20-102050 -Floor Plan-06-25-2020-V1INTERCOM AND CLOCK SYSTEMSINTERCOM AND CLOCK, WALL MOUNTED FIRE ALARM SYSTEMRELAYSWITCH DEVICE(F = FLOW SWITCH)(T = TAMPER SWITCH)(P = PRESSURE SWITCH)MAGNETIC DOOR HOLD OPEN DEVICEHEAT DETECTORSMOKE DETECTORMANUAL PULL STATIONSTROBE ONLY, WALL-MOUNTEDHORN/STROBE COMBINATION, CEILING-MOUNTEDHORN/STROBE COMBINATION, WALL-MOUNTEDONE-LINE DIAGRAMEQUIPMENT ENCLOSUREBUSWIRETERMINAL / LUGCONNECTIONDELTAWYECURRENT TRANSFORMERCIRCUIT BREAKER, FIXEDDISCONNECT SWITCHFUSEMOTOR CONNECTIONGENERATORMETERING DEVICE(M = METER)(WH = WATT HOUR METER)(A = AMMETER)(V = VOLTMETER)SURGE PROTECTIVE DEVICEGROUNDAVAILABLE FAULT CURRENT (SYMMETRICAL) TAGPANELBOARD - MAIN LUGS ONLYPANELBOARD - MAIN CIRCUIT BREAKERHA-3POWERSWITCHBOARD/SWITCHGEARPANELBOARD, FLUSH-MOUNTEDPANELBOARD, SURFACE-MOUNTED(FRONT)TRANSFORMERPOWER POLE, FLOOR TO CEILINGPOKE-THRU (WHERE INDICATED, SUBSCRIPT INDICATESPOKE-THRU TYPE)MOTOR CONNECTIONDISCONNECT SWITCH, NON-FUSEDDISCONNECT SWITCH, FUSEDCOMBINATION STARTER/DISCONNECTMAGNETIC STARTEREQUIPMENT CONNECTION - CONFIRM CONNECTIONWITH EQUIPMENT MANUFACTURERPUSHBUTTON CONTROLLER(SINGLE OR MULTIPLE BUTTONS)JUNCTION BOXSURFACE METAL RACEWAYRACEWAY CONCEALED IN WALL OR IN CEILING(EXPOSED IN UNFINISHED AREAS)RACEWAY RUN BELOW FLOOR OR BELOW GRADERACEWAY (CIRCLE DENOTES VERTICALTRANSITION)FLEXIBLE RACEWAYHOMERUN TO PANEL(INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER)GENERALEXISTING ELECTRICAL TO BE REMOVEDVARIABLE FREQUENCY DRIVEPULL BOX(WHERE INDICATED, SUBSCRIPT INDICATES PULL BOX TYPE)VAULT(WHERE INDICATED, SUBSCRIPT INDICATES UTILITY VAULT TYPE)HANDHOLE(WHERE INDICATED, SUBSCRIPT INDICATES UTILITY VAULT TYPE)FUSED SWITCHFLOORBOX (WHERE INDICATED, SUBSCRIPT INDICATES FLOORBOX TYPE)SHUNT TRIPGROUND FAULT PROTECTIONELECTRONIC POWER METERPAD MOUNT TRANSFORMERTRANSFORMERFIRE ALARM ANNUNCIATOR PANELFIRE ALARM CONTROL PANELMANUAL MOTOR STARTER WITH THERMALOVERLOADSEMERGENCY POWER OFF PUSHBUTTONEXISTING ELECTRICAL TO REMAINNEW ELECTRICAL WORKMATCHLINE OR PROPERTY LINEDETAIL/PLAN IDENTIFIERSECTION IDENTIFIERELEVATION IDENTIFIERREVISION DEFINITION AREA, AREA ENCIRCLEDCONTAINS CHANGES MADE SUBSEQUENT TOPREVIOUS ISSUEREVISION CALLOUTDEMOLITION NOTE TAGEQUIPMENT TAGFLAG NOTE TAGMECHANICAL EQUIPMENT TAGENCLOSED CIRCUIT BREAKERRACEWAYS AND BOXESFURNITURE WALL FEED OUTLET BOXRACEWAY CONTINUATIONRACEWAY STUB WITH BUSHINGFIRE STOPPING SLEEVERACEWAY SLEEVE WITH BUSHINGCABLE TRAY, 12"W x 4"H OVERHEAD, UNLESSOTHERWISE NOTEDCABLE TRAY, OVERHEAD LADDER TYPE#10(GAUGE OF WIRE OTHER THAN AWG#12)NUMBER OF CONDUCTORS(GROUND CONDUCTOR)(PHASE CONDUCTORS)(NEUTRAL CONDUCTOR)DEVICE SUBSCRIPTS (TYPICAL ALL SYSTEMS)(WP, WG OR OTHER SUBSCRIPT)(NON-STANDARD MOUNTING HEIGHT)WP+80NORTH ARROWFACPFAAPFFFFFSHRTBVFDMJ JFPBXXXXHH XXAA ENLARGED PLAN BOUNDARYE1.11E1.1AE1.1A111AHU-01N1LOCATION WHERE PICTURE WAS TAKEN ANDDIRECTION GXSTGFEPMSPD12,241225480V208Y120V FEEDER TAGFSTROBE ONLY, CEILING-MOUNTEDMJF/SFIRE/SMOKE DAMPERGROUNDING CONDUCTORGROUND RODGROUNDING BUSBARGGROUNDINGEQUIPMENT GROUNDING CONNECTIONGROUNDING STRAPXDRAWING INDEXTELECOMMUNICATIONS SYSTEMTELECOMMUNICATIONS DEVICEABOVE CEILING TELECOMMUNICATIONS DEVICE(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES)(WAP = WIRELESS ACCESS DEVICE)(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES)(W = TELECOMMUNICATIONS WALL PHONE MTD AT +48" AFF)(B = BLANK COVER PLATE)(F = MODULAR FURNITURE DEVICE)(AC = ABOVE COUNTER DEVICE)(S = SURFACE MOUNT)(WAP = WALL MOUNTED WIRELESS ACCESS POINT DATA DEVICE)XWAPXYE-1ELECTRICAL LEGEND AND DRAWING INDEXE-2ELECTRICAL ABBREVIATIONS AND GENERAL NOTESE-3ELECTRICAL SITE PLANE-3.1TELECOM SITE PLANE-4POWER AND FIRE ALARM - ENLARGED PORTABLEFLOOR PLANSE-4.1TELECOM - ENLARGED PORTABLE FLOOR PLANSE-7ELECTRICAL DETAILSE-8.1TELECOM DETAILSE-8.2TELECOM DETAILSE-9ELECTRICAL ONE-LINE DIAGRAM AND DETAILE-9.1LOW VOLTAGE RISER DIAGRAMSE-10ELECTRICAL PANEL SCHEDULES1CLASSROOM AUDIO VISUAL SYSTEMAVX AUDIO VISUAL INPUT PLATE, WALL-MOUNTED(1 = (2) HDMI, USB)FPDFLAT PANEL DISPLAYINTRUSION DETECTION SYSTEMPIR MOTION DETECTOR, WALL-MOUNTEDDOOR POSITION SWITCHS S C O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-1112RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 ABBREVIATIONSNON-STRUCTURAL ELECTRICAL NOTES1.THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROMTHE 2015 INTERNATIONAL BUILDING CODE AND FROMTHE AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)STANDARD 7. THE CONTRACTOR SHALL REFER TO THEABOVE FOR ADDITIONAL INFORMATION, EXCEPTIONS,AND FURTHER DESCRIPTIONS. THE CONTRACTORSHALL ADHERE TO REQUIREMENTS AND AS SUCH,SHALL BE INCLUDED WITHIN BID. ALSO REFER TOSPECIFICATIONS.2.2015 IBC, 1613.1, SCOPE: ARCHITECTURAL,MECHANICAL, ELECTRICAL, AND NON-STRUCTURALCOMPONENTS