18-101558 (2)AL.
A.F.F
CAB.
CLG.
CMU.
COL
CON.
CONC.
CONST.
CONT.
CPT.
CTR.
CT.
C.J.
C.O.
DIA.
DIM.
DISP.
DIV.
DR.
DS.
DTL.
DWG.
DWR.
EA.
ELEC.
EL
EMER.
EQUIP
EQ.
EXH.
EXIST.
EXP.
EXT.
E.J.
FA.
FD.
FE.
FIN.
FLR.
FOC.
FOF.
FOM.
FOS.
FRP.
FTG.
FT.
FURR.
F.R.
GALV.
GA.
GD.
GL
GYP.
G.C.
GWB.
r01111 a /nstant Oi/ Chan e
9
PACIFIC HIGHWAY SOUTH
FEDERAL WAY, WA. 98003
�.P
S a,,aytn si
114,
St. Francis Hospital
S 34&th St
b
s
s.
West Hylebos
Wetlands Park
SW 3561h St S 3561h St
ALUMINUM
ABOVE FINISHED FLOOR
BOARD
BUILDING
BLOCKING
BEARING
CABINET
CEILING
CONCRETE MASONRY UNIT
COLUMN
CONTRACTOR
CONCRETE
CONSTRUCTION
CONTINUOUS OR CONTINUE
CARPET(ED)
COUNTER
CERAMIC TILE
CONTROL JOINT
CASED OPENING
DIAMETER
DIMENSION
DISPENSER
DIVISION
DOOR
DOWNSPOUT
DETAIL
DRAWING
DRAWER
EACH
ELECTRICAL
ELEVATION
EMERGENCY
EQUIPMENT
EQUAL
EXHAUST
EXISTING
EXPANSION
EXTERIOR
EXPANSION JOINT
FIRE ALARM
FLOOR DRAIN
FIRE EXTINGUISHER
FINISHED)
FLOOR ING))
FACE OF CONCRETE
FACE OF FINISH
FACE OF MASONRY
FACE OF STUD
FIBERGLASS REINFORCED PANEL
FOOTING
FOOT OR FEET
FURRED (ING)
FIRE RESISTANT
GALVANIZED
GAUGE
GRADE OR GRADING
GLASS
GYPSUM
GENERAL CONTRACTOR
GYPSUM WALL BOARD
w
w
S
m S 336th St
Q
KITTS CORNER
6:
K
ry
N
99
S 3491h St _18
�COMO Wholesale
4
0
Y'
Todd Beamer v
s aaom se
s sa4m sz
ABBREVIATIONS
HC.
HOLLOW CORE
TEL TELEPHONE
HC.
HANDICAPPED
TEN. TENANT \ OWNER \ FRANCHISEE
HM.
HOLLOW METAL
TYP. TYPICAL
HORIZ.
HORIZONTAL
T.C.C. TENANTS CABINET CONTRACTOR
ID.
INSIDE DIAMETER
T.E.C. TENANTS ELECTRICAL CONTRACTOR
INST.
INSTALLER
T.G.C. TENANTS GENERAL CONTRACTOR
INSUL
INSULATION
INT.
INTERIOR
U.O.N. UNLESS OTHERWISE NOTED
JT.
JOINT
VCT. VINYL COMPOSITION TILE
VERT. VERTICAL
LAM.
LAMINATE
VT. VINYL TILE
LAV.
LAVATORY
V.I.F. VERIFY IN FIELD
LL.
LANDLORD
WC. WATER CLOSET
MATL
MATERIAL
WD. WOOD
MAX.
MAXIMUM
WWF WELDED WIRE FABRIC
MDF.
MEDIUM DENSITY FIBER
BOARD W/ WITH
MECH.
MECHANICAL
W/0 WITHOUT
MFG.
MIN.
MANUFACTURER
MINIMUM
St�Z1#ll King
9 Fire &
MIR.
MIRROR
Approved
MISC.
MISCELLANEOUS
❑ As Detalied
M0.
MASONRY OPENING
''Subject ttached details
MTL
METAL
By
N.I.C.
NOT IN CONTRACT
NOM.
NOMINAL
Date In-3 I
NTS.
NOT TO SCALE
��
-)�' RW14r4S 46.0 (IyE,w4ycPA sr)
OA.
OVERALL
RMWE A •2, A (o 4 11
OD.
OUTSIDE DIAMETER
�
OPNG.
OPENING
OPP.
OPPOSITE
Fire hydrants shall be installed and made
O.C.
ON CENTER
serviceable prior to and during the time of
P.L.
PLASTIC LAMINATE
construction.
