Loading...
20-101386-CO-Response Letter-05-05-2022-V1 Civil Engineers Structural Engineers Landscape Architects Community Planners Land Surveyors Neighbors TAC O MA 2215 North 30th Street Suite 300 Tacoma, WA 98403-3350 253.383.2422 TEL www.ahbl.com May 4, 2022 Scott Sproul, Building Official City of Federal Way 33325 8th Avenue South Federal Way, WA 98003-6325 Project: IRG Greenline Business Park Building A, AHBL No. 2180307.20 Subject: Response to WC3 Comments dated April 22, 2022 Woodbridge Building A - Structural Only - Plan Review Comments 1st Review Federal Way Project No. 20-101386-CO Dear Scott Sproul: This letter is in response to the WC3 comments dated April 22, 2022, regarding the above referenced project. The comments are included below (verbatim) for your reference. Our responses are shown in bold after each comment. STRUCTURAL COMMENTS Structural Drawings S1. Sheet S0.2: Please add a note to the “Open Web Steel Joists” section, stating that a certificate of compliance must be submitted to the building official upon completion of fabrication in accordance with IBC 2207.5. Response: Note added to 5.6.8. S2. Sheet S3.1: The project calls for tilt-up panels to be directly connected to the floor slab, with no physical connection to the footing. Please provide calculations showing that the portion of the floor slab that is used is capable of transferring the required forces to the supporting soils. In addition, please provide a check of the panel-to-slab connection for side-edge concrete breakout. Response: Tilt panels are connected to slab via #5 at 24-inch o.c. dowels. Using shear friction, this gives 4.1K/ft capacity. Load to slab ends up 1.45k/ft. Refer to the attached calculation sheet. Slab to panel connection is more than adequate for worst case loading. S3. Sheet S3.2: Please provide the size of the concrete pier shown in detail 2. Response: Dimension added. Scott Sproul, Building Official May 4, 2022 2180307.20 Page 2 of 2 Structural Calculations S4. It appears that a live load reduction was used on the typical panel calculations. Please provide the live load reduction calculations and show that this applicable at the tilt panels. Response: Note that roof live load was incorrectly added as 12psf. Even without any roof live load reduction and using 20psf, this is lower than the roof snow load of 25psf, which controls design. No additional calculations required. If you have any questions, please call me at (253) 383-2422. Sincerely, Larry A. Higgins, PE Project Manager LAH/lsk Q:\2018\2180307\WORDPROC\Letters\20220504 Ltr (Resp-FW-BldgA Rev1) 2180307.20.docx