THAT ARE PERMANENTLY ATTACHED TOSTRUCTURES AND THEIR SUPPORTS ANDATTACHMENTS SHALL BE DESIGNED ANDCONSTRUCTED TO RESIST THE EFFECTS OFEARTHQUAKE MOTIONS IN ACCORDANCE WITH ASCE 7,EXCLUDING CHAPTER 14 AND APPENDIX 11A.3.ASCE 7-02, 11A.1.2.2, CONTRACTOR RESPONSIBILITY:EACH CONTRACTOR SHALL BE RESPONSIBLE FOR THECONSTRUCTION OF A SEISMIC-FORCE-RESISTINGSYSTEM, DESIGNATED SEISMIC SYSTEM, ORCOMPONENT LISTED IN THE QUALITY ASSURANCE PLANSHALL SUBMIT A WRITTEN CONTRACTOR'S STATEMENTOF RESPONSIBILITY TO THE REGULATORY AUTHORITYHAVING JURISDICTION AND TO THE OWNER PRIOR TOTHE COMMENCEMENT OF WORK ON THE SYSTEM ORCOMPONENT. THE CONTRACTOR'S STATEMENT OFRESPONSIBILITY SHALL INCLUDE THE FOLLOWING:A.ACKNOWLEDGMENT OF AWARENESS OF THESPECIAL REQUIREMENTS CONTAINED IN THEQUALITY ASSURANCE PLAN;B.ACKNOWLEDGMENT THAT CONTROL WILL BEEXERCISED TO OBTAIN CONFORMANCE WITHTHE CONSTRUCTION DOCUMENTS APPROVEDBY THE AUTHORITY HAVING JURISDICTION;C.PROCEDURES FOR EXERCISING CONTROLWITHIN THE CONTRACTOR'S ORGANIZATION, THEMETHOD AND FREQUENCY OF REPORTING ANDTHE DISTRIBUTION OF THE REPORTS; ANDD.IDENTIFICATION AND QUALIFICATIONS OF THEPERSON(S) EXERCISING SUCH CONTROL ANDTHEIR POSITION(S) IN THE ORGANIZATION.4.DIVISION 26 RESPONSIBILITIES:A.HANGERS AND SEISMIC BRACING FORELECTRICAL SYSTEMS SHALL BE DESIGNED ANDSPECIFIED BY DIVISION 26. DIVISION 26 SHALLREFER TO THE ELECTRICAL DRAWINGS FORLOCATIONS OF EQUIPMENT AND ELECTRICALSYSTEMS AS STRUCTURAL DRAWINGS DO NOTSHOW THE LOCATIONS OF ELECTRICALEQUIPMENT, RACEWAYS, AND OTHERCOMPONENTS.B.DIVISION 26 SHALL COORDINATE THE SUPPORTSYSTEMS AND DESIGN LOADS FOR HUNGRACEWAYS AND OTHER ELECTRICAL SYSTEMS(INCLUDING COMBINED MULTIPLE RACEWAYRUNS) WITH THE GENERAL CONTRACTOR ANDTHE STEEL AND WOOD JOIST MANUFACTURERSIN ADDITION TO OTHER TRADES THAT MAY BEIMPACTED.GENERAL NOTES1.PERFORM WORK IN ACCORDANCE WITH APPLICABLENATIONAL AND STATE CODES AS AMENDED LOCALLYAND ENFORCED BY THE AHJ.2.OBTAIN AND PAY FOR PERMITS REQUIRED FORINSTALLATION OF WORK. ARRANGE AND SCHEDULEREQUIRED INSPECTIONS.3.COORDINATE WITH UTILITY COMPANIES FURNISHINGSERVICES TO PROJECT. INSTALLATION OF UTILITYSERVICES SHALL BE IN ACCORDANCE WITH UTILITYREQUIREMENTS. VERIFY APPLICABLE INSTALLATIONSTANDARDS AND REQUIREMENTS. PROVIDE ANDSUBMIT ELECTRICAL DRAWINGS TO UTILITY FORAPPROVAL PRIOR TO ROUGH-IN AND PRIOR TOORDERING EQUIPMENT.4.DEVICE LOCATIONS ARE APPROXIMATE. COORDINATEDEVICE LOCATIONS AND ELEVATIONS WITHAPPROPRIATE DOCUMENTS INCLUDING CASEWORKSHOP DRAWINGS AND ARCHITECT'S INTERIORELEVATIONS PRIOR TO ROUGH-IN.5.COORDINATE ELECTRICAL WORK WITH THAT OFOTHER TRADES. REFER TO MECHANICAL,ARCHITECTURAL, STRUCTURAL, CIVIL, ANDLANDSCAPE DRAWINGS AND SPECIFICATIONS.COORDINATION SHALL OCCUR PRIOR TOFABRICATION, PURCHASE, AND INSTALLATION OFWORK.6.COORDINATE LOCATION OF LIGHT FIXTURES ANDCEILING-MOUNTED DEVICES WITH ARCHITECTURALREFLECTED CEILING PLANS AND ELEVATIONS.7.PROVIDE RATED ENCLOSURES AROUND ALL LIGHTFIXTURES PENETRATING RATED CEILINGS.COORDINATE WITH ARCHITECTURAL.8.REFER TO ARCHITECTURAL AND STRUCTURALDRAWINGS FOR LOCATIONS OF EXPANSION/SEISMICJOINTS. PROVIDE RACEWAY EXPANSION/SEISMICJOINTS FOR RACEWAYS CROSSING BUILDINGEXPANSION/SEISMIC JOINTS.9.DEMOLISH EXISTING SYSTEMS AS INDICATED ONPLANS OR AS REQUIRED FOR INSTALLATION OF NEWWORK. MATERIAL SHALL BE REMOVED FROM SITEAND LEGALLY DISPOSED OF OFF SITE UNLESSOTHERWISE DIRECTED. RETURN ITEMS TO OWNER INEXISTING CONDITION WHEN DIRECTED BY OWNER.10.COMPLETION OF WORK SHALL BE EXECUTED INACCORDANCE WITH THE PROJECT SCHEDULE.SCHEDULE INSTALLATION WITH OTHER TRADES TOENSURE PROJECT MILESTONES ARE MET.11.DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOWALL COMPONENTS REQUIRED FOR A COMPLETEINSTALLATION. PROVIDE COMPONENTS REQUIREDFOR COMPLETE AND OPERATIONAL SYSTEMSINCLUDING RACEWAYS, CONDUCTORS, BOXES,SUPPORTS AND SIMILAR ITEMS.12.BRANCH CIRCUIT HOMERUNS ARE SHOWN TOINDICATE CIRCUIT PROPERTIES AND CONFIGURATION. SINGLE-CIRCUIT HOMERUNS SERVED FROM THESAME PANELBOARD MAY BE COMBINED INACCORDANCE WITH THE DIVISION 26 SPECIFICATIONS,UNLESS INDICATED OTHERWISE. EXTEND ANDCONNECT BRANCH CIRCUIT RACEWAY AND WIRINGFROM HOMERUN TO DEVICES AND EQUIPMENT WITHCIRCUIT NUMBERS INDICATED. CONDUCTORQUANTITIES AND SIZES ARE INDICATED ATHOMERUNS ONLY. SHOW ACTUAL RACEWAYROUTING AND CIRCUITING ON RECORD DRAWINGS.MINIMUM CONDUCTOR SIZE #12 AWG.13.LIGHT FIXTURES MOUNTED IN CONTINUOUS ROWSSHALL BE THROUGH-WIRED VIA FIXTURE INTERNALWIREWAYS. CIRCUITS AS INDICATED ON DRAWINGS.FIXTURES NOT LISTED FOR THROUGH WIRING SHALLBE WIRED VIA SEPARATE RACEWAY AND WIRINGSYSTEM EXTERNAL TO THE FIXTURES. PROVIDERACEWAYS, WIRING AND CONNECTIONS FOR ACOMPLETE AND OPERATIONAL SYSTEM.14.LOCATIONS OF RACEWAY, PATHWAY AND SIMILARITEMS ARE SHOWN SCHEMATICALLY. COORDINATEINSTALLATION, INCLUDING