Loading...
22-100662City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: OPTIMAL ADULT FAMILY HOME Project Address: 1303 S 302ND ST Building - Single Family Permit #:22-100662-00-SF Inspection Request Line: (253) 835-3050 Parcel Number: 025300 0130 Project Description: Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** Owner Applicant Contractor Lender MERCY MWANGI MERCY MWANGI 1303 S 302ND ST 1303 S 302ND ST FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 Census Category: 434 - Residential alt/add - no change in number of units Includes: # 1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) Additional Permit Information Mechanical to be Included? .................................... No Plumbing to be Included? ........................................ No Is this an Online or O.T.C. application? .................. Yes No Fixtures Associated With This Permit 11 PERMIT EXPIRES Tuesday, 9 August, 2022 Permit Issued on Thursday, February 10, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. { Owner or agent: Date: ( L) J �� f Inc AIM 29 W 0 Lu 4�z R311-2 Means of Egress YES NO R311.2 Door must be side-hin ed with min. width of 32 inches between face of door and stop. Height not less than 78 inches. R330.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping, pinchingor twisting of the wrist lever e . Q 0 R330.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry © Q without use of ke , tool orspecial knowledge. R311-7 Stairways N/A YES NO R311.7.5.1 Riser Height: Max riser height shall be P/+ inches 8 inches in structures built prior to July i 2004 R311.7.5.2 Tread Depth: Min. tread depth shall be in 10 inches 9 inches in structures built prior to July 1, 2004 R330.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple E3 13 risers. Handrails shall be installed in accordance with R311.7.8.1— R311.7.8.4 R330.8 Grab Bars In Bathrooms N/A YES NO Grab bars shall be installed for all water closets (toilets), bathtubs and showers according to R330.8. Water Closets toilet shall have ab bars installed on both sides accordingto R330.8.3 0 Bathtubs shall have two vertical and three horizontal grab bars installed according to R330.8.4 Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R330.8.5 0 Shower stalls must be minimum size of 30 inches deep by 48 inches ton 11330.11 Q PASSED NAME OF AFH: Adult -Family Home -Project Address BUILDING DEPT. INSPECTORS NAME (PRINT) BUILDING DEPT. INSPECTORS SIGNATURE BUILDING DEPT. OFFICE ADDRESS DATE: OFFICE PHONE NUMBER: Application and inspection checklist developed by Washington Association of Building Officials (WABO), in cooperation with Department of Social and Implementation Date: 2021 February 01 Updated: 2021 February SECTION 5 MUST BE COMPLETED BY THE BUILDING -DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN —USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A BCD E AND FAND CLASSIFICATION CODES, NSl OR NS2. R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: Type S — where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. Type NS1— where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R330.9 is provided to evacuate residents to public area. Type NS2 —where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with R330.9 are provided to evacuate residents to public area. SLEEPING ROOM A Type S E3 Type NS3 E3 Type NS2 YES NO Closet door/s are readily openable from the inside JL3 Yes JoNo N/A Smoke alarm is installed in the bedroom Bedroom door opens easily and quickly from the outside when locked 0 0 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 0 0 Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed 0 0 SLEEPING ROOM B Type S JE3Type NS1 Type NS2 YES NO Closet door/s are readily openable from the inside JE3 Yes 113No /A I Smoke alarm is installed in the bedroom D 0 Bedroom door opens easily and quickly from the outside when locked 13 0 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 13 0 Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed [] [] SLEEPING ROOM C JE3 Type S Type NSi Type NS2 YES NO Closet door/s are readily openable from the inside 113 Yes 113 No /A I Smoke alarm is installed in the bedroom 0 Q Bedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 0 0 Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed p Q SLEEPING ROOM D Type S 10 Type NS1 113 Type NS2 YES NO Closet door/s are readily openable from the inside Yes No I E3N/A_ I Smoke alarm is installed in the bedroom L] 0 Bedroom door opens easily and quickly from the outside when locked 13 [' Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 13 0 Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed E] 0 SLEEPING ROOM E TM Type S Type NSl Type NS2 YES NO Closet door/s are readily openable from the inside [3 Yes 13 No /A I Smoke alarm is installed in the bedroom [] 0 Bedroom door opens easily and quickly from the outside when locked Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 13 0 Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed © 0 SLEEPING ROOM F T13 Type S U Type NSl 113 Type NS2 YES I NO Closet door/s are readily openable from the inside 113 Yes Q No I E3N/A Smoke alarm is installed in the bedroom © 0 Bedroom door opens easily and quickly from the outside when locked Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF 13 13 Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowel 13 [� Implementation Date: 2021 February 01 Updated: 2021 February (Effective Feb. 1, 2021 W4C 51-51-0330 Section R330 — Adult family homes. SECTION R330 ADULT FAMILY HOMES R330.1 General. This section shall apply to all newly constructed adult family homes and all existing single family homes being converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington department of social and health services prior to July 1, 2001. R330.2 Reserved. R330.3 Sleeping room classification. Each sleeping room in an adult family home shall be classified as: 1. Type S - Where the means of egress contains stairs, elevators or platform lifts. 2. Type NS1 - Where one means of egress is at grade level or a ramp constructed in accordance with R330.9 is provided. 3. Type NS2 - Where two means of egress are at grade level or ramps constructed in accordance. with R330.9 are provided. R330.4 Types of locking devices and door activation. All bedroom and bathroom doors shall be openable from the outside when locked. Every closet shall be readily openable from the inside. Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. Pocket doors shall have graspable hardware available when in the closed or open position. The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum. Required exit doors shall have no additional locking devices. Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing reentry into the adult family home without the use of a key, tool or special knowledge. R330.5 Smoke and carbon monoxide alarm requirements. All adult family homes shall be equipped with smoke and carbon monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the detection device warning is audible from all areas of the dwelling upon activation of a single alarm. R330.6 Escape windows and doors. Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings will be approved as meeting this requirement. R330.7 Fire apparatus access roads and water supply for fire protection. Adult family homes shall be served by fire apparatus access roads and water supplies meeting the requirements of the local jurisdiction. R330.8 Grab bar general requirements. Where facilities are designated for use by adult family home clients, grab bars for water closets, bathtubs and shower stalls shall be installed according to this section. R330.8.1 Grab bar cross section. Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum and 2 inches maximum. Grab bars with noncircular cross section shall have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. R330.8.2 Grab bar installation. Grab bars shall have a spacing of 1 112 inches between the wall and the bar. Projecting objects, control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab bar shall have a clear space of 1 1/2 inches to the grab bar. EXCEPTION: Swing -up grab bars shall not be required to meet the 1 1/2 inch spacing requirement. Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener, mounting device or supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering unit. Acrylic bars found in bathing units shall be removed. Fixed position grab bars, when mounted, shall not rotate, spin or move and have a graspable surface finish. R330.8.3 Grab bars at water closets. Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing -up bars. Grab bars shall meet the requirements of R330.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars, regardless of type used, shall be between 25 inches minimum and 30 inches maximum. Implementation Date: 2021 February 01 Updated: 2021 February Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code Reference`s: 2018 IRC section R330 (WAC 51-51) APPLICATION NUMBER: ISECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED By APPLICANT BEFORE INSPECTION WILL BE PROCESSED I SECTION 1 — PROPERTY INFORMATION l 0 07,�, j60 -� 0 13 0 SITE ADDRESS: �-n 1 �� % a a5SE55flR SECTION 2 — APPLICANT INFORMATION PROPERTY OWNER NAME: M g4qC-1 MOf& t� �I u!AM I + l u �1u DAYTIME PHONE: �� 331J 7�17 To AFH LICENSEE NAME (IF DIFFERENT): DAYTIME PHONE: SECTION 3 — FLOOR PLAN ZI On a separate sheet of paper (8 1/2 x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A. B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. SECTION 4 — DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of are Adult Family Home at this location. I agree to hold harmless the jurisdiet€on conducting such inspections, at my request, as to any c€aim Qnduding costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person, including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application. DPROPERTYOWNER DAPPLICANT DLICENSEE Implementation Date: 2021 February 01 Updated: 2021 February