20-101386-Barrier Free Access Plan-04-09-2020-V1702 ALARMS17" MIN8" MIN6" MAX48" MIN19" MAX17" MIN30" MIN 40" MAX to bottom of mirror 34" MAX 29" MIN 27" MIN 9" MIN 703 SIGNAGE603 TOILET ROOMS905 STORAGE609 GRAB BARS continued308 & 309 REACH RANGES AND OPERABLE PARTS4" MAX.27" MIN.Detail80" MIN.Detail1/4" MAX.LOBBY1 21/4"-1/2"48" MIN.30"606 LAVATORIESDetail44" MAX 17" MAX.14" MINDetail(REFERENCE DETAILS)305 CLEAR FLOOR SPACE302/303 FLOOR SURFACES & CHANGES IN LEVEL307 PROTRUDING OBJECTS403 ACCESSIBLE ROUTE - WALKING SURFACES404 DOORSStandard Curb Ramp604 WATER CLOSETS & TOILET COMPARTMENTS605 - URINALSFlared sideAdjoining Slope ShallShall Have Detectable WarningsNot Exceed 1:20Ramp (1:12 Max. Slope) 36"minxIf x Is less than 48"Sides Shall Not Exceed 1:12Then The Slope Of The Flared1:10 Max. slope1:12 Max. slopeCurb Ramp Parallel to CurbDetailShall Have Detectable WarningsRamps (1:12 Max. Slope) Note : If Slope is 1:20 or less and contrasting color.and contrasting color.no contrasting color or textureNot Exceed 1:20Adjoining Slope ShallLocation of TypicalParking Access Aisle36" Min.36" min. if located in an alcove > 24" deep 74" MIN to top of mirror clear floor spaceMaximumReach DepthMaximumReach Height0.5"48"2"46"5"42"6"40"9"36"11"34"SEGMENT LENGTHless than or equal to:24"MINIMUMSEGMENT WIDTH32"36"greater than: 24"406 CURB RAMPS602 DRINKING FOUNTAINSANY AMOUNTDetail27" MAX.CLEAR WIDTH15"MINForward Approach5"MAX410 PLATFORM LIFTSMENInternational Symbolof AccessibilityLetter & numbers on signs shall have a widthto height ratio of between 3:5 & 1:1 anda stroke - width to height ratio between 1:5 & 1:10. Letters and numbers shall be raised1/32", upper case, sans serif or simple seriftype and shall be accompanied withgrade 2 Braille, raised characters shall be atleast 5/8" - 3" high plus 1/8" per foot of DetailMEN60" MAX ABOVE BASELINE OF HIGHEST CHARACTER 48" MAX 15" MIN Light switchThermostats, Etc.Convenience OutletsData, Tel., Etc.Detailviewing distance above 21 feet. 902 DINING SURFACES & WORK SURFACES804 KITCHENS AND KITCHENETTESANSI/ICC A117.1 303 - CHANGES IN LEVEL (REFERENCE DETAIL)A. Changes in level up to 1/4" may be vertical and without edge treatmentB. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2.ANSI/ICC A117.1 302.2 - CARPETA.Carpet provided on a floor surface shall be securely attached; have a firm pad or backing, or no pad; and have alevel loop, textured loop, level cut pile, or level cut/uncut pile texture. Maximum pile thickness shall be 1/2".Exposed edges of carpet shall be fastened to floor surfaces and have trim along the exposed edges.ANSI/ICC A117.1 302.3 - GRATINGSA. If gratings are located in walking surfaces or along accessible routes, then they shall have spaces no greater than1/2" wide in one direction.B. If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to thedominant direction of travel.ANSI/ICC A117.1 305.2 - SIZE AND APPROACHA. Minimum clear floor space for a wheelchair and occupant shall be 30" wide x 48" long. Clear floor space shall becentered on the element it serves.ANSI/ICC A117.1 307 - GENERALA. Objects projecting from walls (for example, telephones) with their leading edges between 27"-80" above thefinished floor shall protrude no more than 4" into walks, halls, corridors, passageways, or aisles. Freestandingobjects mounted on posts or pylons may overhang 12" maximum from 27"-80" above the ground or finishedfloor. Protruding objects shall not reduce the clear width of an accessible route or maneuvering space.ANSI/ICC A117.1 308 - HEIGHT (REFERENCE DETAIL)A.Unobstructed front approach - 48" max. to 15" min. A.F.F. Controls located in an alcove >24" deep must have36" clear floor width.B.Unobstructed side approach - 48" max. to 15" min. A.F.F. Controls located in an alcove >15" deep must have60" clear floor width.C.Electrical & communication system receptacles shall be mounted no less than 15" above the floor.ANSI/ICC A117.1 309 - OPERABLE PARTSOperable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of thewrist. The force required to activate operable parts shall be 5.0lbs maximum.IBC 1104 - LOCATIONA. At least one accessible route within the site shall be provided from public transportation stops, accessible parkingand accessible passenger loading zones, and public streets or sidewalks to the accessible building entranceserved.ANSI/ICC A117.1 403.5 - CLEAR WIDTHA. The minimum clear width shall be 32" at a point for a max. length of 24" and 36" continuously, per Table below.ANSI/ICC A117.1 406 - SLOPE (REFERENCE DETAIL)A. Slopes of curb ramps shall comply with 406B. Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb ramp, or accessible routeshall not exceed 1:20.ANSI/ICC A117.1 406.4 - WIDTH (REFERENCE DETAIL)A. The minimum width of a curb ramp shall be 36", exclusive of flared sides.ANSI/ICC A117.1 406.3 - SIDES OF CURB RAMPS (REFERENCE DETAIL)A. If a curb ramp is located where pedestrians must walk across the ramp or where it is not protected by handrailsor guardrails, it shall have flared sides; the maximum slope of the flare shall be 1:10IBC with WA STATE AMENDMENTS 1101.2.1 - CLEAR WIDTHA. Clear width of an accessible route shall comply with Table above. For exterior routes of travel, the minimum clearwidth shall be 44".ANSI/ICC A117.1 403.5.2 - PASSING SPACEA. If an accessible route is less than 60" in width, then passing spaces of at least 60"x60" shall be provided at 200'max. spacing.B. The minimum clear width for two wheelchairs to pass is 60"ANSI/ICC A117.1 307.2A. Accessible routes shall have 80" min. clear head room.ANSI/ICC A117.1 403.3 - SLOPEA. Running slope shall not exceed 1:20.B. Cross slope shall not exceed 1:48ANSI/ICC A117.1 406.10 - DIAGONAL CURB RAMPSA. If diagonal curb ramps have returned curbs or other well-defined edges, such edges shall be parallel to thedirection of pedestrian flow. The bottom of diagonal curb ramps shall have 48" minimum clear space outsideactive traffic lanes of the roadway. If diagonal curb ramps are provided at marked crossings, the 48" clear spaceshall be within the markings. If diagonal curb ramps have flared sides, they shall also have at least a 24" longsegment of straight curb located on each side of the curb ramp and within the marked crossing.ANSI/ICC A117.1 406.11 - ISLANDSA. Any raised islands in crossings shall be cut through level with the street or curb ramps at both sides and a levelarea at least 48" long and 36" minimum wide between the curb ramps in the part of the island intersected bythe crossings.ANSI/ICC A117.1 602.1 - GENERALA. Accessible drinking fountains shall comply with Sections 602 and 307.ANSI/ICC A117.1 602.2 - CLEAR FLOOR SPACEA. A clear floor space complying w/ Section 305, positioned for a forward approach to the drinking fountain,shall be provided. Knee & toe space complying with Section 306 shall be provided. The clear floor space shall becentered on the drinking fountain. EXCEPTIONS:1. Drinking fountains for standing persons.2. Drinking fountains primarily for children's use.3. In existing building, existing drinking fountains providing a parallel approach complying w/Section 305, centered on the drinking fountain shall be permitted.4. Where specifically permitted by the administrative authority, a parallel approach shall be permittedthat replace existing parallel approach drinking fountains.ANSI/ICC A117.1 602.3 - OPERABLE PARTSA.Operable parts shall comply with Section 309.ANSI/ICC A117.1 602.4 - SPOUT OUTLET HEIGHTA. Wheelchair accessible spout outlets shall be 36 inches max. aff. Standing person spout outlets shall be 38inches min. & 43 inches max. aff.ANSI/ICC A117.1 602.5 - SPOUT LOCATIONA.Spout shall be located 15 inches min. from the vertical support and 5 inches max. from the front edge of thedrinking fountain, including bumpers.ANSI/ICC A117.1 602.6 - WATER FLOWA.Spout shall provide a flow of water 4 inches min. in height. The angle of the water stream from spouts within 3inches of the front of the drinking fountain shall be 30 degrees max. and from spouts between 3 inches & 5inches from the front of the drinking fountain shall be 15 degrees max., measured horizontally relative to thefront face of the drinking fountain.ANSI/ICC A117.1 404.2.1 - DOUBLE - LEAF DOORWAYSA. Doorways with two independently operated leaves shall have at least one active leaf that meets therequirements in 404.2.2 and 404.2.3ANSI/ICC A117.1 404.2.2 - CLEAR WIDTHA. Doorways shall provide a clear opening of 32" minimum, with the door open 90°.1.Clear opening shall be measured between the face of the door and opposite stop.2.Openings more than 24" in depth shall provide a clear opening of 36" minimum.ANSI/ICC A117.1 404.2.3 - MANEUVERING CLEARANCES AT DOORSProvide level (1:48 max. slope) and clear maneuvering area at doors as follows:A.Front approach pull side - 60" min. width & 18" min. beside strike edgeFront approach push side - 48" min width & 0" beside strike edge(12" @ strike if door has both a closer and a latch)B. Hinge side approach pull side - 60" min. width; 36" min. beside strike edge or - 54" min. width; 42" min. besidestrike edgeHinge side approach push side - 42" min. width & 22" min. beside hinge edge(48"min. width if door has both a closer and a latch)C. Latch side approach pull side - 48" min. width and 24" min. beside strike edge(54"min. width if door has a closer)Latch side approach push side - 42" min. width and 