BUT NOT LIMITED TOCABLING, TELECOMMUNICATION PATHWAYS ANDSPACES, AND EXACT LOCATION OF HORIZONTAL ANDBACKBONE CABLING WITH LOCATIONS OF FIXEDCASEWORK AND BUILDING CONDITIONS AFFECTINGTHE WORK OF THIS CONTRACT.15.COORDINATE TELECOMMUNICATIONS WORK WITHTHAT OF OTHER TRADES. REFER TO ELECTRICAL,MECHANICAL, ARCHITECTURAL, STRUCTURAL, CIVIL,AND LANDSCAPE DRAWINGS AND SPECIFICATIONS.COORDINATION SHALL OCCUR PRIOR TOFABRICATION, PURCHASE, AND INSTALLATION OFWORK.16.NEW CABLING INSTALLATIONS SHALL BE CONCEALEDIN WALL, CEILINGS, AND BELOW RAISED FLOORSPACES UNLESS OTHERWISE NOTED ON THEDRAWINGS. CABLING IN ACCESSIBLE CEILINGSPACES SHALL BE INSTALLED AS OPEN CABLINGNEAR STRUCTURES AND WALLS OR AS SPECIFICALLYNOTED ON DRAWINGS. SEE SPECIFICATIONS FORSUPPORT REQUIREMENTS.17.PROVIDE FIRESTOPPING SYSTEMS FOR CONDUIT ANDRACEWAY SYSTEMS AT PENETRATIONS, SLEEVESAND SLOTS OF FIRE RATED CONSTRUCTION FORHORIZONTAL AND INTRABUILDING PATHWAYS ANDSPACES.18.INTRABUILDING OPTICAL FIBER CABLING SHALL BECLEARLY AND VISIBLY IDENTIFIED IN PULLBOXES,ENTRANCE POINTS, EACH RISER ROOM, AND 5'-0"BEFORE ENTERING A FREE STANDING RACK UTILIZINGAN OPTICAL FIBER CABLE MARKER TAG SYSTEM.19.CATEGORY 6/6A CABLING: MAINTAIN A MINIMUMSPACING OF 12" FROM ELECTRICAL FEEDERS ANDBRANCH CIRCUIT WIRING AND 12" FROM AUXILIARYSYSTEM CABLING.20.MINIMUM SPACING FROM ELECTRICAL APPARATUSSUCH AS MOTOR DRIVEN EQUIPMENT ANDTRANSFORMERS SHALL BE 6'-0". SPACINGREQUIREMENTS SHALL APPLY TO OPEN CABLINGPATHWAYS WHERE EQUIPMENT IS LOCATED ON THESAME FLOOR, FLOOR ABOVE, FLOOR BELOW, OR INROOMS ADJACENT TO SUCH EQUIPMENT AS THOUGHWALLS AND FLOORS DID NOT EXIST. EXCEPTION:BUILDING CONSTRUCTION THAT RESULTS INCONTINUOUS METALLIC BARRIER BETWEENELECTRICAL APPARATUS AND CABLE PATHWAYSSHALL BE CONSIDERED AS SUITABLE SEPARATION.21.PRIOR TO STARTING TELECOMMUNICATIONSINSTALLATION, CAREFULLY INSPECT INSTALLEDWORK OF OTHER TRADES AND VERIFY THAT SUCHWORK IS COMPLETE TO THE POINT WHERE WORKMAY PROPERLY COMMENCE. NOTIFY THE ARCHITECTAND ENGINEER IN WRITING OF CONDITIONSDETRIMENTAL TO THE PROPER AND TIMELYCOMPLETION OF THE WORK.22.DO NOT BEGIN TELECOMMUNICATIONS INSTALLATIONUNTIL ALL UNSATISFACTORY CONDITIONS ARERESOLVED. BEGINNING WORK CONSTITUTESACCEPTANCE OF CONDITIONS AS SATISFACTORY.23.ROUTE CATEGORY 6/6A CABLES TO THEIR ASSIGNEDCROSS-CONNECT PER THE IDENTIFICATION LABEL ATEACH TELECOMMUNICATIONS WORKSTATION DEVICE.TERMINATE ALL CABLES ON 48-PORT PATCH PANELSON RACKS UNLESS OTHERWISE NOTED.24.THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALLCONDUIT, OUTLET BOXES, JUNCTION BOXES,RACEWAY SYSTEMS, ETC. FOR A COMPLETE ANDOPERATIONAL PATHWAY SYSTEM FOR ALLTELECOMMUNICATIONS SYSTEMS PER THE SCOPE OFWORK INDICATED ON THE CONSTRUCTION DRAWINGSAND BID SPECIFICATIONS.25.CABLE TRAY PATHWAYS ABOVE ACCESSIBLECEILINGS SHALL BE PROVIDED BY THE ELECTRICALCONTRACTOR. CABLE TRAY PATHWAYS BELOWRAISED FLOOR SPACES SHALL BE PROVIDED BY THETELECOMMUNICATIONS CONTRACTOR.MAXMAXIMUMMCMAIN CROSS CONNECT; METAL CLAD (CABLE)MCBMAIN CIRCUIT BREAKERMCCMOTOR CONTROL CENTERMDFMAIN DISTRIBUTION FRAMEMDPMAIN DISTRIBUTION PANELMFRMANUFACTURERMHMANHOLEMINMINIMUMMLOMAIN LUGS ONLYMMMULTIMODEMPOEMAIN POINT OF ENTRYMPOPMAIN POINT OF PRESENCEMTDMOUNTEDMTSMANUAL TRANSFER SWITCH(N)NEWNNEUTRALNACNOTIFICATION APPLIANCE CIRCUITNECNATIONAL ELECTRICAL CODENEMANATIONAL ELECTRICAL MANUFACTURERSASSOCIATIONNFNON-FUSEDNICNOT IN CONTRACTOFCOPTICAL FIBER CABLEOHLOVERHEAD LINEOLOVERLOADOSOCCUPANCY SENSOROSPOUTSIDE PLANTPBXPRIVATE BRANCH EXCHANGEPHPHASEPIRPASSIVE INFRAREDPNLPANELPPPATCH PANELPTPOTENTIAL TRANSFORMERPVCPOLYVINYL CHLORIDEREVREVISIONRMROOMRURACK UNITSHTSHEETSLCSIGNALING LINE CIRCUITSMSINGLEMODESMFCSURFACE-MOUNTED OPTICAL FIBER CABINETSONETSYNCHRONOUS OPTICAL NETWORKSPSERVICE PROVIDERSPDSURGE PROTECTIVE DEVICESPECSPECIFICATIONSSPSTSINGLE POLE SINGLE THROWSTSHUNT TRIPSTPSHIELDED TWISTED PAIRSVGASUPER VIDEO GRAPHICS ARRAYSWSWITCHSWBDSWITCHBOARDTBBTELECOMMUNICATIONS BONDING BACKBONETGBTELECOMMUNICATIONS GROUNDING BUSBARTIATELECOMMUNICATIONS INDUSTRY ASSOCIATIONTMGBTELECOMMUNICATIONS MAIN GROUNDINGBUSBARTPTAMPERPROOFTRTELECOMMUNICATIONS ROOMTTBTELEPHONE TERMINAL BOARDTVTELEVISIONTYPTYPICALUGUNDERGROUNDULUNDERWRITERS LABORATORIESUONUNLESS OTHERWISE NOTEDUPSUNINTERRUPTIBLE POWER SUPPLYUSBUNIVERSAL SERIAL BUSUTPUNSHIELDED TWISTED PAIRVVOLTSVAVOLT AMPERESWWATT; WIREW/WITHW/OWITHOUTWAWORKSTATION AREAWANWIDE AREA NETWORKWPWEATHERPROOFXMFRTRANSFORMERYWYEAAMPEREACAIR CONDITIONING; ALTERNATING CURRENT;ABOVE COUNTERAFAMP FUSE; AMP FRAMEAFFABOVE FINISHED FLOORAGABOVE GRADEAHJAUTHORITIES HAVING JURISDICTIONAHUAIR HANDLING UNITAICAMPERE INTERRUPTING CURRENTALALUMINUMANSIAMERICAN NATIONAL STANDARDS INSTITUTEASAMP SWITCHATAMP TRIPATMASYNCHRONOUS TRANSFER MODEATSAUTOMATIC TRANSFER