PLAM.
PLASTIC LAMINATE
PR.
PAIR
Fire apparatus access roads shall be installed
PT.
P.T.
PAINT
PRESSURE TREATED
and mace serviceable prior to and during the
PWD.
PLYWOOD
time of construction.
I.F.C. Section 501.4
QT.
QUARRY TILE
RA.
RETURN AIR
RE.
REFERENCE / REFER TO
RD.
REFR.
ROOF DRAIN
REFRIGERATOR
A SEPARATE PERMIT IS
REINF.
REINFORCE (D) (ING)
REQUIRED FOR THE
REQMTS.
REQUIREMENTS
FIRE ALARM SYSTEM
REQ.
REQUIRED
RES.
RESILIENT
RO.
ROUGH OPENING
SCH.
SCHEDULE
A flush mounted Knox box
SC.
SEC.
SOLID CORE
SECTION
shall be installed in an
SHTG.
SHEATHING
approved location. Boxes
pp
SH.
SHELF
SIM.
SIMILAR
can be ordered online at
SPEC.
SPK.
SPECIFICATION
SPEAKER
www.knoxbox.com.
SQ.
SQUARE
SST.
STAINLESS STEEL
STL..
STEEL
STOR.
STORAGE
SUPP.
SUPPLIER
SUSP.
SUSPENDED
City of Federal Way
Building Division
3PED FOR CONSTRUCTION
TVJ
1
DRAWING SYMBOL KEY
D# DOOR NUMBER (SEE DOOR SCHEDULE - SHEET A-6)
WINDOW TAG (SEE WINDOW SCHEDULE - SHEET A-6)
® FINISH TAG (SEE FINISH SCHEDULE)
FIXTURE/EQUIPMENT TAG (SEE FIXTURE AND EQUIPMENT SCHEDULE)
O# SHEET NOTE
REVISION TAG (SEE PROJECT TRACKING)
REVISION CLOUD AWA as ITE11 ON WAWG
WITC7111 BY RIEWsNat
ITEM DENOTEDELEVATION MARK
(ELEVATION OF ITEM)
ETAIL /
# DETAIL REFERENCE TAG
EEr /
�Ne
EraL III
# WALL SECTION REFERENCE TAG
EET #
,,"EET III ETAIL
III
BUILDING SECTION REFERENCE TAGS
#--ELEVATION / #----ELEVATION III
SHEET / ETAIL #
# INTERIOR ELEVATION REFERENCE TAGS
sHEU 111
GENERAL NOTES
1. THESE NOTES SHALL APPLY UNLESS OTHERWISE INDICATED BY DRAWINGS
OR SPECIFICATIONS.
2. ALL WORK INCLUDING CIVIL, MECHANICAL, PLUMBING, & ELECTRICAL SHALL
13E PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE FEDERAL,
STATE, & LOCAL CODE REQUIREMENTS, AND IN ACCORDANCE WITH
ACCEPTED CONSTRUCTION INDUSTRY STANDARDS.
3. OWNER SHALL OBTAIN & PAY FOR BUILDING & SIGN PERMITS. CONTRACTOR
SHALL OBTAIN AND PAY FOR ALL OTHER APPLICABLE PERMITS,
INSPECTIONS AND APPROVALS.
4. PRIOR TO TURNING BUILDING OVER TO OWNER, REPAIR OR REPLACE ALL
MATERIALS, GLASS, OR ASSEMBLIES DAMAGED OR BROKEN DURING
CONSTRUCTION.
5. SMOKE DETECTORS SHALL BE HARDWIRED INTO AN AC ELECTRICAL POWER
SOURCE AND SHALL BE EQUIPPED WITH BATTERY BACK-UP. SMOKE 11
DETECTORS SHALL BE TESTED FOR COMPLIANCE UPON COMPLETION OF
WORK.
6. SEAL ALL PENETRATIONS THRU FLOOR DECK.
7. FRAMER SHALL PROVIDE IN -WALL BLOCKING AS REQUIRED AT TOILET
ACCESSORIES, CABINETS, COUNTERTOPS & ALL AREAS W/ WALL HUNG
ITEMS.
8. FRAMER SHALL PROVIDE 2x- FIRE BLOCKING 0 ALL CONCEALED SPACES
OF ALL STUD WALLS ® CEILING LEVEL AND 0 10' INTERVALS AND
OTHERWISE REQUIRED BY CODE.
9• PROVIDE KNOX-BOX IN ACCORDANCE W/ FIRE DEPARTMENT REQUIREMENTS.
