Loading...
21-101703-Zoning Drawings-ATTCH 4-SC2064 Redondo BeachTITLE SHEETPROJECT SUMMARYPROJECT DESCRIPTIONLOCATION MAPTITLE SHEETINFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPG04/26/21Drawing Scale:Date:04/26/21AS NOTEDZDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023T-1Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C04/26/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WASHINGTON 9803390% ZONING DRAWINGINFINIGY ENGINEERING PLLC2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSDZISSUED FOR ZONINGDZDZAB04/26/21002/12/2104/02/214/29/21SHEETDESCRIPTIONSHEET INDEXT-1PROJECT:PSE POLE #:SITE #:FA #:PTN #:PACE #:USID #:SITE NAME:SITE ADDRESS:COUNTY:JURISDICTION:0VICINITY MAPREVAT&T PSE POLE REPLACEMENT312633-162543SC2064151806263801A0VQ6KMRWOR049216299659REDONDO BEACH29601 8TH AVE SWFEDERAL WAY, WA 98023KINGCITY OF FEDERAL WAYPROJECT TEAMSITE PHOTO·ALL WORK SHALL BE INSTALLED IN CONFORMANCE WITH CURRENT AT&T CONSTRUCTION INSTALLATION GUIDE.·EXISTING CONDITIONS WILL BE CHANGED & VERIFIED IN FIELD. IF SIGNIFICANT DEVIATIONS OR DETERIORATIONS ARE ENCOUNTEREDAT THE TIME OF CONSTRUCTION, A REPAIR PERMIT WELL BE OBTAINED & CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY.·THESE DRAWINGS ARE FULL SIZE & SCALABLE ON 11" X 17" SHEET SIZE.·STATEMENT OF COMPLIANCE WITH ENERGY CODE IS NOT REQUIRED.·SCOPE OF WORK DOES NOT INVOLVE MODIFICATIONS TO EXTERIOR ENVELOPE OF BUILDING, HVAC SYSTEMS OR ELECTRICAL LIGHTING.DIRECTIONS:AT&T PROPOSES THE INSTALLATION OF AN UNMANNED TELECOMMUNICATION FACILITY CONSISTING OFINSTALLING AN AT&T SHELTER WITHIN A NEW FENCED COMPOUND AND COLLOCATING AT&T ANTENNAEQUIPMENT ON A 55' UTILITY POLE REPLACEMENT BY PSE. NO WATER OR SEWER REQUIRED.·(1) NEW ANTENNA MOUNT·(6) NEW ANTENNAS·(12) NEW RRHS·(2) NEW RAYCAP SURGE SUPPRESSOR·(2) NEW FIBER LINE, (6) NEW DC POWER LINES·(1) NEW PRE-FABRICATED EQUIPMENT CABINET ON CONCRETE PAD WITH (1) NEW GPS ANTENNA·(1) NEW 20KW DIESEL GENERATOR ON CONCRETE PAD·NEW 200A ELECTRIC SERVICEPROJECTSITEPROJECTSITEDIRECTIONS FROM AT&T REGIONAL OFFICE:2018 INTERNATIONAL BUILDING CODE2020 NATIONAL ELECTRICAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 INTERNATIONAL FIRE CODEC-1SITE PLAN00C-2ELEVATIONShttps://app.leg.wa.gov/wac/default.aspx?cite=51DO NOT SCALE DRAWINGSCONTRACTOR SHALL VERIFY PLANS AND EXISTING DIMENSIONS ANDCONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THEARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDINGWITH THE WORK OR BE RESPONSIBLE FOR SAME.Callbefore you dig.below.Know what'sRTO OBTAIN LOCATION OF PARTICIPANTSUNDERGROUND FACILITIES BEFOREYOU DIG IN WASHINGTON, CALL UTILITYNOTIFICATION CENTERTOLL FREE: 1-800-424-5555 ORwww.callbeforeyoudig.orgWASHINGTON STATEREQUIRES MIN OF 2WORKING DAYS NOTICEBEFORE YOU EXCAVATEBUILDING CODESLEGAL DESCRIPTIONC-1.1COMPOUND PLAN0SMARTLINK TEAM:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033PROJECT MANAGEMENT:SITE ACQUISITION:ZONING SPECIALIST:ENGINEER:INFINIGY ENGINEERING PLLC2500 W. HIGGINS RD. SUITE 500HOFFMAN ESTATES, IL 60169(847) 648-4068CONSTRUCTION:MASTECBRIANNE PETERSEN RIGGINS(406) 749-0046NANCY SEARS (425) 444-1434nancy.sears@smartlinkgroup.comSITE NAME:REDONDO BEACHCOUNTY:KING COUNTYADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023ZONING: RS15.0LOT SIZE: ±2.32 ACRESAPN:062104-9042USE & OCCUPANCY GROUP:U - UTILITY & MISCELLANEOUSCONSTRUCTION TYPE:IIBSITE#:SC2064FA#:15180626PTN#:3801A0VQ6KLATITUDE (NAD 83):47.336517° (47° 20' 11.46'" N)LONGITUDE (NAD 83):-122.345075° (-122° 20' 42.27" W)GROUND ELEVATION (NAD 88):±267'(PER 1A CERTIFICATION BY DUNCANSON CO., DATED 03/26/21)GROUND OWNER:DAN LOURIEADDRESS:PO BOX 98258DES MOINES, WA 98198(206) 391-8750TOWER OWNER:PUGET SOUND ENERGYADDRESS:3380 146TH PLACE SEBELLEVUE, WA 98007TOWER CONTACT:ELIZABETH RAINIER(412) 400-9876APPLICANT:NEW CINGULAR WIRELESS PCS, LLC19801 SW 72ND AVENUE #200TUALATIN, OR 97062AT&T PROJECT MANAGER:VANESSA MEYER CROOKSAT&T CONSTRUCTION TOM LOGANCUT:±TBD CU. FT.GRADE:±TBD SQ. FT.FILL:±TBD CU. FT. AT 8" DEEPLOT 1 OF KCSP #783058 REC #8504100689 SD SP DAF POR OF NE 1/4 OF SW1/4 BEG NE COR OF SW 1/4 TH S 89-17-54 W ALG NLY LN THOF 372.70 FT TH S0-26-10 E 474.74 FT TH N 88-51-47 E 368.45 FT M/L TO ELY LN SD NE 1/4 OFSW 1/4 TH N 0-14-15 E ALG SD ELY LN 472.65 FT M/L TO POB LESS N 40 FT &LESS E 30 FTQUARTER-SECTION-TOWNSHIP-RANGE SW-6 -21-4·REDMOND TOWN CENTER·7525 166TH AVE NE, REDMOND, WA 98052·GET ON WA-520 W FROM NE LEARY WAY·FOLLOW WA-520 W, I-405 S AND I-5 S TO S 272ND ST IN KENT.