Loading...
21-100325-Floor Plan-01-29-2021-V1GAS360'-0" OVERALL50'-0"50'-0"50'-0"50'-0"50'-0"ABCDEFGH50'-0"60'-0"679'-6" OVERALL 50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"25'-3"39'-9"50'-0"50'-0"50'-0"22'-0"39'-9"25'-3"27'-6"1234567891011121314152.513.5Nelco Architecture, Inc.Phone:Suite 1300Seattle, WA 98101(206) 408-85001200 Fifth Ave.WWW.NELSONWORLDWIDE.COM Proj. No:Reviewed By:SEAL:CITY STAMP:IRGMS/PC IRG GREENLINEBUILDING BWEYERHAEUSER WAYS SFEDERAL WAY, WA 9800120.0003368.000 CLIENT:PROJECT:11111 SANTA MONICA BLVD.SUITE 800LOS ANGELES, CA 90025Date:No:Description:ISSUED FOR PERMIT01/29/20211.ALL WALLS TO BE TILT-UP CONC PANEL, U.O.N.2.DOOR SYMBOL KEY: SEE A6.1 FOR DOOR SCHEDULE3.ELECTRICAL DESIGN BUILD TO MEET WSEC C4054.PJ = PANEL JOINT, SEE DETAIL 1/A8.15.PARTITION TYPE SEE SHEET A6.16.DOORS INTO ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITHA PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL ROOM" ORSIMILAR WORDING.7.FIRE PROTECTION EQUIPMENT ROOMS CONTAINING SPRINKLER RISERS,FACP, OR OTHER SUPPRESSION OR CONTROL ELEMENTS SHALL BEIDENTIFIED WITH APPROVED SIGNS; SIGNS SHALL BE CONSTRUCTED OFDURABLE MATERIALS, PERMANENTLY INSTALLED AND READILY VISIBLE PERIFC 509.1GENERAL NOTES#XLEGENDLOCATION OF UNDERSLAB VAPOR BARRIER1.PAINTED TILT-UP CONCRETE PANEL, PAINT EXTERIOR PER EXTERIORELEVATIONS, TYP. PAINT INTERIOR OF PANELS WHITE.2.REINFORCED CONCRETE SLAB, TYP. SEE STRUCTURAL.3.GRAY PRIMED TUBE STEEL COLUMN, TYP. SEE STRUCTURAL. PAINT COLUMNSAFETY YELLOW TO 12' AFF.4.NOT USED5.SCUPPER WITH DOWNSPOUT PER EXTERIOR ELEVATIONS.6.UNDER-SLAB SANITARY SEWER LINE, SEE CIVIL FOR SIZE ANDCONTINUATION. CAP AS REQUIRED.7.PIPE BOLLARD, PER DETAIL 14/A0.38.ANODIZED ALUMINUM STOREFRONT SYSTEM PER EXTERIOR ELEVATIONS.9.ELECTRICAL PANELS PER DESIGN/BUILD ELECTRICAL.10.FIRE SPRINKLER RISER LOCATION INTO BUILDING, SEE CIVIL.11.ROOF ACCESS LADDER TO PLATFORM ABOVE, SEE DETAIL 17/A8.112.ROOF ACCESS LADDER ABOVE, SEE DETAIL 17/A8.113.ROOF ACCESS HATCH ABOVE, SEE ROOF PLAN AND DETAIL 16/A8.114.SLOPE CONCRETE FLOOR AT 1/4" PER FOOT TO FLOOR DRAIN, COORDINATEWITH DESIGN BUILD CONTRACTOR FOR LOCATION.15.STUB DOMESTIC WATER LINE INTO BUILDING, CAP AS REQUIRED. SEE CIVILFOR CONTINUATION.16.INTERIOR ROOF DRAIN TIE INTO STORM