Loading...
20-103150-SITE PLANConst Values Exposure.................... Frost Depth Seismic Zone.............. Ground Snow Roof Snow.................. Wind ASD Wind ULT.................... Eng S1 Value Eng SS Value............. Footing Size First Floor Joists......... First Floor Spacing Second Floor Joists.... Second Floor Spacing Insul Wall.................... Insul Ceiling Insul Ceiling HD.......... Insul Floor Roof Sheathing........... Wall Sheathing Floor Sheathing........... GWB Ceiling GWB Firewall.............. GWB Wall 1st Floor Ceiling Ht...... 2nd Floor Ceiling Ht State.......................... 0.0 SqFt 525.09 SqFt Infinity % Floor Areas Total Living Space = Total Glazing Area = Glazing Percentage = Area Summary Main Floor:1662 Sq. Ft. Basement:765 Sq. Ft. Conditioned Area:2427 Sq. Ft. Unfinished Basement: 534 Sq. Ft. Garage Area:523 Sq. Ft. Covered Deck: 156 Sq. Ft. Covered Porch: 70 Sq. Ft. Open Decks:210 Sq. Ft. Minimum Roof Venting Requirements #Evaluation Error# Preferred Roof Venting Requirements #Evaluation Error# To get each Area to showup...enter "Area_Initialize_Rooms"into CA Generated Room Label B 18" D 25 lbs 25 lbs 85 mph 110 mph 0.0 0.0 8" x 16" #Evaluation Error# 16 #Evaluation Error# 16 R-21 R-49 R-38 R-30 7/16" 7/16" 3/4" 5/8" 1/2" 1/2" #Evaluation Error# #Evaluation Error# WA 4329 SW 314th StFederal Way, WA 98023253-359-0109Parcel # - 8731990310PobletePrinted On: 7/30/2020 15:40:55 Sheet:4001 72nd St. E.Tacoma, WA 98443Gabe SpruellPh: 253.312.5523---These plans are exclusive property of Pacific Home Source (PHS) and may not be sold to any person or business without expressed written consentof PHS. These plans are for one (1) time use only for PHS's customer - Poblete and to be built on the customer's site at 4329 SW 314th St in FederalWay, WA 98023.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architectural work" under sec. 102 of the copyright act,17 USC as amended December 1990. The protection includes but is not limited to the overall form as well as the arrangement and composition ofspaces and elements of design. Under such protection, any unauthorized use of these plans, the design in whole or part, can legally result inmonetary compensation to PHS. Written permission must be obtained and granted prior to any use and/or design changes to these plans.---Any variations from conditions and dimensions shown on the drawing shall be reported to the designer for resolution prior to proceeding with thework, otherwise the contractor shall be solely responsible for costs of any necessary remedial work.PACIFICHOMESOURCELLCPHS Job #: 20.089 M) Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote A) Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. N/A U-Factor (A)R-Value (A)All Climate Zones 0.042 Ceilng Below Grade Wall (C,K) Mass Wall R-Value (I) N/A Floor Fenestration U-Factor (B) Skylight U-Factor Glazed Fenestration SHGC (B,E) Wood Frame Wall (G,K,L) Slab (D) R-Value & Depth N/A 49 (J) 21/21 (H) 30 (G) 21 INT 10/15/21 INT+TB 0.50 10, 2ft 0.30 N/A 0.056 N/A 0.026 0.056 0.029 A) R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. B) The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. C) "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. D) R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. E) There are no SHGC requirements in the Marine Zone. F) Reserved. G) Reserved. H) Reserved. I) The second R-value applies when more than half the insulation is on the interior of the mass wall. J) Reserved. K) For Single Rafter or Joist Vaulted Ceilings, the Insulation may be reduced to R-38. L) Reserved. Option Description Credit(s) 2015 IECC Energy Code Information Below are the Chosen Options for the 2015 Energy Code 5A 0.5 EFFICIENT WATER HEATING 5A: All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the maximum flow rates for all showerheads, kitchen sink faucets, and other lavatory faucets 5A 0.5 EFFICIENT WATER HEATING 5A: All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the maximum flow rates for all showerheads, kitchen sink faucets, and other lavatory faucets Drafting Manager: Gabe Spruell Pacific Home Source 4001 72nd St. E. Tacoma, WA 98443 253.312.5523 Customer: Poblete 4329 SW 314th St Federal Way, WA 98023 253-359-0109 Parcel # - 8731990310 Builder: Company Name Contact Name Address Phone Number Email Address Design Criteria & Loads (Verify with Engineer) Roof Snow Load:25 psf Floor Live Load: 40 psf Wind Speed (ASD):85 mph Wind Speed (ULT):100 mph Exposure:B Seismic Zone:D Frost Depth:18" 3D Isometric Drawings are for illustration ONLY! Plans, Details and Engineering take presidence over ANY 3D drawing within this plan. Applicable Codes 2015 International Building Code (IBC) 2015 International Residential Code (IRC) 2015 International Energy Conservation Code (IECC) 0000 W/ Washington State Amendments **Address MUST be located on the house where it is easily seen from the main access road (Homeowner Responsibility).** P / L P / L P / L P / LP / LP / LP / LP / L P / L P / L P / LP / LP / LP / LN N 36°32'07" E101.11'N 39°15'41" E101'N 5 0 ° 4 4 ' 1 9 " W 7 5 ' N 5 0 ° 4 4 ' 1 9 " W 7 9 . 8 1 ' Existing 2427 Sq. Ft. Residence Existing 522 Sq. Ft. Garage S W 3 1 4 t h S t Existing Concrete Driveway 873199-0310 11x17 Scale: 1" = 20' 22x34 Scale: 1" = 10' DN Room Name Garage 23'-0" x 21'-0" Bedroom 10'-0" x 11'-3" Bedroom 9'-6" x 8'-11" Master Bdrm11'-6" x 14'-4" Living 15'-2" x 30'-0" 85 CFM Whole House Fan Covered Deck17'-0" x 12'-0"Open Deck12'-0" x 5'-6"Master Bath10'-3" x 6'-2"Shower4'-9" x 4'-8"W.I.C.10'-3" x 5'-8"Pantry 3'-8" x 5'-8" 50 CFM 50 CFM50 CFM Kitchen12'-6" x 23'-8"Omit Bearing Wall Project Description: Take out section of wall between kitchen and dining room Push kitchen to back wall of dining nook and rework kitchen and pantry Shrink Master to accommodate laundry closet new location Make Laundry room the new common bathroom to expand master walk-in closet area Rework master bathroom to accommodate 5 piece master bathroom (add windows as shown) New roofing per builder New exterior panting Sheet Index Pg #Title 1 Cover Sheet 2 Existing Elevations 3 Existing Elevations 4 Existing Floor Plan 5 Proposed Elevations 6 Proposed Elevations 7 Proposed Floor Plan 8 Existing Basement 9 Foundation & Framing 10 Roof Framing 11 Cross Sections 12 Details 13 Details Continued 14 General Notes Layout Sheet # 1 of 14 Cover Sheet 1 Poblete Interior Remodel RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Aug 27 2020