Loading...
99-103725105 sf. �m sf. 258 S1 ' .... nr's218 rK r' v ' I�IOD4'1A O[TQt1G'tD=u• '48 sf.'tJ�IQ7.01 IOGOLiC Dili yrQ�EH[ .�I''pCC u7C 7' O �11 ` 240 sf. 0L ooa000[ 330 WA rN SA 138 sf Pro •l - \ INSTALL HYPERICUM ® W 0 C. -- THROUGH OUT BED, WORK AROUND a �C EXISTING SHRUBS AND TREES. TO N 01105'12" E -15' WIDE TYPE (1) BUFFER /rxcI X (t2 1T\ 10, 32 -- �� p loj � OL1De,� 218 _PEDESTRIAN PLAZA' MIN. 200S.F. ' _ 12.23-99 202 sf We £# signGxou landscape Architecture 2329 East Madison St. Site Planning Seattle, Washi ton 98112 Developmental Planning (201322-1732 LANDSCAPE CALCULATIONS: 1.) Total Significant Trees (12" cal. and over) existing on site: 30 trees Total Significant Trees required to remain (25%): 8 trees Total Significant Trees proposed to remain (50%): 15 trees 2.) See legend for listing of drought tolerant species. Minimum of 25% of plants listed are drought tolerant. 3.) All landscape areas are to be irrigated with an automatic, water -conserving, irrigations system (36,094 s.f. new irrigation) 4.) Total Number of Parking Lot Stalls: 331 stalls Total Area of Parking Lot Landscape required: 7282 s.f. (22 s.f. per parking stall.) Total Area of Parking Lot Landscape provided: 17,594 s.f. (53 s.f. per parking stall.) 5.) Total Area of New Pedestrian Plaza: 572 s.f. 6.) Total New Landscape area: 36,094 s.f. 7.) Total New Area Drought Tolerant Landscape 20,200 s.f., 10' WIDE TYPE (3) BUFFER (56 / of total new landscape area) �2.23.9g Z \ 298 sf. \ 1 \ X 10' WIDE TYPE (3) BUFFER i i NORTH "HEALING GARDEN - ENLARGEMENT" LANDSCAPE YLAN APPR Permit Nlvmber, -D Approved By: 7/) Date: 1110 0 d 111 = 10'-0•• 0' 15' 3a 60' 99 STATE OF WASHINGTON PEG D S� ARCHITECT wElannAri SCALE 1"= 30'-0" CERTIFICATE 321 XREF: ARCHITECTURE 777 108th NE #400 Bellevue WA 98004 425.822.6700 425.828.9116 Fax MEDICAL CENTER FEDERAL WAY AMBULATORY SURGERY CENTER No. Date Item Revisions PER CITY COMMENTS 8-27-99 PER CITY COMMENTS 12-23-99 2 7-_ I> cn Project No. 1097 y Date 6/21/99 D 77 Drawn By LPN � � 2pp0 PRELIMINARY �( Title LANDSCAPE PLAN 2) d Sheet No. L l , 0 NPH 6/21/99 L1—PLNT LANDSCAPE LEGEND (Min. 25% of plants to be drought tolerant. *Indicates drought tolerant species.) SYMBOL QTY. BOTANICAL / COMMON NAME MIN. SIZE / CONDITION / REMARKS EXISTING VEGETATION: Significant Tree (12" cal. and over) To Remain Significant Tree (12" cal. and over) To be removed Exist. Tree (under 12" cal.) To Remain Exist. Tree (under 12" cal.) To be removed Existing Shrub Bed to Remain Existing Lawn to Remain DECIDUOUS TREES: 3 Acer palmatum 'Sango Ill Sango Kaku Japanese Maple 4 Cercidiphyllum japonicum Katsura Tree 6 Prunus yedoensis Yoshino Cherry 10 Quercus rubra Red Oak 10 Zelkova serrata Zelkova CONIFEROUS TREES: Save and protect where shown to remain. ZI I., full, well -branched, matched, B&B or )cal., ainer, spacing as shown on plan. 2" full, well -branched, matched, B&B or ainer, spacing as shown