24" min. beside strike edge(48"min. width if door has a closer)ANSI/ICC A117.1 404.2.4 - THRESHOLDS AT DOORWAYSA.Maximum threshold height: 1/2". Raised thresholds and floor level changes shall be beveled with a slope nogreater than 1:2ANSI/ICC A117.1 605 - URINALSA. Accessible urinals shall comply with Section 605.ANSI/ICC A117.1 605.2 - HEIGHT & DEPTH (REFERENCE DETAIL)A. Urinals shall be stall-type or wall hung with a tapered, elongated rim at 17" maximum above the finishedfloor. The rim shall extend a minimum of 1312" from the wall.ANSI/ICC A117.1- 605.3 - CLEAR FLOOR SPACE (REFERENCE DETAIL)A. A clear floor space 30" wide by 48" deep minimum shall be provided in front of urinal to allow forwardapproach.1. This space shall adjoin or overlap an accessible route.2. Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29"clearance between them.3. Urinals installed in alcoves deeper than 24" require a maneuvering area of at least 36"minimum wide, centered on fixture.ANSI/ICC A117.1 605.4 - FLUSH CONTROLS (REFERENCE DETAIL)Controls shall comply with ANSI/ICC A117.1 309 OPERABLE PARTSANSI/ICC A117.1 603.2.2 - DOORSA. Doors shall not swing into the clear floor space or clearance for any fixture.ANSI/ICC A117.1 603.2 - CLEARANCESA. The accessible fixtures and controls required shall be on an accessible route. An unobstructed turning spacecomplying with 304 shall be provided within an accessible toilet room. The clear floor space at fixtures andcontrols, the accessible route, and the turning space may overlap, however; the only turning space providedshall not be located within a stall.ANSI/ICC A117.1 603.3 & 606 - LAVATORIES AND MIRRORSA. If lavatories and mirrors are provided, then at least one of each shall comply with 603.3 & 606. Accessiblelavatories and mirrors shall not be located within toilet stalls unless other accessible lavatories and mirrors areprovided in the toilet room.ANSI/ICC A117.1 603.3 - MIRRORS (REFERENCE DETAIL)A. Mirrors shall be mounted with the bottom edge of the reflecting surface 40" maximum A.F.F. Mirrorsnot located above lavatoreis, sinks or counters shall be mounted with the bottom edge of the reflectingsurface 35" maximum above the floor.ANSI/ICC A117.1 603.6 - OPERABLE PARTSA.Operable parts on towel dispensers and hand dryers shall comply with Table below.ANSI/ICC A117.1 606.3 & 606.2 - HEIGHT & CLEARANCES (REFERENCE DETAILS)A. Lavatories shall be mounted with the rim or counter surface no higher than 34" above the finished floor.1. Lavatories shall extend 17" minimum from the wall.2. Clearance of 27" minimum shall be provided from the finished floor to bottom of apron.3. Knee clearance of 27" high minimum shall extend 8" minimum under the edge of the lavatory, 30" wideminimum, and 19" deep minimum.4. Toe clearance of 9" minimum shall be provided for the full depth of the lavatory.ANSI/ICC A117.1 606 - DEPTHA. Each sink shall be a maximum of 6-1/2" deep.ANSI/ICC A117.1 606.6 - EXPOSED PIPES AND SURFACESA.Hot / cold water and drain pipes under lavatories shall be insulated or otherwise configured to protect againstcontact.B.There shall be no sharp or abrasive surfaces under lavatories.ANSI/ICC A117.1 606.4 - FAUCETSA.Controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist.B.The force required to activate controls shall be no greater than 5 lb.C.Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs.D.If self-closing valves are used the faucet shall remain open for 10 seconds minimum.ANSI/ICC A117.1 905.2 - CLEAR FLOOR SPACEA clear floor space complying with Section 305 shall be provided.ANSI/ICC A117.1 905.3 - HEIGHTAccessible storage elements shall comply with at least one of the reach ranges specified in Section 308.ANSI/ICC A117.1 905.4 - OPERABLE PARTS Operable parts of storage facilities shall comply with Section 309.ANSI/ICC A117.1 609.8 - STRUCTURAL STRENGTHA.Grab bars and mounting devices shall meet the following requirements:609.8 Allowable stresses shall not be exceeded for materials used where a vertical or horizontal force of 250 lbs.is applied at any point on the grab bar, fastener mounting device, or supporting structure.1. Shear stress induced by application of 250 lb. shall be less than allowable shear stress for material used.If connection between grab bar and mounting bracket is considered to be fully restrained, then direct andtorsional shear stresses shall be totaled for the combined shear stress, which shall not exceed the allowableshear stress.2. Shear force induced in a fastener or mounting device from application of 250 lb. shall be less thanallowable lateral load of either the fastener or mounting device or the supporting structure, whichever isthe smaller allowable load.3. Tensile