20-103093-SITE PLAN67 A 0 C C E PUGET / SOUND _40- AO- - / i t n ,_.. I r01 n 5-0 5-0 SIDE YARD + SIDE YA RD SETBACK //i' SETBACK 140 SITE PLAN Scale: 1"=20'-0" 0 10' 20' F � LEGAL DESCRIPTION E 60 FT OF W 580.77 FT OF GL 4 LESS S 40 FT FOR RD (t NORTH NELSON RESIOENC ALTERATIONS AND REMODEL OF AN EXISTING SINGLE WSEC ALTERATION WORKSHEET 2015 STATE ENERGY CODE THE WASHINGTON STATE ENERGY CODE REQUIREMENTS FOR ALTERATIONS ARE LOCATED IN CHAPTER 5 ALTERATIONS (REMODELS) DO NOT NEED TO OBTAIN ENERGY CREDITS FROM TABLE R 406.2. ADDITIONS MEET THE REQUIREMENTS FOR NEW CONSTRUCTION. THIS INCLUDES NON-COMMISSIONED SPACE BEING ALTERED TO BECOME CONDITIONED SPACE. WILL THE WALL CAVITIES BE EXPOSED? IF YES: EXPOSED WALL CAVITIES MUST BE INSULATED. * 2 X 4 WALLS REQUIRE R-15 INSULATION. *2 X 6 WALLS REQUIRE R-21 INSULATION WILL THE ROOF/CEILING FRAMING CAVITIES OR ATTIC BE EXPOSED? IF YES: EXPOSED ROOF/ASSEMBLIES MUST BE INSULATED * VAULTED CEILINGS: INSULATE TO FULL DEPTH OF THE FRAMING MEMBER WHILE ALLOWING FOR THE MINIMUM 1" VENTILATED SPACE. *FLAT CEILINGS: INSTALL R-49 INSULATION OR WHAT THE ATTIC SPACE CAN ACCOMMODATE BASED ON THE ROOF PITCH. WILL THE FLOOR FRAMING CAVITIES BE EXPOSED? IF YES: EXPOSED FLOOR CAVITIES MUST BE INSULATED TO R-30 WILL THE WINDOWS AND/OR DOORS BEING REPLACED? (INCLUDES BOTH WINDOW AND DOOR FRAMES). IF YES: NEW WINDOWS AND DOORS MUST HAVE AN AREA WEIGHTED AVERAGE U-FACTOR OF < 0.30 WILL THE COOLING SYSTEM BE REPLACED? IF YES: NEW EQUIPMENT MUST MEET CURRENT REQUIREMENTS AND DUCTS NEED TO BE TESTED. WILL THE HOT WATER SYSTEM BE ALTERED? IF YES: NEW WATER HEATING EQUIPMENT MUST MEET CURRENT CODE REQUIREMENTS. ARE MORE THAN 50% OF THE LIGHT FIXTURES BEING CHANGED? IF YES: 75% OF ALL LAMPS MUST BE HIGH EFFICACY (LED OR CFL) R503.1.1 BUILDING ENVELOPE: BUILDING ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R402.1.1 OR R402.1.4, SECTIONS R402.2.1 THROUGH R402.2.11, R302.3.1, R402.3.2, R402.4.3, AND R402.4.4. EXCEPTION: THE FOLLOWING ALTERATIONS NEED NOT COMPLY WITH THE REQUIREMENTS FOR NEW CONSTRUCTION PROVIDED THE ENERGY USE OF THE BUILDING IS NOT INCREASED: 1. STORM WINDOWS INSTALLED OVER EXISTING FENESTRATION. 2. EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THAT THESE CAVITIES ARE FILLED WITH INSULATION. 2 X 4 WALLS SHALL BE INSULATED TO A MINIMUM OF R-15 AND 2 X 6 WALLS SHALL BE INSULATED TO A MINIMUM OF R-21. 3. CONSTRUCTION WHERE THE EXISTING ROOF, WALL OR FLOOR CAVITY IS NOT EXPOSED. 4. ROOF RECOVER. 5. ROOFS WITHOUT INSULATION IN THE CAVITY AND WHERE THE SHEATHING OR INSULATION IS EXPOSED DURING RE -ROOFING SHALL BE INSULATED EITHER ABOVE OR BELOW THE SHEATHING. 