on plan. 2" full, well -branched, matched, B&B or ainer, spacing as shown on plan. 2" full, well -branched, matched, B&B or ainer, spacing as shown on plan. 2" full, well -branched, matched, B&B orainer, spacing as shown on plan. 13 8 65 19 *Calocedrus decurrens Incense Cedar *Pinus sylvestris Scotch Pine *Pseudotsuga menziesii Douglas Fir *Thuja plicata Western Red Cedar LARGE SHRUBS: 6'-7' ht., full and bushy to base, B&B or container, spacing as shown on plan. 6'-7' ht., full and bushy to base, B&B or container, spacing as shown on plan. T-8' ht., full and bushy to base, B&B or container, spacing as shown on plan. 6'-T ht., full and bushy to base, B&B or container, spacing as shown on plan. 6 Camellia japonica var. 30"-36" ht., full and bushy, spacing as Camellia varieties shown on plan. 1 CD Magnolia stellata Min. S ht., specimen, well-branced, Star Magnolia full, spacing as shown on plan. 70 *Myrica californica 24"-30" ht., full and bushy, spacing as Pacific Wax Myrtle shown on plan. 35 Rhododendron 'Unique' 24"-30" ht., full and bushy, spacing as or equal shown on plan. 3 Syringa vulgaris var. 30"-36" ht., full and bushy, spacing as Common Lilac shown on plan. 10 Viburnum p. tomentosum 24"-30" ht., full and bushy, spacing as Doublefile Viburnum shown on plan. MEDIUM SHRUBS: O 34 Abelia g. 'Sherwoodii' 18-24" ht. / spread, full and bushy, Abelia spacing as shown on plan. G 32 *Arbutus unedo 'Compacta' 24" ht., full and bushy, spacing as Compact Strawberry Tree shown on plan. O 146 *Cistus hybridus 24" ht. / spread, full and bushy, White Rock Rose spacing as shown on plan. C 59 Euonymus alata 'Compacta' 24" ht., full and bushy, spacing as Compact Burning Bush shown on plan. O 13 Hydrangea quercifolia 18"-24" ht., full and bushy, spacing as Oakleaf Hydrangea shown on plan. D 88 *Mahonia aquifolium 24" ht., full and bushy, spacing as Oregon Grape shown on plan. p 29 *Nandina d. 'Moyer's Red' 24" ht., full and bushy, spacing as Moyers Red Heavenly Bamboo shown on plan. 38 *Osmanthus delavayi 18"-24" ht., full and bushy, spacing as Delavay Osmanthus shown on plan. p 33 Pieris japonica'Forest Flame' 24" ht., full and bushy, spacing as Forest Flame Pieris shown on plan. Q 104 Prunus I. 'Zabeliana' 24" ht., full and bushy, spacing as Zabel Laurel shown on plan. ® 16 Rhododendron 'PJM' 18"-24" ht., full and bushy, spacing as PJM Rhododendron shown on plan. 25 *Ribes sanguineum 24" ht., full and bushy, spacing as Red Flowering Currant shown on plan. O 27 *Taxus media'Brownii' 24" ht., full and bushy, spacing as Yew shown on plan. 0 38 Viburnum I. 'Spring Bouquet' 24" ht., full and bushy, spacing as Spring Bouquet Viburnum shown on plan. It Cu��Pe( LANDSCAPE LEGEND CON'T. (Min. 25% of plants to be drought tolerant. *Indicates drought tolerant species.) SYMBOL QTY. BOTANICAL / COMMON NAME MIN. SIZE / CONDITION / REMARKS SMALL SHRUBS: ®� 3 Azalea 'Coral Bells' Kurume Azalea or Equal 106 *Berberis verruculosa Warty Barberry c 94 *Berberis t. 