·TAKE EXIT 147 FROM I-5 S·TAKE HWY 99 S/WA-509/PACIFIC HWY S AND S DASH POINT RD TO8TH AVE SW IN FEDERAL WAY·29601 8TH AVE SW, FEDERAL WAY, WA 98023DANIEL BAUM (206) 661-8053daniel.baum@smartlinkgroup.comSITE SURVEYSV1 SIGNAGE11/9/21INFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPD11/09/21Drawing Scale:Date:11/09/21AS NOTEDCDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023SP-2Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C11/09/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033ISSUED FOR REVIEWINFINIGY ENGINEERING, PLLC2500 W HIGGINS RD, SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSTJBDZA07/30/21B05/07/21REVISED PER COMMENTSTJB08/24/21CREVISED PER COMMENTSTJB10/04/21DREVISED PER COMMENTSTJB100% CONSTRUCTION DOCUMENTSTJB11/09/21011/02/21E3RF SIGNAGE (OR APPROVED EQUAL)SP-22HAZARDOUS MATERIAL SIGNAGE (OR APPROVED EQUAL) (IF REQUIRED)SP-21SITE IDENTIFICATION SIGNAGE (OR APPROVED EQUAL)SP-2 T HEDGEROWHEDGEROWASPHALT ASPHA L T SURFA C E SW 296TH ST 8TH AVE SWCLE A R E D B R U S H CLE A R E D B R U S H Δ SW 296TH ST 8TH AVE SWΔ POLE I.D.: 312633/162543 X ’ ” ’ ” ’ ” ’ ” D U N C A N S O N Company, Inc. 145 SW 155th Street, Suite 102 Seattle, Washington 98166 Phone 206.244.4141 Fax 206.244.4455 1 inch = ft. (IN FEET) GRAPHIC SCALE 1 inch = ft. (11x17 SHEET) 20 40 INFINIGY F R O M Z E R O IOT N F I the solutions are endless IN G Y SITE PUGET SOUND TX/RX2TX/RX1 TX MON2TX MON1 TX/RX2TX/RX1 TX MON2TX MON1 TX/RX2 TX/RX1 TX MON2 TX MON1 TX/RX2 TX/RX1 TX MON2 TX MON1 TX/RX2TX/RX1 TX MON2 TX MON1 TX/RX2TX/RX1 TX MON2 TX MON1 TX/RX2 TX/RX1 TX MON2 TX MON1 TX/RX2 TX/RX1TX MON2 TX MON1 TX/RX2TX/RX1 TX MON2TX MON1 SITE PLAN11/9/21INFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPD11/09/21Drawing Scale:Date:11/09/21AS NOTEDCDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023C-1Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C11/09/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033ISSUED FOR REVIEWINFINIGY ENGINEERING, PLLC2500 W HIGGINS RD, SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSTJBDZA07/30/21B05/07/21REVISED PER COMMENTSTJB08/24/21CREVISED PER COMMENTSTJB10/04/21DREVISED PER COMMENTSTJB100% CONSTRUCTION DOCUMENTSTJB11/09/21011/02/21ECALLED NORTH1/64"=1'-0" (11x17)SCALE:(OR)1/32"=1'-0" (24x36)010'30'20'1SITE PLAN C-1SW 296TH STAPPROXIMATE LOCATIONOF PROPERTY LINE (TYP.)PARENT PARCEL:062104-9042ZONING: RS15.0EXISTING UTILITYPOLE TO BE REMOVEDEXISTINGRESIDENCE(TYP.)8TH AVE SW ADJACENT PARCEL:195460-0005ZONING: RS15.0TOWER LOCATION INFORMATION (EXISTING UTILITY POLE):(PER 1A BY DUNCANSON CO., DATED 03/26/2021)LATITUDE (NAD 83):47.336517° (47° 20' 11.46'" N)LONGITUDE (NAD 83):-122.345075° (122° 20' 42.27" W)GROUND ELEVATION (NAD 88):±267'9TH AVE SW SW 298TH STADJACENT PARCEL:195460-0035ZONING: RS15.0ADJACENT PARCEL:062104-9128ZONING: RS15.0ADJACENT PARCEL:062104-9127ZONING: RS15.0ADJACENT PARCEL:720520-0205ZONING: RS9.6EXISTING TREES317'-11"299'-8"338'-3"272'-2" R 2 5 ' - 0 "30'-0"R.O.W.46'-1"R.O.W.30'-0"R.O.W.40'-0" R.O.W. 40'-0" R.O.W.NOTE:PARENT PARCEL IS BEING SUBDIVIDED BYOTHERS INTO LOTS 1 THROUGH 4 &TRACTS A (RETENTION POND) & B (ROAD)ADJACENT PARCEL:"LOT 2"ZONING: RS15.0ADJACENT PARCEL:"LOT 3"ZONING: RS15.0ADJACENT PARCEL:"LOT 4"ZONING: RS15.0PROPOSED AT&T ANTENNA AREA,SEE SHEETS C-1.1 & C-3 FOR DETAILSPROPOSED AT&TEQUIPMENT COMPOUND,SEE SHEET C-1.1 FOR DETAILSADJACENT PARCEL:"LOT 1"ZONING: RS15.0ADJACENT PARCEL:"TRACT A"ZONING: RS15.0±13'-5" TO SHELTER ±23'-11"TO SHELTER±36'-10" TO SHELTER 9TH AVE SW (PRIVATE ROAD)PROPOSEDREPLACEMENT UTILITYPOLE BY PSE±118'-2"TO SHELTERSETBACKS FOR SUBDIVIDED PARCELS:FRONT (9TH AVE SW): 20'-0"SIDE/REAR (8TH AVE SW): 20'-0"SIDE/REAR (SW 296TH ST): 10'-0"SIDE/REAR (INTERIOR): 5'-0" COMPOUND PLAN11/9/21INFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPD11/09/21Drawing Scale:Date:11/09/21AS NOTEDCDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023C-1.1Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C11/09/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033ISSUED FOR REVIEWINFINIGY ENGINEERING, PLLC2500 W HIGGINS RD, SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSTJBDZA07/30/21B05/07/21REVISED PER COMMENTSTJB08/24/21CREVISED PER COMMENTSTJB10/04/21DREVISED PER COMMENTSTJB100% CONSTRUCTION DOCUMENTSTJB11/09/21011/02/21ECALLED NORTHSCALE:(OR)02'4'8'1/16"=1'-0" (11x17)1/8"=1'-0" (24x36)2COMPOUND PLANC-1.1PROPOSED AT&TELECTRIC METERAND TELCO CABINETON NEW H-FRAMEPROPOSED AT&T UNDERGROUND CONDUITFOR TRANSMISSION CABLES ±155'-0"PROPOSED AT&T POLAR POWER20kW OUTDOOR GENERATORON 54GAL TANK ON CONCRETEPAD; VENT SHALL BE EXTENDEDTO 12' ABOVE GROUND LEVELIN ACCORDANCE WITHWASHINGTON STATE CODEPROPOSED AT&T25'x25' LEASE AREAPROPOSED AT&TVERTIV WIC SHELTERON CONCRETE PAD25'-0"25'- 0 " 15'-0"3'-6" 24'- 0 "24'-0"6'-0"15'-0"10'-0"4'-0"5'-0"5'-0"5'-0"5'-0"PROPOSED 12'-0"DOUBLE SWING GATEPROPOSED 6'-0" HIGH CHAINLINK FENCE WITH PRIVACY SLATSPROPOSED GRAVELPARKING AREAPROPOSED 5'-0" WIDETYPE 3 LANDSCAPING AREAPROPOSED GRAVELMAINTENANCE ACCESSPATH8TH AVE SW 12'-0"5'-0" WIDE SEWER EASEMENTPER SUBDIVISION BY OTHERS20'-0" BUILDING SETBACK LINEPER SUBDIVISION BY OTHERSPROPOSED SIDEWALK PERSUBDIVISION BY OTHERSPROPOSED LANDSCAPINGPER SUBDIVISION BY OTHERSRELOCATED SIGN PERSUBDIVISION BY OTHERSPROPOSED LANDSCAPE STRIPPER SUBDIVISION BY OTHERSPROPERTY LINE PERSUBDIVISION BY OTHERSRETAINING WALL PERSUBDIVISION BY OTHERSRETENTION POND PERSUBDIVISION BY OTHERSNOTES:PROPOSED SHELTER TO BE PAINTED BROWNTO BLEND