE OMITTED DIMENSIONS. CONTACT ARCHITECT.
8. DOORS NOT LOCATED BY DIMENSIONS ON PLANS OR DETAILS SHALL BE 4" & 4 1/2" (METAL WALLS & WOOD
WALLS, RESPECTIVELY) FROM EDGE OF DOOR OPENING TO FINISH FACE OF ADJACENT WALL.
9. PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE STOPPED.
10. ALL CONCRETE VISIBLE FROM PUBLICLY ACCESSIBLE SPACES TO ARCHITECTURALLY EXPOSED CONCRETE.
11. FOR FIRE EXTINGUISHER CABINETS, SEE AL101-AL103
FLOOR PLAN GENERAL NOTES
11
A
A
22
33
44
55
8 8
6 6
7 7
B
B
C
C
G
G
H
H
E
E
F
F
D
D
F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.C.O.P.W.F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.
F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.F.O.S.W.C.O.P.W.61' - 0"73' - 2"4' - 6"4' - 6"73' - 2"4' - 6"4' - 6"61' - 0"
11' - 9"10' - 6"11' - 6"13' - 2"11' - 1"
11' - 9"10' - 6"11' - 6"13' - 2"11' - 1"5' - 6"5' - 6"5' - 6"5' - 6"W00
FLOOR PLAN LEGEND
NOTES
SEE G.
DOOR AND DOOR TAGS (FOR CLEARANCES SEE FLOOR PLAN GENERAL NOTES,
FOR ADA APPROACH SEE AG100 SERIES)
WALLS AND WALL TAGS
WINDOW AND WINDOW TAGS
MAJOR APPLIANCES
MAJOR PLUMBING FIXTURES
HOSE BIBB
WXX
HB
XXX
FLOOR PLAN SHEET NOTES
3/16" = 1'-0"
1ST FLOOR PLAN1
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N STR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE
WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Quads_epuryear7.rvtFEDERAL WAY MIXED USE (QUADS) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TG1st Pricing Set - 07/01/2021
1ST FLOOR PLAN
2002
A101
BC
Key Value Keynote Text
0'0'2'4'8'16'
SCALE : 3/16" = 1' -0"#DESCRIPTIONMM/DD/YYYY2'-0"32'-6"24'-6"32'-6"DECK
DECK
DECK
DECK
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #11ST FLOOR PLAN248' -0"
ABCDEFHG
T.O. PLATE262' -0"
UPPER ROOF HEEL HT.268' -10"T.O. PARAPET22' - 6"3' - 11 1/2"
T.O. ROOF276' -7 1/2"14' - 0"6' - 10"7' - 9 1/2"1ST FLOOR PLAN248' -0"
12356
T.O. PLATE262' -0"
UPPER ROOF HEEL HT.268' -10"
4 3.6
T.O. ROOF276' -7 1/2"6' - 10"14' - 0"ELEVATION SHEET NOTES
1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL
OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN
PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOS RESPONSIBILITY TO
COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED.
2. SEE ROOF PLAN SHEET A120 FOR DOWNSPOUT LOCATIONS
3. REFER TO ELEVATION KEYNOTES ON THIS SHEET FOR CALLOUT INFORMATION.
4. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/
COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD
COLOR CHART.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR
SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS.
6. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR
SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS.
7. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE-
APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2018 WASHINGTON
STATE ENERGY CODE.
