18-102691 (2)FEDERAL WAY GENERAL SITE DEVELOPMENT NOTES: 1. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO PRE -CONSTRUCTION MEETING. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE FEDERAL WAY REVISED CODE (FWRC), APPLICABLE ORDINANCES, AND THE CITY COUNCIL CONDITIONS OF PROJECT APPROVAL. THESE DOCUMENTS ARE SUPPLEMENTED BY THE MOST RECENT VERSION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION (WSDOT/APWA), THE KING COUNTY ROAD STANDARDS (KCRS), AND THE KING COUNTY SURFACE WATER DESIGN MANUAL (KCSWDM). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL ENGINEER TO CORRECT ANY ERROR, OMISSION, OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THESE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST OR LIABILITY TO THE CITY OF FEDERAL WAY. 3. THE DESIGN ELEMENTS WITHIN THESE PLANS HAVE BEEN REVIEWED ACCORDING TO THE FEDERAL WAY ENGINEERING REVIEW CHECKLIST. SOME ELEMENTS MAY HAVE BEEN OVERLOOKED OR MISSED BY THE CITY ENGINEERING PLAN REVIEWER. ANY VARIANCE FROM ADOPTED STANDARDS IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF FEDERAL WAY, PRIOR TO CONSTRUCTION. 4. APPROVAL OF THIS ROAD, GRADING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION (I.E_ DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICITY, ETC.) 5. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY, A PRECONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF FEDERAL WAY, THE APPLICANT, AND THE APPLICANT'S CONSTRUCTION REPRESENTATIVE. 6. A SIGNED COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 7. ON -SITE CONSTRUCTION NOISE SHALL BE LIMITED AS PER FWRC (SECTION 19.105.040); NORMALLY THIS IS 7:00 TO 8:00 P.M., MONDAY THROUGH FRIDAY, AND 9:00 A.M. TO 8:00 P.M. ON SATURDAYS. 8. RIGHT-OF-WAY CONSTRUCTION IS ALLOWED 8:30 A.M. TO 3:00 P.M. MONDAY THROUGH FRIDAY. WRITTEN AUTHORIZATION TO WORK OUTSIDE OF THESE HOURS MUST BE GRANTED BY THE PUBLIC WORKS DIRECTOR. 9. IT SHALL BE THE APPLICANT'S/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE INITIATING OFF -SITE WORK WITHIN THE ROAD RIGHT-OF-WAY. 10. FRANCHISED UTILITIES OF OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL CITY REQUIREMENTS AND THE REQUIREMENTS OF KCRS CHAPTER 8 ARE SUBMITTED TO THE CITY OF FEDERAL WAY AT LEAST THREE DAYS PRIOR TO CONSTRUCTION. 11. VERTICAL DATUM SHALL BE KCAS OR NGVD-29. 12. GROUNDWATER SYSTEM CONSTRUCTION SHALL BE WITHIN A RIGHT-OF-WAY OR APPROPRIATE DRAINAGE EASEMENTS, BUT NOT UNDERNEATH THE ROADWAY SECTION. ALL GROUNDWATER SYSTEMS MUST BE CONSTRUCTED IN ACCORDANCE WITH THE WSDOT/APWA STANDARD SPECIFICATIONS. 13. A UTILITY TRENCHES RIGHT-OF-WAY U L ENCHES IN THE RI HT F AY SHALL BE BACKFILLED "CR H ROCK A PAT T % E G 0 W LLED 5/8 US ED OC AND COMPACTED 0 95. DENSITY. WHEN TRENCH WIDTH IS 18 INCHES OR LESS, AND IS WITHIN THE TRAVELED WAY, TRENCH WILL BE BACKFILLED WITH CONTROL DENSITY FILL (SELF -COMPACTED FLOWABLE FILL) AS DEFINED BY WSDOT 2-09.3(1)E. THE AGGREGATE WILL BE 3/8-INCH MINUS. 14. ALL ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95% DENSITY IN ACCORDANCE WITH WSDOT 2-06.3. 