IN WITH ITS SURROUNDINGS.FENCE SHALL HAVE A NON-REFLECTIVEPOWDER COATING OR PAINTING.EXISTING ROADEXISTING UTILITY POLETO BE REMOVEDPSE POLE #:312633-162543PROPOSED UTILITY POLE BY PSE;EXACT LOCATION TO BE PERPSE; UTILITY POLE TO BE USEDFOR FIBER & ELECTRIC ELECTRICCONNECTION; PENDING UTILITYCOORDINATIONEXISTING TREE TO BEREMOVED PERSUBDIVISION BY OTHERSEXISTING TREESEWER LINE FOR LOT 4 PERSUBDIVISION BY OTHERSSEWER LINE FOR LOT 1 PERSUBDIVISION BY OTHERS5'-0" BUILDING SETBACK LINEPER SUBDIVISION BY OTHERSSEWER LINE FOR LOT 4 PERSUBDIVISION BY OTHERSPROPOSED STORM DRAIN LINEPER SUBDIVISION BY OTHERSPROPOSED 12'-0" WIDE GRAVELMAINTENANCE ACCESS PATHPER SUBDIVISION BY OTHERSPROPOSED 20'-0" WIDE ASPHALTROAD PER SUBDIVISION BY OTHERSPROPERTY LINE PERSUBDIVISION BY OTHERS±9'-0"±13'-3"PROPOSED 12'-0" WIDEGRAVEL MAINTENANCEACCESS PATH PERSUBDIVISION BY OTHERS20'-0" BUILDING SETBACK LINEPER SUBDIVISION BY OTHERS±13'-2" FFFFFFF F F F F F F F F F ELEVATIONS11/9/21INFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPD11/09/21Drawing Scale:Date:11/09/21AS NOTEDCDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023C-2Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C11/09/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033ISSUED FOR REVIEWINFINIGY ENGINEERING, PLLC2500 W HIGGINS RD, SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSTJBDZA07/30/21B05/07/21REVISED PER COMMENTSTJB08/24/21CREVISED PER COMMENTSTJB10/04/21DREVISED PER COMMENTSTJB100% CONSTRUCTION DOCUMENTSTJB11/09/21011/02/21E1/4"=1'-0" (24x36)(OR)SCALE:1/8"=1'-0" (11x17)01'2'4'2PROPOSED ELEVATIONC-2PROPOSED (3) LINES OF AT&TPOWER TRUNK ROUTED UPUTILITY POLE; ±155'-0"PROPOSED (1) LINE OF AT&TFIBER TRUNK (24-PAIR PERFIBER LINE) ROUTED UPUTILITY POLE; ±155'-0"PROPOSED AT&T RRH'S (3)PER SECTOR, (9) TOTAL &(1) SURGE SUPPRESSORPROPOSED AT&TANTENNAS (2) PERSECTOR, (6) TOTAL1/4"=1'-0" (24x36)(OR)SCALE:1/8"=1'-0" (11x17)01'2'4'1EXISTING ELEVATIONC-2+/- 38'-5"TOP OF TOWER+/- 0'-0"GRADE···+/- 51'-0"PROPOSED AT&T ANTENNA CENTEREXISTING UTILITY POLE TOBE REMOVEDPSE POLE #:312633-162543+/- 55'-0"TOP OF TOWER+/- 0'-0"GRADEPROPOSED UTILITY POLE;DESIGN BY PSEPROPOSED AT&TUNDERGROUNDCONDUIT FORTRANSMISSION CABLESPROPOSED AT&T POLARPOWER 20KW OUTDOORGENERATOR ON 54GAL TANKON CONCRETE PAD; VENTSHALL BE EXTENDED TO 12'ABOVE GROUND LEVEL INACCORDANCE WITHWASHINGTON STATE CODEPROPOSED AT&TVERTIV WIC SHELTERON CONCRETE PADPROPOSED 6'-0" H.CHAIN LINK FENCEWITH PRIVACY SLATSPROPOSED 5'-0" W.TYPE 3 LANDSCAPINGAREA+/- 37'-7"C/L OF TOP POWER LINES+/- 37'-7"C/L OF TOP POWER LINESEXISTING POWER LINES ANDASSOCIATED EQUIPMENT TOBE RELOCATED TO PROPOSEDPOLE; FINAL HEIGHTS TO BEDETERMINED BY PSEEXISTING POWER LINES ANDASSOCIATED EQUIPMENT TOBE RELOCATED TO PROPOSEDPOLE; FINAL HEIGHTS TO BEDETERMINED BY PSE+/- 60'-0"TOP OF LIGHTNING RODPROPOSED 5'-0" TALLLIGHTNING ROD1/4"=1'-0" (24x36)(OR)SCALE:1/8"=1'-0" (11x17)01'2'4'3PROPOSED COMPOUND ELEVATIONC-2± 0'-0"GRADEPROPOSED AT&TVERTIV WIC SHELTERON CONCRETE PADPROPOSED 6'-0" H.CHAIN LINK FENCEWITH PRIVACY SLATSPROPOSED 5'-0" W.TYPE 3 LANDSCAPINGAREA± 6'-0"TOP OF FENCE± 9'-9"TOP OF SHELTERNOTES:PROPOSED SHELTER TO BEPAINTED BROWN TO BLENDIN WITH ITS SURROUNDINGS.FENCE SHALL HAVE ANON-REFLECTIVE POWDERCOATING OR PAINTING.EXISTING TREE 11/9/21INFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPD11/09/21Drawing Scale:Date:11/09/21AS NOTEDCDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023L-1Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C11/09/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033ISSUED FOR REVIEWINFINIGY ENGINEERING, PLLC2500 W HIGGINS RD, SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSTJBDZA07/30/21B05/07/21REVISED PER COMMENTSTJB08/24/21CREVISED PER COMMENTSTJB10/04/21DREVISED PER COMMENTSTJB100% CONSTRUCTION DOCUMENTSTJB11/09/21011/02/21ELANDSCAPING NOTESSCOPE OF LANDSCAPING SUMMARY OF LANDSCAPING WORK:1.PROTECTION AND PRESERVATION OF EXISTING TREES AND PLANTING DURING CONSTRUCTION.2.SUPPLY AND INSTALLATION OF GROWING MEDIUM.3.SUPPLY AND INSTALLATION OF PLANT MATERIAL.4.SUPPLY AND INSTALLATION OF AUTOMATIC IRRIGATION SYSTEM. INSURE GOOD COVERAGE FORALL PLANTING AREAS.5.MAINTENANCE: PROVIDE ONE (1) FULL YEAR MAINTENANCE OF ALL LANDSCAPE AREAS,COMMENCING ON DATE OF SUBSTANTIAL COMPLETION.VERIFICATION OF DIMENSIONS AND QUANTITIES:6.BEFORE PROCEEDING WITH THE WORK, VISIT THE SITE AND CAREFULLY CHECK AND VERIFYDIMENSIONS AND QUANTITIES. REPORT VARIATIONS BETWEEN DRAWINGS AND SITE TO THECONSULTANT BEFORE PROCEEDING WITH THE WORK.QUALITY ASSURANCE:7.LOCAL JURISDICTION NURSERY TRADES ASSOCIATION GUIDE SPECIFICATIONS FOR NURSERYSTOCK SHALL APPLY.8.ALL LANDSCAPING AND PLANT MATERIAL SHALL BE IN ACCORDANCE WITH LOCAL JURISDICTIONSTANDARDS, CURRENT EDITION.9.ALL MATERIALS SHALL BE OF THE QUALITY SPECIFIED OR ACCEPTABLE TO THE CONSULTANT.UNIT SAMPLES OF MATERIALS SHALL BE SUBMITTED UPON THE REQUEST OF THE CONSULTANT.GUARANTEE:10.GUARANTEE THE WORK AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OFSUBSTANTIAL