ELEVATION LEGEND
KEYNOTE TAGS
WINDOW
DOORS (SEE A600 FOR DIFFERING STYLES)
MATERIAL TAGS
ESXX
ESXX
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2019
BY GRAVES +ASSOCIATES
PROJECT NUMBER:
PM:DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES +ASSOCIATES AND ARE NOT TO BE USED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE
WRITTEN AUTHORIZATION OF GRAVES +ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Retail_epuryear7.rvtFEDERAL WAY MIXED USE(RETAIL)X MARKS THE SPOT, LLC1ST AVE S. &S. 348TH STFEDERAL WAY, WA 98003TG1ST PRICING SET - 07/01/2021
EXTERIOR ELEVATIONS
2002
A200
BC
3/16" = 1'-0"
NORTH ELEVATION1
3/16" = 1'-0"
EAST ELEVATION2
EXTERIOR ELEVATION SHEET NOTES
Key Value Keynote Text #DESCRIPTION//YRMODY0'0'2'4'8'16'
SCALE : 3/16" = 1' -0"A3.00
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #11ST FLOOR PLAN248' -0"
A B C D E F HG
T.O. PLATE262' -0"
UPPER ROOF HEEL HT.268' -10"7' - 9 1/2" +/-6' - 10"14' - 0"T.O. ROOF276' -7 1/2"10' - 8"1ST FLOOR PLAN248' -0"
1 2 3 5 6
T.O. PLATE262' -0"
UPPER ROOF HEEL HT.268' -10"
43.6
7' - 9 1/2" +/-6' - 10"14' - 0"T.O. ROOF276' -7 1/2"11' - 4"ELEVATION SHEET NOTES
1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL
OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN
PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOS RESPONSIBILITY TO
COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED.
2. SEE ROOF PLAN SHEET A120 FOR DOWNSPOUT LOCATIONS
3. REFER TO ELEVATION KEYNOTES ON THIS SHEET FOR CALLOUT INFORMATION.
4. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/
COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD
COLOR CHART.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR
SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS.
6. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR
SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS.
7. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE-
APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2018 WASHINGTON
STATE ENERGY CODE.
ELEVATION LEGEND
KEYNOTE TAGS
WINDOW
DOORS (SEE A600 FOR DIFFERING STYLES)
MATERIAL TAGS
ESXX
ESXX
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2019
BY GRAVES +ASSOCIATES
PROJECT NUMBER:
PM:DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES +ASSOCIATES AND ARE NOT TO BE USED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE
WRITTEN AUTHORIZATION OF GRAVES +ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Retail_epuryear7.rvtFEDERAL WAY MIXED USE(RETAIL)X MARKS THE SPOT, LLC1ST AVE S. &S. 348TH STFEDERAL WAY, WA 98003TG1ST PRICING SET - 07/01/2021
EXTERIOR ELEVATIONS
2002
A201
BC
3/16" = 1'-0"
SOUTH ELEVATION1
3/16" = 1'-0"
WEST ELEVATION2
Key Value Keynote Text
EXTERIOR ELEVATION SHEET NOTES
0'0'2'4'8'16'
SCALE : 3/16" = 1' -0"#DESCRIPTION//YRMODYA3.01
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #11. ALL EXTERIOR WALL DIMENSIONS ARE TO FACE OF STUD, UNLESS NOTED OTHERWISE AS A CLEAR
DIMENSION
2. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION.
CONFLICTS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE START OF
CONSTRUCTION.
3. SEE STRUCTURAL DRAWINGS FOR PRIMARY STRUCTURAL CONCRETE WORK, INCLUDING COLUMNS, SHEAR
WALLS, THICKENED SLABS, ETC. NOT DESCRIBED HEREIN.
4. SEE CIVIL DRAWINGS FOR GRADING AND UTILITY INFORMATION
5. NOT ALL KEYNOTES ON EACH SHEET.
6. DO NOT MEASURE DRAWINGS TO DETERMINE OMITTED DIMENSIONS. CONTACT ARCHITECT.
7. DOORS NOT LOCATED BY DIMENSIONS ON PLANS OR DETAILS SHALL BE 4" & 4 1/2" (METAL WALLS & WOOD
WALLS, RESPECTIVELY) FROM EDGE OF ROUGH DOOR OPENING TO FINISH FACE OF ADJACENT WALL.
8. FOR SMOKE/CO ALARM, SEE A111 SERIES RCPs.
9. FOR FIRE EXTINGUISHER CABINETS, SEE AL100
10. PROVIDE SAFETY GLAZING FOR WINDOWS WITHIN 2'-0" OF DOORS, U.N.O.
FLOOR PLAN GENERAL NOTES
11
A
A
B
B
C
C
D
D
E
E
F
F
H
H
G
G
22
33
55
66
44FACE OFSTUD WALLFACE OFSTUD WALLSTUD WALLFACE OFFACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OFSTUD WALLC.O.COL.C.OCOL.C.O.COL.C.O.COL.C.O.COL.3.63.6
COL.
