20-102519-Permit FinalCity of Federal Way
Community Development Dept,
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Building - Commercial
Permit #:20-102519-00-CO
Inspection Request Line: (253) 835-3050
Project Name: WATERBURY PARK APARTMENTS
Project Address: 32905 19TH PL S Parcel Number: 797880 0360
Project Description: ***BLUEBEAM ELECTRONIC REVIEW***
Construction of wooden ramp and wood framed stairs for accessing dog park.
Owner Applicant Contractor Lender
THRIVE COMMUNITIES MIROSLAV DOYTCVHEVMK T B CONSTRUCTION OWNER IS LENDER
1518 1ST AVE S SUITE 500 ENGINEERING LLC 3329 153RD ST SW
SEATTLE WA 98134
12212 155TH AVE SE LYNNWOOD WA 98087
RENTON WA 98059
Census Category: 999 - Unknown
Includes: 1 92 3 4
occupancy Class:
Construction Type:
Occupancy Load:
Floor Area (sq. ft.)
Additional Permit Information
Mechanical to be Included? .................................... No Number of Stories.....................: . l
Is this an Online or O.T.C. application? .................. No Permit for Building Shell Only?............................. No
Plumbing to be Included? ................... I....................
No
Total Valuation: 12,000.00
No Fixtures Associated With This Permit 11
PERMIT EXPIRES Saturday, 16 January, 2021
Permit Issued on Monday, July 20, 2020
hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washingto'and the City of Federal Way.
Owner or agent: ate:
As
CITY or
Federal Way
THIS CARD IS TO REMAIN ON -SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 20 102519 00 Address:
Project: THRIVE COMMUNITIES
32905 19TH PL S
FEDERAL WAY WA 98003
Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS GURU. Inspections are listed as close to sequential order as possible
read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
Initial Erosion Control (4365) Footings/Setback (4110) 0 Foundation Wall (4115)
To be done PRIOR to breaking ground ppro ao place concrete Approved to place concrete
er T1 WW
By Date i:3 Date,.7, By Date
0 Drainage/Downspout (4040) Re -steel (4215) Q Slab/Concrete Floor (4255)
Approved to backfill Approved to place concrete or grout Approved to place concrete
By Date By Date By Date
Underfloor Framing (4285) Floor Sheathing (4105) Shear Walls (4245)
Approved to sheath floor Approved to install flooring Approved to install siding
By Date By Date By Date
1"L=J Roof Sheathing (4220) Fire/Draft Stops (4095) Interim Erosion Control (4370)
Approved to install roofing Approved Approved
By Date By Date By Date
Prior to scheduling a Framing inspection; El Framing (4120) Insulation (4150)
Electrical, Plumbing & Mechanical Rough -in
and Fire/Draft Stop inspections must be signed- p/
Ap oved to insulate
pn a
Approved to install wallboard
off and approved. iBC ]09.3.4
By L Date By Date
El Gypsum Wallboard Nailing (4130) 0 Suspended Ceiling Grid (4265) I a t Final - S K F & R (4060)
Approved to install mud & tape Approved to drop Tile Approved
By Date By Date By Date
1l Final Erosion Control (4375) El Fina Il - Building (4050)
T
Approved y " IrA pio ed
By Date By
iS
Date
Rough Electrical Final Electrical Right of Way
Approved Approved Approved
By Date By Date By Date