SWITCHAVAUDIO VISUALAWGAMERICAN WIRE GAUGEBASBUILDING AUTOMATION SYSTEMBATTBATTERIESBILBASIC IMPULSE INSULATION LEVELBKBDBACKBOARDBKRBREAKERBLDGBUILDINGCCONDUIT; DEGREES CELSIUSCABCABINETCATCATEGORYCATVCOMMUNITY ANTENNA TELEVISIONCBCIRCUIT BREAKERCCTVCLOSED CIRCUIT TELEVISIONCLGCEILINGCMCEILING-MOUNTEDCOCONDUIT ONLYCOWCOMPUTER ON WHEELSCTCURRENT TRANSFORMERCUCOPPERDEMARCDEMARCATION POINTDISCDISCONNECTDISTDISTRIBUTIONDSLDIGITAL SUBSCRIBER LINE(E)EXISTINGEAEACHEFEXHAUST FANEIAELECTRONIC INDUSTRIES ASSOCIATIONELEVELEVATIONEMEMERGENCYEMTELECTRICAL METALLIC TUBINGENCLENCLOSUREEPMELECTRONIC POWER METEREPOEMERGENCY POWER OFFEQUIPEQUIPMENTFFUSE; DEGREES FAHRENHEITFAFIRE ALARMFAAPFIRE ALARM ANNUNCIATOR PANELFACPFIRE ALARM CONTROL PANELFBOFURNISHED BY OWNERFOICFURNISHED BY OWNER INSTALLED BYCONTRACTORFOIOFURNISHED BY OWNER INSTALLED BY OWNERFSDFIRE SMOKE DAMPERGGROUNDGBGROUND FAULT CIRCUIT BREAKERGFGROUND FAULT CIRCUIT INTERRUPTERGFPGROUND FAULT PROTECTIONGNDGROUNDGRSGALVANIZED RIGID STEELHCHORIZONTAL CROSS CONNECTHIDHIGH INTENSITY DISCHARGEHPHORSEPOWERIBCINTERNATIONAL BUILDING CODEICINTERMEDIATE CROSS CONNECTIDFINTERMEDIATE DISTRIBUTION FRAMEIGISOLATED GROUNDIMCINTERMEDIATE METALLIC CONDUITISDNINTEGRATED SERVICES DIGITAL NETWORKJJUNCTIONKCMILTHOUSAND CIRCULAR MILSkVAKILOVOLT AMPEREkWKILOWATTLANLOCAL AREA NETWORKLCPLIGHTING CONTROL PANELLECLOCAL EXCHANGE CARRIERLTGLIGHTINGMMETERMANMETROPOLITAN AREA NETWORKC O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-2212RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 (E) MAIN SWITCHBOARD(E) PANEL '4J'FAAPFACP(E) PANEL 'P1'(E) PORTABLE TRANSFORMER(E) UTILITY POLE WITH (E)DISCONNECT AND (E) LOWVOLTAGE SERVICESTXFMR 'T-P1'J (E) FIRE ALARM BOX(E) GRAPHIC MAP WITH INDICATOR LIGHTS(E) FACP IN ADMIN AREA2211189101163455CORE DRILL EXISTING WALLCORE DRILL EXISTING WALLCORE DRILL EXISTING WALL55512121212(E) PANEL '4K'E-3.11MAIN ELECTRICALROOM/ BOILER ROOMMAIN ENTRY ANDADMINISTRATION/RECEPTION AREANEW PANEL '4J'13SPDFLAG NOTES:SHEET NOTES:1.INSTALL NEW UNDERGROUND RACEWAY PER TRENCHING DETAIL ONSHEET E3-1. SURFACE IS CRUSHED ROCK OR SOIL/ GRASS UNLESSOTHERWISE NOTED. WHERE PAVEMENT IS NOTED SAW CUTEXISTING PAVED AREA AND DIG TRENCH TO ACCOMMODATE NEWRACEWAY ROUTING INDICATED. RESTORE PAVED AREA TO MATCHEXISTING CONDITION.2.COORDINATE FIRE ALARM WORK WITH REDHAWK/ADT COMMERCIALOF BOTHELL, WA. POINT OF CONTACT IS JOE SKAVARLA, PHONE NO.(206) 450-8077.3.SURFACE RACEWAY INSTALLED EXPOSED ON EXTERIOR OFBUILDINGS SHALL BE RIGID METAL CONDUIT, NO EXCEPTIONS.4.CEILING TYPES ALONG INTERIOR BUILDING ROUTING INDICATED AREACOUSTICAL TILE UNLESS OTHERWISE NOTED.5.SEAL BUILDING PENETRATIONS WITH APPROVED FIRE PROOFINGAND WEATHER PROOFING MATERIALS.6.SEE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.PROVIDE CONDUIT AND CONDUCTORS FROM PANEL '4J' TOCONDUIT STUB AT EXTERIOR OF PORTABLE FOR THE PORTABLEPANEL. SEE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.PROVIDE GROUNDING AND BONDING IN ACCORDANCE WITHSPECIFICATION SECTION 260526.PROVIDE NEW INDICATOR LIGHTS FOR PORTABLES BUILDINGS/ZONE. PROVIDE WIRING, MODULES, NEW GRAPHIC MAP AND ALLAPPURTENANCES REQUIRED TO MODIFY EXISTING MAP FORPORTABLES AT SCHOOL. UPDATED MAP SHALL BE PRINTED ANDLAMINATED. MAP SHALL INDICATE A TOTAL OF (1) PORTABLE ATTHE SOUTH SIDE OF SCHOOL BUILDING.CORE DRILL EXTERIOR WALL. VERIFY EXISTING SERVICES INWALL PRIOR TO CORE PENETRATION. SEAL PENETRATION WITHAPPROVED FIRE/ WEATHER PROOFING MATERIALS.ROUTE CONDUIT FROM ROOM INDICATED ABOVE ACCESSIBLECEILING TO CONDUIT PENETRATION LOCATION AS INDICATED.PROVIDE CORE DRILL AT WALLS INDICATED.TRANSITION ROUTING FROM UNDERGROUND UP EXTERIOR WALLTO ELEVATION ABOVE BLOCK. PROVIDE NEMA-3R BOX MOUNTEDTO EXTERIOR OF BUILDING FOR POWER AND FIRE ALARM.SAWCUT EXISTING CONCRETE/ASPHALT AND DIG TRENCH FORINSTALLATION OF NEW UNDERGROUND CONDUITS AS INDICATED.PATCH AND REPAIR TO MATCH EXISTING CONDITIONS.COORDINATE WORK WITH OWNER/ENGINEER. DURATION OFEXPOSED TRENCH SHALL BE MINIMIZED AND PAVEMENTRESTORED WITHIN 3 DAYS OF BACKFILL.PROVIDE 1" RIGID METALLIC CONDUIT VERTICAL RISER ONEXTERIOR OF PORTABLE. ROUTE CONDUIT UP TO ELEVATIONAND PROVIDE LB DIRECTLY INTO PORTABLE ABOVE LAY-INCEILING.PROVIDE PORTABLE DISTRIBUTION TRANSFORMER ANDCONCRETE HOUSEKEEPING PAD.DEMOLISH EXISTING PORTABLE BUILDING ELECTRICALCONDUCTORS AND ACCESSIBLE CONDUIT BACK TO EXISTINGEXTERIOR TRANSFORMER. EXISTING TRANSFORMER SHALLREMAIN AS IT SERVES OTHER LOADS. EXISTING TRANSFORMERIS FED OUT OF EXISTING PANEL '4K'.DEMOLISH EXISTING WOOD UTILITY POLE, EXISTING PORTABLEBUILDING DISCONNECT, AND EXISTING LOW VOLTAGE SERVICES.EXISTING APPURTENANCES SERVE EXISTING PORTABLEBUILDING DEMOLISHED BY OWNER.PROVIDE FIRE ALARM CABLING IN CONDUIT TO EXTEND EXISTINGNOTIFICATION AND INITIATING