C.O.
C.O.
COL.COL.C.O.COL.C.O.COL.C.O.COL.C.O.STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
STUD WALL
FACE OF
FACE OFSTUD WALLFACE OFSTUD WALL10' - 0"30' - 6"24' - 6"24' - 6"25' - 0"25' - 0"2' - 6"
142' - 0" OVERALL 59' - 0" OVERALL3' - 2" 6' - 2"19' - 8"23' - 0"4' - 0" 3' - 0"
10' - 0"30' - 6"24' - 6"24' - 6"25' - 0"25' - 0"2' - 6"
142' - 0" OVERALL
3' - 2" 6' - 2"19' - 8"23' - 0"4' - 0" 3' - 0"59' - 0" OVERALLSTUD WALLFACE OFXXX
FLOOR PLAN LEGEND
NOTES
SEE G.
DOOR AND DOOR TAGS (FOR CLEARANCES SEE FLOOR PLAN GENERAL NOTES,
FOR ADA APPROACH SEE AG100 SERIES)
WALLS AND WALL TAGS
WINDOW AND WINDOW TAGS
HOSE BIBB
WXX
HB
XXX
FLOOR PLAN SHEET NOTES
1/8" = 1'-0"
LEVEL 1 - FLOOR PLAN1
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2019
BY GRAVES +ASSOCIATES
PROJECT NUMBER:
PM:DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES +ASSOCIATES AND ARE NOT TO BE USED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE
WRITTEN AUTHORIZATION OF GRAVES +ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Retail_epuryear7.rvtFEDERAL WAY MIXED USE(RETAIL)X MARKS THE SPOT, LLC1ST AVE S. &S. 348TH STFEDERAL WAY, WA 98003TG1ST PRICING SET - 07/01/2021
FLOOR PLAN
2002
A101
BC
Key Value Keynote Text #DESCRIPTION//YRMODYA3.10
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #12'-9"SEAL
CONCRETE MASONRY UNIT CAP
(SLOPE TO OUTSIDE)
25'-4"
25'-4"33'-4"4
A4.00SLOPE 2%SPLIT FACED CMU BLOCK
REFUSE COLLECTION AREA
PAIR CHAIN LINK SWINGING GATES. PROVIDE DOUBLE WHEEL
AT LEADING EDGE. PROVIDE PRIVACY SLATS, COLOR TO BE
SELECTED BY ARCH.
2x6 P.T. BUMPER
@ (3) SIDES
1'-6"10'-0"1'-11"1'-8"8'-0"2x6 P.T. BUMPER
@ (3) SIDES9'-0"3'-212"CHAIN LINK SWINGING GATE. PROVIDE PRIVACY SLATS, COLOR
TO BE SELECTED BY ARCH.1'-0"10'-0"1'-0"10'-0"1'-8"10'-0"1'-11"
1'-11"10'-0"1'-6"10'-0"1'-11"
3
A4.00
PRE-CAST
CONC. CAP
CHAIN-LINK GATE/
w/ PRIVACY SLATS MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: CHARCOAL
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: DRIFTWOOD
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: NATURAL
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: CHARCOAL
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: DRIFTWOOD
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: NATURAL
PRE-CAST CONC. CAP
PROVIDE GROUND STOP
SO MAXIMUM GATE SWING
IS 105°
12'-0"
CLR
768 SF
9'-0"8" CMU WALL
1
1
2X6 P.T. WD BUMPER
3'-2 1/2"NOTE:
SEE STRUCTURAL DRAWINGS
FOR INFORMATION ON FOUNDATIONS,
GROUTING AND REINFORCEMENT.TRASH ENCLOSUREA1.0SJSCALE:
TRASH ENCLOSURE PLAN
1/4" = 1'-0"1
SCALE:
TRASH ENCLOSURE ELEVATIONS
1/4" = 1'-0"2
SCALE:
TRASH ENCLOSURE SECTION
1/4" = 1'-0"3
SCALE:
TRASH ENCLOSURE WALL SECTION