DRAIN. OVERFLOW DRAIN TO SPILLABOVE GRADE.17.DESIGNATED STRIPED INTERNAL RECYCLING/GARBAGE COLLECTION POINT,500 S.F.18.STEEL TRELLIS. SEE A2.10 PLAN FOR DIMENSIONS.19.STEEL CANOPY PER ELEVATIONS AND DETAIL 9/A8.1.20.TILT-UP PANEL ABOVEKEY NOTESXOVERALL FLOOR PLANA2.01" = 50'-0"OVERALL FLOOR PLAN1A2.01A2.11A2.21A2.3WAREHOUSE100FIRE SPRINKLERROOM201ELECTRICALROOM2001A3.21A3.31A3.12A3.14A3.14A3.1OPP.3A3.1SIM. 22'-6"25'-0"22'-6"25'-0"25'-0"22'-6"22'-6"25'-0"9'-0"2'-0" OVERLAP 3'-4"R.O.9'-0"2'-0" OVERLAP3'-4"R.O. EQEQEQEQEQEQ 67891050'-0"50'-0"50'-0"50'-0" 679'-6" OVERALL 360'-0" OVERALL60'-0"50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"HCDEFGABNelco Architecture, Inc.Phone:Suite 1300Seattle, WA 98101(206) 408-85001200 Fifth Ave.WWW.NELSONWORLDWIDE.COM Proj. No:Reviewed By:SEAL:CITY STAMP:IRGMS/PC IRG GREENLINEBUILDING BWEYERHAEUSER WAYS SFEDERAL WAY, WA 9800120.0003368.000 CLIENT:PROJECT:11111 SANTA MONICA BLVD.SUITE 800LOS ANGELES, CA 90025Date:No:Description:ISSUED FOR PERMIT01/29/20211.ALL WALLS TO BE TILT-UP CONC PANEL, U.O.N.2.DOOR SYMBOL KEY: SEE A6.1 FOR DOOR SCHEDULE3.ELECTRICAL DESIGN BUILD TO MEET WSEC C4054.PJ = PANEL JOINT, SEE DETAIL 1/A8.15.PARTITION TYPE SEE SHEET A6.16.DOORS INTO ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITHA PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL ROOM" ORSIMILAR WORDING.7.FIRE PROTECTION EQUIPMENT ROOMS CONTAINING SPRINKLER RISERS,FACP, OR OTHER SUPPRESSION OR CONTROL ELEMENTS SHALL BEIDENTIFIED WITH APPROVED SIGNS; SIGNS SHALL BE CONSTRUCTED OFDURABLE MATERIALS, PERMANENTLY INSTALLED AND READILY VISIBLE PERIFC 509.1GENERAL NOTES#XLEGENDLOCATION OF UNDERSLAB VAPOR BARRIER1.PAINTED TILT-UP CONCRETE PANEL, PAINT EXTERIOR PER EXTERIORELEVATIONS, TYP. PAINT INTERIOR OF PANELS WHITE.2.REINFORCED CONCRETE SLAB, TYP. SEE STRUCTURAL.3.GRAY PRIMED TUBE STEEL COLUMN, TYP. SEE STRUCTURAL. PAINT COLUMNSAFETY YELLOW TO 12' AFF.4.NOT USED5.SCUPPER WITH DOWNSPOUT PER EXTERIOR ELEVATIONS.6.UNDER-SLAB SANITARY SEWER LINE, SEE CIVIL FOR SIZE ANDCONTINUATION. CAP AS REQUIRED.7.PIPE BOLLARD, PER DETAIL 14/A0.38.ANODIZED ALUMINUM STOREFRONT SYSTEM PER EXTERIOR ELEVATIONS.9.ELECTRICAL PANELS PER DESIGN/BUILD ELECTRICAL.10.FIRE SPRINKLER RISER LOCATION INTO BUILDING, SEE CIVIL.11.ROOF