CIRCUITING TO NEW PORTABLEBUILDING. ROUTE IN CONDUIT WHERE EXPOSED AND UTILIZEOPEN CABLING METHODS WHERE ROUTED WITHIN ACCESSIBLECEILING SPACE.DEMOLISH EXISTING PANEL '4J' AND PROVIDE REPLACEMENTPANEL IN PLACE. SEE SHEET E9 FOR ADDITIONAL INFORMATION.12345678910111213C O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-3312N ELECTRICAL SITE PLANSCALE: 1" = 20'-0"1E-3RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 13CORE DRILL EXISTING WALL3CORE DRILL EXISTING WALL3 CORE DRILL EXISTING WALL3PB 5 PROVIDE 18" X 18" X 6" TELECOM PULL BOXPROVIDE 18" X 18" X 6" TELECOM PULL BOX PROVIDE 18" X 18" X 6" TELECOM PULL BOX556(E) MDFIC (E) INTERCOMIDP (E) INTRUSION SYSTEM PANELE-4.11MAIN ENTRY ANDADMINISTRATION/RECEPTION AREA2SHEET NOTES:1.INSTALL NEW UNDERGROUND RACEWAY PER TRENCHING DETAIL.SURFACE IS CRUSHED ROCK OR SOIL/ GRASS UNLESS OTHERWISENOTED. WHERE PAVEMENT IS NOTED SAW CUT EXISTING PAVEDAREA AND DIG TRENCH TO ACCOMMODATE NEW RACEWAY ROUTINGINDICATED. RESTORE PAVED AREA TO MATCH EXISTING CONDITION.2.PROVIDE NEW PULL STRING IN EACH CONDUIT WITH INSTALLATIONOF BACKBONE SYSTEMS CABLING.3.COORDINATE INTERCOM / TELEPHONE WORK WITH ELECTROCOM OFLYNNWOOD, WA. POINT OF CONTACT IS BEN SWERK, PHONE NO.(425) 774-6600.4.SURFACE RACEWAY INSTALLED EXPOSED ON EXTERIOR OFBUILDINGS (WHERE INDICATED) SHALL BE RIGID METAL CONDUIT, NOEXCEPTIONS.5.CEILING TYPES ALONG INTERIOR BUILDING ROUTING INDICATED AREACOUSTICAL TILE UNLESS OTHERWISE NOTED.6.SEAL BUILDING PENETRATIONS WITH APPROVED FIRE PROOFINGAND WEATHER PROOFING MATERIALS.7.SEE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.PROVIDE CONDUIT AND CONDUCTORS FROM MDF TO CONDUITSTUB AT EXTERIOR OF PORTABLE FOR THE PORTABLE IDF ARAE.SEE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.PROVIDE CORE DRILL AT EXISTING EXTERIOR WALL. VERIFYEXISTING SERVICES IN WALL PRIOR TO CORE PENETRATION.ROUTE CONDUIT FROM ROOM INDICATED ABOVE ACCESSIBLECEILING TO CONDUIT PENETRATION LOCATION AS INDICATED.PROVIDE CORE DRILL AT WALLS INDICATED.TRANSITION ROUTING FROM UNDERGROUND UP EXTERIOR WALLTO ELEVATION ABOVE BLOCK. PROVIDE NEMA-3R BOX MOUNTEDTO EXTERIOR OF BUILDING FOR TELECOM AND INTERCOM.PROVIDE THE FOLLOWING OWNER OSP CONDUITS:(2)2"C - TELECOM(1)1"C - INTERCOM(1)1"C - SECURITYROUTE OPEN CABLING IN (E) ACCESSIBLE CEILING SPACE.SEAL PENETRATION WITH APPROVED FIRE/ WEATHER PROOFINGMATERIALS234FLAG NOTES:1567COMPACTED BACKFILL PER NEC300-50(d) & SPECIFICATIONSSECTION 260510FINISHED GRADE6" WIDE X 15 MIL THICK METALLIC TAPE(RED FOR POWER AND ORANGE FORCOMMUNICATIONS), SEESPECIFICATIONS SECTION 260543ELECTRICAL CONDUITS, SEESPECIFICATIONS SECTION 260543SAND BEDDING MATERIAL, SEESPECIFICATIONS SECTION 2605107.5"12"2"2"12"24" MIN.TELECOMMUNICATIONS CONDUIT, SEESPECIFICATIONS SECTION 260543C O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-3.1412N TELECOM SITE PLANSCALE: 1" = 20'-0"1E-3.1 DETAIL - UNDERGROUND PATHWAYSSCALE: NONE2E-4.1RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 NAC(E) PANEL 'P1'IDFP1-10P1-12NAC FWPFFFFHSJHS1IN CEILING SPACEHSJHS123J(1) 1"C - FIRE ALARM45IN CEILING SPACE6FF77P1-1P1-1P1-1FLAG NOTES:SHEET NOTES:1.RACEWAY AND CABLING SHALL BE CONCEALED IN WALLS, ABOVEACCESSIBLE CEILING OR IN CRAWL SPACE UNLESS OTHERWISENOTED.2.PROVIDE CIRCUIT LABELING OF NEW AND EXISTING RECEPTACLESAS SHOWN ON THIS SHEET. SEE DETAIL 2 ON THIS SHEET ANDELECTRICAL IDENTIFICATION SPECIFICATION SECTION 260553 FORADDITIONAL INFORMATION.PROVIDE CONNECTION TO FIRE ALARM SUPERVISION DEVICE.COORDINATE INSTALLATION WITH FIRE ALARM SHOP DRAWINGSPRIOR TO ROUGH-IN.INSTALL RECEPTACLE WITHIN IDF ENCLOSURE. SEE TELECOMFLOOR PLANS AND DETAILS FOR ADDITIONAL INFORMATION.PROVIDE NEW PANELBOARD PHENOLIC NAMEPLATE. SEE DETAIL2 ON SHEET E-9 AND ELECTRICAL IDENTIFICATIONSPECIFICATION SECTION 260553 FOR ADDITIONAL INFORMATION.PROVIDE RIGID METALLIC CONDUIT RISER AS INDICATED. SEEDETAIL 4 ON SHEET E-7 FOR ADDITIONAL INFORMATION.LOCATE NAC PANEL SO THAT TOP OF PANEL ENCLOSURE ISFLUSH WITH CEILING. PROVIDE CONDUIT STUB INTO CEILINGSPACE FROM PANEL FOR LOW VOLTAGE CABLE ROUTING.DEMOLISH EXISTING CONNECTION TO EXISTING WATER HEATERAND PROVIDE BLANK COVER PLANK ON ABANDONED ROUGH-IN.MAINTAIN EXISTING CONDUIT AS SPARE BETWEEN WATERHEATER AND PORTABLE PANEL.PROVIDE RECEPTACLE FOR FLAT PANEL DISPLAY INSTALLED INV2400 SMR. SEE SHEET E4.1 FOR ADDITIONAL INFORMATION.12FIRE ALARM NOTES:1.FIRE ALARM DESIGN AND PERMIT DRAWINGS HAVE BEEN SUBMITTED TOAHJ ON BEHALF OF OWNER BY REDHAWK/ADT COMMERCIAL OFBOTHELL, WA, CONTACT JOE SKAVARLA, (206) 450-8077 FOR ADDITIONALINFORMATION. OBTAIN PERMIT AND PAY FOR ANY REMAINING REQUIREDFEES.2.ROUTE NEW FIRE ALARM CONDUCTORS TO EXTEND EXISTING FIREALARM SYSTEM TO NEW PORTABLES FROM EXISTING MAIN BUILDING.SEE SITE PLAN AND COORDINATE