15. OPEN CUTTING OF EXISTING ROADWAYS IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE PUBLIC WORKS DIRECTOR AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH KCRS 8.03(B) 3. 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AT LEAST ONE FLAGGER FOR EACH LANE OF TRAFFIC AFFECTED. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07.23 TRAFFIC CONTROL, SHALL APPLY. 17. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REGULATORY AND WARNING SIGNS PER THE LATEST EDITION OF MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. 18. ALL UTILITIES SHALL BE ADJUSTED TO FINAL GRADE AFTER PAVING ASPHALT WEARING COURSE. 19. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION ONLY. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH CFW DRAWING NUMBERS 3-22, 3-23. ROCKERIES MAY NOT EXCEED SIX FEET IN HEIGHT FOR CUT SECTIONS OR FOUR FEET IN HEIGHT FOR FILL SECTIONS UNLESS DESIGNED BY A GEOTECHNICAL OR STRUCTURAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. COVER SHEET JACKSONS FOOD STORE #636 -FEDERAL WA Y, WA NE 1/4 OF SE 1/4 OF SEC. 20, TWN. 21 N, RGf. 4E, W.M. KING COUNTY WASHINGTON I BCE GENERAL SITE DEVELOPMENT NOTES: 1. THE CONTRACTOR SHALL OBTAIN AND HAVE AVAILABLE COPIES OF THE APPLICABLE GOVERNING AGENCY STANDARDS AT THE JOB SITE DURING THE RELATED CONSTRUCTION OPERATIONS. 2. CONTRACTOR SHALL ASSURE THAT ALL NECESSARY PERMITS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION WHETH ER ER SHOWN ON THESE PLANS OR NOT. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST ON THIS SITE. ONLY THOSE UTIL ITIES WITH EVIDENCE OF THEIR INSTALLATION VISIBLE AT GROUND SURFACE OR SHOWN ON RECORD DRAWING PROVIDED BY OTHERS ARE SHOWN HEREON. EXISTING UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY AND ARE SUBJECT TO A DEGREE OF UNKNOWN VARIATION. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY HAVE BEEN TAKEN FROM PUBLIC RECORDS. BARGHAUSEN CONSULTING ENGINEERS, INC. ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC RECORDS OR RECORDS OF OTHERS, IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC., TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO THE SPECIFICATIONS OR THE RELATIVE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF WORK AS DEFINED BY THE DRAWINGS AND IN FULL COMPLIANCE WITH LOCAL REGULATIONS AND CODES. 5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE APPROPRIATE UTILITIES INVOLVED PRIOR TO CONSTRUCTION. 6. INSPECTION OF SITE WORK WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE GOVERNING JURISDICTION. INSPECTION OF PRIVATE FACILITIES WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE OWNER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 7. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY THE CONTRACTOR SHALL CONTACT THE AGENCY AND/OR UTILITY INSPECTION PERSONNEL AND ARRANGE ANY REQUIRED PRE -CONSTRUCTION MEETING(S). CONTRACTOR SHALL PROVIDE ONE WEEK MIN. ADVANCE NOTIFICATION TO OWNER, FIELD ENGINEER AND ENGINEER OF PRE -CONSTRUCTION MEETINGS. 8. THE CONTRACTOR IS RESPONSIBLE FOR WORKER AND SITE SAFETY AND SHALL COMPLY WITH THE LATEST OSHA STANDARDS AND REGULATIONS, OR ANY OTHER AGENCY HAVING JURISDICTION FOR EXCAVATION AND TRENCHING PROCEDURES. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE "MEANS AND METHODS" REQUIRED TO MEET THE INTENT AND PERFORMANCE CRITERIA OF OSHA, AS WELL AS ANY OTHER ENTITY THAT HAS JURISDICTION FOR EXCAVATION AND/OR TRENCHING PROCEDURES. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AT LEAST ONE FLAGGER FOR EACH LANE OF TRAFFIC AFFECTED. 10. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ALL ADJACENT PUBLIC AND PRIVATE PROPERTIES AT ALL TIMES DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL EXISTING UTILITY SERVICES THAT ARE TO REMAIN OPERATIONAL WITHIN THE CONSTRUCTION AREA WHETHER SHOWN OR NOT SHOWN ON THE PLANS. 11. TWO (2) COPIES OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. ONE (1) SET WITH RECORDS OF AS -BUILT INFORMATION SHALL BE SUBMITTED TO BARGHAUSEN CONSULTING ENGINEERS, INC. AT COMPLETION OF PROJECT. 12. CONTRACTOR SHALL OBTAIN SERVICES OF A LICENSED LAND SURVEYOR TO STAKE HORIZONTAL CONTROL FOR ALL NEW IMPROVEMENTS. STAKING CONTROL SHALL BE TAKEN FROM ELECTRONIC PLAN FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS INC.. 13. CONTRACTOR SHALL REQUEST FROM BARGHAUSEN CONSULTING ENGINEERS INC., PRIOR TO ANY CONSTRUCTION STAKING OR CONSTRUCTION WORK, A FORMAL CONSTRUCTION RELEASE PLAN SET OR SPECIFIC RELEASE IN WRITING. THE APPROVED AGENCY PERMIT DRAWINGS WILL NOT BE CONSIDERED CONSTRUCTION RELEASE PLANS BY BARGHAUSEN CONSULTING ENGINEERS, INC. UNLESS BARGHAUSEN CONSULTING ENGINEERS, INC. HAS GIVEN A FORMAL WRITTEN RELEASE OR ISSUED A CONSTRUCTION RELEASE PLAN SET. LEGEND: �i 0 , I r -� ° N88'39'091N 97,/o 4 • r? ,a.pgp�yC STQRE vv FF-279M i N88'3V09'W 277.86' I i a e ° ai,° ° a a G ° $ • I00 NEV 3AN SF CANOPY s NEW U81'8 I OVER 6 MPID'8 i I I4i ° a e , a° 4 y10 a a a I a 150.10' 4. a a a: 0 N88'39� - -_ -`- __- _ 348TH ST OWNER GEOTECHNICAL ENGINEER PACWEST ENERGY, LLC GEOTECH CUNSULTANTS, LLC 3450 E. COMMERCIAL CT. 2401 10TH AVENUE EAST MERIDIAN, ID 83642 SEATTLE WA, 98102 TEL: (208) 888-3585 TEL: (425) 747-5618 CONTACT: JACK DAVIS CONTACT: MARC MCGINNIS, P.E. MECHANICAL/ELECTRICAL/ PLUMBING ENGINEER ABOSSEIN ENGINEERING 1844 144TH AVE NE BELLEVUE WA, 98004 TEL: (425) 462-9441 CONTACT: GARY WOMACK, P.E PROPOSE EXISTIN SOILS REPORT NOTES: BARRIER CURB CURB 1. THE FOLLOWING SOILS REPORT FOR THE SITE SHALL BE CONSIDERED PART OF THESE --- -- CONCRETE PAINT STRIPE CONSTRUCTION DOCUMENTS: GEOTECHNICAL ENGINEERING REPORT: __ CONCRETEE. o== PROPOSED RECONSTRUCED CONVENIENCE STORE STAMPED CONCRETE 1520 SOUTH 348TH STREET & 34713 - 16TH AVENUE SOUTH CONTOUR --420-- (STORE #363) PARKING CONCRETE WATER _W_ -w- _W_ FEDERAL WAY, WA DATED JUNE 1, 2017 STORM DRAIN - - SO- _ - SOIL INVESTIGATION AS PERFORMED BY: ASPHALT R GEOTECH CONSULTANTS, INC. TYPE 1 CATCH BASIN ❑ 2401 10TH AVENUE E PAVEMENT SWALE ... SEATTLE, WA 98102 SAWCUT------------- SANITARY 'S HBEETHE SS MANHOLE 0 2. IT SHALL RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL PROVISIONS OF CONTOUR --- +118----- THE SOILS REPORT FOR THE SITE BE OBSERVED AND COMPLIED WITH