'Rose Glow' Rose Glow Barberry o� 9 Daphne b. 'Somerset Somerset Daphne e E e 5 Escallonia 'Newport Dwaf Escallonia opo 26 Ilex crenata 'Northern Beauty' Northern Beauty Japanese Holly CPO 37 Leucothoe f. 'Rainbow' Rainbow Leucothoe CPO 21 Pieris j. 'Variegata' Variegated Pieris 000 78 *Pinus mugo'mugo' Mugho Pine Apo 24 *Prunus L 'Otto Luyken' Otto Luyken Laurel 36 Sarcococca ruscifolia Sarcococca FERNS & GRASSES: 15" spread, full and bushy, spacing as shown on plan. 15"-18" ht. / spread, full and bushy, spacing as shown on plan. 18" ht., full and bushy, spacing as shown on plan. 15"-18" ht. / spread, full and bushy, spacing as shown on plan. 15"-18" ht. / spread, full and bushy, spacing as shown on plan. 18" ht., full and bushy, spacing as shown on plan. 15"-18" spread, full and bushy, spacing as shown on plan. 18" ht., full and bushy, spacing as shown on plan. 15" spread, full and bushy, spacing as shown on plan. 15"-18" ht. / spread, full and bushy, spacing as shown on plan. 18" ht., full and bushy, spacing as shown on plan. 14 Carex morrowii 'Variegata' 1 gal., full, healthy leaves, spacing as Variegated Japanese Sedge shown on plan. 12 Miscanthus s.'Yaku Jima' 2 gal., full, healthy leaves, spacing as Yaku Jima Maiden Grass shown on plan. 18 Polystichum munitum 1 gal., min. (8) leaves, full, healthy, Western Sword Fern spacing as shown on plan. PERENNIALS: 1 gal. cont., full, start first row 8" from 75 Alchemilla mollis I Lady's Mantle edge of planting area, typ., quantities as Lavandula stoechas I Spanish Lavender noted on the plan. Geranium 'Johnson's Blue' / Geranium Heuchera 'Palace Purple'/Coral Bells Hosts var. I Hosta Helleborus orientalis I Lenten Rose Hemerocallis var. I Daylilies Erysimum 'Bowles Mauve / Bowles Mauve Iris siberica / Siberian Iris GROUNDCOVERS: 4" pots @ 24" triang. spacing, full, start first row 8" from edge of planting 1756 aphylos *A uva-ursi l area, typ., quantities as noted on the Kinnitro ikin nick plan. 2115 *Cotoneaster dam meri / Bearberry Cotoneaster 387 *Hypericum calycinum 1 St. John's Wort 250 Vinca minor / Dwarf Periwinkle 45 Sarcococca h. humilis I Sarcococca 1 gal. cont., full, start first row 8" from 30 Viburnum davidii / David's Viburnum edge of planting area, typ., quantities as 58 *Gaultheria shallon / Salal noted on the plan. 2419 s.f. NEW SEEDED LAWN AREA: See specifications r� AREA INCLUDED IN PARKING LOT LANDSCAPE CALCULATIONS 124 sf 1 a .. We... ,° " 1gnGroup PS Landscape Architecture 2329 East Madison St. Site Planning Seattle, Washinggton 98112 Developmental Planning (206) 322-1732 DECIDUOUS TREE 1/2" dla. BLACK RUBBER HOSE 12 GA WIRE (3) 2X2 D.F. STAKES INTO SUBGRADE SPECIFIED MULCH FINISH GRADE IMPORT TOPSOIL (SEE SPECS) PULL BURLAP OFF TOP 1/3 OF ROOTBALL PLANTING BACKFILL, CREATE PEDESTAL TO SUPPORT ROOTBALL BREAK UP SIDES AND taw i CPALL Gila. BOTTOM OF