ACCESS LADDER TO PLATFORM ABOVE, SEE DETAIL 17/A8.112.ROOF ACCESS LADDER ABOVE, SEE DETAIL 17/A8.113.ROOF ACCESS HATCH ABOVE, SEE ROOF PLAN AND DETAIL 16/A8.114.SLOPE CONCRETE FLOOR AT 1/4" PER FOOT TO FLOOR DRAIN, COORDINATEWITH DESIGN BUILD CONTRACTOR FOR LOCATION.15.STUB DOMESTIC WATER LINE INTO BUILDING, CAP AS REQUIRED. SEE CIVILFOR CONTINUATION.16.INTERIOR ROOF DRAIN TIE INTO STORM DRAIN. OVERFLOW DRAIN TO SPILLABOVE GRADE.17.DESIGNATED STRIPED INTERNAL RECYCLING/GARBAGE COLLECTION POINT,500 S.F.18.STEEL TRELLIS. SEE A2.10 PLAN FOR DIMENSIONS.19.STEEL CANOPY PER ELEVATIONS AND DETAIL 9/A8.1.20.TILT-UP PANEL ABOVEKEY NOTESXKEY PLAN6A2.1A2.3A2.210MATCH LINEPARTIAL FLOOR PLANA2.21/16" = 1'-0"PARTIAL FLOOR PLAN1A2.21WAREHOUSE100PJ 6123TYPMATCH LINE103104127129130131132133134135136137138139140141142PJ PJ PJ PJ PJ PJPJ PJPJPJPJPJPJPJ PJ 5TYP16TYP111128SEE SHEET A2.1SEE SHEET A2.311A2.4 25'-0"22'-6"22'-6"25'-0"22'-6"9'-0"2'-0" OVERLAP3'-4"R.O.23'-9"23'-9"23'-9"23'-9"23'-9"23'-9"23'-9"9'-0"3'-4"R.O.9'-0"3'-4"R.O.2'-0" OVERLAP2'-0" OVERLAP25'-0"25'-0"23'-9"23'-9"EQEQEQEQ AAAAAAAAAAAAAAA AAAAAA AAA AAA AAAAAAAAA AAAAAAAAAAAAAAA AAAAAAAAAAAAAAAE002 E002E002AAAE00210111213141513.550'-0"50'-0"50'-0"27'-6"39'-9"25'-3"360'-0" OVERALL60'-0"50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"HCDEFGABNelco Architecture, Inc.Phone:Suite 1300Seattle, WA 98101(206) 408-85001200 Fifth Ave.WWW.NELSONWORLDWIDE.COM Proj. No:Reviewed By:SEAL:CITY STAMP:IRGMS/PC IRG GREENLINEBUILDING BWEYERHAEUSER WAYS SFEDERAL WAY, WA 9800120.0003368.000 CLIENT:PROJECT:11111 SANTA MONICA BLVD.SUITE 800LOS ANGELES, CA 90025Date:No:Description:ISSUED FOR PERMIT01/29/20211.ALL WALLS TO BE TILT-UP CONC PANEL, U.O.N.2.DOOR SYMBOL KEY: SEE A6.1 FOR DOOR SCHEDULE3.ELECTRICAL DESIGN BUILD TO MEET WSEC C4054.PJ = PANEL JOINT, SEE DETAIL 1/A8.15.PARTITION TYPE SEE SHEET A6.16.DOORS INTO ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITHA PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL ROOM" ORSIMILAR WORDING.7.FIRE PROTECTION EQUIPMENT ROOMS CONTAINING SPRINKLER RISERS,FACP, OR OTHER SUPPRESSION OR CONTROL ELEMENTS SHALL BEIDENTIFIED WITH APPROVED SIGNS; SIGNS SHALL BE CONSTRUCTED OFDURABLE MATERIALS, PERMANENTLY INSTALLED AND READILY VISIBLE PERIFC 509.1GENERAL