WITH FIRE ALARM VENDOR FINALSHOP DRAWINGS FOR ADDITIONAL INFORMATION.3.PROVIDE NEW FIRE ALARM DEVICES AT LOCATIONS SHOWN. CONDUITAND BACK BOXES FOR WALL MOUNTED DEVICES INDICATED AREEXISTING.4.PROVIDE PROGRAMMING AND COMPONENTS REQUIRED TO UPGRADEEXISTING PANEL TO SERVE NEW PORTABLES.5.OPEN CABLING ABOVE CEILINGS IS ACCEPTABLE.34DEDICATED3/16" LETTERING (TYP)P1-XXADHESIVE CIRCUITIDENTIFICATION LABELDEVICE PLATEIDENTIFICATION PERSPECIFICATION SECTION262726(2.3)(B)RECEPTACLE FACEPLATE IDENTIFICATION DETAILDEVICE PLATE CIRCUITIDENTIFICATION PERSPECIFICATION SECTION260553 (2.1)(B)567C O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-4612N POWER AND FIRE ALARM - ENLARGED PORTABLE FLOOR PLANSSCALE: 1/4" = 1'-0"1E-4RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1Fire alarm portion is for reference only. Not to be used for construction. A separate permit is required for fire alarm installation. FLAG NOTES:SHEET NOTES:1.LOW-VOLTAGE CABLING ROUTED IN ACCESSIBLE CEILING SPACEAND IN CRAWL SPACE SHALL BE SUPPORTED VIA OPEN CABLINGMETHODS.2.RACEWAY AND CABLING SHALL BE CONCEALED IN WALLS, ABOVEACCESSIBLE CEILING OR IN CRAWL SPACE UNLESS OTHERWISENOTED.3.INSTALL NEW LOW-VOLTAGE DEVICES AS SHOWN IN EXISTING SMR.PROVIDE NEW DEVICE PLATES, BLANK COVER PLATES ANDMODIFICATIONS/REPLACEMENTS TO EXISTING SMR PANELS ASREQUIRED TO ACCOMMODATE REMOVAL OF EXISTING INSTALLATIONOF NEW DEVICES SHOWM.USE EXISTING ROUGH-IN. PROVIDE NEW DEVICE AND CABLING.NEMA3R ENCLOSURE ON EXTERIOR WITH CONDUIT SLEEVE INTOIDF AREA. SEE SHEET E-7 FOR ADDITIONAL INFORMATION.PROVIDE BLANK WHITE FACEPLATE AT ROUGH-IN.INTERCOM SPEAKER / DIGITAL CLOCK COMBINATION DEVICESHALL BE INSTALLED IN EXISTING ROUGH IN.PROVIDE D-RINGS ALONG WALL/ PLYWOOD BACKBOARD FROMEXTERIOR NEMA3R ENCLOSURE TO GROMMET OPENING INBOTTOM OF IDF ENCLOSURE FOR BACKBONE CABLING.PROVIDE 3/4" x 4' x 8' PLYWOOD BACKBOARD, PAINTED WHITE.PROVIDE PHENOLIC LABEL FOR EXISTING PANEL IN PORTABLE.LABEL TO MATCH SCHOOL DISTRICTS PORTABLE NAME.PROVIDE DIVIDED 2400 SMR WITH DIVIDED DOUBLE GANG BOXFROM ACCESSIBLE CEILING DOWN TO +6" ABOVE CENTER OFVIDEO DISPLAY, AND INCLUDE ENTRANCE FITTING ATCONNECTIONS TO CEILING. COORDINATE FINAL ELEVATION WITHVIDEO DISPLAY INSTALLATION INSTRUCTIONS.PROVIDE DIVIDED 2400 SMR WITH DIVIDED DOUBLE GANG BOXFROM ACCESSIBLE CEILING DOWN TO AV1 AT STANDARD HEIGHT.INCLUDE ENTRANCE FITTING AT CONNECTIONS TO CEILING.PROVIDE SECURITY MOTION DEVICE IN NEW 4S JUNCTION BOXROUGH-IN AT +7'-6".123456789102 IN IDF ENCLOSURETELECOM CABINET2 2 2 2 2 2 2 S S 1WAP1WAP2 2 111111111111114456E-71E-72PB AV 19FPD1AV 8FPD1AV 8AV 19PROVIDE (2)2"CSEE SHEET E-3.12 12 1S S 1010C O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-4.1612N TELECOM - ENLARGED PORTABLE FLOOR PLANSSCALE: 1/4" = 1'-0"1E-4.1RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 SEE SITE PLAN FORCONDUIT REQUIREMENTS12"X12"X6" NEMA3R PULL BOX(2)2"CCONDUIT SHALL BE PVCCOATED RIGID STEEL, SEESPECS FOR ADDITIONINFORMATIONGABLE END OF ROOFACCESSIBLE CEILINGFLOORPORTABLE SKIRTTELECOM HCENCLOSURE12"X12"X6" NEMA3R PULL BOX(2)2"C TO TELECOMENCLOSURE(2)2"C TO CRAWL SPACESEE HC ENCLOSUREELEVATION FOR CONDUITREQUIREMENTSSHEET NOTES:1.COORDINATE INSTALLATION OF CONDUIT, WIRE, AND OTHERCOMPONENTS WITH ARCHITECT, OWNER & PUD PRIOR TOROUGH-IN.2.CONTACT [CASSIE HOUSER WITH SNOHOMISH COUNTY PUDFOR ALL ELECTRICAL SERVICE REVISIONS. 1-877-783-1000].3.UNDERGROUND CONDUITS SHALL BE INSTALLED PER THETRENCHING DETAIL, SEE DETAIL 3 ON SHEET E-7 FORREQUIREMENTS. ASPHALT/ CONCRETE AREAS ARE NOTED.SAWCUT, PATCH AND REPAIR ASPHALT/ CONCRETE TOMATCH EXISTING CONDITIONS.4.CONTRACTOR SHALL IDENTIFY ALL EXISTING ELECTRICALAND NON-ELECTRICAL UNDERGROUND UTILITIES VIALOCATION SERVICE PRIOR TO TRENCHING OR DRIVINGGROUNDING ROD.5.SEE ONE-LINE DIAGRAM FOR POWER FEEDER CONDUIT ANDCONDUCTOR INFORMATION.6.UNDERGROUND CONDUITS SHALL NOT BE ROUTED BELOWPORTABLE BUILDING OUTLINE.SEE SITE PLAN FORCONDUIT REQUIREMENTS12"X12"X6" NEMA3R PULL BOXACCESSIBLE CEILINGFLOORPORTABLE SKIRT(1)1"C TO FA J-BOX(1)1"CLB WITH (1)1"C TOACCESSIBLECEILING SPACEPITCH SIDE OF ROOFCONDUIT SHALL BE PVCCOATED RIGID STEEL, SEESPECS FOR ADDITIONINFORMATIONGROUNDING ELECTRODE CONDUCTORPER NEC 250.30(A)(5), TABLE 250.66BASED ON SIZE OF PHASE CONDUCTORSOVERSIZE PER (A)(6) IF MULTIPLE SYSTEMSSUPPLY SIDE BONDING JUMPERPER NEC 250.28(D)(1)-(D)(3),TABLE 250.102 (C) (1) MINFEEDER EQUIPMENT GROUNDINGCONDUCTORSPER NEC 250.122NEUTRAL GROUNDING CONDUCTOROVERSIZE IF ALSO USED AS A SYSTEMBONDING JUMPER PER NEC 250.30(A)(1)NEUTRAL BUSGROUND BUSPANELBOARDPER NEC 250.52(A)(2) CONNECT TOGROUND RODSYSTEM BONDING JUMPERDRY-TYPETRANSFORMERABCNEUTRALOR EQUIPMENTPER NEC 250.28(D)(1)-(D)(3),TABLE 250.102 (C) (1) MINSUPPLY SIDE BONDING JUMPERTABLE 250.102 (C) (1) MINEQUIPMENT GROUNDING CONDUCTORPER NEC 250.122 - BASED ON SIZE OFOVERCURRENT PROTECTIVE DEVICEC O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-7712 DETAIL - PORTABLE PATHWAYSSCALE: NONE1E-7 SEPARATELY DERIVED SYSTEM GROUNDINGSCALE: NONE2E-7 DETAIL - PORTABLE FIRE ALARM PATHWAY DETAILSCALE: NONE3E-7RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 RACK 1(1/2)(TYP)(2)BACKBONE NOTES1.PROVIDE (1) 6-STRAND MM INDOOR/OUTDOOROFC FROM MDF ROOM.36415827(2)79RACK COMPONETS:12RU 24"H x 24"W x 30"D WALL MOUNT ENCLOSURE1RU RMFC (X/Y), (X) DENOTES QUANTITY OF 6-LC DUPLEX MMCONNECTOR PANELS, (Y) DENOTES QUANTITY OF BLANKPANELSEQUIPMENT GROUND TO PORTABLE GROUND PER NEC, EIA/TIASTANDARDSCATEGORY 6 48-PORT HORIZONTAL PATCH PANEL1-RU HORIZONTAL CABLE MANAGEMENT PANELPATCH PANEL PORTS DESIGNATED FOR WIRELESS ACCESSCABLING, PORTS 19 - 24 OR 43 - 48 OR AS INDICATED2-1/2"C TO CEILING SPACE/ CRAWL SPACE, (X) DENOTESQUANTITYETHERNET SWITCH (OWNER FURNISHED, OWNER INSTALLED)DUPLEX RECEPTACLE WITH DEDICATED 120V CIRCUIT123456789 IDF-P1 ENCLOSURE ELEVATIONSCALE: NONE1E-8.11IDF-P1-2-03-044-PORT FACEPLATEBLANK MODULE (TYP)CATEGORY 6, 8P8C,MODULAR JACKIDF CABINETRACK DESIGNATIONPATCH PANEL DESIGNATIONPORT DESIGNATIONDRAWING SYMBOL DETAIL - ORGANIZATION AND LABELINGSCALE: NONE2E-8.13/O AWG STRANDEDINSULATED COPPERROUTED TO 20" TMGB#6 AWG STRANDED GREEN SHEATHGROUND WIRE (TYP)3/O AWG STRANDEDINSULATED COPPER TOBUILDING STEELTWO HOLE COMPRESSIONGROUND LUG (TYP)1/4"D x 2"W x 10"L COPPERGROUND BAR WITH WALLMOUNTING BRACKETS ANDINSULATORSEACH EQUIPMENT RACKCONDUITS/ CONDUITSLEEVESOVERHEAD CABLE TRAY/LADDER RACKSYSTEMS HEADEND(S)1.NOT ALL PARTS AND PART NUMBERS ARE SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR ACOMPLETE WORKING INSTALLATION INCLUDING, MISCELLANEOUS APPURTENANCES. THECONTRACTOR SHALL ISSUE A SUBSTITUTION REQUEST FOR CHANGES TO THIS DETAIL.CONTRACTOR SHALL PROVIDE PLENUM RATED SHEATH WHERE REQUIRED.2.ALL GROUNDING CONNECTORS SHOWN SHALL BE DOUBLE LUG, DOUBLE COMPRESSIONTERMINATIONS ON BOTH ENDS.1WAPJ-HOOK SHALL BESUPPORTEDVIA DEDICATED STRINGEROR THREADED RODATTACHED TO STRUCTURE10'-0" SERVICE LOOPSUPPORTED VIA J-HOOKSERVICE LOOP AND SURFACE MOUNT BOXSHALL BE SUPPORTED ABOVE AND OFFTHE CEILING GRID A MINIMUM OF 2'-0"2-PORT SURFACE MOUNT BOXCATEGORY 6A, 8P8C,MODULAR JACK (TYP)DRAWING SYMBOLCATEGORY 6A HORIZONTAL CABLINGTO TELECOMMUNICATIONS ROOM DETAIL - ABOVE GRID WIRELESS ACCESS POINT INSTALLATIONSCALE: NONE3E-8.1 DETAIL - TELECOMMUNICATIONS GROUND BUSBAR ASSEMBLY - 10"SCALE: NONE4E-8.124-PORT FACEPLATEBLANK MODULE (TYP)CATEGORY 6, 8P8C,MODULAR JACK (TYP)IDF CABINETRACK DESIGNATIONPATCH PANEL DESIGNATIONPORT DESIGNATIONDRAWING SYMBOLIDF-P1-2-03-04, 05C O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-8.1812RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 DECORA STYLEFACEPLATEMACHINE GENERATEDLABEL (TYP)DUAL HDMI PASS-THROUGHWITH 10" PIGTAILNETWORK CONNECTION(NOT USED)USB EXTENDER HOSTDRAWING SYMBOLAV1 HDMISOURCE ID/#HDMISOURCE ID/# DETAIL - DUAL HDMI & USB INPUT PLATESCALE: NONE1E-8.2DOUBLE GANGFACEPLATE1-1/2" GROMMETHOLE (TYP OF 2)FPDDRAWING SYMBOL DETAIL - FPD FEED THROUGH PLATESCALE: NONE2E-8.2FLAT PANELDISPLAYSTEREO 3.5MM OUTUSBRS-232HDMIHDMIHDMI/AUDIOUSBHDMIHDMI POWERAV-1CLASSROOM AUDIO VISUAL SYSTEM DETAIL - AV ONE-LINE DIAGRAMSCALE: NONE4E-8.2 DETAIL - UNIVERSAL PUNCH DOWNSCALE: NONE3E-8.2PATCH PANELCENTER CABLE ON110 TERMINALS (TYP)110 TERMINATIONPROTECTION COVERSUPPLIED WITH PANELBEND RADIUSMINIMUM 4 TIMESOUTSIDE CABLEDIAMETERCABLE BEND RADIUSSUPPORT BARVELCROSTRAPSMAINTAIN TIGHT PAIR TWIST UPTO POINT OF TERMINATION(TYP EACH PAIR)MAXIMUM LENGTH OFCONDUCTOR PAIR EXPOSEDBEYOND CABLE JACKET NOT TOEXCEED 1/2" (TYP)PATCH PANEL 110CONNECTOR STRIPC O N S U L T I N G E N G I N E E R SL L C Federal Way, WA 98003 33400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLS SACAJAWEA MIDDLE SCHOOLE-8.2912RECEIVEDCITY OF FEDERAL WAY COMMUNITY DEVELOPMENTJul 07 202020-102050 -Floor Plan-06-25-2020-V1 PANEL '4J' 400A 17,000 400A/3P (E) (2)4"C, 300KCMIL CU, #3G CU (E) PANEL '4J' 400A 300/3 PANEL '4K' 400A 125 #4 NEMA-3R 200N 125/2 480V 208 120V XFMR 'T-P1' 45KVA (E) PANEL 'P1' 200A 200/2(E) 4"C, 350KCMIL CU, #4G CU G N (E) #3/0 PRIMARY DISTRIBUTION BY UTILITY (PUGET SOUND ENERGY) (E) (5)4"C, 500KCMIL CU, 350KCMIL G CU (E) UTILITY PAD MOUNT TRANSFORMER 2000AS/1600AFA V M REMOTE UTILITY METER (E) SWITCHBOARD 'MD4' 2000A, 480/277V, 3PH, 4W 30K AIC WESTINGHOUSE CIRCA 1968 17,000 12,340 2 #6 1 1 3 4 3 5 NOT ALL EXISTING DISCONNECTS ARE SHOWN AS A PART OF THIS DIAGRAM (E) 350 KCMIL 9,671 EQUIPMENT PHENOLIC NAMEPLATE DETAIL NONE 2 E-9 PANEL 'P1' VOLTAGE: 208Y/120V FED FROM: XFMR 'T-P1' INSTALLED: YYYY XFMR 'T-PORT' PRIMARY VOLTAGE: 480V SECONDARY VOLTAGE: 208Y/120V FED