6. SURFACE -APPLIED WINDOW FILM INSTALLED ON EXISTING SINGLE PANE FENESTRATION ASSEMBLIES TO REDUCE SOLAR HEAT GAIN PROVIDED THE CODE DOES NOT REQUIRE THE GLAZING FENESTRATION TO BE REPLACED. R503.1.1.1 REPLACEMENT FENESTRATION. WHERE SOME OR ALL OF AN EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW FENESTRATION PRODUCT, INCLUDING SASH AND GLAZING, THE REPLACEMENT FENESTRATION UNIT SHALL MEET THE APPLICABLE REQUIREMENTS FOR U-FACTOR AND SHGC IN TABLE R402.1. R502.1.1.2 HEATING AND COOLING SYSTEMS. NEW HEATING, COOLING AND DUCT SYSTEMS THAT ARE PART OF THE ADDITION SHALL COMPLY WITH SECTION R403.1, R403.2, R403.3, R403.5 AND R403.6. EXCEPTION. THE FOLLOWING NEED NOT COMPLY WITH THE TESTING REQUIREMENTS OF SECTION R403.3.3.: 1. ADDITIONS OF LESS THAN 750 SQUARE FEET. 2. DUCT SYSTEMS THAT ARE DOCUMENTED TO HAVE PREVIOUSLY SEALED AS CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING IN ACCORDANCE WITH PROCEDURES IN WSU RS-33. 3. DUCTS WITH LESS THAN 40 FEET IN UNCONDITIONED SPACES. 4. EXISTING DUCT SYSTEMS CONSTRUCTED, INSULATED OR SEALED WITH ASBESTOS. R503.1.3 SERVICE HOT WATER SYSTEMS. NEW SERVICE HOT WATER SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R403.4. R503.1.4 LIGHTING. NEW LIGHTING SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R404.1 EXCEPTION: ALTERATIONS THAT REPLACE LESS THAN 50 PERCENT OF THE LUMINARIES IN SPACE, PROVIDED THAT SUCH ALTERATIONS DO NOT INCREASE THE INSTALLED INTERIOR LIGHTING POWER. R503.2 CHANGE IN SPACE CONDITIONING. ANY NON -CONDITIONED OR LOW -ENERGY SPACE THAT IS ALTERED TO BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE BROUGHT INTO FULL COMPLIANCE WITH THIS CODE. VICINITY MAP Go gle Maps 1408 SW 296th St F �.i:•:irk P��k / PROJECT SITE _ •1408 S."I"" s, �9hths,rPP, Federal Way Dash Po t Dash Point State Park Go gle Map data 02020 2000 h CITY OF FEDERAL WAY N 1408 Southwest 296th Street SW 296th St SW 296th St 0 Q 1 1 2 3 1 4 E R MOD FAMILY RESIDENCE STAIRWAY NOTES IRC R311.7.1 WIDTH: STAIRWAY SHALL NOT BE LESS THAN 36 INCHES IRC R311.7.2 HEADROOM: STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCE OF 80 INCHES MEASURED VERTICALLY FROM A LINE CONNECTING THE EDGE OF THE NOSINGS. IRC R311.7.5.1 RISERS: THE MAXIMUM RISER HEIGHT SHALL BE 7.75 INCHES. THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH. IRC R311.7.5.2 TREADS: THE MINIMUM TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES. THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PORTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY 3/8 INCH. IRC R311.7.5.3 NOSINGS: THE RADIUS OF CURVATURE OF THE NOSING SHALL BE NOT GREATER THAN 9/16 INCH. A NOSING NOT LESS THAN 3/4 INCH BUT NOT MORE