NOTES#XLEGENDLOCATION OF UNDERSLAB VAPOR BARRIER1.PAINTED TILT-UP CONCRETE PANEL, PAINT EXTERIOR PER EXTERIORELEVATIONS, TYP. PAINT INTERIOR OF PANELS WHITE.2.REINFORCED CONCRETE SLAB, TYP. SEE STRUCTURAL.3.GRAY PRIMED TUBE STEEL COLUMN, TYP. SEE STRUCTURAL. PAINT COLUMNSAFETY YELLOW TO 12' AFF.4.NOT USED5.SCUPPER WITH DOWNSPOUT PER EXTERIOR ELEVATIONS.6.UNDER-SLAB SANITARY SEWER LINE, SEE CIVIL FOR SIZE ANDCONTINUATION. CAP AS REQUIRED.7.PIPE BOLLARD, PER DETAIL 14/A0.38.ANODIZED ALUMINUM STOREFRONT SYSTEM PER EXTERIOR ELEVATIONS.9.ELECTRICAL PANELS PER DESIGN/BUILD ELECTRICAL.10.FIRE SPRINKLER RISER LOCATION INTO BUILDING, SEE CIVIL.11.ROOF ACCESS LADDER TO PLATFORM ABOVE, SEE DETAIL 17/A8.112.ROOF ACCESS LADDER ABOVE, SEE DETAIL 17/A8.113.ROOF ACCESS HATCH ABOVE, SEE ROOF PLAN AND DETAIL 16/A8.114.SLOPE CONCRETE FLOOR AT 1/4" PER FOOT TO FLOOR DRAIN, COORDINATEWITH DESIGN BUILD CONTRACTOR FOR LOCATION.15.STUB DOMESTIC WATER LINE INTO BUILDING, CAP AS REQUIRED. SEE CIVILFOR CONTINUATION.16.INTERIOR ROOF DRAIN TIE INTO STORM DRAIN. OVERFLOW DRAIN TO SPILLABOVE GRADE.17.DESIGNATED STRIPED INTERNAL RECYCLING/GARBAGE COLLECTION POINT,500 S.F.18.STEEL TRELLIS. SEE A2.10 PLAN FOR DIMENSIONS.19.STEEL CANOPY PER ELEVATIONS AND DETAIL 9/A8.1.20.TILT-UP PANEL ABOVEKEY NOTESXKEY PLAN6A2.1A2.3A2.210PARTIAL FLOOR PLANA2.31/16" = 1'-0"PARTIAL FLOOR PLAN1A2.31WAREHOUSE1002A2.5PJ6 123TYPMATCH LINE100101102144145146147148149150151152153154155156157158159160PJPJPJPJPJPJPJPJPJ PJPJPJPJPJPJPJPJPJPJPJ PJ PJ PJPJ5TYP1116TYP16TYP17PJ1 11143PJPJ SEE SHEET A2.21A2.5PJ1A2.4 4'-6"7'-0"4'-6"9'-9"13'-0"13'-0"3'-0"3'-0"5'-3"2'-9"3'-0"2'-9"2'-9"8'-0"12'-9"21'-6"32'-0"ABCDEFG360'-0" OVERALL50'-0"50'-0"50'-0"50'-0"60'-0"50'-0"50'-0"50'-0"50'-0"50'-0"H50'-0"1234567891011121314152.513.522'-0"39'-9"25'-3" 679'-6" OVERALL 50'-0"50'-0"50'-0"50'-0"50'-0"27'-6"39'-9"25'-3"50'-0"21'-3" 53'-6" 40'-0"50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"50'-0"60'-0"35'-3"59'-9"50'-0"50'-0"70'-0"44'-2 3/4"40'-0"60'-0"40'-0"80'-0"44'-0"31'-0"45'-0"50'-0"50'-0"50'-0"55'-0"30'-0"31'-5 1/4"H232.522'-0"25'-3"H153'-0"10'-0"10'-0"10'-0"10'-0"3'-0"5'-0"5'-0"5'-0"5'-0"5'-0"2'-0"3'-0"10'-0"5'-0"18'-0"5'-0"2'-9"34'-9"46'-0"GENERAL NOTESKEY NOTES1.TPO ROOFING MEMBRANE, 60 