force induced in a fastener by a direct tension force of 250 lb. plus the maximum moment fromthe application of 250 lb. shall be less than the allowable withdrawal load between thefastener and the supporting structure.609.6 Grab bars shall not rotate within their fittings.ANSI/ICC A117.1 609.5 - ELIMINATING HAZARDSA.Grab bars and adjacent wall surfaces shall be free of sharp or abrasive surfaces. Edges shall be rounded.ANSI/ICC A117.1 702.1 - GENERALA. When required, visual alarms shall be provided in each of the following areas, as a minimum: rest rooms and anyother general usage areas (e.g., meeting rooms), hallways, lobbies, and any other area for common use.Accessible audible and visible alarms and notification appliances shall be installed in accordance with NFPA 72.NFPA 72 - AUDIBLE ALARMSA. If provided, audible alarms shall produce a sound that exceeds the prevailing equivalent sound level in the roomor space by at least 15 dba or exceeds any maximum sound level with a duration of 60 seconds by 5 dba,whichever is louder.B. Sound levels for alarm signals shall not exceed 120 dba.NFPA 72 - VISUAL ALARMSA. Visual alarm signal appliances shall be integrated into the building or facility alarm system. If single stationaudible alarms are provided then single station visual alarm signals shall be provided.Visual Alarm appliances shall have the following features: 1. The lamp shall be a xenon strobe type or equivalent. 2. The color shall be clear or nominal white (i.e. unfiltered or clear filtered white light).3. The maximum pulse duration shall be two-tenths of one second with a maximum duty cycle of 40%. (Thepulse duration is defined as the time interval between initial and final points of 10% of max signal)4. The intensity shall be a minimum of 75 candela.5. The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz6. The appliance shall be placed 80" above the highest floor level within the space or 6" below the ceiling,whichever is lower. a. In large rooms and spaces exceeding 100' across, without obstructions 6' above the finishedfloor, such as auditoriums, devices may be place around the perimeter, spaced a maximum 100' apart, in lieu ofsuspending appliances from the ceiling.7. In general, no place in any room or space shall be more than 50' from the signal (measured in ahorizontal plane).8. No place in common corridors or hallways shall be more than 50' from the signal.ANSI/ICC A117.1 410.1 - GENERALA. Platform lifts shall comply with Section 410 and ASME A18.1 listed in Section 105.2.6. Platform lifts shall not beattendant operated and shall provide unassisted entry and exit from the lift.ANSI/ICC A117.1 410.2 - LIFT ENTRYA.Lifts with doors or gates shall comply with Section 410.2.1. Lifts with ramps shall comply with Section 410.2.2.ANSI/ICC A117.1 410.2.1 - DOORS AND GATESA.Doors and gates shall be low energy power operated doors or gates complying with Section 404.3. Doors shallremain open for 20 seconds minimum. End door clear opening width shall be 32 inches minimum. Side doorclear opening width shall be 42inches minimum.Exception: Lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have selfclosing manual doors or gates.ANSI/ICC A117.1 410.2.2 - RAMPSA.End ramps shall be 32 inches minimum in width. Side ramps shall be 42 inches minimum in width.ANSI/ICC A117.1 410.3 - FLOOR SURFACESA.Floor surfaces of platform lifts shall comply with Section 302ANSI/ICC A117.1 410.4 - PLATFORM TO RUNWAY CLEARANCEA.The clearance between the platform sill and the edge of any runway landing shall be 1 1/4 inch maximumANSI/ICC A117.1 410.5 - CLEAR FLOOR SPACEA.Clear floor space of platform lifts shall comply with Section 305.ANSI/ICC A117.1 410.6 - OPERABLE PARTSA.Controls for platform lifts shall comply with Section 309.ANSI/ICC A117.1 902.2 - CLEAR FLOOR SPACEA. A clear floor space complying with Section 305, positioned for a forward approach, shall be provided. Knee andtoe clearance complying with Section 306 shall be provided.ANSI/ICC A117.1 902.4- HEIGHTA. The tops of accessible tables and counters shall be 28" minimum, and 34" maximum, above the finished floor.ANSI/ICC A117.1 804.5.6 - REFRIGERATOR/FREEZERCombination refrigerators and freezers shall have at least 50% of the freezer compartment shelves, including thebottom of the freezer 54 inches (1370mm) maximum above the floor when the shelves are installed at the maximumheights possible in the compartment. A clear floor space, positioned for a parallel approach to the space dedicatedto a refrigerator/freezer, shall be provided. The centerline of the clear floor space shall be offset 24 inches (610 mm)maximum from the centerline of the dedicated space.WHERE APPLICABLEA.Signs which