PERFORMANCE.DELIVERY AND STORAGE OF MATERIALS:11.ALL MANUFACTURED MATERIALS, SUCH AS FERTILIZER, BONEMEAL, MULCHES, ETC., SHALL BEDELIVERED TO, AND STORED ON THE SITE IN STANDARD CONTAINERS CLEARLY INDICATINGCONTENTS, WEIGHT, ANALYSIS, AND NAME OF THE MANUFACTURER.12.ALL MATERIALS WHICH ARE SUBJECT TO DETERIORATION RESULTING FROM WEATHER, OR ANYOTHER CAUSES, SHALL BE STORED ON THE SITE IN A DRY WEATHERPROOF PLACE IN SUCH AMANNER THAT THEIR EFFECTIVENESS WILL NOT BE IMPAIRED.SHRUB AND TREE PRESERVATION GENERAL:13.FURNISH ALL TREE PROTECTION, WATERING, FERTILIZING, AND PRESERVING ROOT SYSTEMSAFFECTED BY CHANGING GRADES OR CONSTRUCTION. THIS WORK IS TO BE DONE BY ANAPPROVED LANDSCAPE CONTRACTOR, PRIOR TO COMMENCING ANY WORK ON THE SITE.PRODUCTS:14.FERTILIZER: COMPLETE COMMERCIAL SLOW RELEASE FERTILIZER (1 0-6-4 OR APPROVED TYPE)WITH 49% OF ELEMENTS DERIVED FROM ORGANIC SOURCES.15.WATER: POTABLE TYPEEXECUTION:16.UNDER SUPERVISION OF THE CONSULTANT, RETAIN AND PROTECT ALL EXISTING TREES ANDSHRUBS AS INDICATED ON THE DRAWINGS, AND IDENTIFIED ON THE SITE.17.TREE PROTECTION SHALL BE PLACED BEFORE ANY CONSTRUCTION OR GRADING IS BEGUN ANDSHALL BE MAINTAINED IN REPAIR FOR THE DURATION OF THE CONSTRUCTION WORK.18.ENCASE THE AREA OUTSIDE THE DRIPLINE WITH CHAIN LINK FENCING AND METAL POSTS.METAL POSTS MUST BE SET 36" INTO THE GROUND AND AT INTERVALS OF NOT MORE THAN6'-0" O.C, OR AS SHOWN ON THE DRAWINGS.19.PROTECT ROOTS OF DESIGNATED TREES TO DRIPLINE TO PREVENT DISTURBANCE OR DAMAGE.AVOID TRAFFIC AND DUMPING AND STORAGE OF MATERIALS OVER ROOT ZONES. NO MATERIALSHALL STORED WITHIN 40' OF ANY TREE DESIGNATED TO BE SAVED.20.TREE PROTECTION IS TO REMAIN UNTIL THE PLANTING WORK IS STARTED, AND THEN REMOVED.21.PLANT MATERIAL WITHIN THE PROTECTION AREAS THAT HAS BEEN DAMAGED BEYOND REPAIRBY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR WITH THE SAME SPECIES ANDGROWTH AT NO COST TO THE OWNER.FERTILIZING EXISTING TREES:22.APPLY COMPLETE FERTILIZER AT THE RATE SPECIFIED ON THE CONTAINER TO ALL TREES TO BERETAINED. APPLY FERTILIZER WHEN FENCING IS ERECTED, AND ONCE AGAIN EARLY IN THEGROWING SEASON.23.DISTRIBUTE FERTILIZER EQUALLY INTO HOLES DRILLED 8 -10 IN. DEEP SPACED 2'-0" - 2'-6" APART,IN A CIRCULAR PATTERN WITHIN THE DRIPLINE OF EACH TREE TO BE RETAINED.24.WATER THOROUGHLY AFTER FERTILIZER IS APPLIED. WATER ALL TREES TO BE RETAINEDTHROUGHOUT THE CONSTRUCTION PERIOD TO ENSURE THAT ROOTS ARE NEVER DRY. SOAKAREA IMMEDIATELY BELOW TREE CROWN SUFFICIENTLY DEEP TO REACH FEEDER ROOTS.GROWING MEDIUM PREPARATION AND PLACEMENT GENERAL:25.WORK INCLUDED: FURNISH ALL LABOUR, MATERIALS, AND EQUIPMENT NECESSARY FOR THEPREPARATION AND PLACEMENT OF THE GROWING MEDIUM, DRAINAGE COURSE, FILTER FABRICAND CLEAN-OUTS.26.DEFINITIONS: FOR THE PURPOSES OF THIS SPECIFICATION, THE TERM "GROWING MEDIUM"SHALL MEAN A COMPOSITION OF THE VARIOUS BASIC MATERIALS AND FERTILIZERS FORSUPPORTING HEALTHY PLANT GROWTH.27.EXISTING CONDITIONS:27.1.EXAMINE EXISTING SUBGRADE CONDITIONS AND SIGNIFY ACCEPTANCE IN WRITING TO THECONSULTANT.27.2.ASCERTAIN THE SIZE AND LOCATION OF ALL EXISTING SERVICES AND SUBGRADES PRIOR TOTHE WORK.27.3.REPAIR DAMAGE RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTIONS IMMEDIATELYAT NO COST TO THE OWNER.28.TESTING: THE LANDSCAPE SUBCONTRACTOR IS RESPONSIBLE FOR TESTING THE ONSITE ANDIMPORTED TOPSOIL. SOIL TEST SHALL INCLUDE MEASURABLE PHYSICAL AND CHEMICALPROPERTIES. THE TEST SHALL DETERMINE THE ANALYSIS AND QUANTITY OF FERTILZER, LIME (IFREQUIRED) AND/OR OTHER ADDITIVES TO BE USED TO BRING IT TO A SATISFACTORY CHEMICALAND PHYSICAL CONDITION. BEFORE ADJUSTING THE TOPSOIL AS REQUIRED BY THE SOILSTESTING, SUBMIT SOILS ANALYSIS TO THE CONSULTANT FOR APPROVAL. CONTRACTOR SHALLBEAR ALL COSTS INCURRED BY SOIL ANALYSIS FOR SOIL RECOMMENDATION AND TESTING.29.PRODUCT HANDLING:29.1.ALL MATERIALS TO BE HANDLED AND ADEQUATELY PROTECTED TO PREVENT DAMAGE.29.2.STOCKPILE MATERIALS IN BULK FORM IN PAVED AREAS. PROVIDE ADDITIONAL PROTECTION OFSTORAGE UNDER ROOF OR TARPAULINS FOR BULK FORMS OF PEAT MOSS. TAKE PRECAUTIONSTO PREVENT CONTAMINATION OF BASIC MATERIALS FROM WINDBLOWN SOIL PARTICLES,WEED SEEDS, AND FROM INSECTS. CONTAMINATION OF THE INGREDIENTS MAY RESULT INTHEIR REJECTION FOR USE.29.3.STORE FERTILIZER AND CHEMICAL INGREDIENTS IN THE MANUFACTURER'S ORIGINALCONTAINERS.30.STORAGE OF FINISHED GROWING MEDIUM: STORE GROWING MEDIUM IN A DRY AREA ANDPROTECTED FROM CONTAMINATION, DAMAGE, AND THE ELEMENTS.31.INSPECTION: NOTIFY THE CONSULTANT AT LEAST FOURTY-EIGHT (48) HOURS PRIOR TO SOILPLACEMENT TO INSPECT TOPSOIL.GROWING MEDIUM PREPARATION AND PLACEMENT MATERIALS:32.ON SITE SOIL32.1.ON SITE SOIL MAY BE USED, PROVIDED THAT IT MEETS THE STANDARDS SET FOR IMPORTEDSOIL WHEN EVALUATED THROUGH SOIL ANALYSIS AND/OR CAN BE REASONABLY MODIFIED TOMEET THE REQUIREMENTS SET OUT FOR THE GROWING MEDIUM. ON SITE SOIL SHOULD NOTBE ASSUMED TO ACCEPTABLE FOR THE PROJECT WITHOUT A LABORATORY ANALYSIS. NATIVETOPSOIL SHOULD BE STOCKPILED ON THE SITE IN