THAN 1-1/4 INCH SHALL BE PROVIDED ON THE STAIRWAYS WITH SOLID RISERS. THE GREATEST RISER NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST NOSING PROJECTION BY MORE THAN 3/8 INCH BETWEEN TWO STORIES, INCLUDING THE NOSING AT THE LEVEL OF FLOORS AND LANDINGS. BEVELING OF NOSING SHALL NOT EXCEED 1/2 INCH. RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE LANDING EDGE OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES FROM THE VERTICAL. OPEN RISERS ARE PERMITTED PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT PERMIT THE PASSAGE OF A 4 INCH DIAMETER SPHERE. (EXCEPTIONS: A NOSING IS NOT REQUIRED WHERE THE TREAD DEPTH IS A MINIMUM OF 11 INCHES.) IRC R311.7.6 LANDINGS FOR STAIRWAYS: THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. THE WIDTH PERPENDICULAR TO THE DIRECTION OF TRAVEL SHALL BE NOT LESS THAN THE WIDTH OF THE FLIGHT SERVED.... WHERE THE STAIRWAY HAS A STRAIGHT RUN, THE DEPTH IN DIRECTION OF TRAVEL SHALL NOT BE LESS THAN 36 INCHES. R311.7.9 ILLUMINATION STAIRWAYS SHALL BE PROVIDED WITH ILLUMINATION IN ACCORDANCE WITH R303.7 HANDRAIL NOTES IRC 311.7.8 HANDRAILS: SHALL BE PROVIDED ON AT LEAST ON SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR MORE RISERS. IRC R311.7.8.1 HEIGHT: HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS, SHALL BE UNIFORM, NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES. IRC R311.7.8.2 CONTINUITY: HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POST OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1.5 INCHES BETWEEN THE WALL AND THE HANDRAILS. IRC R311.7.8.3 GRIP SIZE: HANDRAILS WITH A CIRCULAR CROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST 1.25 INCHES AND NOT GREATER THAN 2 INCHES. IF THE HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4 INCHES AND NOT GREATER THAN 6.25 INCHES WITH A MAXIMUM CROSS-SECTION DIMENSION OF 2.25 INCHES. EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01 INCH. GUARDRAIL NOTES IRC R312.1.1 WHERE REQUIRED: GUARDS SHALL BE LOCATED ALONG OPEN -SIDED WALKING SURFACES INCLUDING STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. IRC R312.1.2 HEIGHT: REQUIRED GUARDS AT OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 36 INCHES IN HEIGHT MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACES OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS. EXCEPTIONS: GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT NOT LESS THAN 34 INCHES MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. IRC R312.1.3 OPENING LIMITATIONS: REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE4 WALKING SURFACE TO THE REQUIRED GUARD HEIGHT THAT ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER. EXCEPTIONS: 