PIT. Deciduous Tree Planting 3/8" = 1' - 0" 2X2 HEM -FIR STAKE DRIVEN TO REFUSAL SECURE TO TREE WITH (2) STRANDS NURSERY- MAN'S TAPE POINT TOP OF STAKE TOWARD PREVAILING WIND SPECIFIED MULCH FINISH GRADE IMPORT TOPSOIL (SEE SPECS) PULL BURLAP OFF TOP 1/3 OF ROOTBALL PLANTING BACKFILL BREAK UP SIDES AND BOTTOM OF PIT. ,c i GV I_ C 10. Coniferous Tree Planting 3/8" = 1' - 0" LOP 1 �,,•1 3/8" = 1' - 0" PLANT SHRUBS AT SAME GRADE AS NURSERY FOLD BACK OR REMOVE BURLAP FINISH GRADE SPCIFIED MULCH IMPORT TOPSOIL (SEE SPECS) PLANTING BACKFILL B 4 B OR CONTAINER AS SPECIFIED LANDSCAPE PLAN APPROVAL Permit; ember. `) o 5-9y Approved By: Date: t Comments: t STATE OF WASHNGTON REGI D LA A"RCHH,TECT CERTFICATE NO. 321 ARCHITECTURE 777 108th NE #400 Bellevue WA 98004 425.822.6700 425.828.9116 Fax MEDICAL CENTER FEDERAL WAY AMBULATORY SURGERY CENTER No. Date Item Revisions PER CRY COMMENTS 8-27-99 RE -ISSUE 12-23-99 Project No. 1097 Date 6/21/99 Dram By RESUBMI-17E JAN 0 4 2000 PRELIMINARY Title LANDSCAPE LEGEND Sheet No. L1.1 XREF: NPH 6/21/99 L1—PLNT 21/2 „ II/4 „ B2 L 21-___—Qr — — — — — — ' GPM I I u g /2 3,4n ,,� ,,, ,,, 1 „ - - - - _ _ _ P We signGxoup _ 1/4 2 I „ ,i i, 3 „ O +2'z'Y,n.. r ,. INC.PS 1 /4 11/4 1 , n /4 3/ „ 3/4 " Site Planning — I 3j4 3/4 " \ Landscape Architecture 2329 East Madison St. 4 I" 1'/4 ' Developmental Planning Seattle, Wa(2 ton -1732 I I , � P 9 (20G� 322.1732 B1 4 i" \ 1„ I 3j4„ 12.0 \ 1 GPM 51.0 ® 11'4„ 34n E15 11 I /4" 3 Gf'M // 2 ` 3/ „ 1 /4" 4 B3 21/ ` CONNECT NEW 2-1/2'' 0' 15' 30' 60' 99 I" 3 I 22" 3/4' 2 3/4 -I/2" 21/2" /�-8 Y 3/4" \ 1" MAINLINE TO EXISTING /4 ° 3 �� 3 �;. - - - \MAINLINE IN /4 1" /4 In II/4,i 81Y 23.5 I1/a" 111/2" 2" 3/4" /4 OXIMATE GPM 2, 2" �slY � 11/4„ Q SHU ATOFF VALRvEVAND 3/ „ 3/4 7ME EH= > 3/4 " 11/21. 3„ 3/411 DETAIL\COUPLER PER NORTH SCALE 1"= 30'-0 4 r " EXISTING ME/4 3'411 sl2" 2„ B4 3,4 - I I,2 3/ , I \ - CONNECT NEW W 2-I/2" MAINLINE T 3j4" 2 4 3/a" " ,4� /a" 3/4,i MAINLINE IN APPROXIMATE � 3, D LOCATION. PROVIDE SHUT-OFF VALVE RELOCATED VALVE FOR ` " \ NEW ZONE SUMMARY • 4 ANQUICK COUPLER PER DETAIL. ZONE NE "q, GPM 16.5 3ja 1. 3/4 ,4,i 1 MAKE MINOR MODIFICATION 3M VALVE _ - � ZONE GP EXISTING TO EXISTING ZONE TO = TYPE MAINLINE I = PROVIDE OPTIMUM o SIZE I I � EXISTING HEADS COVERAGE WITHMINI y \ B1 72.0 1-1/2" SHRUB -v TO REMAIN ` OVERSPRAY 2,,2 B2 21.5 1" LAWN ( UNDISTURBED I 0 4 \"\ MV 3/4'i B4 16.5 ill SHRUB (PART OF Z1/2" SHRUB I fro) ONE EXISTING I ����� 2 \ B5 63.5 1 1/2" LAWN IRRIGATION TO 33.0 1' B6 65.5 1-1/2" SHRUB REMAIN ° UNDISTURBED - I © , \ `'3�`G B7 57.2 1-1/2" LAWN TYP. 1/2" B8 32.4 1-1/2" SHRUB EXISTING 3/4 ` 1" - I" --=I - COURTYARDII/2" „ -- 1 8IV I" 4 I \ EX MEDICAL OFFICE BLDG ' o - I F �._ 3/4u 1" 11/4 i, FF = 332.5± { 11/4" I„ �slV p, \ EXT'G COPPER BASEMENT FF = 319.5 LATERALNCONTRACTOR TO c � I 2 ''' " � I/4 _ 3 ' -. r \ 3/4" *IV 11/ - VERIFY LOCATION _ a 0 ---------------------- --------------- IP�RIOOR TO ANY f 111/2 - I 1 3,4„ I Ems„ `` RK 1/44i'-A _ EXTEND NEW I" 1" COPPER LINE ` 330 _?Q3® - G COOPER LINE AND (SEE MECH) I PM ------------ I" _. - RECONNECT TO 3/4" 3, 11,4, ' \ EXT G ZONE 18 IN 4 „ -___- -- CONTROL L ER -.