AREAS DESIGNATED FOR THIS PURPOSE INTHE CONSTRUCTION PLAN.32.2.ALL AREAS DESIGNATED FOR PAVING, OR THE CONSTRUCTION OF STRUCTURES, SHALL BESTRIPPED OF ALL TOPSOIL AND ORGANIC MATTER. WHENEVER FEASIBLE, THE CONTRACTORWILL AVOID HARVESTING TOPSOIL. WHILE IT IS NOT CONSIDERED A NECESSITY, IT WOULD BE ABENEFIT TO COVER STOCKPILES WITH PLASTIC OR CANVAS TO MAINTAIN DRY SOILCONDITIONS.32.3.TOPSOIL SHALL BE STRIPPED TO ITS FULL DEPTH AS DETERMINED BY A QUALIFIED SOILSCIENTIST (OR APPROVED EQUIVALENT), OBSERVING APPROPRIATE CARE NOT TO MIX TOPSOILAND SUBSOIL. SUBSOIL MAY BE STORED SEPARATELY FROM THE TOPSOIL IN THE EVENT THATIT MAY BE UTILIZED FOR THE PROJECT. STOCKPILED TOPSOIL AND SUBSOIL SHOULD BEANALYZED SEPARATELY IF BOTH ARE TO BE USED FOR THE PROJECT.32.4.TOPSOIL STRIPPING SHALL COMMENCE AFTER THE AREA HAS BEEN CLEARED OF ALL SHRUBS,PLANTS, WEEDS, GRASS, STUMPS, ROCKS (4" AND LARGER), AND ANY OTHER EXTRANEOUSMATERIALS NOT POSITIVELY CONTRIBUTING TO THE FINISHED PROJECT. THE ABOVE LISTEDWASTE MATERIALS SHOULD BE REMOVED FROM THE SITE.33.IMPORTED TOPSOIL33.1.IT IS IMPORTANT AT THIS POINT TO DIFFERENTIATE IMPORTED TOPSOIL FROM IMPORTED SOILPREPARATIONS. TOPSOIL IS A NATURAL RESOURCE RESULTING FROM THE INTERACTION OFMINERAL PARENT MATERIALS, VEGETATION, CLIMATE, SOURCE TOPOGRAPHY, AND A TIMEFACTOR. SOIL PREPARATIONS ARE MAN-MADE PRODUCTS OF MIXING MINERAL AND ORGANICCOMPONENTS. THE PREPARATIONS ARE OFTEN LARGELY COMPOSED OF SAND AND PEATSMIXED MANUALLY BUT DISPLAYING LITTLE OR NO STRUCTURAL DEVELOPMENT AND FOR ALLINTENTS AND PURPOSES, NO TIME FACTOR. FOR THE ABOVE REASON, THIS LIST OFSPECIFICATIONS DOES NOT REFER TO SOIL PREPARATIONS AS TOPSOIL. SOIL PREPARATIONMAY BE VIEWED AS THE BEST POTENTIAL SUBSTITUTE AVAILABLE FOR THE LIMITED RESOURCETERMED TOPSOIL.33.2.IT IS FEASIBLE THAT AN IMPORTED SOIL COULD BE TOPSOIL. IN THIS SITUATION A PRECISELOCATION AND BRIEF HISTORY OF THE TOPSOIL WOULD PROVIDED BY THE SUPPLIER. THEPURPOSE OF THE BRIEF HISTORY OF THE TOPSOIL IS TO AVOID HARVESTING OF SOIL WHICHMAY HAVE SUPPORTED UNDESIRABLE PLANT SPECIES (IE. CRABGRASS, COUCHGRASS,EQUISETUM, NOXIOUS WEEDS) AND/OR THEIR DEPOSITED SEEDS OR MAY HAVE BEEN INCONTACT WITH UNDESIRABLE TOXIC MATERIALS(HERBICIDES, INSECTICIDES, OILS, FUELS, ETC.).33.3.NATURAL, FERTILE, AGRICULTURAL SOIL, CAPABLE OF SUSTAINING VIGOROUS PL.ANTGROWTH. OF UNIFORM COMPOSITION THROUGHOUT, WITHOUT ADMIXTURE OF SUBSOIL.FREE OF STONES, LUMPS, LIVE PLANTS AND THEIR ROOTS, STICKS, AND OTHER EXTRANEOUSMATTER.33.4.ACIDITY RANGE OF PH 5.0 TO PH 7.0 CONTAINING NOT LESS THAN SIX PERCENT (6%) ORGANICMATTER.34.PEAT MOSS: DECOMPOSED FIBROUS CELLULAR STEMS AND LEAVES OF SPECIES OF SPHAGNUMMOSSES CONSISTING OF A MINIMUM OF 90%0RGANIC MATTER BY DRY WEIGHT BASIS, FINELYGROUND TO ENABLE MIXING WITH OTHER COMPONENTS; 100% BY VOLUME OF THE PARTICLESIZES TO PASS A #4 SIEVE WITH A MINIMUM OF 97.5% PASSING A #8 SIEVE.35.PUMICE: A GROUND POROUS VOLCANIC ROCK, DARK BROWN TO BLACK IN COLOUR.36.MUSHROOM MANURE: WELL-ROTTED, UNLEACHED MUSHROOM MANURE, FREE OF WEEDS,SALT, AND NOXIOUS SUBSTANCES. PROVIDE A SAMPLE TO PACIFIC SOIL ANALYSIS FORINSPECTION AND APPROVAL. APPROVED SAMPLE SHALL BE STANDARD THROUGHOUT.37.PUMP RIVER SAND: SAND SHALL BE PUMPED FROM A RIVER AND FREE OF SALT, DEBRIS, WEEDSAND TOXIC CHEMICALS. SAND SHALL BE 49%MEDIUM AND 49% COURSE SAND. PROVIDE ASAMPLE TO PACIFIC SOIL ANALYSIS FOR INSPECTION AND APPROVAL. APPROVED SAMPLE SHALLBE STANDARD THROUGHOUT.38.FERTILIZER AND CHEMICAL INGREDIENTS: LIST AVERAGE P.P.M. OF PRIMARY NUTRIENTS WHEREAPPLICABLE FINELY GROUND, GRANULAR OR WATER SOLUBLE FORM TO PERMIT THEIRUNIFORM DISTRIBUTION THROUGHOUT THE MIX.38.1.NITROGEN FERTILIZER: 49% OF TOTAL NITROGEN DERIVED FROM A NATURAL ORGANICMATERIAL IN A SLOW RELEASE FORM.38.2.BONEMEAL: FINELY GROUND COMMERCIAL RAW BONEMEAL WITH MINIMUM 4% NITROGENAND MINIMUM OF 20% PHOSPHORIC ACID.38.3.NUTRICOTE (BY AGRICO): 16-10-10.39.DRAINAGE AND FILTER:39.1.DRAIN ROCK: ¾" - 1" DIAMETER ROUND ROCK WASHED FREE OF ALL FINES AND ORGANICMATERIALS.39.2.FILTER FABRIC: HEAT BONDED, ROT-PROOF, NON-WOVEN FABRIC, OR APPROVED EQUAL.40.CLEANOUTS: 6" DIAMETER PVC PIPE, LENGTHS AS REQUIRED. 6" DIAMETER PVC CAPS, BLACK INCOLOUR.41.FEEDER TUBES: 4" DIAMETER PVC PIPE, LENGTHS AS REQUIRED.GROWING MEDIUM PREPARATION AND PLACEMENT EXECUTION:42.GROWING MEDIUM AMENDMENTS: GROWING MEDIUMS SHALL VARY ACCORDING TOPLANTING AREAS AND ACCORDING TO PACIFIC SOIL ANALYSIS RECOMMENDATIONS.APPROXIMATE VOLUMES ONLY.42.1.SOD AREAS: BY VOLUME 80% SAND MIX, 10% SOIL, 10%MUSHROOM MANURE TO BE SPREAD2" DEEP OVER SAND AND SOIL MIX, DIG INTO TOP 4" OF SAND AND SOIL MIX. ADD FERTILIZERAND OTHER AMENDMENTS AS SPECIFIED BY SOIL CONSULTANT.42.2.TREE AND SHRUB AREAS: BY VOLUME 60% SAND MIX, 20%TOPSOIL, 20% MUSHROOMMANURE TO BE SPREAD 6" DEEP LAYER OVER SAND AND SOIL MIX. ADD FERTILIZER ANDOTHER AMENDMENTS AS SPECIFIED BY SOIL CONSULTANT.43.PLACEMENT ON GRADE:43.1.CULTIVATE ENTIRE SUBGRADE TO A DEPTH OF 12" IMMEDIATELY PRIOR TO PLACEMENT OFTHE GROWING MEDIUM.43.2.NO GROWING MEDIUM SHALL BE LOADED, TRANSPORTED, OR SPREAD WHEN IT IS SO WETTHAT ITS STRUCTURE IS LIKELY TO BE ALTERED.43.3.PLACE GROWING MEDIUM TO THE FOLLOWING DEPTHS:43.4.GROUNDCOVER AREAS 1 '-5"43.5.SHRUB AREAS 1'-5"43.6.LAWN AREAS 1 '-0"43.7.FINE GRADE GROWING MEDIUM TO FINISH GRADES SHOWN ELIMINATING ROUGH SPOTS ANDLOW AREAS TO ENSURE POSITIVE DRAINAGE. PREPARE LOOSE FRIABLE BEDS BY MEANS OFDISCING AND SUBSEQUENT RAKING.43.8.CLEANOUTS:43.9.CUT V-SHAPED NOTCHES AT ONE END OF 6" DIAMETER PVC PIPE. PLACE NOTCHED END OVERROOF DRAIN, SURROUND WITH 2" DEPTH DRAIN ROCK AND RUN FILTER FABRIC 8" UP AROUNDPIPE.43.10.ENSURE TOP OF PIPE IS FLUSH WITH FINISH GRADE AND COVER WITH PVC CAP, BLACK INCOLOUR. 