1.) THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF A STAIR FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES IN DIAMETER. ECEPTIONS: 2) GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE OF 4 e INCHES IN DIAMETER. STAIR ILLUMINATION IRC R303.7 INTERIOR STAIRWAY ILLUMINATION: INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS TO LEVELS OF NOT LESS THAN 1 FOOT-CANDLE AS MEASURED AT THE CENTER OF THE TREADS AND LANDINGS. THERE SHALL BE A SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. IRC R303.8 EXTERIOR STAIRWAY ILLUMINATION: EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. SMOKE ALARMS IRC R314 SMOKE ALARMS SHALL BE PROVIDED IN ACCORDANCE TO SECTION R314. CARBON MONOXIDE ALARMS IRC R315 CARBON MONOXIDE ALARMS SHALL BE PROVIDED ACCORDANCE TO SECTION R315. E L GENERAL NOTES PROJECT INFORMATION: 1. BY THE ACT OF SUBMITTING A BID FOR THIS PROJECT, THE PROPERTY OWNERS: SUSAN NELSON CONTRACTOR WARRANTS THAT HE/SHE HAS CAREFULLY 1408 SW 296TH ST . EXAMINED THE SITE AND EXISTING CONDITIONS AND HAS FEDERAL WAY, WA, 98023 SATISFIED HIMSELF/HERSELF AS TO THE NATURE OF THE WORK, T: (253) 941-0628 CHARACTER, QUALITIES, QUANTITIES OF MATERIALS AND ANY DIFFICULTIES THAT MAY BE ENCOUNTERED DURING THE PROCESS PROJECT ADDRESS: 1408 SW 296TH ST 98023 OF CONSTRUCTION WHICH MAY IN ANY WAY AFFECT THE FEDERAL WAY, WA, 98023 PERFORMANCE OF THE WORK. TAX PARCEL NO.: 062104-9036 2. DO NOT SCALE DRAWINGS, CONTRACTOR TO USE DIMENSIONS SHOWN. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND LEGAL DESCRIPTION: E 60 FT OF W 580.77 OF GL 4 LESS S 40 FT FOR RD DIMENSIONS AND SHALL NOTIFY ARCHITECT OF ANY YEAR BUILT.: 1948 DISCREPANCIES FOUND IN THE FIELD. IF ANY ERRORS, OMISSIONS OR INCONSISTENCIES APPEAR IN THE DRAWINGS, SPECIFICATIONS LOT SIZE.: 24,355 SF OR OTHER DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF SUCH ERRORS, OMISSIONS OR PROPOSED SQ FT.: MAIN FLOOR AREA = 2,065 SF INCONSISTENCIES BEFORE PROCEEDING WITH THE WORK. BASEMENT AREA = 875 SF 3. COORDINATE ALL BUILDING CONSTRUCTION WITH OWNER, INCLUDING TOTAL LIVING AREA = 2940 SF MATERIALS STORAGE, GARBAGE DISPOSAL, WORK HOURS, DISRUPTIONS TO POWER, WATER AND LIFE SAFETY SYSTEMS TO ATTACHED GARAGE = 285 SF ENSURE THE SAFETY OF THE STRUCTURE 4. THE APPROVED PLANS SHALL NOT BE CHANGED OR ALTERED WITHOUT COVERED PORCH= 53 SF AUTHORIZATION FROM THE BUILDING OFFICIAL. THE APPROVED COVERED DECK- 173 SF PLANS ARE REQUIRED TO BE ON THE JOBSITE. UNCOVERED DECK- 73 SF 5. ALL WORK SHALL MEET LOCAL CODES AND ORDINANCES. 6. ALL DOORS NOT DIMENSIONED SHALL BE LOCATED 5" FROM FACE OF STUD OR MASONRY WALL TO EDGE OF ROUGH OPENING. 