designate permanent rooms and spaces shall comply with the requirements listed below for:1.Raised and Braille Characters, and Pictograms2.Finish and ContrastException: Employee name signs are not required to comply.WHERE APPLICABLEA. Signs which provide direction to, or information about, functional spaces of the building shall comply with therequirements listed below for: 1.Character Proportion2.Character Height3.Finish and ContrastException: Building directories, menus, and all other signs which are temporary are not required to comply.WHERE APPLICABLE (REFERENCE DETAIL)A.Element and spaces of accessible facilities which shall be identified by the International Symbol of Accessibilityare:1.Parking spaces designated as reserved for persons with disabilities.2.Accessible passenger loading zones.3. Accessible entrances when not all are accessible (inaccessible entrances shall have directional signage toindicate route to nearest accessible entrance).4.Accessible toilet and bathing facilities when not all are accessible.ANSI/ICC A117.1 703.2.4 - CHARACTER HEIGHT (REFERENCE DETAIL)Height: The uppecase letter "I" shall be used to determine the allowable height of all characters of a font and shallbe a minimum of 58" and 2" maximum.EXCEPTION: Where separate tactile and visual characters with the same information are provided, the height of thetactile upper case letter "I" shall be permitted to be 12" minimum.ANSI/ICC A117.1 703.2.5 - CHARACTER WIDTHA.Width: The uppercase letter "O" shall be used to determine the allowable width of all characters of a font, andshall be 55% min. and 110% max. of the height of the uppercase "I" of the font.404 DOORS continuedANSI/ICC A117.1 404.2.6 - DOOR HARDWAREA.Handles, pulls, latches, locks, and other operating devices shall have a shape that is easy to grasp with one handand does not require tight grasping, tight pinching, or twisting of the wrist to operate.1. Lever-operated mechanisms, push-type mechanisms, and U-shaped handles are acceptable designs.2. When sliding doors are fully open, operating hardware shall be exposed and usable from both sides.3. Hardware required for accessible door passage shall be mounted between 34" and 48" above finished floor.ANSI/ICC A117.1 404.2.7.1 - DOOR CLOSERSA.Door closers shall be adjusted so that from an open position of 90 degrees, the time required to move the doorto an open position of 12 degrees shall be 5 seconds minimum.ANSI/ICC A117.1 404.2.7.2 - SPRING HINGESA. Door spring hinges shall be adjusted so that from the open position of 70 degrees, the door shall move to theclosed position in 1.5 seconds minimum.ANSI/ICC A117.1 404.2.8 and IBC with WA STATE AMENDMENTS - DOOR OPENING FORCEA. The maximum force for pushing or pulling open doors shall be as follows:1. Fire doors shall have the minimum opening force allowable by the appropriate administrativeauthority.1.Other doorsa.Exterior hinged, sliding or folding door: 10.0 lb. max.b.Interior hinged doors: 5.0 lb. max.c.Interior sliding or folding doors: 5.0 lb. max.These forces do not apply to the force required to retract latch bolts or disengage other devices that may holdthe door in a closed position.Exception: Interior or exterior automatic doors complying with Section 404.3 of ICC A117.1.703 SIGNAGE continued502/503 PARKING AND PASSENGER LOADING ZONESANSI/ICC A117.1 502 - PARKING SPACESA. Accessible car parking spaces shall be 96" minimum in width. Van parking spaces shall be 132" minimum in width.EXCEPTION: Van parking spaces shall be permitted to be 96" minimum in width where the adjacent access aisleis 96" minimum in width.B. Parking access aisles shall be 60" wide. Van accessible access aisles shall be 96" wide.C. Surface slope shall not exceed 1:48 in all directions(Note : no built up curb ramp may be located in an accessible parking access aisle.)ANSI/ICC A117.1 502.7 - SIGNAGE (REFERENCE DETAIL)A. Each accessible parking space must have individual vertically mounted or suspended sign. Required van accessiblespaces must be designated. B. Characters and symbols on such signs shall be located 60" minimum above the ground.ANSI/ICC A117.1 503.5 - VERTICAL CLEARANCEA. Provide minimum vertical clearance of 114" at accessible passenger loading zones and along at least one vehicleaccess route from site entrances and exits.ANSI/ICC A117.1 503 - PASSENGER LOADING ZONEA. Passenger loading zones shall provide an access aisle at least 60" wide and 20 ft long adjacent and parallel to thevehicle pull-up space. If there are curbs between the access aisle and the vehicle pull-up space, then a curbramp complying with 4.7 shall be provided. Vehicle standing spaces and access aisles shall be level with surfaceslopes