DURING ALL PHASES OF WATER W GAS -------- G---- -- --- THE SITE PREPARATION, GRADING OPERATIONS, FOUNDATION, SLAB, AND PAVING CONSTRUCTION. WATER METER ® POWER - P (OH)--- - 3. ANY PROVISIONS OF THE SOILS REPORT WHICH CONFLICT WITH INFORMATION SHOWN ELSEWHERE STORM DRAIN (SD) ON THESE DRAWINGS, OR WHICH REQUIRE FURTHER CLARIFICATION, SHALL BE BROUGHT TO THE TREE ATTENTION OF BARGHAUSEN CONSULTING ENGINEERS, INC. SANITARY SEWER (SS) EX RETAINING WALL 4. A REPRESENTATIVE OF THE SOILS ENGINEER SHALL BE AVAILABLE TO OBSERVE AND APPROVE THE GAS G SPOT ELEVATION 340.83� EARTHWORK OPERATIONS AND TO VERIFY FIELD CONDITIONS AS WORK PROCEEDS. THE SOILS ENGINEER SHALL SUBMIT FIELD REPORTS DOCUMENTING THAT THE METHODS AND MATERIALS OF POWER p STREET LIGHT THE EARTHWORK OPERATIONS WERE IN ACCORDANCE WITH THE RECOMMENDATION OF THE SOILS TYPE 1 CATCH BASIN METER (B INVESTIGATION AND THAT THE WORK WAS PERFORMED TO THE SATISFACTION OF THE ENGINEER. THE CONTRACTOR SHALL MAKE ALL PROVISIONS FOR SOILS INSPECTIONS AS RECOMMENDED TYPE 2 CATCH BASIN ® WITHIN THE SOILS REPORT. AT A MINIMUM, THIS INCLUDES THE OBERVADON OF THE FOLLOWING SANITARY SEWER CLEANOUT • BY A SOILS ENGINEER: A. OVER -EXCAVATION RECOMMENDATIONS SLOPE ARROW 2.0% B. PLACEMENT OF STRUCTURAL FILL MATERIAL BENEATH PAVEMENT SPOT ELEVATION jjL12 C. SUBGRADE PREPARATION OF CANOPY FOOTINGS 5. THE CONTRACTOR SHALL QUALIFY ANY LIMITATIONS TO SOILS INSPECTIONS WITHIN BID PROPOSAL. R/W LIGHTING �+11 TRAFFIC ENGINEER TRANSPORTATION ENGINEERING NORTHWEST 11400 SE 8TH STREET SUITE 200 BELLEVUE WA, 98004 TEL: (425) 250-0868 CONTACT: CHRISTOPHER BICKET, P.E. LEGAL DESCRITPIONS: (PER FIRST AMERICAN TITLE INSURANCE COMPANY'S REPORT NUMBER 2, FILE NO. NCS-809029-WA1, DATED OCTOBER 28, 2016 AT 7:30 A.M.) PARCEL 1: (TAX LOT 889700-0095-05) LOT 19 OF VICK ADDITION, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 45 OF PLATS, PAGE 27, IN KING COUNTY, WASHINGTON. EXCEPT THE EAST 20 FEET THEREOF CONVEYED TO KING COUNTY BY DEED RECORDED JANUARY 18, 1977 AS RECORDING NO. 7701180056. LJ a F- ENGINEER/LANDSCAPE/ ARCHITECT/SURVEYOR BARGHAUSEN CONSULTING ENGINEERS, INC. 18215 72ND AVE. SOUTH KENT, WA 98032 TEL: (425) 251-6222 FAX: (425) 251-8782 CONTACT: CHRIS JENSEN, P.E./JEFF VARLEY, R.L.A./DAN GOALWIN, R.A./ OWEN B. HILLE, P.L.S. S 344TH ST }N r N 4 QP Z S 34M1 PL S 348TH 51 6N �gWS G S 352ND ST -®- V" SHEET INDEX: CIVIL C1.0 - COVER SHEET CIA - ITI COND ONS OF APPROVAL VL C2.0 - EXISTING CONDITIONS MAP C3.0 - TESC AND DEMOLITION PLAN C3.1 - TESC NOTES AND DETAILS C4.0 - SITE PLAN C5.0 - HORIZONTAL CONTROL PLAN C6.0 - GRADING PLAN C7.0 - DRAINAGE PLAN C7.1 - DRAINAGE DETAILS C7.2 - DRAINAGE DETAILS C8.0 - UTILITY PLAN C8.1 - UTILITY DETAILS C8.2 - UTILITY DETAILS C8.3 - UTILITY DETAILS C9.0 - SITE CROSS SECTION PLAN C10.0 - 16TH AVENUE PLAN AND PROFILE C10.1 - S 348TH ST PLAN AND PROFILE C10.2 - CHANNELIZATION PLAN C10.3 - FEDERAL WAY STANDARD DETAILS C10.4 - FEDERAL WAY STANDARD DETAILS C11.0 - CONSTRUCTION NOTES AND DETAILS C11.1 - CONSTRUCTION NOTES AND DETAILS C11.2 - CONSTRUCTION NOTES AND DETAILS C11.3 - CONSTRUCTION