__ - PROPOSED AMBULATORY CENTER I1/ " 2 ON" MAINLINE NEW ` 6 APPROX. � s I Y 4 / \ LOCATION, 2" II/2„ 11/4, TO EXISTING LOCATE CONTROLLER INSIDE MEGH. ROOM 2IV "ii4" 3/a IN APPROX. LOCATION SHOWN. VERIFY WITH / ARCHITECT. WALL MOUNT CONTROLLER AT 1" 3, " 3/ " — —� 2 AOf'�R TE 21/� , 21/ „ NLIN EYE LEVEL. PROVIDE SEPARATE 15 AMP 3/4" a — • OXIMA /2 / - N 1 CIRCUIT AND 120 VAC POWER TO B7 51.2 '21/ „ E6 2„ �1" 0j4" I CONTROLLER. PROVIDE 1-1/4'' CONDUIT 1-1/2„ GPM 3/„ 2 I„ E5 63 FROM CONTROLLER TO NEAREST PLANTING 4 ' /4 _I�„ 1" I2 GP 3/ , 4 3/4 i, I" Iu - PLAN IN BED, 1. EXTEND GRADE. INTO ' 128 11/a" PLANTING BED, IS" BELOW GRADE. GAP CONNECT NEW 2" ` II/2" 1I/4 I�� 11,4„ 3j4" / II/2" AND FLAG. I MAINLINE TO EXT'G 1 GPM 1 VALVE 018 IN ` ,, 3/4" CONNECT NEW 2YI2" 1 0 APPROX. LOCATION. 3/4 2 I" / MAINLINE TOEXISTING 32.4 1" /4 3/4 3 I" MAINLINE APPROXIMATE /4 / EXISTING IRRIGATION O PM B8 I --- - '' • 3,4i, LOCATION TO REMAIN UNDISTURB E -I/2" ARCHITECTURE 777108th NE #400 Bellevue WA 98004 425.822.6700 425.828.9116 Fax MEDICAL CENTER FEDERAL WAY AMBULATORY SURGERY CEN TER 3/4 " D 0 0 2" MAINLINE ® / APPROX. 21/2 MAINLINE MAINLINE CONNECT NEW 2-1/2 3/4 / LOCATION OF MAINLINE TO EXISTING 0000, 3/4" _ _ — — _-_ EXT'G ZONE 014 MAINLINE IN 3/4 4/ 3, , APPROXIMATE ;1 ------ ----- -- -__ — ------------- LOCATION 1 ` -3/4Q / / PROVIDE NE -12" / 1 RELOCATED APPROX. LOCATION 3/4" MAINLINE W 6" SLV vALV MII 3,4,i OF VALVE FOR 1" 3/4" „ AT NEW L41 LK / 1 11 EXISTING ZONE " IS TO EXISTING IRRIGATION / 60 / 1, REMAIN. TO REMAIN UNDISTURBED // 1 1 34 1, I" I No. Date Item 1 I/ 3i" E9 1 ; 4 4 1 „ 1 I/4 0 In I 1" 1 I II/4" 1 �" / / Revisions /4 3PER CITY COMMENTS 12-23-99 epm /4 " - � - - - u / /I ,1 I1/4" EXISTING ONE SUMMARY 11,„ / I" 4 Ill 11/43,4' 2 MODIFICATION TO EXISTING SYSTEM IS BASED ON DESIGN 11'2" B6 E9 68.3 / / / DRAWINGSIDATED OCT. 15TH, 1986 PREPARED BY ALBERTER I2" GPM 3j4„ 1, 36.8 11/4 3 -12 GPM I„ E7 PM GGPM EG STAAND ASSOCIATES. 1 AI1/4" II/4u 1„ 1„ /4 3/4u /� ,4n 211/2" / -1/2" / Z REMARKS 1 LOCAPJU T ION AS 3j4+ 4 3/4 E8 1 RELOCATED E1 RELOCATE VALVE - DEMOLISH PORTION OF HEADS -MODIFY AS NECESSARY Pro'ect No. 1097 1 SHOWN TYP. C 1 � / 3 56.0 -12 / VALVES "1 / E2 RELOCATE VALVE - REMOVE EXISTING HEADS I O 21 I �—�__>--- ' �� ' �,4—r_� � 3/4 Gam/ / AND 8 E4 RELOCATE REMOVE EXISTING HEADS TO REMAIN UNDISTURBED Date 9/3/99 D E5 TO REMAIN UNDISTURBED ADJUST LOCATION Drawn B /q SEM 1 r�l EXISTING ZONE 010, AS SHOWN TYP. 3i4" E6 RELOCATE VALVE - REMOVE EXISTING HEADS Y F / E7 S MAKE MODIFICATIONS RELOCATE VALVE -REMOVE EXISTING HEADS AS SHOWN EXT'G 1-12"—( 21, „ i � A 1 E8 RELOCATE VALVE -REMOVE EXISTING HEADS �EXT'G I-1/4"�� �/ EXT'G 3/4" / E9 VALVE TO REMAIN - ADD HEADS AS SHOWN J N 0 4 1000 E10 TO REMAIN - MAKE MODIFICATIONS AS SHOWN �v7 1 � 0 LOCATION OF Y / XISTING ZONE "9. E11 RELOCATE VALVE -REMOVE EXISTING HEADS �dnnb� 1 EXISTINGJ2 /� / MAKE MODIFICATIONS E12 CAP AND ABANDON HEADS AS NECESSARY �U XXX MAINLI E v / A5 SHOWN Title XXX �� E13 TO REMAIN UNDISTURBED S E14 TO REMAIN UNDISTURBED E15 RELOCATE VALVE - REMOVE EXISTING HEADS E16 TO REMAIN UNDISTURBED ' E17 TO REMAIN UNDISTURBED STATE OF E18 EXISTING VALVE TO REMAIN - REMOVE PORTION OF ZONE WASHINGTON E19 TO REMAIN UNDISTURBED s G ARCHITECT Sheet No. CERTFlCATE NO. 321 SEE SHEET L2.1 F[)R IRRIMA III I crcklr% A I.lr, r%r-T All L2.0 0 n FINISH USE BOTTOM INLET ONLY PVC, RISER, SAME SIZE AS INLET 12" X 5/4" 5GH aO NIPPLE SHRUB or LAPIN HEAD TOP FLUSH W/FINISH 6RADE (2) THxTH 5GH 40 ELLS rv/2" x 3/4" 5GH 80 NIPPLE or (2) MARLEX STREET ELLS W/o NIPPLE r 5GH 40 THxTH ELL or MARLEX STREET ELL G TEE or ELL, BUSHING FPVC A5 REQUIRED. PVC, LATERAL burial depth per specifications NOTES: I. TEMPORARILY GAP RISERS FOR PRESSURE TESTING. 2. SEAL ALL JOINTS W/TEFLON TAPE ON MALE THREADS ONLY. 3, DO NOT OVERTIGHTEN GALV. to PVC JOIN75. 4. ALL THREADED PVC, PIPE SHALL BE 50H 80, ALL PVC. FITTINGS SHALL BE SGH. 40. 5. NO CL05E NIPPLES PERMITTED. 6. ALL FITTINGS and PIPE SAME dla. AS LP.5. FEMALE CONNECTION OF SPRINKLER HEAD or Q.G. T. INSTALL 50 PIPING WILL NOT CONTACT LATERAL. ELEVATION PVC TH SCH TO NIPPLE 3" LONG (2) PVC, 5T. ELLS SHRUB LAWN HEAD Shrub / Lawn Head NTS PLASTIC VALVE BOX AMETEK (OR EQUAL) WITH LOCKING LID AND EXTENSIONS AS REQUIRED TOP OF LID FLUSH WITH FINISH GRAI FLC 2 CU, FT. DR ROCK SUMP Shut-off Valve NTS IRRIGATION NOTES PVC TEE or ELL, WITH BUSHING AS REQUIRED, PVC TH X TH 9O deg. ELL PVC TH 5GH 50 NIPPLE 8" LONG FINISH GRADE QUICK COUPLER PVC 56H. 80 NIPPLE 8" min. LENGTH PVC, MAINLINE burial depth per spec Fir otions PVC TH X TH 90 deg. ELL (NO 5TREET ELL) ELEVATION PVC TH 5GH TO NIPPLE 3" LONG — (2) GALV. ST. ELL5 QUICK COUPLER PLAN B Quick Coupler NTS "'x'ISH GRADE ,IT OFF VALVE C MAINLINE SPORT EACH VALVE )X WITH (4) BRICKS I T F' CAL AMETEK 5-1/4" POLYIRON VALVE BOX, TOP SECTION, W/COVER, BUSHING A5 REQUIRED GALV. NIPPLE VARIABLE LENGTH AS REQUIRED (2) GALV. STREET ELL W (1) 5GH. 60 SHORT NIPPLE. (NO MARLEX). PVC, TEE or ELL, W/ BUSHING / A5 REQUIRED. PVC TEE or ELL, WITH BUSHING AS REQUIRED. PVC TH X TH 90 deg. ELL PVC TH SGH 80 NIPPLE 8" LONG 1) EXISTING IRRIGATION MAINLINES TO BE REUSED WHERE POSSIBLE IN AREAS WHERE IRRIGATION REVISIONS OCCUR. FINISHED PRODUCT SHALL BE A COMPLETE AND UNINTERRUPTED SYSTEM THROUGHOUT THE SITE. CONTRACTOR IS TO VERIFY LOCATION AND SIZE OF MAINLINE SERVICING EXISTING SYSTEM PRIOR TO START OF ANY WORK. CONNECT NEW MAINLINE TO EXISTING MAINLINE IN APPROXIMATE LOCATION SHOWN, AND ADJUST AS REQUIRED. 2) LOCATION OF IRRIGATION MAINLINE, LATERALS, SLEEVING AND VALVES ARE SCHEMATIC ONLY AND SHALL OCCUR IN PLANTING AREAS UNLESS SLEEVING IS SHOWN. MAKE MINOR ADJUSTMENTS AS REQUIRED TO COORDINATE WITH AS -BUILT DIMENSIONS AND CONDITIONS. 