not exceeding 1:48 in all directions.604 WATER CLOSETS & TOILET COMPARTMENTS continued502/503 PARKING AND PASSENGER LOADING ZONES continuedDetailSET POST IN CONC.FINISH GRADEPRE-MANUF. SIGN 1'-6" 1'-6" 1/2"VANACCESSIBLEREQUIREDPERMITPARKINGSTATEDISABLED5'-0" MIN. TO BOTTOM OF SIGN 5"3"1'-0"NOTE: INSTALL SIGN AT ALL ACCESSIBLEPARKING STALLS. SPACES DESIGNATEDFOR VAN PARKING SHALL HAVEADDITIONAL SIGN "VAN ACCESSIBLE"MOUNTED BELOW. MOUNT ON WALL OFBLDG WHEN POSSIBLE.Rear Wall Grab Bar for Water Closet36" MIN.33"-36"on wide side 12"24"ANSI/ICC A117.1 604.7 - DISPENSERS (REFERENCE DETAIL)A. Toilet paper dispensers shall comply with Section 309.4 and 609.3. Where the dispenser is located above the grabbar, the outlet of the dispenser shall be located 24" min-36" max from the rear wall. Where the dispenser islocated below the grab bar, the outlet of the dispenser shall be located 24" min-42" max from the rear wall. Theoutlet of the dispenser shall comply with Table 603.6.1. Dispensers that control delivery or do not permit continuous paper flow shall not be used.ANSI/ICC A117.1 604.9 - WHEELCHAIR ACCESSIBLE COMPARTMENTSA. Wheelchair accessible compartments shall comply with Section 604.9. Toilet compartments shall comply withSection 604.9.2.1 or 604.9.2.2 as applicable.33"-36"42" MIN39"-41"39"-41"18" MIN 54" MIN903 BENCHESANSI/ICC A117.1 903.2 - CLEAR FLOOR SPACEA. a clear floor space complying with section 305, positioned for parallel approach to the bench seat shall beprovided.ANSI/ICC A117.1 903.3- SIZEA. Benches shall have seats 42" minimum in length and 20" minimum and 24" maximum in depth.ANSI/ICC A117.1 903.4 - BACK SUPPORTA. The bench shall provide for back support or shall be fixed to a wall. Back support shall be 42" minimum in lengthand shall extend from a point 2" maximum above the seat surface to a point 18" above the seat surface.Side Wall Grab Bar for Water Closet18" MIN24" MIN42" MAX12" MAX17"-19" 1 1/2" MIN 48" MAX 24" MIN12" MIN 36" MAXProtruding DispenserBelow Grab BarProtruding DispenserAbove Grab Bar18" MIN24" MIN42" MAXRecessed Dispenser48" MAX 36" MAXTHIS SHEET IS PROVIDED FOR YOUR CONVENIENCE. IT CONTAINS SELECTIONS FROM THE CURRENTACCESSIBILITY REFERENCED STANDARDS (2015 IBC CHAPTER 11 WITH WA STATE AMENDMENTS AND ANSI/ICCA117.1), BUT IS NOT INTENDED TO BE A COMPLETE OR EXHAUSTIVE COPY OF THE CURRENT ACCESSIBILITYSTANDARDS.39" MAX 2'-5" MIN 2'-10" 6'-3" 3'-10" 50" MAX 40" MAX 2'-5" MIN 2'-10" 36" MAX 38"-43" 6"OVERHEAD SIGNSA.CHARACTERS AND NUMBERS ON OVERHEAD SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCEFROM WHICH THEY ARE TO BE READ. 1. FOR SIGNS HIGHER THAN 70" A.F.F., CHARACTER SIZE SHALL BE 2" MINIMUM PLUS 18" PER FOOT OFVIEWING DISTANCE ABOVE 15 FEET.1.THE MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE LETTER "I".2.LOWER CASE LETTERS ARE PERMITTED.ANSI/ICC A117.1 703.3-703.5 - RAISED CHARACTERS, BRAILLE, & PICTOGRAMSA.Raised characters shall comply with section 703.3 and shall be duplicated in braille complying with section 703.4.B. Letter and numerals shall be raised 1/32", upper case, sans serif and shall be accompanied by grade 2Braille.1. Raised character height: 58" minimum to 3" plus 18" per foot of viewing distance above 21feet.2. Braille shall be contracted (grade 2); shall be located below title corresponding text.3. Pictograms shall be accompanied by the equivalent verbal description placed directlybelow the pictogram.1.The border dimension of the pictogram shall be 6" min. in height.ANSI/ICC A117.1 703.3.12 - FINISH AND CONTRASTA.Characters and their background shall have a nonglare finish. Characters shall contrast with their background,with either light characters on a dark background, or dark characters on a light background.ANSI/ICC A117.1 703.3.10 & 703.3.11 - MOUNTING LOCATION AND HEIGHT (REFERENCE DETAIL)A.Characters and their background shall have a nonglare finish. Characters shall contrast with their background,with either light characters on a dark background, or dark characters on a light background.B.Where a tactile sign is mounted next to a door, it shall be placed to the latch side of the door wherever possible.Where a tactile sign is placed adjacent a double door, the sign shall be to the right hand door. If there is no wallspace to the right, signs shall be placed on the nearest adjacent wall. Exception: Door mounted signs shall bepermitted on the push side on the doors with closers and without hold open devices.C.Raised characters shall be 48" minimum above the floor, measured to the baseline of the lowest raised characterand 60" maximum above the floor, measured to the baseline of the highest raised character.D.Mounting location for such signage shall be so