20-103896-CO- SITE PLANIBC CHAPTER 9 BUILDING IS EQUIPPED WITH AN AUTOMATIC FIRE ALARM AND DETECTION SYSTEM WITH A MUNICIPAL TRIP CIRCUIT IN ACCORDANCE WITH IBC SECTION 907. IBC CHAPTER 9 BUILDING IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH IBC SECTION 903. IBC SECTION 602 V-B (NON-FIRE RATED) (COMBUSTIBLE CONSTRUCTION) CONSTRUCTION TYPE AUTOMATIC FIRE SPRINKLER SYSTEM FIRE ALARM AND DETECTION SYSTEM OCCUPANT LOAD C O D E I N F O R M A T I O N GOVERNING CODE OCCUPANCY CLASSIFICATION 2015 INTERNATIONAL BUILDING CODE (IBC) WASHINGTON STATE AMENDMENTS 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) WASHINGTON STATE AMENDMENTS 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 UNIFORM PLUMBING CODE (UPC) IBC CHAPTER 3 A-2 RESTAURANT IBC TABLE 1004.1.2 FIRST FLOOR 66 OCCUPANTS * TOTALTOTALTOTALTOTAL 1,356 SQ FT / 200 OCCUPANTS = 7 * 882 SQ FT / 15 = 59 * BUSINESS AREAS (1 OCCUPANT / KITCHENS: 200 GROSS) G E N E R A L N O T E S 1. ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND ORDINANCES. WHERE MORE THAN ONE CODE OR ORDINANCE CONFLICT WITH EACH OTHER, THE MORE RESTRICTIVE CODE SHALL GOVERN. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE AND SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY UNCERTAINTIES OR DISCREPANCIES WITH DRAWINGS. 3. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AT THE SITE, PROTECT THEM FROM DAMAGE AND REPORT ANY DISCREPANCIES WITH DRAWINGS. 4. THE CONTRACTOR SHALL INSURE THE HEALTH AND SAFETY OF THE PUBLIC AND ALL WHO ENTER THE BUILDING DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL VERIFY AND COORDINATE THE WORK OF SUBCONTRACTORS AND ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. 6. DRAWINGS SHALL NOT BE SCALED. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS. 7. ALL CONSTRUCTION SHALL MEET OR EXCEED LOCAL INDUSTRY STANDARDS. DETAILS ARE PROVIDED TO INDICATE MINIMUM QUALITY AND TO GIVE STANDARDS OF CONSTRUCTION. IF A CONDITION IS NOT SPECIFICALLY DETAILED, SUBMIT A SUGGESTED DETAIL FOR GUIDANCE AND APPROVAL. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN, PERMITTING AND CONSTRUCTION OF MECHANICAL AND ELECTRICAL WORK AS REQUIRED TO ACCOMMODATE CONSTRUCTION AND SHALL PROVIDE ALL NECESSARY SHAFTS, OPENINGS, BASES AND STRUCTURAL SUPPORT FOR DUCTS, PIPES, CONDUITS AND EQUIPMENT. 9. DIMENSIONS ON PLANS ARE TO FACE OF STUD, CENTER OF COLUMN, CENTER OF MULLION, FACE OF CONCRETE, FACE OF MASONRY, FACE OF FRAME OR FACE OF ROUGH OPENING, UNLESS OTHERWISE NOTED. 10. LABORATORY TESTING AND SPECIAL INSPECTION REQUIRED IN ACCORDANCE WITH IBC CHAPTER 17 FOR ALL FIELD WELDING, HIGH STRENGTH BOLTING AND ALL STRUCTURAL CONCRETE. OWNER TO HIRE AN INDEPENDENT SPECIAL INSPECTOR AND TESTING LAB FOR ALL CODE REQUIRED TESTING AND SPECIAL INSPECTIONS. 11. REPAIR / REPLACE EXISTING WALL FLOOR AND CEILING FINISHES TO MATCH EXISTING ADJACENT FINISHES WHEN DAMAGED DURING COURSE OF CONSTRUCTION. 