3) DURING INSTALLATION OF THE WORK NOTE ANY LOCATIONS OF EXISTING IRRIGATION INFRASTRUCTURE ENCOUNTERED, AND CLEARLY NOTE ON NEW RECORD DRAWINGS TO INCORPORATE ALL IRRIGATION ON THE PROJECT FOR OWNER USE. 4) WHERE SLEEVING IS REQUIRED ACROSS EXISTING ASPHALT SAW CUT AND EXCAVATE A SMOOTH, STRAIGHT, EVEN TRENCH. AFTER INSTALLATION OF THE PIPING OR WIRING REPLACE WITH SPECIFIED MATERIAL AND COMPACT TO MINIMUM 95% MODIFIED PROCTOR METHOD. REPAIR ALL ASPHALT IN ACCORDANCE WITH CIVIL PLANS AND DETAILS. 5) CONSTRUCTION OF THE IMPROVEMENTS SHOWN ON THIS PLAN REQUIRES CONNECTIONS TO, AND PARTIAL DEMOLITION OF THE EXISTING IRRIGATION SYSTEM. CONTRACTOR SHALL MAKE ANY REQUIRED MODIFICATIONS TO LAYOUT SHOWN TO CONFORM TO ACTUAL AS -BUILT LOCATIONS OF EXISTING SYSTEM COMPONENTS TO BE RE -USED. 6) AFTER INSTALLATION OF THE NEW IRRIGATION, RUN THE ENTIRE SYSTEM THROUGHOUT THE SITE TO MAKE SURE THAT THERE IS CONTINUITY TO ALL ZONES, FLUSH THE ENTIRE SYSTEM MAKING SURE THAT THERE ARE NO CONTAMINANTS WHATSOEVER IN THE NEW OR EXISTING PIPING. 7) ADJUST ALL IRRIGATION HEADS TO PROVIDE MAXIMUM COVERAGE, MINIMUM OVERSPRAY AND NO FOGGING. SET ALL HEADS BACK FROM CURBS, PAVING AND WALLS AS SPECIFIED. VARIATION IN THEIR LOCATION ON THE PLAN IS ONLY FOR THE SAKE OF GRAPHIC CLARITY. 8) REPAIR ALL PLANTING AREAS DISTURBED BY MODIFICATIONS TO EXISTING OR NEW IRRIGATION SYSTEM. 9) CAP AND ABANDON ALL IRRIGATION PIPING AND SLEEVING FROM EXISTING IRRIGATION SYSTEM NOT BEING USED IN RECONSTRUCTED SYSTEM. 11" X 17" VALVE BOX, INSTALL FLUSH W/ FIN15H GRADE. FINISH GRADE II PVC, BUSHING MAINLINE�� CONTROL WIRES AND SPARE, TAPE TO BOTTOM OF MAINLINE -TYP. PVC UNION INSTALL 3" DEPTH MIN. OF 5/4'' DRAIN ROCK IN BOTTOM OF VALVE BOX. NOTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. Remote Control Valve NTS IRRIGATION LEGEND Symbol Item Manufacturer / Cat NO. Description -Remarks m 16 ROTOR HUNTER PGM 06-A-V 30 PSI ADJUST RADIUS AS REQUIRED, NOZ.75 - QUARTER HEAD INSTALL PER DETAIL'A', THIS SHEET NOZ. 1.5 - HALF HEAD AUTOMATIC, CONTROL VALVE ®� ® ® LAWN / SHRUB HEAD RAINBIRD 180X-15-U SERIES 30 PSI ADJUST RADIUS AS REQUIRED, (1804-LAWN, 1806-SHRUB) INSTALL PER DETAIL'A', THIS SHEET CONTROL WIRE W/2 I.F. COILED IN BOX o p LAWN I SHRUB HEAD RAINBIRD 18OX-12-U SERIES 30 PSI ADJUST RADIUS AS REQUIRED, �bJiY�in6.11�11ultl�ll Q (1804-LAWN 1806-SHRUB) INSTALL PER DETAIL'A' THIS SHEET �a 0 N a 6 FLoW z F SUPPORT VALVE BOX WITH (4) BRICKS-TYP. PVC, S X TH ADP. MIN. 4" PVC, 5GH. aC NIPPLES (BOTH ENDS of VALVE) p o p LAWN / SHRUB HEAD RAINBIRD 180X-10 SERIES 30 PSI ADJUST RADIUS AS REQUIRED, (1804-LAWN, 1806-SHRUB) INSTALL PER DETAIL'A', THIS SHEET ® ® LAWN / SHRUB HEAD RAINBIRD 180X-08 SERIES 30 PSI ADJUST RADIUS AS REQUIRED, (1804-LAWN, 1806-SHRUB) INSTALL PER DETAIL'A', THIS SHEET m o LAWN / SHRUB HEAD RAINBIRD