11/9/21INFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPD11/09/21Drawing Scale:Date:11/09/21AS NOTEDCDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023L-2Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C11/09/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033ISSUED FOR REVIEWINFINIGY ENGINEERING, PLLC2500 W HIGGINS RD, SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSTJBDZA07/30/21B05/07/21REVISED PER COMMENTSTJB08/24/21CREVISED PER COMMENTSTJB10/04/21DREVISED PER COMMENTSTJB100% CONSTRUCTION DOCUMENTSTJB11/09/21011/02/21ELANDSCAPING NOTESPLANTS AND PLANTING GENERAL:1.QUALITY ASSURANCE: ALL MATERIALS AND EXECUTION TO CONFORM TO THE LATEST EDITION OF THEFOLLOWING STANDARDS OR AS OTHERWISE SPECIFIED.1.1.LOCAL JURISDICTION GUIDE SPECIFICATIONS FOR NURSERY STOCK.1.2.LOCAL JURISDICTION GUIDE SPECIFICATIONS FOR LANDSCAPE CONSTRUCTION.2.SUBMITTALS: SUBMIT INSPECTION CERTIFICATES AS REQUIRED BY LAW FOR EACH SHIPMENT OF PLANTMATERIAL.3.DELIVERY AND STORAGE:3.1.DIG AND HANDLE ALL PLANT MATERIAL IN A MANNER SUITABLE FOR EACH SPECIES TO PREVENT INJURYTO OR REMOVAL OF FIBROUS ROOTS. ALL PLANT MATERIAL ARRIVING ON SITE WITH BROKEN OR LOOSEROOT BALLS WILL BE REJECTED. TAKE PRECAUTIONS TO AVOID BURNING OF PLANTS BY SUN OR WINDDURING HANDLING AND SHIPPING3.2.KEEP ROOT BALLS AND CONTAINER SOIL MOIST BEFORE PLANTING BY COVERING WITH BARK MULCH ORSOIL. PROTECT FERTILIZER AGAINST MOISTURE.4.PROTECTION:4.1.VERIFY EXISTENCE AND LOCATION OF ANY ON-SITE UTILITIES. CONSULT THE CONSULTANT IMMEDIATELYFOR DIRECTIONS AS TO PROCEDURE SHOULD ANY PIPING OR UTILITIES BE ENCOUNTERED DURINGEXCAVATION.4.2.PROTECT EXISTING BUILDINGS, EQUIPMENT, SIDEWALKS, LANDSCAPING REFERENCE POINTS,MONUMENTS AND MARKERS. MAKE GOOD ALL DAMAGE INCURRED DURING THIS WORK.4.3.MAKE EVERY EFFORT TO PROTECT PLANTS ADJACENT TO ANY CONSTRUCTION WORK.4.4.ERECT TEMPORARY CONTINUOUS BARRIERS WHERE NECESSARY TO ENSURE SAFETY OF EXISTING PLANTSAND TREES AS SHOWN ON THE DRAWINGS, OR AS REQUIRED.4.5.REPLACE, AT NO EXPENSE TO THE OWNER, ANY TREES AND PLANT MATERIAL DAMAGED5.INSPECTION:5.1.MAKE ALL PLANT MATERIAL AVAILABLE AT ONE LOCATION 12 MONTHS AND ALSO TEN (10) DAYS PRIORTO SCHEDULED PLANTING TIME FOR INSPECTION BY THE CONSULTANT.5.2.NOTIFY THE CONSULTANT WHEN THE PLANTS ARE AVAILABLE FOR INSPECTION. ALL PLANTS ARE SUBJECTTO INSPECTION AND MAY BE REJECTED FOR FAILURE TO COMPLY WITH THIS SPECIFICATION AT ANY TIMEUNTIL TOTAL PERFORMANCE. REPLACE REJECTED PLANT MATERIAL AND REMOVE FROM THE SITE AT NOCOST TO THE OWNER.5.3.NOTIFY THE CONSULTANT AT THE COMPLETION OF THE WORK FOR AN INSPECTION FOR SUBSTANTIALPERFORMANCE.5.4.FINAL INSPECTION OF ALL PLANTING WILL BE MADE AT THE ENO OF THE SPECIFIED GUARANTEE PERIOD.FOR RELEASE FROM THE CONTRACT, ALL PLANT MATERIALS SUPPLIED OR TRANSPLANTED BY THECONTRACTOR MUST BE ALIVE AND IN A HEALTHY, SATISFACTORY GROWING CONDITION AT THE TIME OFTHE INSPECTION. FOR SPECIFIED PLANT, THE CONSULTANT RESERVES THE RIGHT TO EXTEND THECONTRACTOR'S RESPONSIBILITY FOR ANOTHER GROWING SEASON, IF IN HIS OR HER OPINION, LEAFDEVELOPMENT AND GROWTH IS NOT SUFFICIENT TO ENSURE SATISFACTORY FUTURE GROWTH.5.5.THE CONSULTANT AT HIS DISCRETION MAY WAIVE ONE OR MORE INSPECTIONS, BUT THIS SHALL NOTIMPAIR THE RIGHT OF THE CONSULTANT TO INSPECT WORK OR MATERIALS WHICH HAVE BEENDAMAGED OR IN ANY WAY DO NOT CONFORM TO THE SPECIFICATIONS.5.6.THE CONTRACTOR OR HIS AUTHORIZED REPRESENTATIVE SHALL BE PRESENT DURING ALL REQUIREDINSPECTIONS AS SPECIFIED OR AS MAY BE REQUIRED BY THE CONSULTANT.6.REPLACMENTS:6.1.REPLACE ALL PLANT MATERIAL FOUND DEAD, OR NOT IN A HEALTHY, SATISFACTORY GROWINGCONDITION OR WHICH, IN ANY OTHER WAY, DO NOT MEET THE REQUIREMENTS FOR THESPECIFICATIONS, AT OWN EXPENSE, WHERE MAINTENANCE DURING THE GUARANTEE PERIOD IS THERESPONSIBILITY OF THE CONTRACTOR.6.2.THE COST OF REPLACEMENTS RESULTING FROM THEFT, ACCIDENTAL DAMAGE, VANDALISM,CARELESSNESS OR NEGLECT ON THE PART OF OTHERS, OR ANY OTHER CAUSE DUE TO CIRCUMSTANCESBEYOND THE CONTROL OF THE CONTRACTOR, SHALL BE BORNE BY THE OWNER.6.3.REQUIRED REPLACEMENTS SHALL BE PLANTS AT THE SAME SIZE AND SPECIES AS SPECIFIED ON THEPLANT LIST AND SHALL BE SUPPLIED AND PLANTED IN ACCORDANCE WITH THE DRAWINGS,SPECIFICATIONS, AND CHANGE ORDERS THERETO.6.4.REPLACE EACH DEFECTIVE OR DEAD PLANT