Loading...
21-103294-UPV-Certificate of Water Availability-08-06-2021-V1winco wtr first pg.docx (Form Update 3/13/20)Page 1 of 2 WATER CERTIFICATE OF AVAILABILITY Lakehaven Water & Sewer District – Development Engineering Section 31623 – 1st Ave S  PO Box 4249  Federal Way, WA 98063-4249 Email: DE@Lakehaven.org  Telephone: 253-945-1581 or 253-945-1580 This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations in Lakehaven’s or Other Purveyor’s system facilities. Proposed Land Use: Building Permit-SFR () Building Permit-MFR () Building Permit-Other Subdivision () Short Subdivision () Binding Site Plan Boundary Line Adjustment Other (specify/describe) Tax Parcel Number(s): 415920-0710 and 415920-0725 Site Address: 160 SW Campus Dr LWSD GIS Grid: H-12 Ex. Bldg. Area to Remain: 67,000 sf New Bldg. Area Proposed: 15,600 sf WATER SYSTEM INFORMATION 1.Water service can be provided by service connection to an existing 12” and 8” diameter water main that is onsite. 2.Water service for the site will require an improvement to LWSD’s water distribution system of: a. feet of ” diameter water main to reach the site; and/or b. The construction of a water distribution system on the site; and/or c. A major portion of LWSD’s comprehensive water system plan would need to be implemented and/or constructed; and/or d. Other (describe): . 3.a. The existing water system is in conformance with LWSD’s Comprehensive Water System Plan. b. The existing water system is not in conformance with LWSD’s Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4.a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of water service outside of LWSD’s water service area. b. Annexation or Boundary Review Board approval will be necessary to provide service. 5.Water service is subject to: a. Payment of connection charges (to be determined by LWSD); b. Proof or reservation of easement(s) as required by LWSD; c. Other: New or modified service connections will require evaluation and may need Service Connection Application. Comments/special conditions: . The nearest fire hydrant is approximately onsite. System hydraulic model results (FF #421), at no less than 20 psi, indicate that LWSD’s standard maximum allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 4600 GPM for two (2) hours. This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements, contact LWSD for additional information. 538 Pressure Zone Est. Meter Elevation(s)-GIS: High 252+/-, Low 248+/- Est. Pressure Range at Meter(s) (psi): 115-125 I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BILL NELSON Title: ENGINEERING TECH III Signature: Bill Nelson (signed electronically)Date: 7/26/21 þ þ þ þþ þ þ þ þ þ þ þ þ þ þ þ þ þ þ þ!>!>!<!< !>!>!>!>B !>!< !>!>!>!>!>!>B !>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>!>" " "" " " " " " " 1321720010 34604 4TH PL SW 1921049004 34400 1st AVE S 1322020660 27 S 342ND PL 4159200730 132172TRCT 1321720020 34612 4TH PL SW 1321720030 34620 4TH PL SW 1321720040 34628 4TH PL SW 4159200715 1321720050 34636 4TH PL SW 1321720060 397 SW 347TH PL 1321720070 405 SW 347TH ST 4159200710 160 SW CAMPUS DR 4159200720 178 SW CAMPUS DR 4159200725 1921049017 125 SW CAMPUS DR 132170TRCT TRACT 2 2021049110 34424 1ST AVE S 2021049013 34716 1ST AVE S 9291700000 34720 2ND LN S 132202TR11 1STWAY S2NDLN S1ST AVE SSW CAMPUS DRH11 H12 I11 I121ST WAY S1ST AVE SSW CAMPUS DR16"DI6"DI8" DI 8 " D I16"DI12" AC 8"12"DI8"DI12" DI 8" DI 6" PVC 8" DI 8"DI8" DI 6" PVC 8" DI 8 " D I 8" DI 16" DI12" DI 8"8" DI 6"DI8"DI8"DI16"DI8" DI 16"DI8" DI 16"DI8"DI8"16"DI16"DI8" DI 8" DI 8 " D I16" DI12" AC 16" DI8" DI 