NOTES AND DETAILS LANDSCAPE L1 - TREE RETENTION AND LANDSCAPE PLAN L2 - LANDSCAPE NOTES AND DETAILS L3 - IRRIGATION PLAN L4 - IRRIGATION NOTES AND DETAILS TRAFFIC TS1.01 - TRAFFIC SIGNAL AND ILLUMINATION PLAN TS1.02 - TRAFFIC SIGNAL WIRE DIAGRAM TS1.03 - TRAFFIC SIGNAL AND ILLUMINATION TS1.04 - ATS RED LIGHT CAMERA DETAILS PHOTOMETRIC CALCULATIONS FILE EXH 1428 '^ co 0 W 0) Z W W � oco 00 z z ® O 0 w N N U o U U Ln w w a m a cr m a r a it U U (N N V1 Y M I - a ro ao \ \ N - 0 N \ \ N N N ALL SURVEY MONUMENTS, BENCHMARKS, LOT CORNERS AND SURVEY CONTROL POINTS MUST BE PROTECTED IN PLACE. IF ANY SURVEY MONUMENTS ARE DESTROYED OR DAMAGED, THEY MUST BE REPLACED BY A LICENSED LAND SURVEYOR AT THE CONTRACTOR'S COST AND A LOT CORNER RECORD FILED WITH THE COUNTY SURVEYOR. SITE DATA: ADDRESS- ADDRESS: 1520 S 348TH STREET CITY OF FEDERAL WAY PUBLIC WORKS INSPECTION PHONE: (253) 835-2700 OWNER: APN- PROPERTY AREA: DISTURBED AREA: FEDERAL WAY, WA 98003 JACKSONS FOOD STORES 3450 EAST COMMERCIAL COURT MERIDIAN, ID 83642 889700-0095 AND 889700-0115 45,698 (1.05 AC) 55,900 (1.28 AC) CONTRACTOR SHALL HAVE ALL PROPERTY LINES, CURB, SIDEWALK, STRUCTURES, CONCRETE PADS AND ANY OTHER ABOVE GROUND PERMANENT STRUCTURE DEPICTED ON THESE PLANS STAKED FOR CONSTRUCTION BY A LICENSED SURVEYOR. LICENSED SURVEYOR SHALL STAKE ALL ITEMS USING COORDINATE GEOMETRY (RECTIFIED TO SITE CONTROL) CONTAINED IN CAD DRAWING FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. IT IS THE CONTRACTORS RESPONSIBILITY TO RETRIEVE LATEST CAD FILES FROM BARGHAUSEN CONSULTING ENGINEERS REFLECTING ANY ISSUED PLAN REVISIONS. BARGHAUSEN CONSULTING ENGINEERS SHALL IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. IMPERVIOUS AREA- ROOF - 9,208 S.F. - 24,621 S.F. LMLP C��ICT NOTE: PERVIOUS AREA: EST. EARTHWORK OUANTITIES: CONCRETE TOTAL - 33,829 S.F. TOTAL - 8.100 S.F. CUT: 2,700 CY FILL: 3,300 CY NET: 600 CY (FILL) THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 'CONTRACTOR SHALL REFER TO THE REPORT OF GEOTECHNICAL INVESTIGATION FOR THIS SITE PREPARED BY ASSOCIATED EARTH SCIENCES, INC. FOR INSPECTION LINE FEDERAL WAY PUBLIC WORKS DEPARTMENT PRECONSTRUCTION/INSPECTION NOTIFICATION NUMBER (253)835-2700. 0 PERMIT N �. 8 - Q 2 9 -00-CO GRADING RECOMMENDATIONS. EARTHWORK QUANTITIES ARE APPROXIMATE. CONTRACTOR TO VERIFY EARTHWORK QUANTITIES PRIOR TO CONSTRUCTION. PARKING REQUIRED: 13 STALLS 0 PARKING PROVIDED: ON -SITE = 18 STALLS PROVIDED (1 ADA STALL) TOTAL = 18 STALLS PROVIDED Know what's below. FLOOD ZONE- FLOOD ZONE X-SHADED ACCORDING TO FIRM NO. Call before you dig. 12P41RI1VF1 53033C125OF AS PUBLISHED BY FEMA ON MARCH 16. 1995. Dial811 (1-800-424-5555) �//9 DATE CV . co 00 00 Q cn 00 _ � LLI 00 00 L� CR oo N O ��® VJ U ® r L U 0 ::D n Y ® _j Q co P _ + U MMM 00 ry- CO ® Lu Co N U Q Q w �C:) ,n I:zt co 47671 ''VS1E' VA_L .-a 12/19 1 O M E Q U N a z �0 > x N M a m a m o ,. d Y O 0 ,0)LJ = ,n U U I- z y O (101n zw Li - Z x `= o� Z w W N g Q O CN N ONO Z Z OD (7) N Cfl OO of w Z N Q I I Zw Ln Ln LO 0 Z W> �,, L0 L0 00 UJ Z N N � O Y v v (U in a �c c = z w vt A a E D z m 0 61