DURING THE NEXT PLANTING SEASON AND CONTINUE TOREPLACE EACH PLANT UNTIL IT HAS ESTABLISHED ITSELF TO THE SATISFACTION OF THE CONSULTANT.7.SUBSTITUTIONS: IF IT IS IMPOSSIBLE TO OBTAIN THE PARTICULAR PLANT MATERIAL LISTED ON THELANDSCAPE PLAN, THE CONTRACTOR MAY BE PERMITTED TO SUGGEST SUBSTITUTIONS WITH TYPES ANDVARIATIONS POSSESSING THE SAME CHARACTERISTICS. THE CONTRACTOR MUST REQUEST ANYSUBSTITUTIONS IN WRITING AT LEAST TWELVE (12) MONTHS PRIOR TO PLANTING. SUBSTITUTIONS MUST BEAPPROVED BY THE CONSULTANT.8.MAINTENANCE:8.1.THE MAINTENANCE PERIOD BEGINS AT THE DATE OF INSTALLATION AND CONTINUES UNTIL THE DATE OFSUBSTANTIAL PERFORMANCE.8.2.MAINTENANCE INCLUDES NECESSARY WATERING, CULTIVATION, WEEDING, PRUNING, MOWING,AERATING, DISEASE AND INSECT CONTROL, PROTECTIVE SPRAYING, REPLACEMENT OF UNACCEPTABLEMATERIAL, STRAIGHTENING PLANTS WHICH LEAN OR SAG, ADJUSTMENT OF PLANTS WHICH SETTLE ORARE PLANTED TOO LOW, AND ANY OTHER PROCEDURES CONSISTENT WITH GOOD HORTICULTURALPRACTICE NECESSARY TO INSURE NORMAL, VIGOROUS AND HEALTHY GROWTH OF ALL WORK UNDERTHIS CONTRACT.8.3.MAINTAIN ALL ACCESSORIES SUCH AS TREE STAKES, ETC., IN GOOD CONDITION, INCLUDINGADJUSTMENT, AND REPAIR OR REPLACE ALL SUCH ACCESSORIES WHEN REQUIRED.9.AREA OF PLANT SUPPLY AND SEARCH: BEFORE SUBSTITUTIONS OF PLANT MATERIAL ARE PROPOSED, PROOFTHAT MATERIALS ARE NOT AVAILABLE THROUGH SEARCH ON THE WEST COAST OF CANADA AND THE UNITEDSTATES MUST BE PROVIDED. AREA OF SUPPLY SHALL INCLUDE BUT NOT BE LIMITED TO THE AREA ASMENTIONED HEREIN.10.DELIVERY AND STORAGE:10.1.DIG AND HANDLE ALL PLANT MATERIAL IN A MANNER SUITABLE FOR EACH SPECIES TO PREVENT INJURYTO OR REMOVAL OF FIBROUS ROOTS. ALL PLANT MATERIAL ARRIVING ON SITE WITH BROKEN OR LOOSEROOT BALLS WILL BE REJECTED. TAKE PRECAUTIONS TO AVOID BURNING OF PLANTS BY SUN OR WINDDURING HANDLING AND SHIPPING10.2.KEEP ROOT BALLS AND CONTAINER SOIL MOIST BEFORE PLANTING BY COVERING WITH BARK MULCH ORSOIL. PROTECT FERTILIZER AGAINST MOISTURE.PRODUCTS - PLANT MATERIAL:11.OF SIZES AND QUANTITIES SHOWN IN PLANT LISTS ON LANDSCAPE DRAWINGS AND SPECIFICATION: NURSERYGROWN.12.CONFORM TO THE LOCAL JURISDICTION NURSERY TRADES ASSOCIATION"GUIDE SPECIFICATION FOR NURSERY STOCK". IN PARTICULAR:12.1."NURSERY STOCK SHALL BE TRUE TO NAME, AND OF THE SIZE OR GRADE STATED."12.2."QUALITY SHALL BE NORMAL FOR THE SPECIES WHEN GROWN UNDER PROPER CULTURAL CONDITIONS... VIABLE, SUBSTANTIALLY FREE FROM PESTS AND DISEASE, AND UNDAMAGED."12.3."ROOTS SHALL NOT BE SUBJECT TO LONG EXPOSURE TO DRYING WINDS, SUN OR FROST, BETWEENDIGGING AND DELIVERY."12.4."ROOT BALLS SHALL BE FREE FROM PERNICIOUS PERENNIAL WEEDS"13.TRANSPLANTED OR ROOT PRUNED AT LEAST ONCE WITHIN THE YEAR PRIOR TO PLANTING.14.TAKE PRECAUTIONS DURING DIGGING, HANDLING, AND SHIPPING OF PLANT MATERIAL TO AVOID INJURY TOPLANTS AND ROOT SYSTEMS.15.ALL PLANTS: TYPICAL OF THEIR SPECIES OR VARIETY, HAVE A NORMAL HABIT OF GROWTH, AND SHALL BEFIRST QUALITY, SOUND, HEALTHY, VIGOROUS, WELL-BRANCHED, AND DENSELY FOLIATED, FREE OF DISEASE,INSECT PESTS, EGGS OR LARVAE, HEALTHY, WELL-FURNISHED ROOT SYSTEMS.16.CONFORM TO THE MEASUREMENTS SPECIFIED IN THE PLANT LIST. MEASUREMENTS SPECIFIED ARE THEMINIMUM ACCEPTABLE FOR EACH VARIETY. PLANTS THAT MEET THE REQUIREMENTS SPECIFIED IN THEITEMIZED PLANT LIST, BUT DO NOT POSSESS A NORMAL BALANCE BETWEEN HEIGHT AND SPREAD WILL NOTBE ACCEPTED. PLANTS FOR USE WHEN SYMMETRY IS REQUIRED, OR WHEN PLANTED IN FORMAL ROWS,SHALL BE MATCHED IN FORM AND SIZE AS NEARLY AS POSSIBLE. DO NOT PRUNE PRIOR TO DELIVERY.17.ALL PLANTS AND TREE TRUNKS SHALL BE MEASURED WHEN THE BRANCHES ARE IN THE NORMAL POSITION.DIMENSIONS FOR HEIGHT AND SPREAD AS CONTAINED HEREIN REFER TO THE MAIN BODY OF THE PLANT ANDNOT FROM BRANCH-TIP TO BRANCH-TOP. THE HEIGHT OF TREE TRUNKS NEED NOT BE AS SPECIFIED IF THEREQUIRED HEIGHT CAN BE OBTAINED BY PRUNING THE LOWER BRANCHES WITHOUT LEAVING UNSIGHTLYSCARS OR OTHERWISE DAMAGING THE TRUNK. DO NO PRUNING OF BRANCHES TO OBTAIN THE REQUIREDHEIGHT BEFORE THE PLANTS ARE DELIVERED TO THE SITE UNLESS SO APPROVED IN WRITING BY THECONSULTANT.18.ALL TREES MUST HAVE STRAIGHT TRUNKS WITH A SINGLE LEADER INTACT. THERE SHALL BE NO ABRASION OFTHE BARK, AND NO FRESH CUTS OF LIMBS OVER 30MM WHICH HAVE NOT COMPLETELY CALLOUSED OVER.PLANTS AND PLANTING - RELATED MATERIALS:19.TREE STAKES: DRESSED 4 SIDES 2"X2" TREATED FIR STAKES, LENGTHS AS REQUIRED.20.TREE TIES AND GUYWIRES: .10 DIAMETER GALVANIZED WIRE, COVERED WITH NEW BLACK GARDEN HOSE,2-PLY, REINFORCED AND AT LEAST 15/32" DIAMETER, OR APPROVED EQUAL.21.MULCH: PEAT MOSS22.FASTENERS: ALL FASTENERS TO BE HOT DIPPED GALVANIZED.23.PLANTING TABLETS: PROLONGED-RELEASE FERTILIZER TABLETS CONTAINING 20% NITROGEN, 10%PHOSPHORIC ACID, AND 5% POTASH (20-10-5). AGRIFORM OR PRE-APPROVED EQUIVALENT. STORE INWEATHERPROOF STORAGE SPACE.EXECUTION:24.TREE PITS ON GRADE: OF THE FOLLOWING MINIMUM STANDARD.24.1.TWO TIMES THE DIAMETER OF THE ROOT BALL WITH THE TREE IN THE CENTER OF THE PIT24.2.1 '-0" DEEPER THAN THE ROOT BALL FOR THE ENTIRE