MIL., COLOR: WHITE, TYP.2.48" X 96" SKYLIGHT, PROVIDE CRICKETS AS REQUIRED, TYP., SEE DETAIL15/A8.1.3.PARAPET WITH METAL COPING, PER EXTERIOR ELEVATIONS, SEE DETAIL13/A8.1.4.METAL COPING PER EXTERIOR ELEVATIONS, TYP. SEE DETAIL 12/A8.1.5.SCUPPER WITH DOWNSPOUT, TYP., SEE EXTERIOR ELEVATIONS. SEE DETAIL8/A8.1 & 11/A8.1.6.48" X 48" ROOF ACCESS HATCH PER DETAIL 16/A8.17.PRE-PRIMED METAL CANOPY, SEE ELEVATIONS FOR PAINT COLOR & DETAIL9/A8.1.8.PRE-PRIMED STEEL CANOPY WITH TIE RODS, PER STRUCTURAL. SEEEXTERIOR ELEVATIONS FOR PAINT COLOR.9.STEEL DECK PER STRUCTURAL, PAINT TO MATCH ADJACENT CANOPY STRUCTURE. SLOPE AT 1/4" PER 1'-0" TOWARD GUTTER.10.PRE-PRIMED STEEL ACCENT CHANNEL TYP., PER STRUCTURAL. SEE EXTERIORELEVATIONS FOR PAINT COLOR.11.SURFACE MOUNTED LIGHT FIXTURE, PER ELECTRICAL DESIGN BUILD.CENTER IN CANOPY.12.SHEET METAL GUTTER, PAINT TO MATCH ADJACENT CANOPY STRUCTURE.SLOPE TOWARD DOWNSPOUT.13.TIGHTLINED ROOF DRAIN WITH OVERFLOW DRAIN, DAYLIGHT OVERFLOW1'-0" ABOVE FINISHED FLOOR. SEE EXTERIOR ELEVATIONS. SEE DETAIL5/A8.2.14.METAL STANDING SEAM ROOF, ABOVE.1.NO CONDUIT ON ROOF2.ALL COMPONENTS FOR THE ROOF DRAINAGE SYSTEM SHALL BE SIZEDBASED ON A STORM OF 60 MINUTES DURATION AND 100 YEAR RETURNPERIOD PER UPC 1101.123.ALL ROOF MATERIALS SHALL COMPLY W/ THE STANDARDS AS SPECIFIED INTABLE 1507.10.2 OF THE 2015 IBC AND SHALL HAVE A FIRE CLASSIFICATION"X" PER TABLE 1505.1 OF THE 2015 IBC4.ALL ROOF DRAINS SHALL COMPLY WITH UPC 1101.2. ALL STORM DRAINSSHALL PROVIDE CLEAN OUTS IN CONFORMANCE WITH UPC 1101.3.XOVERALL ROOF PLANA2.101/8"=1'-0"ENLARGED CANOPY PLAN3A2.101" = 50'-0"OVERALL ROOF PLAN1A2.10Nelco Architecture, Inc.Phone:Suite 1300Seattle, WA 98101(206) 408-85001200 Fifth Ave.WWW.NELSONWORLDWIDE.COM Proj. No:Reviewed By:SEAL:CITY STAMP:IRGMS/PC IRG GREENLINEBUILDING BWEYERHAEUSER WAYS SFEDERAL WAY, WA 9800120.0003368.000 CLIENT:PROJECT:11111 SANTA MONICA BLVD.SUITE 800LOS ANGELES, CA 90025Date:No:Description:ISSUED FOR PERMIT01/29/20213A2.101/8"=1'-0"ENLARGED CANOPY PLAN2A2.101A4.12A2.10433433433433433433433433433433343443343343343356SLOPED ROOF, SEESTRUCTURALSLOPED ROOF, SEESTRUCTURALSLOPED ROOF, SEE STRUCTURAL SLOPED ROOF, SEE STRUCTURAL C OF COLUMNL2A4.114ROOF RIDGE 2TYP1TYP7773318913131313487910101212147C OF COLUMNL10102A4.21A4.2