that a person may approach within 3" of signage withoutencountering protruding objects or standing within the swing of a door.IBC with WA STATE AMENDMENTS 1101.2.6 - INTERNATIONAL SYMBOL OF ACCESSIBILITYA. Where the International Symbol of Accessibility is required, it shall be proportioned complying with ANSI/ICCA117.1 Figure 703.6.3.1. All interior and exterior signs depicting the International Symbol of Accessibility shall bewhite on a blue background.40" MAX 40" MAX 40" MAX 40" MAX 40" MAX 24" ADA 15" MEN 12" WOMEN 15" MIN 48" MAXTO HOOK5'-0"1'-6"2"2'-10"6'-6"to top R-WASTERECEPTACLER-TOILET SEATCOVER DISPENSERR-PAPER TOWELDISPENSER/ WASTERECEPTACLER-PAPER TOWELDISPENSERR-SANITARY NAPKINDISPENSERSOLIDPLASTICBENCHFULL LENGTHMIRRORSTAINLESS STEELSHELFHAT/COAT HOOKMOP/BROOMHOLDERS-ELECTRIC HANDDRYERLAVATORY MOUNTED INCOUNTERWALL MOUNTEDLAVATORYHAND SHOWER/24" SLIDE BAR17"-19"1'-6"3'-2" MIN 4'-0" MAXCONTROL AREA4"MAX15"MAX1'-6"3"-6"608.3.1 Rear Wall Grab Bar for Shower608.3.1 Side Wall Grab Bar for ShowerAUTOMATIC TELLER MACHINESANSI/ICC A117.1 305 - CLEAR FLOOR SPACEA.Floor space shall comply with Section 305 to allow a forward, parallel approach or both.ANSI/ICC A117.1 308 - HEIGHTA.Operable parts shall be placed within one or more of the reach ranges specified in Section 308, summarizedearlier in this sheet.is required505 HANDRAILSHandrail to extendhorizontally at top extension34" - 36"(1) TREAD DEPTH1'-0"Bottom rail to provide edgeprotectionHandrail to extend horizontallyat top and bottom extension34" - 36"If vertical rise is greater than 6"then bottom rail to provide edgeprotection1'-0"Handrail at StairHandrail at RampHandrail to extend with slope atbottom extension1'-0"4"Handrail Section1 1/4" to 2"1 1/2"12" MAX56" MIN. (WALL MOUNTED W.C.) 59" MIN. (FLOOR MOUNTED W.C.)Detail18"42" MIN.24" 60" MIN. 12"ANSI/ICC A117.1 604.3 - CLEARANCESA. Clear floor space for water closets not in stalls shall be provided as follows: Clearance around a water closetshall be 60" minimum in width, measured perpendicular from the sidewall. Clearance around the water closetshall be 56" minimum in depth, measured perpendicular from the rear wall. (Reference Detail)B. No door swings are allowed in clear floor area.ANSI/ICC A117.1 604.4 - HEIGHT (REFERENCE DETAIL)A. The height to the top of the toilet seat shall be 17" - 19" above floor.1. Seats shall not be sprung to return to a lifted position.IBC with WA STATE AMENDMENTS 1101.2.5 - FLUSH CONTROLSA. Hand operated flush controls shall comply with Section 309, except the maximum height abovethe floor shall be 44".6"MAX.12"MIN.6" MIN.6"MIN.TOILET PARTITION TOE CLEARANCE36" MIN.3"MAX.2 1/2""1 1/2"MAX.36" MIN. 15"-16"Shower Floor Plan / Seat609 GRAB BARSANSI/ICC A117.1 609.3.2 - SIZE AND SPACINGA.Diameter or width of gripping surface shall be 1-1/4" to 2", or the shape shall provide an equivalent grippingsurface.1.The space between grab bars and adjacent walls shall be 1-1/2"610 SEATSANSI/ICC A117.1 610.2 - SHOWER COMPARTMENT SEATSA.The height of the shower compartment seats shall be 17" minimum and 19" maximum above the bathroomfloor measured to the top of the seat.B.Allowable stresses shall not be exceeded for materials used where a vertical or horizontal force of 250pounds is applied at any point in the seat, fastener mounting device or support structure.4"MAX. 33"-36"ANSI/ICC A117.1 604.5 - GRAB BARS (REFERENCE DETAILS)A. For water closets not located in toilet stalls, the following grab bars shall be provided, 33" - 36" above thefinish floor:1. Side wall horizontal: 42" in length minimum, 12" max from rear wall, extending 54" min. from rear wall2. Side wall vertical: 18" in length minimum, bottom of bar located 39" min/41" max. above the floor, centerline39" min/41" max from rear wall3. Back wall: 36" in length minimum, extend from centerline of water closet 12" min. on side closest to the wall,24" min. on transfer side.ANSI/ICC A117.1 604.6 - FLUSH CONTROLSA. Flush controls shall be hand operated or automatic, and located on the open side of the water closet. Handoperated flush controls shall comply with Section 309.ANSI/ICC A117.1 604.7 - DISPENSERS - REFERENCE DETAIL. THE OUTLET OF THE DISPENSER SHALL COMPLY WITH TABLE 603.64" DIA. STEEL SET POST IN CONC.FINISH GRADEPRE-MANUF. SIGN GALVANIZED MOUNTING BOLTS1'-6" 1'-6" 1/2"NOPARKING5'-0" MIN. TO BOTTOM OF SIGN 5"3"1'-0"POST W/ CAP4" DIA. STEEL POST W/ CAPDetailNOTE: INSTALL SIGN AT THE HEAD OFEACH ACCESS AISLE LOCATED ADJACENTTO AN ACCESSIBLE PARKING SPACE.Nelco Architecture, Inc.Phone:Suite 1300Seattle, WA 98101(206) 408-85001200 Fifth Ave.WWW.NELSONWORLDWIDE.COM            Proj. No:Reviewed By:SEAL:CITY STAMP:IRGMS/PM IRG GREENLINEBUILDING