7. SEE STRUCTURAL NOTES FOR INFORMATION RELATING TO FRAMING, ZONING NAILING AND OTHER STRUCTURAL INFORMATION 8. JOB SITE ADDRESS TO BE POSTED DURING CONSTRUCTION AND CITY OF FEDERAL WAY MUNICIPAL CODE PERMANENT ADDRESS NUMBERS TO BE PROVIDED FOR FINAL TITLE 19 ZONING AND DEVELOPMENT CODE INSPECTION PER R321.1 9. COMPLIANCE CARD TO BE POSTED VERIFYING INSULATION INSTALLED ZONING: RS15.0 SINGLE FAMILY (RESIDENTIAL USE ZONE) IN WALLS, CEILING AND FLOORS 10. PROVIDE METAL NAIL STOPPERS TO PROTECT PLUMBING AND WIRING MINIMUM LOT AREA: 15,000 SF FROM DAMAGE BY NAILS. MAXIMUM HEIGHT LIMIT: 30 FT 11. MAINTAIN 3" CLEAR (MIN.) BETWEEN CEILING FIXTURES AND INSULATION MINIMUM LOT SIZE: 15,000 SF UNLESS FIXTURE IS RATED FOR CONTACT WITH INSULATION FRONT YARD SETBACK: 20 FT 12. WATER PIPES SHALL BE INSULATED TO R-8 IN UNHEATED SPACES. SIDE YARD SETBACK: 5 FT 13. METAL DUCTS TO BE INSULATED AND JOINTS TO BE TAPED. ALL REAR YARD SETBACK: 5 FT EXPOSED DUCTS IN GARAGE TO BE 26GA WITH NO OPENINGS AND MAX LOT COVERAGE: 50% SEALED WITH APPROVED MATERIAL. REQUIRED PARKING: 2 PER DWELLING UNIT 14. ANY BATT INSULATION WITH CRAFTFACE SHALL HAVE ALL TEARS AND JOINTS IN VAPOR RETARDER SEALED WITH TAPE. CONSTRUCTION TYPE: TYPE V-N 15. ALL OPENINGS TO BE CAULKED, SEALED OR WEATHER STRIPPED. PROJECT DESCRIPTION: SINGLE FAMILY RESIDENCE REMODEL 16. SHOWERS SHALL BE FLOW CONTROLLED TO 2.5 GPM AT 80 PSI AND MIXING VALVES SHALL COMPLY WITH ASSE 1016 NOTE: MECHANICAL AND ELECTRICAL TO BE SUBMITTED 17. ALL BATHROOM, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS UNDER SEPARATE PERMIT AND SIMILAR ROOMS SHALL BE PROVIDED WITH NATURAL LIGHT AND VENTILATION BY MEANS OF OPERABLE EXTERIOR OPENINGS PROJECT TEAM WITH A GLAZING AREA OF NOT LESS THAN 3 S.F. ONE HALF OF WHICH MUST BE OPERABLE. IF AN OPERABLE WINDOW IS NOT PROVIDED, MECHANICAL VENTILATION SHALL BE PROVIDED, ARCHITECT: DAVID POOL ARCHITECTURE PLLC CONNECTED DIRECTLY TO THE OUTSIDE, CAPABLE OF PROVIDING DAVID POOL, AIA 6716 EAST SIDE DR NE, STE 1 - PMB 500 AN EXHAUST RATE OF 50CFM IF INTERMITTENT, AND 25 CFM IF TACOMA, WA 98422 CONTINUOUS EXHAUST IS PROVIDED. T. 253.651.4077 18. KITCHEN AND BATHROOM EXHAUST SHALL BE VENTED TO THE OUTSIDE E. DPOOL@DAVIDPOOLARCHITECTURE.COM UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. DOMESTIC CLOTHES DRYERS SHALL BE EXHAUSTED TO THE STRUCTURAL ENGINEER: SWENSEN SAY FAGET 1 OUTSIDE IF IN AN AREA THAT IS HABITABLE OR CONTAINING OTHER STRUCTURAL ENGINEERS FUEL -BURNING APPLIANCES. KITCHEN VENTILATION SHALL BE 6121 BAYVIEW DR NE TACOMA, WA, 98422 PROVIDED AT THE RATE OF 100CFM IF INTERMITTENT AND 20CFM IF CONTINUOUS EXHAUST IS PROVIDED. PRINCIPAL IN CHARGE: RYAN M. REICHMAN, PE 19. HOT WATER HEATER SHALL MEET THE REQUIREMENTS OF THE IRC, PROJECT MANAGER: BETH BROWN, PE 0. 