8 " D I 8"8" DI 8" DI 8 " D I 8" DI 8" DI8" DI16" D I8" DI8" DI16" DI16" DI8 " D I 12" DI 8" PVC 8" DI8" DI16" DI16" DI8" DI16" DI12" DI 6"4"8" DI12" DI 6"0 370185 Feet NOTE:Lakehaven Utility District neither warrants nor guarantees the accuracy of any facility information provided. Facility locations and conditions are subject to field verification. WATER AVAILABILITY 7/20/21 p winco swr first pg.docx (Form Update 4/2/19)Page 1 of 2 SEWER CERTIFICATE OF AVAILABILITY Lakehaven Water & Sewer District – Development Engineering Section 31623 – 1st Ave S  PO Box 4249  Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580  Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven’s or Other Purveyor’s system facilities. Proposed Land Use: Building Permit-SFR () Building Permit-MFR () Building Permit-Other Subdivision () Short Subdivision () Binding Site Plan Boundary Line Adjustment Other (specify/describe) Tax Parcel Number(s): 415920-0710 and 415920-0725 Site Address: 160 SW Campus Dr LWSD GIS Grid: H-12 Ex. Bldg. Area to Remain: 67,000 sf New Bldg. Area Proposed: 15,600 sf SEWER SYSTEM INFORMATION 1.Sewer service can be provided by service connection to an existing 8” diameter sewer main that is approximately on site and the sewer system has the capacity to serve the proposed land use. 2.Sewer service for the site will require an improvement to LWSD’s sanitary sewer system of: a. feet of ” diameter sewer main or trunk to reach the site; and/or b. The construction of a sanitary sewer collection system on the site; and/or c. A major portion of LWSD’s comprehensive wastewater system plan would need to be implemented and/or constructed; and/or d. Other (describe): . 3.a. The existing sewer system is in conformance with LWSD’s Comprehensive Wastewater System Plan. b. The existing sewer system is not in conformance with LWSD’s Comprehensive Wastewater System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4.a. The proposed site land use is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of sewer service outside of LWSD’s sewer service area. b. Annexation or Boundary Review Board approval will be necessary to provide service. 5.Sewer service is subject to: a. Payment of connection charges (to be determined by LWSD); b. Proof or reservation of easement(s) as required by LWSD; c. Other: Change in sewer service connection will require Sewer Service Connection Permit. Comments/special conditions: Any change in discharge could require a change in required pre-treatment. I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BILL NELSON Title: ENGINEERING TECH III Signature: Bill Nelson (signed electronically)Date: 7/20/21 1030-111 0476-6 0481-3 0481-2 1030-112 0476-2 0476-1 1524-7 1524-6 1524-5 1524-4 1524-3 1524-2 1525-8 1921049004 34400 1st AVE S 4159200730 132172TRCT 1321720020 34612 4TH PL SW 1321720030 34620 4TH PL SW 1321720040 34628 4TH PL SW 4159200715 1321720050 34636 4TH PL SW 1321720060 397 SW 347TH PL 4159200710 160 SW CAMPUS DR 4159200720 178 SW CAMPUS DR 4159200725 1921049017 125 SW CAMPUS DR 132170TRCT TRACT 2 2021049110 34424 1ST AVE S 2021049013 34716 1ST AVE S 9291700000 34720 2ND LN S 132202TR11 H11 H12 I11 I121ST WAY S1ST AVE SSW CAMPUS DR8" PVC 1 2 " C O N C 8" CONC 8" CONC 8" CONC 42"CONC8" DI8" PVC8" PVC8" PVC42" CONC8" PVC8 " P V C 12" CONC12"CONC12"CONC8" PVC12" CONC8" PVC12"CONC42" CONC0 360180 Feet NOTE:Lakehaven Utility District neither warrants nor guarantees the accuracy of any facility information provided. Facility locations and conditions are subject to field verification. SEWER AVAILABILITY 7/20/21 p