Loading...
20-101386-CO-Comment Responses-05-13-2022-V1IRG Woodbridge Building A Comment Responses Comment Number Sheet Number Jurisdiction/ Department Comment Designer Response 1 PM-01 CITY OF FEDERAL WAY INSTALL YELLOW PAINTED TYPE "C" BLOCK CURB [SOUTH OF NEW ISLAND].Incorporated as requested. See construction note #10. 2 PM-01 CITY OF FEDERAL WAY INSTALL YELLOW PAINTED TYPE "C" BLOCK CURB [NORTH OF NEW ISLAND].Incorporated as requested. See construction note #10. 3 PM-01 CITY OF FEDERAL WAY Replace Drawing 3-51 with WSDOT TS-4 steel post Incorporated as requested. All new sign notes reference WSDOT std plan G-24.50. 4 PM-01 CITY OF FEDERAL WAY INSTALL BIKE YIELD TO PED SIGN Incorporated as requested. See sign note S8. 5 PM-02 CITY OF FEDERAL WAY Dwg. No. 3-51 no longer valid. City has changed from wood to steel post. Use WSDOT TS-4 steel post std plans G-24.50.02 Incorporated as requested. All new sign notes reference WSDOT std plan G-24.50. 6 PM-02 CITY OF FEDERAL WAY INSTALL BIKE YIELD TO PED SIGN NB AND SB ENTERIING THE ROUNDABOUT Incorporated as requested. See sign note S9. 7 PM-03 CITY OF FEDERAL WAY Signed have been installed per condition and email from ESM. Update sheet to reflect field including new steel post Incorporated as requested. Sheet PM-03 reflects the four newly installed weight signs on steel post. 8 IL-01 CITY OF FEDERAL WAY Specified luminaire model may changed or no longer available.Verify with vendor. New part number should be ARCH-M-PA2-80-740-U-T2R-AP-10K-PR7 with 83W LED Incorporated as requested. See revised photometric calculations. 9 IL-01 CITY OF FEDERAL WAY Add conductor shall be alluminum and CIMCON control node #iSLC-3100-7P-U-A-G-IO-CATB-05-T shall be installed on all luminaires Incorporated as requested. 10 IL-01 CITY OF FEDERAL WAY Specify new conductor shall be alluminum Incorporated as requested. 11 IL-01 CITY OF FEDERAL WAY New conduit should be 2" min. The 1.5" NEW conduit shown in the wire schedule is for new conduit segments that are intercepting existing conduit runs and extending to new junction box locations, therefore the conduit is matching the existing conduit size. 12 IL-01 CITY OF FEDERAL WAY Add CIMCON control node #iSLC-3100-7P-U-A-G-IO-CATB-05-T on luminaire. Remove existing foundation and compact void with all luminaires relocation. Incorporated as requested. 13 IL-01 CITY OF FEDERAL WAY Must be reviewed and approved by WSDOT These pole relocations were reviewed and approved by WSDOT during the interchange improvement permitting process. 14 IL-01 CITY OF FEDERAL WAY WSDOT approval #1 and #2 These pole relocations were reviewed and approved by WSDOT during the interchange improvement permitting process. 15 IL-01 CITY OF FEDERAL WAY This should be in the 6' planter strip. Verify. Light pole #11 cannot be within the planter as it conflicts with existing utilites. If placed in the planter strip avoiding utilities, the pole would be 2.5-FT from face of curb and therefore wouldn't be able to achieve the minimum 6' clearance from the face of curb. A 16-FT arm would be necessary to achieve a 2-FT lamp overhang but this is not available. Therefore, the maximum available luminaire arm length of 10-FT was proposed. 16 IL-01 CITY OF FEDERAL WAY Specified luminaire model may changed or no longer available.Verify with A. New part number should be ARCH-M-PA2-80-740-U-T2R-AP- 10K-PR7 with 83W LED Incorporated as requested. See revised photometric calculations. Page 1 of 2 5/13/2022 IRG Woodbridge Building A Comment Responses Comment Number Sheet Number Jurisdiction/ Department Comment Designer Response 17 IL-01 CITY OF FEDERAL WAY Install in planter strip if it's 6' per Dwg. No. 3-39A Light pole #11 cannot be within the planter as it conflicts with existing utilites. If placed in the planter strip avoiding utilities, the pole would be 2.5-FT from face of curb and therefore wouldn't be able to achieve the minimum 6' clearance from the face of curb. A 16-FT arm would be necessary to achieve a 2-FT lamp overhang but this is not available. Therefore, the maximum available luminaire arm length of 10-FT was proposed. Page 2 of 2 5/13/2022