0 CHAPTER 28. D. 253-8 8.4971 20. PROVIDE AN INTERCONNECTED SMOKE ALARM SYSTEM PER IRC R313 POWERED BY 110V AC WITH BATTERY BACKUP. SMOKE ALARMS ARE TO BE INSTALLED ON EACH SEPARATE FLOOR OF THE GENERAL CONTRACTOR: JB McHUGH CON ION, INC RESIDENCE, INCLUDING THE BASEMENT. ALL ALARM DEVICES ARE LICENSE NO. JBMCHI*21105 TO BE INTERCONNECTED ON ALL FLOORS. SMOKE ALARMS SHALL 6121 BAYVIEW DR NE BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE OF EACH TACOMA, WA 98422 SEPARATE SLEEPING AREA IN CLOSE PROXIMITY TO THE MOBILE: 253.730.1109 OFFICE: 253.952.9151 BEDROOMS. SMOKE ALARMS SHALL COMPLY WITH NFPA 72. 21. PROVIDE ATTIC ACCESS PULL DOWN STAIR OR MIN. 22 INCHES BY 30 INCHES AS LOCATED ON THE PLANS IN ACCORDANCE WITH IRC REQUIREMENTS. 22. PROVIDE ATTIC VENTILATION AT A RATE OF 1:300 OF AREA VENTED WITH AT LEAST 50% BUT NO MORE THAN 80% T-0" MIN. ABOVE EAVE 23. PROVIDE CRAWLSPACE ACCESS OPENINGS AS FOLLOWS: SHEET INDEX FOR FLOOR HATCHES 18" X24" MINIMUM FOR PERIMETER WALL ACCESS 16" X 24" MINIMUM. WHERE PERIMETER ACCESS IS PROVIDED BELOW GRADE, A 16" X 24" ARCHITECTURAL AREAWAY SHALL BE PROVIDED. A1.0 COVER SHEET, SITE PLAN & GENERAL INFO 24. SEPARATION WALLS AND CEILINGS BETWEEN GARAGE AND HOUSE TO A1.1 WASH STATE ENERGY COMPLIANCE FORMS - 2015 HAVE 5/8" TYPE X GYPSUM WALL BOARD ON THE GARAGE SIDE. DOORS BETWEEN GARAGE AND RESIDENCE TO BE A SELF -CLOSING, TIGHT FITTING SOLID WOOD DOOR (1-3/8" MIN. A-1 FOR REFERENCE ONLY 1979 REMODEL PLANS THICKNESS) 20 MIN. RATED A-2 FOR REFERENCE ONLY 1979 REMODEL ELEVATIONS 25. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE A-3 FOR REFERENCE ONLY 1979 REMODEL DETAILS EMERGENCY ESCAPE AND RESCUE OPENING. ESCAPE/RESCUE WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SF AND HAVE A MINIMUM NET CLEAR OPENING HEIGHT OF 24" AND A AE2.0 EXISTING BASEMENT LEVEL FLOOR PLAN MINIMUM NET CLEAR OPENING WIDTH OF 20". (GRADE FLOOR AE2.1 EXISTING MAIN LEVEL FLOOR PLAN A E TING RO P N ESCAPE RESCUE WINDOWS MAY HAVE A MIN. NET CLEAR OPENING . q OF 5.0 S.F.) ESCAPE/RESCUE WINDOWS SHALL HAVE A SILL HEIGHT AD2.0 BASEMENT LEVEL DEMOLITION PLAN NOT EXCEEDING 44" ABOVE FINISHED FLOOR. AD2.1 MAIN LEVEL DEMOLITION PLAN 26. HEATING OR COOLING EQUIPMENT (INCLUDING HOT WATER HEATERS) LOCATED IN THE GARAGE AND WHICH GENERATES A GLOW, SPARK AE3.0 I T R ELEVATIONS OR FLAME CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL BE AE4.0 OVERALL EXISTING BUILDING SECTIONS INSTALLED WITH THE PILOTS AND BURNERS OR HEATING A2.0 BASEMENT FLOOR PLAN ELEMENTS AND SWITCHES AT LEAST 