12. DEMOLISH ALL EXISTING BUILDING COMPONENTS NECESSARY TO CONSTRUCT WORK CAP ALL EXISTING UTILITIES (PLUMBING, ELECTRICAL AND MECHANICAL) BEHIND WALLS FLOORS, ETC. 13. SUSPENDED CEILINGS TO BE DESIGNED FOR SEISMIC DESIGN CATEGORY D, E, OR F. 14. REFER TO SHEET A200 FOR DETAILS AND PLUMBING FIXTURE AND MOUNTING HEIGHTS. NORTH SECTION NUMBER SHEET NUMBER SHEET NUMBER SECTION LETTER SHEET NUMBER DETAIL NUMBER REVISION C.O.S. = center of structure F.O.S. = face of structure (E) = existing WALL SECTION GRID LINE DESIGNATION BUILDING SECTION DETAIL REVISION MATCHLINE NORTH ARROW 01 A ELEVATION NUMBER SHEET NUMBER EXTERIOR ELEVATION ELEVATION NUMBER SHEET NUMBER INTERIOR ELEVATION MATCHLINE 6B A300 10B A400 10B A500 3B A700 1 A601 3A 10A 5A 7A 01 A F.O.S. C.O.S.F.O.S.C.O.S.F.O.S. C.O.S.F.O.S.C.O.S.P R O J E C T I N F O R M A T I O N BUILDING AREA TENANT IMPROVEMENT 2,775 SQ FT D E F E R R E D S U B M I T T A L S HVAC DRAWINGS ARE DEFERRED TO CONTRACTOR'S DESIGN-BUILD SUBMITTAL. HVAC DRAWINGS PLUMBING DRAWINGS ARE DEFERRED TO CONTRACTOR'S DESIGN-BUILD SUBMITTAL. PLUMBING DRAWINGS ELECTRICAL AND LIGHTING DRAWINGS ARE DEFERRED TO CONTRACTOR'S DESIGN-BUILD SUBMITTAL. ELECTRICAL AND LIGHTING DRAWINGS FIRE SPRINKLER DRAWINGS ARE DEFERRED TO CONTRACTOR'S DESIGN-BUILD SUBMITTAL. FIRE SPRINKLER DRAWINGS ALL DEFERRED SUBMITTALS SHALL BE SUBMITTED TO ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO SUBMITTING TO BUILDING OFFICIAL. DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. A RECORD DRAWING SET OF THE APPROVED SUBMITTAL SHALL BE SUBMITTED TO ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO COMMENCEMENT OF RELATED WORK. FIRE ALARM DRAWINGS ARE DEFERRED TO CONTRACTOR'S DESIGN-BUILD SUBMITTAL. FIRE ALARM DRAWINGS design group AMERICAN INSTITUTE OF ARCHITECTS HELIX DESIGN GROUP, INC DATE JOB NO. REVISION DATE Ó HELIX DESIGN GROUP, INC.: All rights reserved. No part of this document may be reproduced in any form or by any means without permission in writing from Helix Design Group DRAWING NO.PLOTTED:FILE PATH:10/5/2020 5:27:48 PMC:\Users\KaylaR\Documents\Michoacana Ice Cream_R20_KaylaR.rvt10.06.20 i20-079 G001 COVER SHEET FEDERAL WAY, WASHINGTON PERMIT SET PERMIT SET MICHOACANA ICE CREAM SHOP TENANT IMPROVEMENT 1320 S 324TH STE 108 FEDERAL WAY, WA 98003 CELEBRATION CENTER PROJECT: i20-079 -MICHOACANAMICHOACANA ICE CREAM SHOP CELEBRATION CENTER WHITE HELIX DESIGN GROUP, INC. 6021 12th STREET EAST SUITE 201 TACOMA, WASHINGTON 98424 CONTACTS: DIANE BARRINGER PHONE: (253) 922-9037 DIANEB@HELIXDESIGNGROUP.NET ARCHITECT INTERIORS N.T.S. HELIX DESIGN GROUP, INC. 6021 12th STREET EAST SUITE 201 TACOMA, WASHINGTON 98424 CONTACT: DIANE BARRINGER PHONE: (253) 922-9037 EMAIL: DIANEB@HELIXDESIGNGROUP.NET NORTH NORTH S Y M B O L S S H E E T I N D E XS I T E P L A N GENERAL DRAWINGS ARCHITECTURAL DRAWINGS PROJECT LOCATION MICHOACANA 13608 168TH ST CT E PUYALLUP, WA 98374 CONTACT: CEASAR AGUINIGA BAEZ PHONE: 206.640.3408 LAMICHOACANACLASSIC@GMAIL.COM TENANT AREA OF WORK N.T.S. V I C I N I T Y M A P DEMOLITION DRAWINGS A100 FLOOR PLAN A120 REFLECTED CEILING PLAN A130 INTERIOR FINISHES PLAN A180 FFE PLAN & SCHEDULE A200 SCHEDULES A601 INTERIOR ELEVATIONS A750 INTERIOR METAL FRAMING DETAILS A751 INTERIOR METAL FRAMING DETAILS A752 INTERIOR METAL FRAMING DETAILS D100 DEMOLITION FLOOR PLAN D120 DEMOLITION REFLECTED CEILING PLAN G001 COVER SHEET G040 COLORS AND MATERIALS SCHEDULE STATE OF WASHINGTON 6934 LOWELL CATE REGISTERED ARCHITECT RECEIVED CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Oct 09 2020 20-103896-CO- Building Plan Set-10-08-20-V1