FROM: PANEL '4J' FEEDS: PANEL 'P1', PORTABLE P1 INSTALLED: YYYY TRANSFORMER TAG PANELBOARD TAG YEAR INSTALLED (TYP) SCREWS OR RIVETS (TYP) DETAIL NOTE: 1. SEE SPECIFICATION SECTION 260553 FOR ADDITIONAL INFORMATION. SACAJAWEA MS - ELECTRICAL ONE-LINE DIAGRAM SCALE: NONE 1 E-9 SPD NEW OR EXISTING PANELBOARD SEE PLANS AND ONE-LINE DIAGRAM PROVIDE FLUSH MOUNT ADAPTER WHERE PANELBOARD IS INSTALLED FLUSH WITH WALL SURGE SUPPRESSION (SPD) DEVICE, INSTALL AS CLOSE TO BREAKER SERVING DEVICE AS POSSIBLE. REFER TO PANEL SCHEDULES FOR BREAKER LOCATION PRIOR TO ROUGH-IN. NO 90 DEGREE BENDS IN CONNECTING CONDUIT ALLOWED. PROVIDE SHORTEST POSSIBLE WIRING LENGTH FOR CONNECTION, MAXIMUM OF 18". SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS PROVIDE 30A/3P BREAKER FOR CONNECTION OF SPD DEVICE TO PANELBOARD INDICATED. ADJUST LOCATION AS REQUIRED FOR CLOSEST POSSIBLE PROXIMITY TO NEUTRAL BUS PROVIDE SPD NEUTRAL AND GROUND CONNECTIONS DIRECTLY TO NEUTRAL AND GROUND BUS AT PANELBOARD TYPICAL SPD DEVICE INSTALLATION NONE 3 E-9 6 6 EXISTING 2000A MAIN SWITCHBOARD: 12-MONTH PEAK DEMAND = 239kW 239kW / 0.9 = 265.6kVA 265.6kVA X 125% = 332kVA REVISED 400A PANEL 4J: ADJUSTED DEMAND = 332kVA ADDED DEMAND OF PORTABLE ADDITIONS = 36kVA TOTAL DEMAND = ADJUSTED + ADDED = 368kVA 368kVA/(480V x SQRT(3)) = 443A NEW CALCULATED DEMAND DOES NOT EXCEED THE AMPACITY OF THE FEEDERS OR BUS SUPPLYING POWER TO THESE LOADS. SACAJAWEA 12 MONTH DEMAND CALCULATION: STUDY WAS PERFORMED FROM 2/26/20-4/20/20. AN OCCUPATIONAL ADJUSTMENT WAS NOT REQUIRED AS THE BUILDING WAS OCCUPIED DURING THE PEAK DEMAND. A SEASONAL ADJUSTMENT FACTOR OF 1.076 HAS BEEN APPLIED TO ALIGN WITH THE 12-MONTH DEMAND FOR THE MAIN SERVICE. EXISTING 400A PANEL 4J: 30-DAY PEAK DEMAND = 95.5 kVA 95.5 kVA X 125% = 119.4kVA REVISED 400A PANEL 4J: ADJUSTED DEMAND = 119.4kVA ADDED DEMAND OF PORTABLE ADDITIONS = 36kVA TOTAL DEMAND = ADJUSTED + ADDED = 155.4kVA 155.4kVA/(480V x SQRT(3)) = 187A x 1.076 = 201.3A NEW CALCULATED DEMAND DOES NOT EXCEED THE AMPACITY OF THE FEEDERS OR BUS SUPPLYING POWER TO THESE LOADS. SACAJAWEA 30-DAY DEMAND CALCULATION: FEEDER SCHEDULE COPPER CONDUCTORS TAG QUANTITY RACEWAY CONDUCTORS OF SETS SIZE PHASE NEUTRAL GND(NOTE 2) 125 1 2"#1/0 -#6 200N 1 2-1/2"#3/0 #3/0 #6(#4) NOTES: 1.COPPER FEEDERS ARE BASED ON COPPER CONDUCTORS WITH THWN/THHN INSULATION. CONDUCTOR DERATING IS BASED ON THWN/THHN CONDUCTORS WITH 90 DEGREES C RATING. 2.GROUND CONDUCTOR (BONDING JUMPER) SIZE SHALL BE INCREASED FOR FEEDERS FROM THE SOURCE OF A SEPARATELY DERIVED SYSTEM TO THE FIRST DISCONNECTING MEANS PER NEC 250.30(A). SIZE AS INDICATED IN PARENTHESES. FLAG NOTES: SHEET NOTES: 1.NEW BREAKERS SHALL MATCH EXISTING PANEL MANUFACTURER AND AIC RATING. GROUND PER NEC & WAC STANDARDS. EQUIPMENT SHALL BE SERVICE ENTRANCE RATED. DEMOLISH EXISTING PANELBOARD AND PROVIDE REPLACEMENT PANELBOARD AS INDICATED. PROVIDE CONDUIT AND CONDUCTORS REQUIRED TO RECONNECT EXISTING BRANCH CIRCUITS AND EXISTING BRANCH FEEDERS TO MATCH EXISTING AND PROVIDE CONDUIT AND CONDUCTORS TO SERVE NEW PORTABLE TRANSFORMER AND PORTABLE PANELBOARD. SEE SHEET E3 FOR ADDITIONAL INFORMATION. DISCONNECT EXISTING FEEDERS FROM EXISTING TRANSFORMER. EXISTING FEEDERS SHALL BE RECONNECTED TO REPLACEMENT TRANSFORMER. PROVIDE SUBFEED TYPE CIRCUIT BREAKER. SEE SHEET E10 FOR ADDITIONAL INFORMATION. PROVIDE LOCKABLE TYPE CIRCUIT BREAKER AND LABELING IN ACCORDANCE WITH NEC 450.14 AND NEC 110.25. 1 2 3 4 5 6 C O N S U L T I N G E N G I N E E R SL L CFederal Way, WA 9800333400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLSSACAJAWEA MIDDLE SCHOOLE-9 10 12 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Jul 07 2020 20-102050 -Floor Plan-06-25-2020-V1 (E) UNIT B (E)MDF (ROOM B22) (E) ROOM B18 PROVIDE 1-RU RMFC WITH (3) 6-LC DUPLEX MULTIMODE OPTICAL FIBER ADAPTER PANELS AND (2) BLANK PANELS. CONFIRM EXACT LOCATION WITH OWNER'S REPRESENTATIVE. NEW PORTABLE P1 OFC (E) INTERCOM HEADEND (TELECENTER) CRAWL SPACE ACCESSIBLE CLG SPACE IDF ENCLOSURE IDF-P1 NEW PORTABLE P1 CRAWL SPACE ACCESSIBLE CLG SPACE 4-PAIR (1) 6-STRAND 50/125 MULTIMODE OFC E8.01 1 (1) INTERCOM CABLE RMFC (E) RACK (E) UNIT B TELECOMMUNICATIONS RISER DIAGRAM SCALE: NONE 1 E-9.1 INTERCOM / CLOCK RISER DIAGRAM SCALE: NONE 2 E-9.1 C O N S U L T I N G E N G I N E E R SL L CFederal Way, WA 9800333400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLSSACAJAWEA MIDDLE SCHOOLE-9.1 11 12 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Jul 07 2020 20-102050 -Floor Plan-06-25-2020-V1 C O N S U L T I N G E N G I N E E R SL L CFederal Way, WA 9800333400 8th Ave S, Suite 205FEDERAL WAY PUBLIC SCHOOLSSACAJAWEA MIDDLE SCHOOLE-10 12 12 RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Jul 07 2020 20-102050 -Floor Plan-06-25-2020-V1