18" ABOVE THE FLOOR LEVEL. A2.1 MAIN LEVEL FLOOR PLAN 27. CONTRACTOR DESIGNED SYSTEMS: FIRE SUPPRESSION, ELECTRICAL, PLUMBING, HVAC A5.0 INTERIOR ELEVATIONS ( CONTRACTOR TO OBTAIN REQUIRED PERMITS) A5.1 INTERIOR ELEVATIONS CONTRACTOR DESIGNED SYSTEMS SHALL MEET ALL CODE AND OWNER REQUIREMENTS AND SHALL BE ADEQUATELY SIZED TO A5.2 INTERIOR ELEVATIONS A5.3 INTERIOR ELEVATIONS AlSUPPLY BUILDING SPACES AND PROVIDE FOR ANTICIPATED LOADS. STRUCTURAL CONTRACTOR SHALL CONTACT ARCHITECT BEFORE S1.0 STRUCTURAL GENERAL NOTES & CALCULATIONS APPROPRIATING SPACE FOR DUCT WORK OR CREATING CHASES OR S2.0 STRUCTURAL FOUNDATION & MAIN FLOOR FRAMING PLANS SOFFITS NOT SHOWN ON PLANS. S2.1 STRUCTURAL ROOF FRAMING PLANS 28. BARE GALVANIZED METAL SHALL NOT BE USED FOR MATERIALS THAT S5.0 STRUCTURAL DETAILS CONVEY STORM WATER, SUCH AS SEDIMENT RISERS, ROOFS, CANOPIES, SIDING, GUTTERS, DOWNSPOUTS, ROOF DRAINS, AND PIPES. ANY GALVANIZED MATERIALS SHALL HAVE AN INERT, NON -LEACHABLE FINISH, SUCH AS BAKED ENAMEL, FLOUROCARBON PAINT (SUCH AS KYNAR OR HYLAR FACTORY APPLIED EPDXY, PURE ALUMINUM OR ASPHALT COATING, ACRYLIC PAINT, POLYESTER PAINT, FIELD APPLIED AND PART ZINC (SUCH AS GALVALUME) COATINGS ARE NOT ACCEPTABLE. APPLICABLE CODES ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES: * CURRENT CITY OF FEDERAL WAY MUNICIPAL CODE * 2015 INTERNATIONAL BUILDING CODE (IBC) + WAC 51-50 * 2015 INTERNATIONAL RESIDENTIAL CODE (IRC), WAC 51-51 * 2015 INTERNATIONAL MECHANICAL CODE (IMC), WAC 51-52 * 2015 INTERNATIONAL FUEL GAS CODE * 2015 INTERNATIONAL FIRE CODE (IFC) * 2015 WASHINGTON ENERGY CODE (WSEC) * 2017 NATIONAL ELECTRICAL CODE (NEC) WAC 296-43, 296-45 & 2tS-46B AND RCW 19.28 * * 2015 UNIFORM PLUMBING CODE (UPC) + WAC 51-56 & 51-57 DAVID POOL Architecture P11C David PoolArch it ectu re. 6716 East Side Dr NE Ste 1 - 500 Tacoma, WA 98422 253.651.4077 All material appearing herein constitutes the unpublished and original work of the Architect and may not be duplicated, used, or disclosed without the written consent of the Architect. WEEMENEW PROJECT: NELSON REMODEL PROJECT ADDRESS: 1408 SW 296th St. Federal Way WA §8023 PARCEL NO: 6 0621049036 General Contractor: McHugh Construction Inc. John McHugh 6121 Bayview Dr. NE Tacoma, WA 98422 M 253.730.1109 Contractors License: JBMCHI*21105 Structural ngineer: Swensen Say Faget Structural Engineers 934 Broadway, Suite 100 5205 NE 18th Ct Tacoma, WA 98402 P 253.888.4971 knomm" Document Release: REVISED DRAWINGS Agency Review 08.11.2020 Orginal Issue Date: Document Revision: No. Revised Date 10/12/2020 CITY REVIEW COMMENTS ARCHITECT'S Stamp: Drawing Title: COVER SHEET & GENERAL INFORMATION Sheet No. A190