Loading...
20-101386-CO-Building A Structural Calculation Adendum-05-05-2022-V1Structural Calculation Addendum For IRG Greenline Building A Federal Way, WA Project # 2180307.20 Project Principal Danial L. Booth PE SE Sr. Engineer Larry Higgins PE Design Criteria Design Codes and Standards Codes and Standards: Structural design and construction shall be in accordance with the applicable sections of the following codes and standards as adopted and amended by the local building authority: International Building Code, 2015 Edition. Structural Design Criteria: Live Load Criteria: Roof (Min Blanket Snow)25 psf Slab on Grade 250 psf Wind Load Criteria: Ultimate Wind Speed 110 mph Risk Category II Wind Exposure B Topographic Factor 1.0 Seismic Criteria: Risk Category II Seismic Importance Factor 1.0 Ss = 1.279 S1 = 0.491 Sds = 0.853 Sd1 = 0.428 Site Class = E Seismic Design Category = D Response Modification Coeff. (R): 5.0 Seismic Response Coeff. (Cs): 0.171 05/05/2022 Soil Criteria: Based on Geotechnical Engineering Report by: GeoEngineers, dated March 9, 2017. Allowable Soil Bearing Capacity: 4000psf, allow 33% increase for loads from wind or seismic origin. Active Earth Pressure = 35pcf (un-restrained) / 55pcf (restrained Friction Coefficient = 0.35 (SF=1.5) Passive Pressure = 300psf (SF=1.5) Project Description The project consists of standard single loaded concrete tilt warehouse/distribution building. The walls consist of concrete tilt bearing walls, steel joist and joist girders, wood purlins and plywood sheathed roof.