10. ALL CONCRETE SLAB TO BUILDING JOINTS ARE TO BE CAULKED.
DRAWING INDEX
CS-1 COVER SHEET
CIVIL
C-1.0 TITLE SHEET
C-2.0 EXISTING CONDITIONS & DEMOLITION PLAN
C-3.0 SWPPP
C-3.1 SWPPP NOTES
C-3.2 SWPPP DETAILS
C-4.0 SITE PLAN
C-5.0 GRADING PLAN
C-5.1 STORM DETAILS
C-6.0 UTILITY PLAN
C-7.0 CONSTRUCTION DETAILS
C-8.0 PHOTOMETRIC PLAN
L-1 LANDSCAPE PLAN & SCEDULE
L-2 PLANT SCHEDULES, NOTES & DETAILS
ARCHITECTURAL
A-1 LOWER FLOOR PLAN
A-2 UPPER FLOOR PLAN
A-3 EXTERIOR ELEVATIONS
A-3.1 TOWER DETAILS
A-4 BUILDING SECTIONS
A-4.1 BUILDING SECTIONS
A-5 WALL SECTIONS
A-6 DOOR AND WINDOW SCHEDULES AND DETAILS
A-6.1 DOOR AND WINDOW DETAILS
A-7 DETAILS AND INTERIOR ELEVATIONS
A-7.1 INTERIOR ELEVATIONS
A-8 REFLECTED CEILING PLANS
A-9 PIT OPENING DETAILS
A-10 DUMPSTER ENCLOSURE
A-11 EGRESS PLAN
STRUCTURAL
S-1 FOUNDATION PLAN
S-2 FOUNDATION DETAILS
S-3 FLOOR FRAMING PLAN
S-3.1 FLOOR PENETRATION PLAN
S-4 FIRST FLOOR DETAILS
S-5 ROOF FRAMING PLAN
S-5.1 ROOF FRAMING DETAILS
MECHANICAL
M-1 MECHANICAL PLAN
M-2 MECHANICAL DETAILS
PLUMBING
P-1 SANITARY PLAN
P-2 WATER PLAN
P-3 PLUMBING DETAILS
P-4 PROCESS PIPING PLAN
ELECTRICAL
E-1 POWER PLAN
E-2 LIGHTING PLAN A D
E-3 SECURITY PLAN
E-4 PANEL SCHEDULE CITYbfiERAL WAY
E-5 SPECIFICATIONS PUBLIC; DEPARTMENT
ES-1 ELECTRICAL SITE PLAN BY
DATE'
SPECIAL PHOTOGRAPHIC REQ,
THE FOLLOWING IS A UST OF PHOTOGRAPHS THAT SHALL BE TAKEN BY THE
GENERAL CONTRACTOR DURING THE COURSE OF CONSTRUCTION. THESE PHOTOS
SHALL BE TAKEN AT APPROPRIATE INTERVALS AND SHALL BE DELIVERED TO VIOL
CONSTRUCTION REPRESENTATIVES ON A WEEKLY BASIS AND SHALL BE
TRANSMITTED ELECTRONICALLY VIA E-MAIL THE PURPOSE OF THESE
PHOTOGRAPHS IS TO DOCUMENT CONSTRUCTION. DISTRIBUTION AND/OR REVIEW
OF SUCH PHOTOS TO/BY THE OWNER SHALL NOT IN ANY WAY BE MISCONSTRUED
AS ACCEPTANCE OF COMPLETED WORK AND DOES NOT RELIEVE THE CONTRACTOR
OF HIS RESPONSIBILITY TO COMPLY FULLY WITH THE REQUIREMENTS SET FORTH
IN THE CONTRACT DOCUMENTS. FAILURE TO TAKE THESE PHOTOGRAPHS OR
FOLLOW THESE PROCEDURES MAY RESULT IN REMOVAL OF IN -PLACE WORK,
PHOTOGRAPHIC DOCUMENTATION, AND REPLACEMENT OF WORK AT THE SOLE
EXPENSE OF THE GENERAL CONTRACTOR WITHOUT DETRIMENTALLY IMPACTING THE
SCHEDULED DATE FOR COMPLETION.