AWEYERHAEUSER WAYS SFEDERAL WAY, WA 98001CR.00180070.000 CLIENT:PROJECT:11111 SANTA MONICA BLVD.SUITE 800LOS ANGELES, CA 90025Date:No:Description:Permit Submittal02/05/2020ACCESSIBILITYGUIDELINESAN-2 4" WIDE CURB@ BACK OF RAMPACCESSIBLE PARKINGSIGNAGE SEE PLANFOR LOCATIONS5'-0"MAX 1:12SLOPE UP18BA0.3A0.318A5'-0" MIN.MAX 1:48SLOPE DNNOTE:SLOPE SHALL BE1:12 MAX. &CROSS SLOPESHALL BE 1:48MAX., PER IBCSECTION 1012ACCESSIBLE 8'-0" @VAN19ACCESSIBLE RAMPWHEEL STOP WHERE SHOWNON SITE PLANPROVIDE DETECTABLE WARNING TEXTURE PER CODE,TYPICAL ALL WHEELCHAIR RAMPSAB5'-0"CONCRETE SIDEWALKASPHALT PAVING6"MAX.NOTE:CURB RAMP VERTICAL RISE SHALL BE 6"MAX., PER IBC SECTION 101218ACCESSIBLE RAMPSLOPE CONCRETEPAINT EXPOSED SURFACECONCRETE FOOTING1'-6" MIN.6"2'-6"SLABCONCRETE SLAB6"∅ STEEL PIPE FILLED W/ CONCRETE @STATIONARY LOCATIONS, (GALV. PIPE @ EXTERIORLOCATIONS)4'-0"14PIPE BOLLARDSTATE3"1'-6" 5'-0" MIN.REQUIREDPRE-MANUF. SIGN SET POST IN CONC.4" DIA. STEEL POST W/ CAP1'-6"VANACCESSIBLEFINISH GRADEGALVANIZED MOUNTING BOLTSDISABLEDPARKINGPERMIT5"1/2"NOTE: INSTALL SIGN AT ALL ACCESSIBLE PARKING STALLS.SPACES DESIGNATED FOR VAN PARKING SHALL HAVEADDITIONAL SIGN "VAN ACCESSIBLE" MOUNTED BELOW.1'-0"13ACCESSIBLE PARKING SIGNBUILDINGINTERIORCONCRETE RAMPBUILDINGEXTERIORINTERIOR FIN FLR+/-4'-0"EXISTING GRADE0'-0"CONCRETE LANDING+/- 53'-0"2'-6" 4'-0"3'-6"PIPE BOLLARD948" HIGH DRIVE UP RAMPSTART CONC GUARD RAIL MAX SLOPE: 1:123'-6"CONCRETE RETAINING WALL BEYONDPANEL6"BUILDINGINTERIORCONCRETE RAMPBUILDINGEXTERIORINTERIOR FIN FLR+/-4'-0"EXISTING GRADE0'-0"CONCRETE LANDING+/- 53'-0"2'-6" 4'-0"3'-6" START CONC GUARD RAIL MAX SLOPE: 1:12CONC PANEL3'-6"CONCRETE RETAINING WALL BEYOND1'-0"JOINT, PER STRUCTURAL.6" 3"WEEP HOLE TYP. AT 4'-0" O.C.2'-0"ASPHALT PAVINGROCK BASECONTRACTOR OPTION.STEEL TIE BARS @ 1 FT. EA. SIDE OFEVERY JOINT OR USE AN ADHESIVECONCRETE WHEEL STOP17WHEEL STOPDUMPSTERRECYCLE BINSCHAIN-LINK FENCE WITHPRIVACY SLATS & LOCKINGBOLT & PAD LOCK HASPTILT UP CONCRETE PANEL PERSTRUCTURALPRIVACY SLATS WITHINCHAIN-LINK FENCEVERTICAL JOINTCANE BOLT W/ SLEEVECONCRETE TILT-UP PANEL10'-6"15'-11"7'-0"CONCRETE TILT-UP PANELCONCRETE TILT-UP PANELABCGRADENOTE:ALL TILT-UP CONCRETE PANELS TO BE PAINTEDPNT-1.15TRASH ENCLOSURE4'-2"PRE-ENG. MTL. STAIR23'-0"1'-0" 6 TREADS @11"= 5'-6"1'-0"1'-0"4'-0" CLR6"HANDRAIL AT 36"GUARDRAIL AT 42"PLAN AT TYP.30"x48" AREA FOR RESCUE ASSISTANCE W/IDENTIFICATION SIGNAGE PER IBC SECTION 1007.6.1AND 1007.6.5 (WHERE NOTED AS AN EXIT)6"∅ x 4'-0" HT. CONC. FILLED GALV.PIPE BOLLARD, SEE DETAIL 14/A0.31'-0"5'-0"5'-3"6PRE-ENG. METAL STAIR3'-6"4'-0"LANDING SUPPORT ANGLESSTEEL STRINGERSTEEL CLIP ANGLE2"∅ GALVANIZED STEEL PIPEWELD & GRIND SMOOTH1-1/2"∅ ROUND STEEL HANDRAIL7" MAX EQ 3'-6" 3'-0"ELEVATIONCOLUMN @ CORNER OF LANDING21" MAX 21" MAX NOTE:SEE EXTERIOR METAL FINISHSPECIFICATIONS.OPEN STEEL GRATE TREADS AND LANDING1/4" x 12" AND1/4" STEEL RISERSMAX. LEADING EDGE RADIUS @STAIR: 1/2" PER IBC 1011.5.56"∅ x 4'-0" HT.CONC. FILLED SEE DETAIL 14/A0.3GALV. PIPE BOLLARD,HANDRAIL RETURN5'-0" MIN CONCRETE LANDING ATDOORS3PLAN AT DOOR LANDING5'-0"ALIGN WITH EDGE OFPANELRISER WHERE OCCURSHANDRAIL @ CONCRETE PANEL811" MIN7" MAX CONCRETE STAIRS WITH 12" RADIUS NOSE,TAPERED RISERS, NON-SLIP BROOM FINISH ANDGROOVED DETECTABLE WARNING AT TREADEDGES1 1/2" DIA. PIPE RAILING, EACH SIDE OF STAIRAND AT CENTER OF STAIR WHERE SHOWN, WELDAND GRIND SMOOTH, TYPICAL1" NOSING12"12"SLEEVE AND GROUT POSTS INTOCONCRETEMAX SLOPE1:204CONCRETE STAIR SECTIONLINE OF ADJACENT GRADE BEYOND2'-10"GUARDRAIL WHERE OCCURSPER PLAN3'-6"CONCRETE STAIR TREAD106'-6" (2) 11" TREADS7STAIRS @ DOOR LANDINGCONCRETE24"12" 36" 24" 7" MAX. RISERS 42" HIGH 1-1/2" DIA.GUARDRAIL SEE 4/A0.31-1/2" DIA. GUARDRAILSEE 4/A0.3Nelco Architecture, Inc.Phone:Suite 1300Seattle, WA 98101(206) 408-85001200 Fifth Ave.WWW.NELSONWORLDWIDE.COM            Proj. No:Reviewed By:SEAL:CITY STAMP:IRGMS/PM IRG GREENLINEBUILDING AWEYERHAEUSER WAYS SFEDERAL WAY, WA 98001CR.00180070.000 CLIENT:PROJECT:11111 SANTA MONICA BLVD.SUITE 800LOS ANGELES, CA 90025Date:No:Description:Permit Submittal02/05/2020EXTERIOR METAL FINISH SPECS:ALL EXTERIOR METALS: STRINGERS, PANS, SIGN PIPES, TREAD/RISERS, PIPE RAILINGS,ANGLES, BOLLARDS, ETC. TO BE GALVANIZED (ALUMINUM WINDOWS SYSTEMS SPECIFIED ELSEWHERE.)BOLLARDS: PAINT, SAFETY YELLOWSTAIRS: GALVANIZEDRAILINGS: GALVANIZEDNelco Architecture, Inc.Phone:Suite 1300Seattle, WA 98101(206) 408-85001200 Fifth Ave.WWW.NELSONWORLDWIDE.COM            Proj. No:Reviewed By:SEAL:CITY STAMP:IRGMS/PM IRG GREENLINEBUILDING AWEYERHAEUSER WAYS SFEDERAL WAY, WA 98001CR.00180070.000 CLIENT:PROJECT:11111 SANTA MONICA BLVD.SUITE 800LOS ANGELES, CA 90025Date:No:Description:Permit Submittal02/05/202010A0.3SITE DETAILSA0.3