3/4" = 1'-0"4 TRASH ENCLOSURE PLANS AND DETAILSA4.00
1
1
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #1PRE-CAST
CONC. CAP
CHAIN-LINK GATE/
w/ PRIVACY SLATS MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: CHARCOAL
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: DRIFTWOOD
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: NATURAL
13'-4"
3'-4"
7'-8"16'-0"CHAIN-LINK GATE/
w/ PRIVACY SLATS MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: CHARCOAL
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: DRIFTWOOD
MUTUAL MATERIALS CMU
8-8-16 SPLIT FACE
COLOR: NATURAL
4
A4.02
SLOPE 2%3
A4.02
176 SF
9'-0"9'-0"8" CMU WALL
1
1
2X6 P.T. WD BUMPER
3'-2 1/2"NOTE:
SEE STRUCTURAL DRAWINGS
FOR INFORMATION ON FOUNDATIONS,
GROUTING AND REINFORCEMENT.TRASH ENCLOSUREA1.0SJSCALE:
TRASH ENCLOSURE PLAN
1/4" = 1'-0"1
SCALE:
TRASH ENCLOSURE ELEVATIONS
1/4" = 1'-0"2
SCALE:
TRASH ENCLOSURE SECTION
1/4" = 1'-0"3
SCALE:
TRASH ENCLOSURE WALL SECTION
3/4" = 1'-0"4 TRASH ENCLOSURE PLANS AND DETAILSA4.01
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #117' - 0"22' - 8 1/2"6' - 7"40' - 8 1/2"4' - 1 1/2"6' - 2"2' - 3 1/2"3' - 3"6' - 10 1/2"1' - 0"2' - 9"6' - 2"2' - 9"5' - 5" 1' - 10"3' - 2"1' - 2 5/8"10' - 1 1/4"3' - 0"8' - 10"
3110 RUSTON WAY, SUITE E TACOMA, WA 98402
PHONE :(253)272-4214
COPYRIGHT, 2021BY GRAVES + ASSOCIATES
PROJECT NUMBER:
PM:
N O T FO R C O N STR U C TIO N
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"x36"REVISIONSDATERE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF
GRAVES + ASSOCIATES AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF GRAVES + ASSOCIATES.REVISIONSDATEC:\Users\epuryear\Documents\2002_Federal Way - Podium_epuryear7.rvtFEDERAL WAY MIXED USE (PODIUM) XMARKS THE SPOT, LLC1ST AVE S. & S. 348TH STFEDERAL WAY, WA 98003TGUPIII IMAGES - 07/15/2021
TRASH ROOM
2002
UPIII-20
BC#DESCRIPTIONMM/DD/YYYY1/4" = 1'-0"
REFUSE ROOM - LEVEL 21 1/4" = 1'-0"
REFUSE CHUTE - LEVELS 4, 5, 6, AND 72
A4.02
366 SF
250 SF
1
DRAWINGS ARE NOT TO SCALE UNLESS PRINTED ON 24"X36"FEDERAL WAYMIXED-USE FEDERAL WAY, WA 98003-UP III SUBMITTALPROJECT:
DRAFTED BY:
2002
UP III SUBMITTAL
BMFEDERAL WAY MIXED USEDRE-USE OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS INSTRUMENTS OF
PROFESSIONAL SERVICE, ARE THE PROPERTY
OF GRAVES + ASSOCIATES AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN AUTHORIZATION OF
GRAVES + ASSOCIATES.2002 / 03.22.20213110 RUSTON WAY, SUITE E
TACOMA, WA 98402
PHONE: 253-272-4214
1UP III REVISION #11 2
43
SITE PHOTO: NORTHWEST SITE PHOTO: NORTHEAST
SITE PHOTO: SOUTHEASTSITE PHOTO: SOUTHWEST
SCALE: N.T.S.SCALE: N.T.S.
SCALE: N.T.S.SCALE: N.T.S.
A5.00