• OVERALL SITE PHOTOS FROM SEVERAL CONSISTENT VANTAGE POINT
• PHOTOS IN EACH ROOM FROM OPPOSITE SIDES OF EACH ROOM
• DETAILED PHOTOS OF ISSUES TO BE RESOLVED
• DETAILED PHOTOS OF WORK ACCOMPLISHED IN THE PAST WEEK
SPECIFIC DETAIL PHOTOS
• SITE UTILITIES PRIOR TO BACKFIWNG
• ALL DOUBLE CLEANOUTS INCLUDING AREA SHOTS TO INDICATED LOCATIONS
• ALL TRENCHES DURING THE BACKFILL PROCESS
• ALL ASPHALT BASE, BASE COURSE, AND TOP COURSE THICKNESS
• ALL PAVING, FOUNDATION, AND SLAB POURS JUST PRIOR TO CONCRETE
PLACEMENT
• PAVING, FOUNDATION, AND SLAB STEEL PLACEMENT IN VARIOUS LOCATIONS
AROUND THE BUILDING
• UNDER SLAB WATERPROOFING & VAPOR BARRIER INSTALLATIONS
• FOUNDATION WATERPROOFING FROM FOOTING TO TOP OF HOLLOW CORE
PLANKS.
• LIGHT POLE BASES PRIOR TO CONCRETE PLACEMENT INCLUDING STEEL AND
BOLTS
• UNDERGROUND PLUMBING INSIDE THE BUILDING
• SUMP(S) IN PLACE PRIOR TO BACKFILL INCLUDING CONNECTIONS
• BACK FILL PROCESS FOR SUMP(S)
• GLASS INSTALLATION DETAILS AT ALL STAGES INCLUDING
A. FLASHING UNDER SILL RECEPTOR
B. SILL RECEPTOR IN PLACE
C. END DAMS SEALED ON SILL RECEPTOR
D. LAPS (IF REQUIRED) IN SILL RECEPTOR
E. SHIMS, UNDER SILL
F. PROPER JAMB AND HEAD GAPS
• ALL WALLS PRIOR TO SHEETROCK INSTALLATION SHOWING ALL BLOCKING,
PLUMBING, STRUCTURAL CONNECTS AT BOTTOM AND TOP PLATES, WALL
ANCHORS, ELECTRICAL CONDUIT, AND INSULATION AT A MINIMUM.
• RESTROOM PRIOR TO FINISHES TO SHOW WALLBOARD AND TILE BACKER.
• PAINT BUCKETS INDICATING MANUFACTURER AND PAINT TYPE SHOWN ON JOB
SITE,
AREA SUMMARY
LOBE PIT, CHANGING,
iI • • ��
I FI pll I Ili h I ;
I = ICI M
TIE
a 1LAM
EM
STAIR =
54 S.F.
• FIRE AREA OF LOBE PIT: 1,498 S.F. (INSIDE FACE OF EXTERIOR WALLS)
• NET LOWER FLR. AREA: 981 S.F. (OCCUPIABLE SPACE)
• NOTE: PER 2012 ICC COMMENTARY FOR SECTION 903.2.11.1 F (STORIES
WITHOUT OPENINGS) THIS FACILITY WILL NOT REQUIRE A SPRINKLER SYSTEM IN
THE LOWER LEVEL
LUBE PIT
SERVICE BAYS, STORAGE,
TOILET, AND MECHANICAL =
1018 S.F.
:LOSET =8 S.F.
OFFICE = 34 S.F.
STAIR = 54 S.F.
to
11 �
Cr
1 WAITING = 95 S.F. I
• FIRE AREA OF MAIN FLOOR: 1,503 S.F. (INSIDE FACE OF EXTERIOR WALLS)
• NET MAIN FLOOR AREA: 1,147 S.F. (OCCUPIABLE SPACE)
MAIN FLOOR LEVEL
PROJECT DATA,
CODE: 2015 INTERNATIONAL BUILDING CODE INCL APPENDICES E & J
WASHINGTON STATE AMENDMENTS, WAC 51-50 & RCW 19.27 & 70.92
ACCESSIBILITY CODE ICC/ANSI A117.1-2009
2017 NATIONAL ELECTRICAL CODE
WASHINGTON STATE AMENDMENTS, WAC 296-43, 296-45, 296-46B
AND RCW 19.28
2015 INTERNATIONAL MECHANICAL CODE
WASHINGTON STATE AMENDMENTS, WAC 51-52 AND RCW 19.27
2015 INTERNATIONAL ENERGY CONSERVATION CODE
WASHINGTON STATE AMENDMENTS, WAC 51-11R, 51-11C
AND RCW 19.27
2015 WASHINGTON STATE ENERGY CODE
2015 UNIFORM PLUMBING CODE, EXCLUDING CHAPTERS 12 AND 15