TREE PIT.25.PLANTING SEASON:25.1.PLANT ONLY DURING THE SEASON OR SEASONS WHICH ARE NORMAL FOR SUCH WORK DETERMINED BYWEATHER CONDITIONS AND AS APPROVED BY THE CONSULTANT.25.2.DO NOT PLANT DURING FREEZING ANO/OR ABNORMALLY HOT, DRY WEATHER.26.PLANT LAYOUT:26.1.LOCATES PLANTS ACCORDING TO THE PLANTING PLAN, ANO ACCORDING TO LOCATIONS DETERMINED BYTHE CONSULTANT, FOR APPROVAL OF PLANT LOCATIONS AND ORIENTATION. THE CONSULTANT MAYMAKE ADJUSTMENTS IN PLANT LOCATIONS AND ORIENTATION PRIOR TO PLANTING.26.2.STAKE LOCATION OF ALL MAJOR TREES FOR APPROVAL PRIOR TO POSITIONING. REQUEST CONSULTANTTO BE PRESENT DURING PLANTING OF MAJOR TREES TO ENSURE PROPER ORIENTATION AND LOCATION.27.PLANTING PROCEDURE:27.1.ALL PLANTS TO BE INSTALLED MAINTAINING ORIGINAL GRADES OF BASES AS IN THE NURSERY.27.2.BACKFILL AROUND THE ROOT BALL WITH PREPARED GROWING MEDIUM, TAMPING AND WATERING TOENSURE FIRM SUPPORT FOR THE PLANT, AND ELIMINATING AIR POCKETS AROUND THE ROOT BALL.28.FERTILIZER APPLICATION:28.1.PLACE PLANTING TABLETS AT THE FOLLOWING RATES IN THE PREPARED PLANTING HOLES. SPREAD THETABLETS IN EACH HOLE BEFORE PLANTING.PLANT SIZE/TABLET SIZETABLETSCONTAINER SIZEPER PLANTTREES21g1/25 CALIPER18 GAL TUB21G37 GAL POT21G35 GAL POT21G22 GAL POT21G11 GAL POT21G1OTHER SIZES AS PER MANUFACTURER'S RECOMMENDATIONS29.MULCHING: MULCH ALL SHRUB AND GROUNDCOVER AREAS TO A 2" DEPTH.30.GUYING AND STAKING30.1.GUY AND STAKE ALL TREES IMMEDIATELY AFTER PLANTING. PLANT MATERIAL NOT GUYED OR STAKEDIMMEDIATELY SHALL BE REPLACED IF DAMAGED.30.2.DRIVE THREE (3) STAKES PER TREE (EQUALLY SPACED AROUND THE TREE) VERTICALLY INTO THE GROUNDTO A DEPTH OF 2'-6" TO 3'-0"MM, IN SUCH A MANNER SO AS NOT TO INJURE THE ROOT OR ROOT BALL.30.3.FASTEN TREE TO THE CROTCH AND MIDWAY BETWEEN THE CROTCH AND THE GROUND WITHGALVANIZED WIRE PROTECTED BY HOSE.30.4.TREES TO STAND PLUMB UPON COMPLETION OF THIS OPERATION.31.PRUNING:31.1.PRUNE EACH TREE AND SHRUB PLANTED TO PRESERVE THE NATURAL CHARACTER OF THE PLANT IN AMANNER APPROPRIATE TO ITS PARTICULAR REQUIREMENT IN THE LANDSCAPE DESIGN. PRUNING INGENERAL SHALL BE HEAVIER ON COLLECTED THAN ON NURSERY-GROWN PLANTS. REMOVE ALL SOFTWOOD SUCKER GROWTH AND ALL BROKEN OR BADLY BRUISED BRANCHES WITH A CLEAN CUT.32.CLEAN UP:32.1.REMOVE FROM THE SITE ALL CANS, SURPLUS MATERIAL AND OTHER DEBRIS RESULTING FROM PLANTINGOPERATIONS.32.2.NEATLY DRESS AND FINISH ALL PLANTING BEDS AND FLUSH ALL WALKS AND PAVED AREAS CLEAN TO THESATISFACTION OF THE CONSULTANT AND THE OWNERLANDSCAPE MAINTENANCE GENERAL:33.ALL LANDSCAPE MAINTENANCE AND IRRIGATION SHALL BE BE MAINTAINED BY APPLICANT OR LANDOWNER,FOR THE LIFE OF THE DEVELOPMENT TO THE MINIMUM REQUIREMENTS OF THE LOCAL JURISDICTION. 11/9/21INFINIGYFROMZEROIOTNFIINGYthe solutions are endlessINFINIGYFROMZEROIOTNFIINGYthe solutions are endless2500 W. HIGGINS RD. SUITE 500 HOFFMAN ESTATES, IL 60169Phone: 847-648-4068 | Fax: 518-690-0793www.infinigy.comReviewed:Project Title:Submittal / RevisionRev.Dsg'dDateApproved:Date:Date:Project Number:DAPD11/09/21Drawing Scale:Date:11/09/21AS NOTEDCDSITE ADDRESS:29601 8TH AVE SWFEDERAL WAY, WA 98023L-3Prepared By:Prepared For:Engineer Stamp:Drawing Title:Drawing Number:UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS AVIOLATION OF APPLICABLE STATE AND/OR LOCAL LAWSSigned:Date:4106-A0001-C11/09/21AT&T SITE ID:SC2064FA LOCATION:15180626SITE NAME:REDONDO BEACHTHESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF INFINIGY AND AT&T ANDMAY NOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF INFINIGY AND AT&T.Carrier:11232 120TH AVE NE, SUITE 204KIRKLAND, WA 98033ISSUED FOR REVIEWINFINIGY ENGINEERING, PLLC2500 W HIGGINS RD, SUITE 500 HOFFMAN ESTATES, IL 60169PHONE: 847-648-4068 | FAX: 518-690-0793www.infinigy.comREVISED PER COMMENTSTJBDZA07/30/21B05/07/21REVISED PER COMMENTSTJB08/24/21CREVISED PER COMMENTSTJB10/04/21DREVISED PER COMMENTSTJB100% CONSTRUCTION DOCUMENTSTJB11/09/21011/02/21ESCALE:(OR)02'4'8'1/16"=1'-0" (11x17)1/8"=1'-0" (24x36)1LANDSCAPING PLANL-3CALLED NORTHPROPOSED 5'LANDSCAPE BUFFERLANDSCAPE BUFFER TOOPEN INTO EASEMENTFOR ACCESSPROPOSED MULCH WITHINLANDSCAPING BUFFERSYMBOLQUANTITYBOTANICAL/COMMON NAMELEGEND--21ALTERNATED RABBIT BRUSHAND RUSSIAN SAGECOMMON JUNIPER TREETREE TIES STRAP TYPE"GRO-STRAIGHT"TWO TIMESROOTBALL SIZE2 - 2" X 2" X 8' P.T.D.F. STAKE,CONSTRUCTION GRADEOPEN BURLAP ABOUT TRUNK.FOLD BACK AND UNDER.2" DEEP RAINWATER COLLECTIONBASIN. THOROUGHLY WATER IN.MULCH TO GRADE.3" BARK MULCH WHERE SPECIFIEDEXISTING SOILPREPARED PLANTING SOILDRIVE STAKES A MINIMUMOF 12" OF RESISTANCE.N.T.S.SCALE2LANDSCAPING DETAILL-3N.T.S.SCALE3LANDSCAPING DETAILL-3SET SHRUB TO SAMEGRADE AS NURSERYREMOVE TOP 1/3 BURLAP ABOUTROOT BALL. FOLD BACK ANDUNDER OR REMOVE.2" DEEP RAINWATER COLLECTIONBASIN. THOROUGHLY WATER IN.MULCH TO GRADE.3" BARK MULCH WHERE SPECIFIEDEXISTING SOILPREPARED PLANTING SOIL;MIN. 1'-0" GROWINGMEDIUM ON ALL SIDES150 SQ. FT. OF IMPERVIOUS SURFACES WITHINLEASE AREA, SEE 2/C-1.2 FOR DETAILSVARIES6'-0" MAX.LANDSCAPINGPLAN AND DETAILS5'-0"5'-0"