STRIP SERIES 30 PSI ADJUST RADIUS AS REQUIRED, 18OX-15 EST, SST INSTALL PER DETAIL'A', THIS SHEET (1804-LAWN, 1806-SHRUB) ® ® LAWN / SHRUB HEAD RAINBIRD STRIP SERIES 30 PSI ADJUST RADIUS AS REQUIRED, 180X-B-15 SST INSTALL PER DETAIL'A', THIS SHEET (1804-LAWN, 1806-SHRUB) ® SHRUB HEAD RAINBIRD 1806-04 VAN SERIES 30 PSI ADJUST RADIUS AS REQUIRED, INSTALL PER DETAIL'A', THIS SHEET ® CONTROL VALVE RAINBIRD 100-PEB, 150-PEB REMOTE CONTROL VALVE, INSTALL PER DETAIL'C', THIS SHEET © CONTROLLER RAINBIRD ESP-12MC 12 STATION CONTROLLER WALL MOUNT IN BLDG IN APPROX. LOCATION AS SHOWN ON PLAN m SHUT-OFF VALVE AQUA (2") 200 PSI THREADED ENDS. INSTALL PER DETAIL 'D', THIS SHEET ® QUICK COUPLER RAINBIRD NO. 5RC INSTALL WHERE SHOWN ON PLAN PER 55K-1 KEY SH-2 SWIVEL DETAIL'B', THIS SHEET. PROVIDE HOSE ELL (2) KEYS AND (2) ELLS. MAINLINE LATERALS -------- SLEEVES ON SIZE VALVE NUMBER VALVE SIZE PVC-SCH. 40 18" MIN. BURIAL DEPTH. SIZES AS NOTED ON PLAN. PVC -CLASS 200 SIZE AS PER PLAN, 3/4" MIN, UNLABELED PIPE SECTIONS TO MATCH THE LARGEST OF THE ADJACENT PIPES. UNLABELED PIPE AT THE END OF LATERAL RUNS TO BE 3/4". 12" MIN. BURIAL DEPTH. PVC -CLASS 200 SLEEVES TWICE THE DIAMETER OF PIPE INSIDE. BURIAL DEPTHS AS REQUIRED FOR PIPES. EXTEND SLEEVES 12" INTO PLANTING AREAS. CAP AND FLAG LOCATION. STRAIGHT RUNS ONLY. EXISTING 2-1/2" MAINLINE EXISTING IRRIGATION HEADS — — EXISTING LATERALS 10) ADJUST EXISTING IRRIGATION AND PROVIDE TEMPORARY SERVICE AS REQUIRED TO PROVIDE CONTINUOUS SERVICE DURING INSTALLATION TO WATER ALL LANDSCAPE AREAS THAT MAY BE AFFECTED DURING CONSTRUCTION. PROVIDE PERMANENT ADJUSTMENTS TO THESE ZONES TO INSURE THAT ALL ISLANDS AND PLANTING AREAS RECEIVE WATER. HAND WATER ANY AREAS TEMPORARILY THAT DO NOT RECEIVE WATER DURING PROJECT DURATION, SYSTEM READJUSTMENTS AND CONSTRUCTION (INCLUDING INTERIOR COURTYARDS). 11) TIE NEW VALVES INTO EXISTING MAINLINE AND SPARE WIRE IN APPROXIMATE LOCATIONS SHOWN. PROVIDE ALL NECESSARY PARTS AND WIRING. REPAIR ANY DAMAGE TO EXISTING IRRIGATION INCURRED DURING CONSTRUCTION. 12) WHERE EXISTING VALVE IS SHOWN TO BE RELOCATED, EXTEND EXISTING VALVE WIRES AS NECESSARY. PROVIDE WATER TIGHT SPLICES IN APPROVED JUNCTION BOXES. EXISTING VALVE MAY BE REUSED PROVIDED IT IS FREE OF DEFECTS. 13) REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 14) REFER TO CIVIL DRAWINGS FOR GRADING INFORMATION. H EXISTING VALVES �F We' signGroup landscape Architecture 2329 East Madison St. Site Planning Seattle, Washington 98112 Developmental Planning (206) 322-1732 STATE OF WASHINGTON REGI D 5� ARCHITECT v MM CM"nFr_A NO. 321 ARCHITECTURE 777 108th NE #400 Bellevue WA 98004 425.822.6700 425.828.9116 Fax MEDICAL CENTER FEDERAL WAY AMBULATORY SURGERY CENTER No. Date Item Revisions PER CITY COMMENTS 8-27-99 RE -ISSUE 12-23-99 Project No. 1097 Date 9/3/99 Drawn By SEM RESUSMITTEL) JAN 0 4 2000 IRRIGATION Title LEGEND AND DETAILS Sheet No. L 2 ,1 XREF: SEM 9-3-99 L2—IRRG