WASHINGTON STATE AMENDMENTS, WAC 51-56 AND RCW 19.27
2015 INTERNATIONAL FIRE CODE INCL. APPEND B,C,E,F, AND I
WASHINGTON STATE AMENDMENTS, WAC 51-54A AND RCW 19.27
2015 INTERNATIONAL FUEL AND GAS CODE
OCCUPANCY CLASSIFICATION: S-1 STORAGE
CONSTRUCTION TYPE: V-B
OCCUPANT LOAD LUBE PIT:
STAIR (NET): 54 S.F. / 0 = 0 (NON SIMULTANEOUS USE)
LUBE PIT, CHANGING, 981 S.F. / 300 = 4
BREAKAOCKER (NET):
WALLS, FLOOR TANKS,
FLOOR MOUNTED EQUIPMENT: 633 S.F. / 0 = 0 (NON HABITABLE SPACE)
* LUBE PIT TOTAL (GROSS): 1668 S.F. = 4
OCCUPANT LOAD MAIN FLOOR:
STAIR (NET): 54 S.F. / 0 = 0 (NON SIMULTANEOUS USE)
CLOSET: 8 S.F. / 0 = 0 (NON HABITABLE SPACE)
SERVICE BAYS, 1018 S.F. / 300 = 4
STORAGE, TOILET,
MECHANICAL (NET):
WAITING (NET):
95 S.F. /
15 = 7
OFFICE (NET):
34 S.F. /
100 = 1
WALLS, CHASES, FLOOR
OPENINGS:
459 S.F. /
0 = 0 (NON HABITABLE SPACE)
* MAIN FLOOR TOTAL (GROSS):
1668 S.F.
= 12
* LUBE PIT TOTAL (GROSS):
1668 S.F.
= 4
* TOTAL BUILDING SF (GROSS): 3336 S.F.
* TOTAL BUILDING OCCUPANT LOAD: = 16
* GROSS AREA IS MEASURED FROM OUTSIDE FACE OF EXTERIOR WALLS
STORIES / HEIGHT. ONE STORY WITH BASEMENT (LUBE PIT)
t22'-6" TO RIDGE f 28'-7" TO TOP OF TOWER
FLOOR LOADING: 100 PSF + H15-44 ASHTO TRUCK LOADING OF 6,000 LBS.
FRONT AXLE & 24 000 LBS REAR AXLE 14' 0" P R
- A A T
PROJECT DIRECTORY
OWNER
ARCHITECT
STRUCTURAL ENGINEER
ELECTRICAL ENGINEER
LUBE EQUIP. SUPPLIER
Valvoline Instant Oil Change
Ceso
SMBH Structural Engineering
WHS Engineering
Alemite
100 Valvoline Way
175 Montrose West Ave.
Suite 400 Mike Sugrue
2012 West 25th St. Suite 200
7845 Little Ave.
Lexington, KY 40509
Copley, OH 44321
1166 Dublin Road Suite 200
Cleveland, OH 44113
Charlotte, NC
Bus: (330) 665-0660
Columbus, OH. 43215
Bus: (216) 227-8505
28226
Fax: (888) 208-4826
Bus: (614) 481-9800
Fax:(216)633-7888
Bus:1-800-233-0400
Dir: (614)643-5584
Bus Fax: 1 -704-542-4650
OWNER'S PROJECT MANAGER
CIVIL ENGINEER
MEC�BWGENGINEERENGINEER
LANDSCAPE ARCHITECT
Valvoline Instant Oil Change
Ceso
Cesrr
BEG
Brett Holtegel
3601 Rigby Road, Suite
300 175 MI: _&�=WBAv _Suite4011
Bradley Design Group
100 Valvoline Way
Miamisburg, OH 45342
Copley, OH 4432 :-,
4330 N. Lexington St.
Lexington, KY 40509
Bus: (937) 435-8584
Bus: (330) 665-0666_
Tacoma, WA
Bus: (859) 357-7641
Fax: (937) 435-3307
Fax: (888) 208-4826
Bus:(253)272-4848
Fax: (859) 357-5548
WWW.CE86INC.0
5 MONTROSE WEST AVE., SUITE 400 COPL
PHONE: (330) 6650660 FAX: (888)
C
z
8 CESO, ING
9498 '
W
h w
a w
o
In O
0
N
E
a
rn
m
c
0
N
cc
d
z
UJ Rs,
Q =
0 00
JOrn
O}.Q
I- Q>
Z > >
Q = Q
Z =
_ J
WUQ
Z L L w
Oa LL
0
J
>
-- - BRADY N;,P^C dG
1 STATE OF `, ASS i:I.GTON
Project No.
Scale
Drawn
Checked
Date
DrawnJjue
- EIVE
APR 11 2018
Drawing No.
AS NMED
- D